首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Optimal liquid chromatography/mass spectrometric [LC/MS(/MS)] analysis depends on both the LC selectivity and the electrospray efficiency. Here, we outline a simple and comprehensive LC/MS/MS strategy for the rapid analysis of a wide range of pharmaceutical compounds. To achieve ultrafast LC separation with little sacrifice in peak capacity, one needs to start with a column that provides a good peak capacity at short gradient run times; secondly, it is important to use high flow rates to achieve a good gradient peak capacity. Following this strategy, it was possible to baseline-resolve a mixture (containing acidic, neutral, and basic pharmaceutical analytes) in seconds. By coupling the selectivity provided by fast LC separation with the specificity of MS/MS detection, it is possible to separate and identify a wide range of analytes in 1-min gradient analyses. Also, the impact of mobile phase pH on both the chromatographic selectivity and the MS/MS sensitivity is demonstrated.  相似文献   

2.
An automated liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method is presented for the screening and confirmation of 16 beta-blocking drugs in clinical and autopsy urine samples. The described method involved C(18) solid phase extraction, LC separation and MS analysis on a triple-stage quadrupole mass analyser. Samples were initially pre-screened for the presence of any beta-blocking drugs using LC/MS with selected ion monitoring. Any compounds tentatively identified as beta-blocking drugs on the basis of their LC retention time and protonated molecular ion were then automatedly subjected to a second analysis in which the relevant MS/MS product ion mass spectra were acquired. These product ion mass spectra were then automatically searched against a 400-substance mass spectral library containing previously acquired beta-blocking drugs. The results demonstrated that library search of beta-blocking drugs in urine with MS/MS product ion mass spectra was more reliable and produced fewer false negatives than library searching with mass spectra derived from single-stage quadrupole MS. The limits of identification in the MS/MS product ion scan ranged from 0.02 mg l(-1) for carvedilol to 1.2 mg l(-1) for pindolol, the majority of the values being below 0.2 mg l(-1).  相似文献   

3.
A series of studies was performed to investigate some of the causes for matrix effects ('ion suppression' or 'ion enhancement') in bioanalytical high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assays. Previous studies have reported that matrix effects are mainly due to endogenous components in biological fluids and are a greater concern for electrospray ionization (ESI) than for atmospheric pressure chemical ionization (APCI). In this report we demonstrate that: (1) matrix effects can also be caused by exogenous materials, such as polymers contained in different brands of plastic tubes, or Li-heparin, a commonly used anticoagulant; (2) matrix effects are not only ionization mode (APCI or ESI) dependent, but also source design (Sciex, Finnigan, Micromass) dependent; and (3) for at least one vendor's design, we found the APCI mode to be more sensitive to matrix effects than the ESI mode. Based on these findings, we have proposed the following simple strategies to avoid matrix effects: (1) select the same brand of plastic tubes for processing and storing plasma samples and spiked plasma standards; (2) avoid using Li-heparin as the anticoagulant; and (3) try switching the ionization mode or switching to different mass spectrometers when matrix effects are encountered. These three strategies have allowed us to use protein precipitation and generic fast LC techniques to generate reliable LC/MS/MS data for the support of pharmacokinetic studies at the early drug discovery stage.  相似文献   

4.
A novel and selective liquid chromatographic–mass spectrometric method (LC‐MS/MS) has been established and validated for simultaneous determination of subutinib and active metabolite in human urine. Urine samples were extracted by liquid–liquid extraction with ethyl acetate and separated on a Wondasil C18 (150 × 2.1 mm, 3.5 µm), with methanol–0.2% formic acid solution (73:27, v/v) as mobile phase at flow rate of 0.2 mL/min. The linear range was 0.5000–200.0 ng/mL for subutinib and active metabolite, with a lower limit of quantitation of 0.5000 ng/mL. Intra‐ and inter‐run precisions were all <11.8 and 14.3%, and the accuracies were all <4.5 and 5.4%, with the extraction recoveries 88.8–97.5 and 93.8–99.4% for the two analytes, respectively. The carryover values were all <15% for the two anayltes. The method was successfully applied to study urinary excretion of subutinib and active metabolite in human after oral administration of subutinib maleate capsules in fed and fasting states. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
Protein glycosylation has a significant medical importance as changes in glycosylation patterns have been associated with a number of diseases. Therefore, monitoring potential changes in glycan profiles, and the microheterogeneities associated with glycosylation sites, are becoming increasingly important in the search for disease biomarkers. Highly efficient separations and sensitive methods must be developed to effectively monitor changes in the glycoproteome. These methods must not discriminate against hydrophobic or hydrophilic analytes. The use of activated graphitized carbon as a desalting media and a stationary phase for the purification and the separation of glycans, and as a stationary phase for the separation of small glycopeptides, has previously been reported. Here, we describe the use of activated graphitized carbon as a stationary phase for the separation of hydrophilic tryptic glycopeptides, employing a chip‐based liquid chromatographic (LC) system. The capabilities of both activated graphitized carbon and C18 LC chips for the characterization of the glycopeptides appeared to be comparable. Adequate retention time reproducibility was achieved for both packing types in the chip format. However, hydrophilic glycopeptides were preferentially retained on the activated graphitized carbon chip, thus allowing the identification of hydrophilic glycopeptides which were not effectively retained on C18 chips. On the other hand, hydrophobic glycopeptides were better retained on C18 chips. Characterization of the glycosylation sites of glycoproteins possessing both hydrophilic and hydrophobic glycopeptides is comprehensively achieved using both media. This is feasible considering the limited amount of sample required per analysis (<1 pmol). The performance of both media also appeared comparable when analyzing a four‐protein mixture. Similar sequence coverage and MASCOT ion scores were observed for all proteins when using either stationary phase. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
A fast chromatographic separation approach that enables rapid method development for high-throughput sample quantification is discussed. This approach has been used to analyze samples from various biological matrices. Data are presented from in vivo pharmacokinetic studies (plasma) and in vitro drug metabolism and transport studies (hepatic microsomes, hepatocytes, and Caco-2 cells).  相似文献   

7.
Ion suppression, a matrix effect that affects quantitative mass spectrometry, is one of the main problems encountered in liquid chromatography/tandem mass spectrometry. Two different clean-up steps for the multi-residue analysis of beta-agonists in urine were evaluated with respect to minimisation of ion suppression, namely, a mixed-phase solid phase extraction (SPE) column, i.e., clean screen Dau (CSD), and a molecular imprinted polymer (MIP) SPE column. Ion suppression experiments revealed that CSD sample clean-up can lead to false negative results for some beta-agonists, and that clean-up using MIP columns is more selective for beta-agonists than the use of CSD columns.  相似文献   

8.
Because of the potential in-source conversion between a lactone and the corresponding hydroxy acid, it has been recognized that a liquid chromatography/tandem mass spectrometric (LC/MS/MS) method developed for quantitation of a lactone drug in the presence of its hydroxy acid metabolite (or vice versa) must incorporate chromatographic separation between the two compounds, unless in-source conversion between the two compounds has been eliminated by the appropriate selection of the LC/MS/MS parameters. We now report that chromatographic separation between a lactone and its hydroxy acid will be required under certain LC/MS/MS conditions used even in the absence of in-source conversion. This is due to the fact that the 18-mass-unit difference between a lactone and its hydroxy acid is, by coincidence, different by only one mass unit from the 17-mass-unit difference between the [M + H](+) and [M + NH(4)](+) ions of the lactone or the hydroxy acid. Thus, the [M + H](+) ion of a hydroxy acid is higher than the [M + NH(4)](+) ion of its lactone by only one mass unit. Therefore, in a method developed for quantitation of a hydroxy acid drug utilizing a selected-ion-monitoring (SRM) scheme that incorporates its [M + H](+) ion as the precursor ion, the quantitation would be inaccurate due to the interference by the contribution of the A + 1 isotope response from the [M + NH(4)](+) ion of the lactone metabolite present in the sample, unless there is a chromatographic separation between the two compounds. This is true even if Q1 is operated under a unit-mass resolution. The implication of this type of interference, arising from the presence of both the [M + H](+) and [M + NH(4)](+) ions of a drug and its metabolite, to the selection of LC and MS conditions (including mass resolution) will be discussed using the data obtained with a model lactone drug and its hydroxy acid metabolite.  相似文献   

9.
10.
An in-depth study of the reproducibility of data acquired for comparative proteomics analysis using a prototype two-stage heated laminar flow chamber fitted to a commercial high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) instrument was undertaken. The study is based on 24 replicate samples from four independent membrane preparations derived from two matched breast cancer cell lines. Variation and reproducibility in the data were evaluated at several levels highlighting the relative efficiency and variability of the acquisition routines used. Specifically, variation in the number and relative intensities of chromatographic peaks eluted from the LC column, precursor ion selection and sequence identification were evaluated. On average, approximately 6500 chromatographic peaks were generated for each acquisition with a corresponding coefficient of variance (CV) of less than 20%. Precursor ion selection and sequence identification averaged 1380 and 780 events per acquisition sample, respectively, with corresponding CVs of less than 10% for each. The reproducibility in the precursor ion selection was typically better than 60% between similar replicates. Using protein and peptide internal standards, it was found that the CV in retention time across the gradient between two acquisition pairs was typically less than 5%, whereas the average intensity ratio was 1.0 (expected) with a CV approaching 20%. An evaluation of the intensity ratios calculated from endogenous peptide sequences, identified across the acquisition set, indicated a CV of approximately 30%. Similarly, the CV associated with the top 1000 peptides indicated a mean and median of 28.4 and 26.95%. For a given acquisition pair it was also found that approximately 11% of the chromatographic peaks eluting from the column were linked to a sequence or identified. For these experiments, less than 10% of the peak pairs had absolute ratios greater than 2.0 and of those only approximately 10% had sequences linked to them. For each matched acquisition set on average 406 proteins were identified with a CV of less than 10%. Of the proteins that were identified approximately 30% had at least one predicted trans-membrane domain, indicating a four-fold increase over a crude homogenate sample with only minor enrichment. During these experiments it was found that the interface did not significantly alter the relative charge state distribution of ions, nor did it introduce significant interference from background ions. The interface was capable of 24-hour acquisition cycles.  相似文献   

11.
1,3-Butadiene, a common air pollutant formed in the combustion of organic matter, has been assessed by the U.S. EPA to be a strongly carcinogenic compound. This risk assessment is very uncertain because of the lack of information on the dose of the powerful carcinogenic metabolite diepoxybutane (DEB). This report presents an analytical method for in vivo dose monitoring of a unique marker for DEB. For a large number of alkylating agents in vivo doses are monitored by measurement by gas chromatography/mass spectrometry (GC/MS) of adducts to N-terminal valine in hemoglobin (Hb), using a modified Edman degradation method. This method is applicable to monofunctional epoxides from butadiene. However, in reaction with N-terminal valine, DEB forms an adduct which is ring-closed to a pyrrolidine, N,N-(2,3-dihydroxy-1,4-butadiyl)valine, with a tertiary amino group that prevents detachment of the alkylated valine by the Edman reagent. Therefore a method has been developed based on the analysis by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) of the N-modified N-terminal peptides enriched after trypsin digestion of globin. In this study Hb samples from mice injected intraperitoneally with (+/-)-DEB were examined qualitatively and quantitatively with regard to the ring-closed adduct. The N-terminal pyrrolidine-heptapeptide was identified in treated mice. The highest adduct levels were obtained in samples from animals given the highest dose of DEB and the adduct levels were below the detection level in control mice.  相似文献   

12.
A hydrophilic interaction liquid chromatographic method with tandem mass spectrometry for the determination of atenolol, a beta-blocking agent, in human plasma has been developed and validated over the curve range of 10--2000 ng/mL. The assay was based on protein precipitation followed by evaporation of the extraction solvent, reconstitution with acetonitrile, and chromatography on an Hypersil silica column (50 x 4.6 mm) using a low aqueous--high organic mobile phase. The mobile phase consists of 85% acetonitrile, 15% water, 0.5% acetic acid and 0.04% trifluoroacetic acid and runs isocratically at a flow rate of 2.0 mL/min. The column ef fluent was split so that 50% of it was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 2.0 min per injection. Atenolol and the internal standard, atenolol-d(7), showed a retention time of 1.0 min. The inter-day and intra-day precision and accuracy of the quality control samples were <5.3% relative standard deviation and <8.0% relative error, respectively. To explore the application of the current method for the analysis of other beta-blocking agents, propranolol and metoprolol were tested under the same chromatographic conditions with retention times of 0.68 and 0.75 min, respectively. The present method could be used for therapeutic drug monitoring, pharmacokinetic and drug--drug interaction studies of beta-blocking agents.  相似文献   

13.
The effects of liquid chromatography mobile phase buffer contents on the ionization and fragmentation of drug molecules in liquid chromatographic/ionspray tandem mass spectrometric (LC/MS/MS) determination were evaluated for simvastatin (SV) and its hydroxy acid (SVA). The objective was to improve further the sensitivity for SV by overcoming the unfavorable condition caused by the formation of multiple major adduct ions and multiple major fragment ions when using ammonium as LC mobile phase buffer. Mobile phases (70:30 acetonitrile-buffer, 2 mM, pH 4.5) with buffers made from ammonium, hydrazine or alkyl (methyl, ethyl, dimethyl or trimethyl)-substituted ammonium acetate were evaluated. Q1 scan and product ion scan spectra were obtained for SV in each of the mobile phases under optimized conditions. The results showed that, with the alkylammonium buffers, the alkylammonium-adducted SV was observed as the only major molecular ion, while the formation of other adduct ions ([M + H](+), [M + Na](+) and [M + K](+)) was successfully suppressed. On the other hand, product ion spectra with a single major fragment ion were not observed for any of the alkylammonium-adducted SVs. The affinity of the alkylammoniums to SV and the basicity of the alkylamines are believed to be factors influencing the formation and abundance of molecular and fragment ions, respectively. Methylammonium acetate provided the most favorable condition among all the buffers evaluated and improved the sensitivity several-fold for SV in LC/MS/MS quantitation compared with that obtained using ammonium acetate buffer. Better precision for SV in both Q1 and SRM scans was observed when using methylammonium buffer compared with those using ammonium buffer. The mobile phase buffer contents did not seem to affect the ionization, fragmentation and chromatography of SVA. The results of this evaluation can be applied to similar situations with other organic molecules in ionspray LC/MS/MS determination.  相似文献   

14.
Electrospray ionization mass spectrometry is used in lipidomics studies. The present research established a top-down liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) shotgun analysis method for phospholipids (PLs) using a normal-phase column or a C30 reverse-phase column with the data-dependent MS/MS scanning mode. A normal-phase column can separate most of the major different classes of PLs. By using LC/ESI-MS/MS with a normal-phase column, approximately 50 molecular species were identified in a PL mixture from rat liver. When the reverse-phase column was used, the PLs could be separated depending on their hydrophobicity, essentially the length of their fatty acyl chains and the number of unsaturated bonds in them. The LC/ESI-MS/MS method using a C30 reverse-phase column was applied to phosphatidylcholine (PC) and phosphatidylethanolamine (PE) mixtures as test samples. Molecular species with the same molecular mass but with different pairs of fatty acyl chains were separately identified. As a result, about 60 PC and 50 PE species were identified. PLs from rat liver were subjected to LC/ESI-MS/MS using the C30 reverse-phase column and about 110 molecular species were identified. Off-line two-dimensional LC/ESI-MS/MS with the normal-phase and C30 reverse-phase columns allowed more accurate identification of molecular species by using one-dimensional C30 reverse-phase LC/ESI-MS/MS analysis of the collected fractions.  相似文献   

15.
A tandem mass spectrometric investigation of the collision-induced dissociation of five commonly prescribed psychoactive pharmaceuticals, risperidone, sertraline, paroxetine, trimipramine, and mirtazapine, and their metabolites has been carried out. Quadrupole ion trap mass spectrometry was employed to generate tandem mass spectrometric (MS/MS) data of the compounds under investigation and structural assignments of product ions were supported by quadrupole time-of-flight mass spectrometry. These fragmentation studies were then utilised in the development of a liquid chromatographic method to identify the drugs and their metabolites in human hair and saliva samples, thus providing relevant profiling information.  相似文献   

16.
In this study, EDTA and heparin are compared as anticoagulants with respect to their efficiency in preventing clot formation in plasma samples that were subsequently analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). A pilot in vivo pharmacokinetic study for the drug chlorpheniramine was conducted in which both EDTA and heparin plasma samples were collected simultaneously. All conditions except the anticoagulant were held constant during the pharmacokinetic study. Bioanalytical results were compared from samples transferred by manual pipette and by an automated liquid handler workstation. The concentration of chlorpheniramine in samples was determined by LC/MS/MS. Results from the analysis of variances (ANOVA) of log-transformed plasma chlorpheniramine concentrations were used to calculate 90% confidence intervals for the ratio least-squares mean values for anticoagulants and for transfer methods. Analytical concentrations of the drug chlorpheniramine were equivalent in heparin- and EDTA-containing plasma. Results suggest that the failure rate for transfer of EDTA plasma (50 micro L by automated workstation or manually) is less than that for heparinized plasma. As a consequence of these results, the vast majority of plasma samples in our laboratories are now collected in EDTA, which allows for use of automated sample transfer resulting in a three-fold timesaving over manual transfer using a single-channel pipette. The ability to use automation has resulted in improved efficiency and cost savings.  相似文献   

17.
This study investigated the effects of matrix interferences on the analytical performance of a triple quadrupole mass spectrometric (MS-MS) detector coupled to various reversed-phase liquid chromatographic (LC) modes for the on-line determination of various types of acidic herbicides in water using external calibration for quantification of the analytes tested at a level of 0.4 microg/l. The LC modes included (i) a single-column configuration (LC), (ii) precolumn switching (PC-LC) and (iii) coupled-column LC (LC-LC). As regards detection, electrospray (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (PI) and negative (NI) ionization modes were examined. Salinity and dissolved organic carbon (DOC) were selected as interferences to study matrix effects in this type of analysis. Therefore, Milli-Q and tap water samples both fortified with 12 mg/l DOC and spiked with sulfometuron-methyl, bentazone, bromoxynil, 2-methyl-4-chlorophenoxyacetic acid, and 2-methyl-4-chlorophenoxypropionic acid at a level of about 0.4 microg/l were analyzed with the various LC-MS approaches. Direct sample injection was performed with volumes of 0.25 ml or 2.0 ml on a column of 2.1 mm I.D. or 4.6 mm I.D. for the ESI and APCI modes, respectively. The recovery data were used to compare and evaluate the analytical performance of the various LC approaches. As regards matrix effects, the salinity provided a dramatic decrease in response for early eluting analytes (k value of about 1) when using the LC mode. Both PC-LC and LC-LC efficiently eliminated this problem. The high DOC content hardly effected the responses of analytes in the ESI mode, while in most cases the responses increased when using APCI-MS-MS detection. Of all the tested configurations, LC-LC-ESI-MS-MS with the column combination Discovery C18/ABZ+ was the most favorable as regards elimination of matrix effects and provided reliable quantification of all compounds using external calibration at the tested low level. The major observed effects were verified with statistical evaluation of the data employing backwards ordinary least-square regression. All tested column-switching modes hyphenated to ESI- or APCI-MS-MS allowed the on-line multi-residue analysis of acidic pesticides in the reference water down to a level of 0.1 microg/l in less than 10 min, emphasizing the feasibility of such an approach in this field of analysis.  相似文献   

18.
Triple quad liquid chromatography mass spectrometric assays (LC/MS/MS) have revolutionized the analysis of drug(s)/metabolite(s) with exceptional speed, sensitivity and selectivity features. From inception to date, several new and innovative features have been regularly proposed by researchers to further enhance the value in the applicability of this analytical tool. However, owing to such compressed run times and scanty sample preparation procedures, LC/MS/MS assays that are not fully optimized generally have issues of matrix effects, where ionization potential is either suppressed or enhanced due to the presence of other materials (endogenous/exogenous) in the matrix. By definition, even co‐medications, isomeric or isobaric impurities, and drug excipients used in dosing solutions could also potentially contribute to matrix effects. This article captures some of the interesting work carried out by researchers to understand and handle matrix effects. Additionally, it provides perspectives to effectively deal with matrix effects. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
A specific and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed and validated for NNAL, a metabolite of the tobacco-specific nitrosamine metabolite NNK. The metabolite was detected in smokers' urine with a limit of quantitation (LOQ) of 20 pg ml(-1) and a linear range up to 1000 pg ml(-1). The method features a single solid-phase extraction step and MS/MS monitoring following electrospray ionization. Fragmentation pathways for the protonated molecular ion are proposed. The sample preparation is simpler than that for gas chromatographic methods reported in the literature and maintains sensitivity adequate for determining NNAL in smokers' urine. By using enzyme hydrolysis to determine total NNAL in urine, the amount of NNAL-glucuronide was calculated. A standard pooled smokers' urine sample used for development gave values of 176 +/- 8 pg ml(-1) free NNAL and 675 +/- 26 pg ml(-1) total NNAL following enzyme hydrolysis. The method was applied to a group of seven smokers; the free NNAL level for the group was 101-256 pg ml(-1) with NNAL-glucuronides at 247-566 pg ml(-1). The ratio of conjugated to free NNAL was in the range 0.98-2.95. The variability in total daily amount of NNAL excreted (ng per 24 h) had RSDs of 6-21% for free NNAL, 7-22% for conjugated NNAL and 6-20% for total NNAL excreted. When normalized to the number of cigarettes smoked, the amounts of NNAL excreted per cigarette smoked were in the range of amounts of NNK yields reported for cigarettes in the literature.  相似文献   

20.
Thermospray high performance liquid chromatography/mass spectrometry (TSP HPLC/MS) was used to analyze five Fusarium mycotoxins in porcine plasma and urine. Four cytotoxic trichothecene mycotoxins, T-2 toxin, HT-2 toxin, diacetoxyscirpenol (DAS), deoxynivalenol (DON), T2 tetraol, and the fungal estrogen zearalenone (F-2 toxin) were analyzed. The thermospray mass spectrum contained molecular weight information with few, if any, fragment signals. Detection limits ranging from 1 to 10 ng of mycotoxin injected onto the HPLC column were obtained using selected ion monitoring (SIM) HPLC/MS. Neither the plasma nor the urine matrix interfered with TSP HPLC/MS analysis of these mycotoxins and no sample derivatization was necessary for the analysis. The TSP HPLC/MS technique appears to be ideal for very sensitive analysis of mycotoxins in biological samples.  相似文献   