首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Age determination of single plutonium particles was demonstrated using five particles of the standard reference material, NBS 947 (Plutonium Isotopic Standard. National Bureau of Standards, Washington, D.C. 20234, August 19, 1982, currently distributed as NBL CRM-137) and the radioactive decay of 241Pu into 241Am. The elemental ratio of Am/Pu in Pu particles found on a carbon planchet was measured by wavelength dispersive X-ray spectrometry (WDX) coupled to a scanning electron microscope (SEM). After the WDX measurement, each plutonium particle, with an average size of a few μm, was picked up and relocated to a silicon wafer inside the SEM chamber using a micromanipulator. The silicon wafer was then transferred to a quartz tube for dissolution in an acid solution prior to chemical separation. After the Pu was chemically separated from Am and U, the isotopic ratios of Pu (240Pu/239Pu, 241Pu/239Pu and 242Pu/239Pu) were measured with a thermal ionization mass spectrometer (TIMS) for the calculation of Pu age. The age of particles determined in this study was in good agreement with the expected age (35.9 a) of NBS 947 within the measurement uncertainty.  相似文献   

2.
 Methodologies based on secondary ion mass spectrometry (SIMS) for isotopic measurements in nuclear forensic applications relevant to the age determination of Pu particles and isotopic composition of oxygen for geolocation assignment are described. For the age determination of Pu particles, a relative sensitivity factor (RSF) to correct for the different ionisation efficiencies of U and Pu, was obtained by analysing standard Pu materials with known ages. An RSF of 2.41±0.05 was obtained for PuO2 from measurements on samples with different Pu/U ratios. In a sample of known origin, using this RSF value, the age calculated from the 238Pu/234U and 240Pu/236U ratios agreed well with the reported age of 2.3 years. For geolocation assignment, a new approach based on the measurement of differences in the natural abundance of 18O and 16O isotopes and their ratio was developed. The instrumental mass discrimination of the 18O/16O ratio was determined using three O-isotope samples of different chemical composition. The measured precision (the standard error of 100 cycles/analysis) obtained for the oxygen isotopic measurement on the samples was typically ±1.1‰.  相似文献   

3.
Esaka F  Magara M  Suzuki D  Miyamoto Y  Lee CG  Kimura T 《Talanta》2010,83(2):569-573
Information on plutonium isotope ratios in individual particles is of great importance for nuclear safeguards, nuclear forensics and so on. Although secondary ion mass spectrometry (SIMS) is successfully utilized for the analysis of individual uranium particles, the isobaric interference of americium-241 to plutonium-241 makes difficult to obtain accurate isotope ratios in individual plutonium particles. In the present work, an analytical technique by a combination of chemical separation and inductively coupled plasma mass spectrometry (ICP-MS) is developed and applied to isotope ratio analysis of individual sub-micrometer plutonium particles. The ICP-MS results for individual plutonium particles prepared from a standard reference material (NBL SRM-947) indicate that the use of a desolvation system for sample introduction improves the precision of isotope ratios. In addition, the accuracy of the 241Pu/239Pu isotope ratio is much improved, owing to the chemical separation of plutonium and americium. In conclusion, the performance of the proposed ICP-MS technique is sufficient for the analysis of individual plutonium particles.  相似文献   

4.
Mixed-actinide microstandard particles have been produced for calibration and performance testing of isotope-ratio mass spectrometers and ion and electron microprobe instruments. The spherical micrometer-size particles consist of an aluminosilicate matrix loaded with 2.2% by weight of isotopically certified uranium and 0.11% by weight of isotopically certified plutonium. The uranium and plutonium isotopic compositions have been verified by both thermal ionization mass spectrometry and secondary ionization mass spectrometry (SIMS). The elemental composition of the microspheres has been determined by both electron microprobe and SIMS analysis.  相似文献   

5.
In this paper we describe the application of laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) coupling to particle analysis, i.e., the determination of the isotopic composition of micrometric uranium particles. The performances of this analysis technique are compared with those of the two reference particle analysis techniques: secondary ion mass spectrometry (SIMS) and fission track-thermo-ionization mass spectrometry (FT-TIMS), based on the measurement of the isotopic ratios of 235U/238U in particles present in an inter-comparison particulate sample. The agreement of the results obtained using LA-ICP-MS with target values and with the results obtained using FT-TIMS and SIMS was good. Accuracy was equivalent to that of the other two techniques (±3 % deviation). However, relative experimental uncertainties present with LA-ICP-MS (7 %) were higher than those present with FT-TIMS (4.5 %) and SIMS (3 %). Furthermore, measurement yield of LA-ICP-MS coupling was close to that obtained with the same quadrupole ICP-MS for the measurement of a liquid sample (~10?4), but lower than that obtained with FT-TIMS and SIMS, respectively, by a factor of 10 and 20, although the particles analyzed using LA-ICP-MS were most likely smaller (diameter ~0.6 μm, containing 4–7 fg of 235U). Nevertheless, thanks to the brevity of the signals obtained, the detection capacity for low isotopic concentrations by LA-ICP-MS coupling is equivalent to that of FT-TIMS, although it remains well below that of SIMS (×15). However, with more sensitive double focusing ICP-MS, performances equivalent to those achieved using SIMS could be obtained.  相似文献   

6.
The origin and release date of environmental plutonium have been assessed by the measurement of plutonium and americium isotopic composition. The applicability and sensitivity of different plutonium isotope ratios, 240Pu/239Pu and 241Pu/239Pu measured by inductively coupled plasma sector field mass spectrometry and 238Pu/239Pu analysed by alpha spectrometry, have been evaluated for origin determination in several types of environmental samples. With use of mixing models the contribution of different sources (e.g. global fallout or Chernobyl) can be calculated. By the measurement of the 241Am/241Pu isotope ratio, the release date (i.e. formation of 241Pu by irradiation) can be estimated in environmental samples, which is an important parameter to distinguish recent plutonium release from previous (e.g. Chernobyl) emissions.  相似文献   

7.
The application of scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS) for characterization of mixed plutonium and uranium particles from nuclear weapons material is presented. The particles originated from the so-called Thule accident in Greenland in 1968. Morphological properties have been studied by SEM and two groups were identified: a "popcorn" structure and a spongy structure. The same technique, coupled with an energy-dispersive X-ray (EDX) spectrometer, showed a heterogeneous composition of Pu and U in the surface layers of the particles. The SIMS depth profiles revealed a varying isotopic composition indicating a heterogeneous mixture of Pu and U in the original nuclear weapons material itself. The depth distributions agree with synchrotron-radiation-based mu-XRF (X-ray fluorescence microprobe) measurements on the particle (Eriksson, M., Wegryzynek, D., Simon, R., & Chinea-Cano, E., in prep.) when a SIMS relative sensitivity factor for Pu to U of 6 is assumed. Different SIMS identified isotopic ratio groups are presented, and the influence of interferences in the Pu and U mass range are estimated. The study found that the materials are a mixture of highly enriched 235U (235U:238U ratio from 0.96 to 1.4) and so-called weapons grade Pu (240Pu:239Pu ratio from 0.028 to 0.059) and confirms earlier work reported in the literature.  相似文献   

8.
The determination of isotope ratios in individual uranium particles is very important for nuclear safeguards. In this work, accelerator mass spectrometry (AMS), thermal ionization mass spectrometry (TIMS), and secondary ion mass spectrometry (SIMS) were applied to isotope ratio analysis of individual uranium particles and compared in terms of background, measurement accuracy, and efficiency. Several individual uranium particles (1–7 μm) from certified reference materials were used as samples. The results show that the average values of blank counting rate of 235U for AMS, FT-TIMS (FT: fission track), SEM-TIMS (SEM: scanning electron microscope), and SIMS were 7.3, 7.8, 2.7 and 2.2 cps, respectively. The relative error of 234U/235U and 234U/236U isotope ratios of the particles from U200 for AMS were within 10% and 20%, whereas the results of FT-TIMS and SIMS were within 5% and 10%, respectively. The relative error and external precision of 234U/238U and 235U/238U of the particles from U850 for the method of AMS, SEM-TIMS, and SIMS were within 10% and 5%, respectively. For 236U/238U, the average values of the relative error and external precision measured by AMS were within 5%, which measured by SEM-TIMS and SIMS were all within 10%. AMS has advantages in measuring 236U/238U. The measurement time of AMS and SEM-TIMS was shorter than that of FT-TIMS and longer than that of SIMS. It is considered that AMS and SEM-TIMS have a certain development prospect, and it is necessary to research deeply.  相似文献   

9.
A low-energy photon detector was easily and accurately calibrated with plutonium sources of known isotopic contents after purification of the sources by anion exchange. Rapid data processing was attained by minicomputer calculations. Results obtained for plutonium abundances by λ-spectrometry and by mass spectrometry agreed within 1% for the 240Pu isotope, and within 10% for 238Pu and 241Pu at the concentrations normally present. Alpha specific activities calculated from the abundances obtained by the two methods agreed within 0.5%.  相似文献   

10.
Soil materials used were collected in the early 1970s at Idaho National Laboratory near the Subsurface Disposal Area (SDA). Samples from a depth of 0–4 and 4–8 cm at two different sites located on the northeast corner of the SDA perimeter were analyzed. The concentration of 234U, 235U, 236U, and 238U in soil digests were measured by mass spectrometry. Uranium isotopic composition of the soil at the two sample sites and depths is compared to previously measured concentrations of 238Pu, 239Pu, 240Pu, 241Pu, and 241Am. Implications for remediation of contaminated soils surrounding the SDA are discussed.  相似文献   

11.
234U of high isotopic purity (>99 atom%) as well as of high radiochemical, purity was separated from aged238Pu prepared by neutron irradiation of237Np. Methodologies based on ion exchange and solvent extraction procedures were used to achieve high decontamination factor from238Pu owing to the very high α-specific activity of238Pu (2800 times) in comparison to that of234U. Isotopic composition of purified234U was determined by thermal ionisation mass spectrometry. Alpha spectrometry was used for checking the radiochemical purity of234U with respect to concomitant α-emitting nuclides. The separated234U will be useful for different investigations using mass spectrometry and alpha spectrometry.  相似文献   

12.
Resonance ionization mass spectrometry (RIMS) is a very sensitive analytical technique for the detection of trace elements. This method is based on the excitation and ionization of atoms with resonant laser light followed by mass analysis. It allows element and, in some cases, isotope selective ionization and is applicable to most of the elements of the periodic table. A high selectivity can be achieved by applying three step photoionization of the elements under investigation and an additional mass separation for an unambiguous isotope assignment.An effective facility for resonance ionization mass spectrometry consists of three dye lasers which are pumped by two copper vapor lasers and of a linear time-of-flight spectrometer with a resolution better than 2500. Each copper vapor laser has a pulse repetition rate of 6.5 kHz and an average output power of 30 W.With such an apparatus measurements with lanthanide-, actinide-, and technetium-samples have been performed. By saturating the excitation steps and by using autoionizing states for the ionization step a detection efficiency of 4 × 10–6 and 2.5 × 10–6 has been reached for plutonium and technetium, respectively, leading to a detection limit of less than 107 atoms in the sample. Measurements of isotope ratios of plutonium samples were in good agreement with mass-spectrometric data. The high elemental selectivity of the resonance ionization spectrometry could be demonstrated.Presented in part at the 1989 European Winter Conference on Plasma Spectrochemistry, Reutte, Austria  相似文献   

13.
A combination of alpha-spectrometry, liquid scintillation counting (LSC) and accelerator mass spectrometry (AMS) was used for the determination of plutonium isotopes. 238Pu and 239+240Pu were measured by alpha-spectrometry after separation of Pu by anion-exchange using 236Pu tracer as recovery monitor. After alpha-measurement, one part of the sample was dissolved for determining 241Pu by LSC. Another part was used for the measurement of the 240Pu/239Pu atom ratio by AMS at VERA. Thus, it was possible to obtain complete information on the Pu isotopic composition of the samples. This method was applied to environmental reference samples and samples contaminated from nuclear reprocessing.  相似文献   

14.
Assays of alpha- and beta-emitting radionuclides in swipe samples are often required to monitor the presence of removable surface contamination for radiological protection and control in nuclear facilities. Swipe analysis has also proven to be a very sensitive analytical technique to detect nuclear signatures for safeguard verification purposes. A new sequential method for the determination of actinide isotopes and radiostrontium in swipe samples, which utilizes a streamlined column separation with stacked anion and extraction chromatography resins, has been developed. To validate the separation procedure, spike and blank samples were prepared and analyzed by inductively coupled mass spectrometry (ICP-MS), alpha spectrometry and liquid scintillation (LS) counting. Low detection limits have been achieved for isotopic analysis of Pu (238Pu, 239Pu, 240Pu, 241Pu), U (234U, 235U, 238U), Am (241Am), Cm (242Cm, 243/244Cm) and Sr (90Sr) at ultra-trace concentration levels in swipe samples.  相似文献   

15.
The paper presents the results of our study on 238Pu, 239Pu, 240Pu, 241Am and 90Sr concentration in human bones carried out on a set of 88 individual samples of central Europe origin. Bone tissue samples were retrieved under surgery while introducing hip joint implants. The conducted surgeries tend to cover either southern or northeastern parts of Poland. While for the southern samples only global fallout was expected to be seen, a mixed global and Chernobyl fallout were to be reflected in the others. Alpha spectrometry was applied to obtain activity concentration for 238Pu, 239+240Pu, 241Am, while liquid scintillation spectrometry for 90Sr and mass spectrometry to receive 240Pu/239Pu mass ratio. Surprisingly enough, and to the contrary to our expectations we could not see any significant differences in either Pu activity or Pu mass ratio between the studied populations. In both populations Chernobyl fraction proved marginal. The results on 90Sr and 241Am confirm similarities between the two examined groups.  相似文献   

16.
A systematic mass spectrometric study of two of the most common analgesic drugs, paracetamol and ibuprofen, is reported. The drugs were studied by means of secondary ion mass spectrometry (SIMS) and secondary neutral mass spectrometry (SNMS) using laser post-ionization (LPI) both in pure samples and in a two-component mixture. Ion suppression within the two-component system observed in SIMS mode is ameliorated using LPI under room temperature analysis. However, suppression effects are apparent in LPI mode on performing the analysis at cryogenic temperatures, which we attribute to changes in the desorption characteristics of sputtered molecules, which influences the subsequent post-ionization efficiency. This suggests different mechanisms of ion suppression in SIMS and LPI modes.
Figure
?  相似文献   

17.
This work describes a streamlined approach to the separation and purification of trace uranium and plutonium in environmental swipe samples that contain a small amount of collected bulk material. We describe key modifications to conventional techniques that result in a relatively rapid, safe, cost-effective, and efficient U and Pu separation process. Simulated samples were produced by loading appropriate 235U, 238U, and 240Pu onto high purity cotton swipes. Uranium concentration and isotopic composition were measured by multi-collector inductively coupled mass spectrometry. Corresponding plutonium measurements were conducted with a three stage thermal ionization mass spectrometer. Quantitative U and Pu recoveries were observed with this method.  相似文献   

18.
Simultaneous isotopic analysis of uranium and plutonium using thermal ionization mass spectrometer coupled to a multi-collector detection assembly with 9 Faraday cups has been reported earlier. Subsequently investigations have been carried out (1) to understand the applicability of correction methodologies available to account for the contribution of238Pu at238U and (2) to evaluate the effectiveness of these methodologies on the accuracy of235U/238U atom ratio being determined, particularly when samples containing different U/Pu atom ratios. Isotopic fractionation for both U and Pu in the simultaneous isotopic analysis has been compared with the results of the individual analysis of these elements. The different isotopic fractionation factors observed for U were attributed to different conditions of analysis. There was no significant difference in the isotopic fractionation patterns for Pu. The consideration to extend this method to actual samples from our observations on synthetic samples with diferent U/Pu atom ratios containing U and Pu isotopic reference standards is described.  相似文献   

19.
Determination of 238Pu in plutonium bearing fuels is required as a part of the chemical quality assurance of nuclear fuels. In addition, the determination of 238Pu is required in nuclear technology for many other applications, e.g., for developing isotope correlations and while using 238Pu as a spike (tracer) in isotope dilution α-spectrometry (IDAS). This determination usually involves the use of α-spectrometry on purified Pu sample. In view of the random errors associated with the counting statistics and the systematic errors due to (1) in-growth of 241Am in purified Pu sample and (2) tail contribution correction methodology in α-spectrometry, the precision and accuracy obtainable by α-spectrometry are limited. Thermal ionization mass spectrometry (TIMS) is generally used for the determination of different Pu isotopes other than 238Pu. This is due to the ubiquitous isobaric interference from 238U at 238Pu in TIMS. Recently, we have carried out studies on the formation of atomic and oxide ions of U and Pu by TIMS and developed a novel approach using interfering element correction methodology to account for the isobaric interference of 238U at 238Pu in TIMS. This methodology is based on the addition of 235U (enrichment >90 atom%) to Pu sample followed by the determination of 238U/235U atom ratio using UO+ ion and determination of Pu isotope ratios using Pu+ ion, from the same filament loading. The TIMS methodology was used for the determination of 238Pu in different Pu samples in U based nuclear fuels from PHWRs with 238Pu content about 0.2 atom%. The 238Pu determination was also carried out using α-spectrometry. This paper reports the results obtained by the two methods and presents the ments and shortcomings of the two approaches.  相似文献   

20.
Elemental and isotopic determination of americium and curium in spent nuclear fuels is necessary to validate neutronic calculation codes and for nuclear waste disposal purposes. Prior to mass spectrometric analysis, it is mandatory to perform separations in order to eliminate isobaric interferences between U, Pu, Am and Cm. In the spent fuels samples analyzed, a separation of U and Pu has been first realized with an anion-exchange resin. Then a rapid Am/Cm separation has been developed by high-performance liquid chromatography (HPLC) with an on-line detection using the Am and Cm α-emission. The influence of the different parameters on the chromatographic separation are described and discussed. Inductively coupled plasma mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) have been used to measure the isotopic composition of U, Am and Cm and to determine the 241Am/238U and 244Cm/238U ratios with the double spike isotope dilution method. The measurement procedures and the accuracy and precision of the results obtained with a quadrupole ICP-MS on different spent fuels samples are discussed and compared with those obtained by TIMS, used as a reference technique. Received: 30 November 1998 / Revised: 8 January 1999 / Accepted: 12 January 1999  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号