1.
We present the polymer poly-N-hydroxyethylacrylamide (PHEA) (polyDuramide) as a novel, hydrophilic, adsorbed capillary coating for electrophoretic protein analysis. Preparation of the PHEA coating requires a simple and fast (30 min) protocol that can be easily automated in capillary electrophoresis instruments. Over the pH range of 3-8.4, the PHEA coating is shown to reduce electroosmotic flow (EOF) by about 2 orders of magnitude compared to the bare silica capillary. In a systematic comparative study, the adsorbed PHEA coating exhibited minimal interactions with both acidic and basic proteins, providing efficient protein separations with excellent reproducibility on par with a covalent polyacrylamide coating. Hydrophobic interactions between proteins and a relatively hydrophobic poly-N,N-dimethylacrylamide (PDMA) adsorbed coating, on the other hand, adversely affected separation reproducibility and efficiency. Under both acidic and basic buffer conditions, the adsorbed PHEA coating produced an EOF suppression performance comparable to that of covalent polyacrylamide coating and superior to that of adsorbed PDMA coating. The protein separation performance in PHEA-coated capillaries was retained for 275 consecutive protein separation runs at pH 8.4, and for more than 800 runs at pH 4.4. The unique and novel combination of hydrophilicity and adsorptive coating ability of PHEA makes it a suitable wall coating for automated microscale analysis of proteins by capillary array systems.  相似文献   

2.
To stabilize electroosmotic flow (EOF) and suppress protein adsorption onto the silica capillary inner wall, a cationic hydroxyethylcellulose-graft-poly (poly(ethylene glycol) methyl ether methacrylate) (cat-HEC-g-PPEGMA) graft copolymer composed of cationic backbone and bottle brush-like side chains was synthesized for the first time and used as a novel physically adsorbed coating for protein separation by capillary electrophoresis. Reversed (anodal) and very stable EOF was obtained in cat-HEC-g-PPEGMA-coated capillary at pH 2.2-7.8. The effects of degree of cationization, PEGMA grafting ratio, PEGMA molecular mass, and buffer pH on the separation of basic proteins were investigated. A systematic comparative study of protein separation in bare and HEC-coated capillaries and in cat-HEC-g-PPEGMA-coated capillary was also performed. The basic proteins can be well separated in cat-HEC-g-PPEGMA-coated capillary over the pH range of 2.8-6.8 with good repeatability and high separation efficiency, because the coating combines good protein-resistant property of bottle brush-like PPEGMA side chains with excellent coating ability of cat-HEC backbone. Besides its success in separation of basic proteins, the cat-HEC-g-PPEGMA coating was also superior in the fast separation of other protein samples, such as protein mixture, egg white, and saliva, which indicates that it is a promising coating for further proteomics analysis.  相似文献   

3.
In this work, a new physically adsorbed coating for capillary electrophoresis (CE) is presented. The coating is based on a N,N-dimethylacrylamide-ethylpyrrolidine methacrylate (DMA-EPyM) copolymer synthesized in our laboratory. The capillary coating is simple and easy to obtain as only requires flushing the capillary with a polymer aqueous solution for 2 min. It is shown that by using these coated capillaries the electrostatic adsorption of a group of basic proteins onto the capillary wall is significantly reduced allowing their analysis by CE. Moreover, the DMA-EPyM coating provides reproducible separations of the basic proteins with RSD values for migration times lower than 0.75% for the same day (n = 5) and lower than 3.90% for three different days (n = 15). Interestingly, the electrical charge of the coated capillary wall can be modulated by varying the pH of the running buffer which makes possible the analysis of basic and acidic proteins in the same capillary. The usefulness of this coating is further demonstrated via the reproducible separation of whey (i.e. acidic) proteins from raw milk. The coating protocol should be compatible with both CE in microchips and CE-MS of different types of proteins.  相似文献   

4.
In this work, a comparative study on the use of different polymers as physically adsorbed coatings for CE is presented. It is demonstrated that the use of ad hoc synthesized polymers as coatings allows tailoring the EOF in CE increasing the flexibility of this analytical technique. Namely, different polymers were synthesized at our laboratory using different percentages of ethylpyrrolidine methacrylate (EpyM) and N,N-dimethylacrylamide (DMA). Thus, by modifying the percentage of EpyM and DMA monomers it is possible to manipulate the positive charge of the copolymer, varying the global electrical charge on the capillary wall and with that the EOF. These coated capillaries are obtained by simply flushing a given EpyM-DMA aqueous solution into bare silica capillaries. It is shown that by using these coated capillaries at adequate pHs, faster or more resolved CE separations can be achieved depending on the requirements of each analysis. Moreover, it is demonstrated that these coated capillaries reduce the electrostatic adsorption of basic proteins onto the capillary wall. Furthermore, EpyM-DMA coatings allow the reproducible chiral separation of enantiomers through the partial filling technique (PFT). The EpyM-DMA coated capillaries are demonstrated to provide reproducible EOF values independently of the pH and polymer composition with%RSD values lower than 2% for the same day. It is also demonstrated that the coating procedure is reproducible between capillaries. The compatibility of this coating protocol with CE in microchips is discussed.  相似文献   

5.
A novel pH‐responsive coating technique was developed and applied to CE successfully in this paper. The coating was formed by bonding mixed opposite charge poly(acrylic acid) and poly(2‐vinylpyridine) randomly onto the inner wall of a silica capillary. The coating processes were first characterized by ellipsometry and atomic force microscopy at macroscale and microscale, respectively. Measurements of EOF were implemented to confirm the coating. Direction and velocity of EOF became controllable from negative to positive, showing a perfect sigmoidal curve as the coating net charges alternated by the pH of BGE. The control of the EOF makes it possible to analyze different kinds of small molecules, peptides, and proteins successfully in the same capillary. Results showed that the stability and reproducibility for separations of fluoroquinolone standards were satisfactory for more than a hundred separations. A series of basic and acidic protein standards were separated with admirable efficiency and minimal adsorption using both polarities. The separation of tryptic BSA digest showed that the prepared capillary has immense potential in analyzing a single sample with both acidic and basic separations, which achieved the expectation in proteomics study by CE‐MS.  相似文献   

6.
A brush-like copolymer consisting of poly(ethylene glycol) methyl ether methacrylate and N,N-dimethylacrylamide (PEGMA-DMA) was synthesized and used as a novel static physically adsorbed coating for protein separation by capillary electrophoresis for the first time, in order to stabilize electroosmotic flow (EOF) and suppress adsorption of proteins onto the capillary wall. Very stable and low EOF was obtained in PEGMA-DMA-coated capillary at pH 2.2-7.8. The effects of molar ratio of PEGMA to DMA, copolymer molecular mass, and pH on the separation of basic proteins were discussed. A comparative study of bare capillary with PEGMA-DMA-coated capillary for protein separation was also performed. The basic proteins could be well separated in PEGMA-DMA-coated capillary over the investigated pH range of 2.8-6.8 with good repeatability and high separation efficiency because the copolymer coating combines good protein-resistant property of PEG side chains with excellent coating ability of PDMA-contained backbone. Finally, the coating was successfully applied to the fast separation of other protein samples, such as protein mixture and egg white, which reveals that it is a potential coating for further proteomics analysis.  相似文献   

7.
In this work, the properties of four cationic copolymers synthesized in our laboratory are studied as physically adsorbed coatings for capillary electrophoresis (CE). Namely, the four copolymers investigated were poly(N-ethyl morpholine methacrylamide-co-N,N-dimethylacrylamide), poly(N-ethyl pyrrolidine methacrylate-co-N,N-dimethylacrylamide), poly(N-ethyl morpholine methacrylate-co-N,N-dimethylacrylamide) and poly(N-ethyl pyrrolidine methacrylamide-co-N,N-dimethylacrylamide). Capillaries were easily coated using these four different macromolecules by simply flushing into the tubing an aqueous solution containing the copolymer. The stability and reproducibility of each coating were tested for the same day, different days and different capillaries. It is demonstrated that the use of these coatings in CE can drastically reduce the analysis time, improve the resolution of the separations or enhance the analysis repeatability at very acidic pH values compared to bare silica columns. As an example, the analysis of an organic acids test mixture revealed that the analysis time was reduced more than 6-times whereas the separation efficiency was significantly increased to nearly 10-times attaining values up to 595,000 plates/m using the coated capillaries. Moreover, it was shown that all the copolymers used as coatings for CE allowed the separation of basic proteins by reducing their adsorption onto the capillary wall. Links between their molecular structure, physicochemical properties and their performance as coatings in CE are discussed.  相似文献   

8.
In this work, a new copolymer synthesized in our laboratory is used as physically adsorbed coating for capillary electrophoresis (CE). The copolymer is composed of ethylpyrrolidine methacrylate (EPyM) and methylmethacrylate (MMA). The capillary coating is easily obtained by simply flushing into the tubing an EPyM/MMA solution. It is demonstrated that the composition of the EPyM/MMA copolymer together with the selection of the background electrolyte (BGE) and pH allow tailoring the direction and magnitude of the electroosmotic flow (EOF) in CE. It is also shown that the EOF obtained for the EPyM/MMA-coated capillaries was reproducible in all cases independently on pH or polymer composition. Thus, RSD values lower than 1.9% (n=5) for the same capillary and day were obtained for the migration time, while the repeatability interdays (n=5) was observed to provide RSD values lower than 0.5%. The stability of the coating procedure was also tested between capillaries (n=3) obtaining RSD values lower than 0.6%. It is demonstrated with several examples that the use of EPyM/MMA coatings in CE can drastically reduce the analysis time and/or to improve the resolution of the separations. It is shown that EPyM/MMA-coated capillaries allow the separation of basic proteins by reducing their adsorption onto the capillary wall. Also, EPyM/MMA-coated capillaries provide a faster separation of samples containing simultaneously positive and negative analytes. Moreover, it is demonstrated that the use of EPyM/MMA-coated capillaries can incorporate an additional chromatographic-like interaction with nucleosides that highly improves the separation of this group of solutes.  相似文献   

9.
毛细管电泳具有分析时间短,分离效率高,样品消耗量少等优点,在生物样品分离,特别是蛋白质分析领域有重要应用。然而,毛细管内壁硅羟基的解离给分离结果带来诸多不良影响。聚合物涂层能够抑制蛋白质在毛细管内壁的吸附以及调控电渗流,故对毛细管内壁进行有效修饰能够提高其对蛋白质的分离效率及分离稳定性。该文主要综述了动态及静态聚合物涂层毛细管的最新研究进展,并概述了近些年基于多巴胺/聚多巴胺发展起来的涂层毛细管的研究进展,最后展望了聚合物涂层毛细管的发展趋势。  相似文献   

10.
Positively charged starch derivatives were used to modify the inner surface of fused-silica capillaries by addition to running buffer, which were subsequently employed in capillary electrophoresis (CE). Capillaries coated with the cationic starch derivatives were shown to generate a stable, reversed electroosmotic flow (EOF) in the investigated pH range of 3-9. The presented coating procedure was fast, based on a simple rinsing protocol where the polymer created a physically adsorbed, cationic polymer layer. Among the additives studied, a quaternary ammonium starch derivative showed a fast EOF mobility and effectively suppressed the adsorption of proteins. The intra- and inter-day reproducibility of the coating referring to the EOF mobility were satisfactory with relative standard deviation (RSD) of 0.27 and 1.67%, respectively. The coating enabled separation of some protein mixtures including basic proteins within l3 min with efficiencies up to 280,000 plates/m. In addition, this cationic starch derivative possessed a good solubility (about 100mg/mL), and it does not significantly contribute to the background adsorption in the UV region of 190-400 nm.  相似文献   

11.
A fast method for the generation of permanent hydrophilic capillary coatings for capillary electrophoresis (CE) is presented. Such interior coating is effected by treating the surface to be coated with a solution of glutaraldehyde as cross-linking agent followed by a solution of poly(vinyl alcohol) (PVA), which results in an immobilization of the polymer on the capillary surface. Applied for capillary zone electrophoresis (CZE) such capillaries coated with cross-linked PVA exhibit excellent separation performance of adsorptive analytes like basic proteins due to the reduction of analyte-wall interactions. The long-term stability of cross-linked PVA coatings could be proved in very long series of CZE separations. More than 1000 repetitive CE separations of basic proteins were performed with stable absolute migration times relative standard deviation (RSD > 1.2%) and without loss of separation efficiency. Cross-linked PVA coatings exhibit a suppressed electroosmotic flow and excellent stability over a wide pH range.  相似文献   

12.
Capillary electrophoresis (CE) was coupled off-line with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the analysis of proteins and peptides. CE fractions were collected directly on a matrix-coated MALDI target, using a sheath-flow interface. Protein adsorption during CE separations was prevented by coating the capillaries with the physically adsorbed, cationic polymer PolyE-323. The CE/MALDI-MS system was used for the analysis of model proteins and peptides at physiological pH as well as analysis of proteins in tear fluid. Moreover, tryptic on-target digestion of the collected protein fractions, with subsequent MALDI-MS and MS/MS peptide analysis, was demonstrated.  相似文献   

13.
A new physically adsorbed capillary coating for capillary electrophoresis-mass spectrometry (CE-MS) of basic proteins is presented, which is easily obtained by flushing the capillary with a polymer aqueous solution for two min. This coating significantly reduces the electrostatic adsorption of a group of basic proteins (i.e., cytochrome c, lysozyme, and ribonuclease A) onto the capillary wall allowing their analysis by CE-MS. The coating protocol is compatible with electrospray inonization (ESI)-MS via the reproducible separation of the standard basic proteins (%RSD values (n = 5) < 1% for analysis time reproducibility and < 5% for peak heights, measured from the total ion electropherograms (TIEs) within the same day). The LODs determined using cytochrome c with total ion current and extracted ion current defection were 24.5 and 2.9 fmol, respectively. Using this new coating lysozymes from chicken and turkey egg white could be easily distinguished by CE-MS, demonstrating the usefulness of this method to differentiate animal species. Even after sterilization at 120 degrees C for 30 min, lysozyme could be detected, as well as in wines at concentrations much lower than the limit marked by the EC Commission Regulation. Adulteration of minced meat with 5% of egg-white could also be analysed by our CE-MS protocol.  相似文献   

14.
Analysis reproducibility and detection sensitivity of capillary electrophoresis (CE) are often questioned by applied scientists, which has hindered its application as a routine method. To address these issues, a simple, precise, and reproducible dynamic coating method was developed by applying carboxymethyl chitosan (CMC) dynamic coating on fused silica capillary. The proposed coating was accomplished by simply rinsing the capillary with CMC solution for 1 min in between runs, with no regeneration procedure or buffer additives needed. Electroosmotic flow could be well controlled by adjusting the pH of background electrolyte, and the adsorption of analytes onto the capillary inner wall was effectively eliminated. The main parameters of the coating condition were optimized, and extensive applications of these CMC-dynamically coated capillaries in CE separations were then firmly confirmed. By using proteins, aristolochic acids, and inorganic anions as model analytes, the coating showed a good stability, high reproducibility, as well as improved sensitivity. Baseline separations could be obtained with high efficiency. The reduced adsorption was impressively effective for basic proteins, with an average plate number of 90,000/m for each protein, apart from the good resolution on the chromatogram. A high sensitive detection of α-lactalbumin was achieved with a limit of detection (S/N = 3) of 3.5 nM, and the number of theoretical plates was as high as 1,200,000/m. In addition, the combination of the CMC coating with nonaqueous CE and CE-mass spectrometry proved to be practical. All results showed that the CMC-dynamically coated capillary has special properties and obvious superiority over the uncoated ones for CE analysis.  相似文献   

15.
王雨晨  王延梅 《色谱》2020,38(9):1022-1027
毛细管电泳作为一种常见的液相分离技术,因其分析速度快、分离效率高、样品消耗量少等特点,在蛋白质分离分析领域有广泛应用。然而,常用的熔融硅毛细管容易吸附蛋白质,导致电渗流不稳定,分离结果重现性变差;此外,商用毛细管电泳中常用的紫外检测器由于光程短,使得毛细管电泳的检测灵敏度往往不能达到低丰度蛋白质的直接分析要求。因此寻找能够阻止蛋白质吸附、同时能够提高检测灵敏度的涂层是毛细管电泳分离分析蛋白质的重要课题之一。聚(2-甲基-2-噁唑啉)(PMOXA)作为一种类肽类亲水性聚合物,具有与抗蛋白质吸附聚合物聚乙二醇类似的亲水性、抗蛋白质吸附性和生物相容性,而且其类肽结构使之具有较聚乙二醇更好的稳定性,因此近年来在生物质传递、药物载体和阻抗蛋白质吸附等领域得到越来越多的应用。该文主要从两个方面对聚(2-甲基-2-噁唑啉)在毛细管电泳中的应用进行了阐述。一是利用多巴胺作为黏合层将其涂覆在毛细管内壁作为抗蛋白质吸附涂层,这种涂层不仅能成功分离多种蛋白质的混合物(如溶菌酶、细胞色素C、核糖核酸酶A和α-胰凝乳蛋白酶原A),而且在定量检测奶粉中三聚氰胺、乳铁蛋白的过程中,能阻抗其他蛋白质的非特异性吸附,提高了毛细管电泳对奶粉中三聚氰胺、乳铁蛋白的检测效率。二是将其与具有刺激响应性的聚合物(如聚丙烯酸)构成二元混合刷涂层,在一定的pH和离子强度条件下,涂层可吸附目标蛋白质(如牛血清白蛋白、溶菌酶),在另一pH和离子强度条件下可将吸附的目标蛋白质全部释放,同时在释放过程中,处于涂层表面的聚(2-甲基-2-噁唑啉)会进一步阻止蛋白质的吸附,释放的蛋白质在电渗流和电泳的双重作用下快速迁移,到达检测器的蛋白质瞬时浓度大大增加,使目标蛋白质得到富集,目标蛋白质的检测信号得到放大,从而达到了提高低丰度蛋白质检测灵敏度的目的。此外,该文还对聚(2-甲基-2-噁唑啉)在毛细管电泳分离蛋白质中的未来发展趋势进行了展望。  相似文献   

16.
In this work, the suitability of a new polymer family has been investigated as capillary coatings for the analysis of peptides and basic proteins by CE. This polymer family has been designed to minimize or completely prevent protein–capillary wall interactions and to modify the EOF. These coating materials are linear polymeric chains bearing as side cationizable moiety a dentronic triamine derived from N,N,N’,N’‐tetraethyldiethylenetriamine (TEDETA), which is linked to the backbone through a spacer (unit labeled as TEDETAMA). Four different polymers have been prepared and evaluated: a homopolymer which comprised only of those cationizable repetitive units of TEDETAMA, and three copolymers that randomly incorporate TEDETAMA together with neutral hydrosoluble units of N‐(2‐hydroxypropyl) methacrylamide (HPMA) at different molar percentages (25:75, 50:50 and 75:25). It has been demonstrated that the composition of the copolymers influences the EOF and therefore the separation of the investigated biopolymers. Among the novel polymers studied, poly‐(TEDETAMA‐co‐HPMA) 50:50 copolymer was successfully applied as coating material of the inner capillary surface in CE‐UV and CE‐MS, providing EOF reversing together with fast and efficient baseline separation of peptides and basic proteins. Finally, the feasibility of the polymer‐coated capillary was shown through the analysis of lysozyme in a cheese sample.  相似文献   

17.
Quasi‐interpenetrating network (quasi‐IPN) of linear polyacrylamide (LPA) with low molecular mass and poly(N,N‐dimethylacrylamide) (PDMA), which is shown to uniquely combine the superior sieving ability of LPA with the coating ability of PDMA, has been synthesized for application in dsDNA and basic protein separation by CE. The performance of quasi‐IPN on dsDNA separation was determined by polymer concentration, electric field strength, LPA molecular masses and different acrylamide (AM) to N,N‐dimethylacrylamide (DMA) ratio. The results showed that all fragments in Φ×174/HaeIII digest were achieved with a 30 cm effective capillary length at –6 kV at an appropriate polymer solution concentration in bare silica capillaries. Furthermore, EOF measurement results showed that quasi‐IPN exhibited good capillary coating ability, via adsorption from aqueous solution, efficiently suppressing EOF. The effect of the buffer pH values on the separation of basic proteins was investigated in detail. The separation efficiencies and analysis reproducibility demonstrated the good potentiality of quasi‐IPN matrix for suppressing the adsorption of basic proteins onto the silica capillary wall. In addition, when quasi‐IPN was used both as sieving matrix and dynamic coating in bare silica capillaries, higher peak separation efficiencies, and better migration time reproducibility were obtained.  相似文献   

18.
The capillary walls of fused-silica capillary electrophoresis (CE) columns were modified with a thin film of polyaniline (PANI), providing open-tubular columns with a stable coating containing aromatic groups and amine functionalities. Fast and efficient separations were observed for small bioactive peptides under acidic conditions on PANI-coated columns. The mechanism of separation is based on hydrophobic interactions between the analytes and the polymeric matrix. Good reproducibility was observed from run-to-run. Due to the simple derivatization procedure, method flexibility, the uniformity of the coating and its stability, conjugated polymers could find practical application in capillary zone electrophoresis (CZE) separations.  相似文献   

19.
Zhang J  Tran NT  Weber J  Slim C  Viovy JL  Taverna M 《Electrophoresis》2006,27(15):3086-3092
The potential of a series of newly synthesized poly(N,N-dimethylacrylamide) (PDMA) grafted polyacrylamide (PAM) copolymers (P(AM-PDMA)) as a replaceable separation medium for protein analysis was studied. A comparative study with and without copolymers was performed; the separation efficiency, analysis reproducibility and protein recovery proved that the P(AM-PDMA) copolymers were efficient in suppressing the adsorption of basic proteins onto the silica capillary wall. Furthermore, the size-dependent retardation of native proteins in a representative P(AM-PDMA) copolymer was demonstrated by Ferguson analysis. The results showed that the P(AM-PDMA) copolymers combine the good coating property of PDMA and the sieving property of PAM and could be applied as a sieving matrix for the analysis of native proteins.  相似文献   

20.
CE offers the advantage of flexibility and method development options. It excels in the area of separation of ions, chiral, polar and biological compounds (especially proteins and peptides). Masking the active sites on the inner surface of a bare fused silica capillary wall is often necessary for CE separations of basic compounds, proteins and peptides. The use of capillary surface coating is one of the approaches to prevent the adsorption phenomena and improve the repeatability of migration times and peak areas of these analytes. In this study, new capillary coatings consisting of (i) derivatized polystyrene nanoparticles and (ii) derivatized fullerenes were investigated for the analysis of peptides and protein digest by CE. The coated capillaries showed excellent run‐to‐run and batch‐to‐batch reproducibility (RSD of migration time ≤0.5% for run‐to‐run and ≤9.5% for batch‐to‐batch experiments). Furthermore, the capillaries offer high stability from pH 2.0 to 10.0. The actual potential of the coated capillaries was tested by combining CE with MALDI‐MS for analysing complex samples, such as peptides, whereas the overall performance of the CE‐MALDI‐MS system was investigated by analysing a five‐protein digest mixture. Subsequently, the peak list (peptide mass fingerprint) generated from the mass spectra of each fraction was entered into the Swiss‐Prot database in order to search for matching tryptic fragments using the MASCOT software. The sequence coverage of analysed proteins was between 36 and 68%. The established technology benefits from the synergism of high separation efficiency and the structure selective identification via MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏