首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
The structural and functional properties of Citrus grandis Osbeck (CGO) seed mucilage by different extraction practices, including conventional citrate buffer, ultrasonic-assisted (UAE), enzymatic-assisted extraction (EAE) with cellulase or Celluclast® 1.5 L and various ultrasonic-assisted enzymatic extraction (UAEE) procedures were investigated. It was found that CGO seed from agricultural and processing byproducts is an excellent new source of high methoxyl pectin with quite high intrinsic viscosity (about 108.64 dL/g) and molecular weight (about 1.9 × 106) as compared with other pectin sources. UAEE with Celluclast® 1.5 L enhanced the extraction yield most pronouncedly (about 2.3 times). Moreover, the monosaccharide composition of CGO seed mucilage is least affected by EAE with Celluclast® 1.5 L. In contrast, EAE with cellulase dramatically reduces the galacturonic acid (GalA) content to less than 60 molar%, and increases the glucose (Glc) content pronouncedly (to about 40 molar%), which may be considered as an adverse effect in terms of pectin purity. Though extraction procedures involved with ultrasound and cellulolytic enzymes generally show a decrease in GalA contents, weight average molar mass and intrinsic viscosity, EAE with Celluclast® 1.5 L is least affected, followed by UAE and UAEE with Celluclast® 1.5 L. These features can be leveraged in favor of diversified applications.  相似文献   

2.
A comparison of four extraction techniques used for the isolation of 14 explosive compounds (Method 8330-Explosives) from spiked soil samples is described. Soxhlet warm extraction (SWE), pressurized solvent extraction (PSE), microwave assisted extraction (MAE) and supercritical fluid extraction (SFE) were included. The effects of basic extraction conditions – i.e. type of extraction solvent, temperature, pressure, and extraction time – were investigated. The best extraction recovery of the monitored compounds from spiked soil was obtained using pressurized solvent extraction. Recoveries of explosives using the PSE technique were in the range from 65 to 112%. Extraction recoveries by Soxhlet warm extraction and supercritical fluid extraction reached 65–99% and 52–75%, respectively. The lowest extraction recoveries (28–65%) were obtained using microwave assisted extraction. A very low extraction recovery for tetryl was observed in all cases but the best results were achieved by pressurized solvent extraction (58%).  相似文献   

3.
固相萃取技术在食品痕量残留和污染分析中的应用   总被引:3,自引:0,他引:3  
Li G  Ma G 《色谱》2011,29(7):606-612
食品痕量残留和污染分析中,样品的前处理极为重要,也是其难点所在。由于食品和农产品样品的多样性和复杂性,目前还没有一种前处理技术能够适合所有情况下的所有样品。本文对近年来发展起来的新型固相萃取技术如固相微萃取、搅拌棒吸附萃取、基质固相分散萃取、分子印迹固相萃取、免疫亲和固相萃取、整体柱固相萃取、碳纳米管固相萃取等在食品痕量残留和污染分析中的应用进行了综述,对未来的发展前景作了展望。  相似文献   

4.
Abstract

Surfactant-mediated extraction (SME), pressurized liquid extraction (PLE), and enzyme-assisted extraction (EAE) have been compared to improve the isolation of phlorotannins from the brown algae Lobophora variegata. Enzymatic treatment with Alcalase 2.4?L FG, Carezyme 4500?L, protease from Streptomyces griseus, pectinase from Aspergillus niger, Celluclast 1.5?L, protease from Bacillus licheniformis; surfactant extraction with triacetin and guaiacol and PLE with ethanol:water as extracting solvent, have been studied in terms of total phenolic content by the Folin–Ciocalteu method and total phlorotannin content using the DMBA assay. The results showed that SME yields the highest amount of phenols and phlorotannins by using food grade guaiacol as the surfactant. An extraction protocol was developed to maximize the amount of extract obtained from L. variegata. The effects of various parameters such as the type of surfactant, efficacy of surfactant, and optimum pH, on the extraction efficiency of polyphenols were examined. The simultaneous use of the enzyme and surfactant was also investigated. However, a synergistic effect between the enzymes and the surfactant for the extraction of polyphenols has not been observed. Considering total phenols and total phlorotannins in the extract, the extraction yield were obtained for total phenols as SME?>?EAE?>?PLE and for total phlorotannins as SME?>?PLE?>?EAE.  相似文献   

5.
Polychlorinated biphenyls (PCBs) and chlorobenzenes (CBzs) are two classes of dioxin precursors formed in municipal solid waste incinerators (MSWIs); they produce negative health effects similar to those of dioxins. Reducing the analytical time required for determining the concentrations of these compounds in MSWIs is important for quickly evaluating their importance and assessing associated health risks. In the present study, water is used as a safe and environmentally friendly solvent in microwave-assisted extraction (MAE) for PCB and CBz analyses. MAE is compared with traditional Soxhlet extraction (SE) to determine the extraction efficiencies. The evaluation of extraction efficiencies shows that MAE has a high extraction efficiency compared with that of SE when water content is lower than 60%. Furthermore, the extraction time and organic solvent consumption are reduced with MAE compared with SE.  相似文献   

6.
The demand for mechanical recycling of plastic waste results in an increasing amount of recycled polymeric materials available for development of new products. In order for recycled materials to find their way into the material market, high quality is demanded. Thereby, a complete and closed loop of polymeric materials can be achieved successfully. The concept of high quality for recycled plastics imply that besides a pure fraction of e.g. polyethylene (PE) or polypropylene (PP), containing only minor trace amount of foreign plastics, knowledge is required about the type and amount of low molecular weight (LMW) compounds. During long-term use (service-life), products made of polymeric materials will undergo an often very slow degradation where a series of degradation products are formed, in parallel, additives incorporated in the matrix may also degrade. These compounds migrate at various rates to the surrounding environment. The release rate of LMW products from plastics depends on the initiation time of degradation and the degradation mechanisms. For polymers the formation of degradation products may be initiated already during processing, and subsequent use will add products coming from the surrounding environment, e.g. fragrance and aroma compounds from packaging. During recycling of plastics, emissions which contain a series of different LMW compounds may reach the environment leading to unwanted exposure to additives and their degradation residues as well as degradation products of polymers.Several extraction techniques are available for sampling of LMW compounds in polymers before chromatographic analysis. This paper reviews and compares polymer dissolution, accelerated solvent extraction (ASE), microwave assisted extraction (MAE), ultrasound assisted extraction (UAE), super critical fluid extraction (SFE), soxhlet extraction, head-space extraction (HS), head-space solid phase micro extraction (HS-SPME), and head-space stir bar sorptive extraction (HSSE) as appropriate sampling methods for LMW compounds in recycled polymers. Appropriate internal standards useful for these kinds of matrices were selected, which improved the possibility for later quantification. Based on the review of extraction methods, the most promising techniques were tested with industrially recycled samples of HDPE and PP and virgin HDPE and PP for method comparison.  相似文献   

7.
Microwave-assisted extraction using 1 M KOH/methanol (alkaline-MAE) in combination with solid-phase extraction treatment was developed and applied to polycyclic aromatic hydrocarbons (PAHs) in a sediment sample. Although various conditions were examined (100 or 150 °C for 10 or 30 min), comparable concentrations of PAHs to those obtained by conventional extraction with 1 M KOH/methanol at 70 °C for 4 h were obtained, even at 100 °C for 10 min. The concentrations obtained by using MeOH at 150 °C for 30 min without KOH were lower (by 1.3-37%) than those obtained by alkaline-MAE at 150 °C for 30 min. Since the developed technique can introduce higher concentration of benzo[ghi]perylene relative to those using pressurized liquid extraction (toluene, 150 °C, 15 MPa, 10 min, two cycles), the developed alkaline-MAE is a effective technique.  相似文献   

8.
《Analytical letters》2012,45(8):1434-1447
The use of disposable pipette extraction was examined for the simple and rapid determination of seven high explosives (cyclotrimethyl-enetrinitramine, cyclotetramethyl-enetetranitramine, 2,4,6-trinitrophenyl-methylnitramine, 2,4,6-trinitrotoluene, 2,4-dinitrotoluene, nitroglycerin, and pentaerythritol tetranitrate) in water. The current study involved the determination of slightly polar and nonpolar explosives in water with a reversed phase sorbent followed by high performance liquid chromatography. The method was based on a styrene divinylbenzene sorbent loosely placed inside a 5-mL pipette tip. Water samples were drawn into the tip and mixed with the sorbent. Air bubbles were also drawn through the tip following sample solution to enhance mixing. Because disposable pipette extraction uses small amounts of sorbent, minimal solvent is required to elute analytes and solvent evaporation is not necessary. The method provided rapid sample preparation, and required less than five minutes to extract 1.0 mL of water sample in the current study. Matrix-matched calibration was performed, and the limits of detection (LOD) were determined to be below 0.1 µg mL?1 for all targeted explosives in water with an enrichment factor of two. Coefficients of determination (r2) were greater than 0.9990 for all studied explosives, and the recoveries ranged from 69.76% to 87.51%, 83.77% to 91.25%, and 83.62% to 98.99% for samples spiked at 0.25 µg mL?1, 1.0 µg mL?1, and 5.0 µg mL?1, respectively. The relative standard deviations of recoveries at all spiked levels were below 8.97%. These results indicate that the disposable pipette extraction method provided good accuracy and precision for the determination of explosives in water.  相似文献   

9.
作为一种新型非金属材料,石墨相氮化碳以其独特的优点,如简单的制备方法、优良的化学及热稳定性、良好的生物兼容性和无毒性等,受到越来越多的关注。石墨相氮化碳及其复合材料目前已被广泛应用于电催化、光催化、生物成像等领域。由于具有大的比表面积,同时又是富电子的疏水材料,石墨相氮化碳相关材料被认为是一种理想的样品前处理吸附剂。该文探讨了近年来石墨相氮化碳及其复合材料作为固相萃取、分散固相萃取、磁性固相萃取、固相微萃取吸附剂在样品前处理中的应用,并对未来的发展趋势和应用前景进行了展望,以期为相关领域的研究提供帮助。  相似文献   

10.
The comparison of four extraction techniques for isolation of five native and one labelled steroid oestrogens from sediment was described. The three conventional extraction techniques Soxhlet warm extraction (SWE), accelerated solvent extraction (ASE), microwave-assisted extraction (MAE) and a promising technique QuEChERS were tested for isolation of low environmentally relevant oestrogen concentrations using different extraction conditions. The least expensive and time-consuming method QuEChERS provided the best extraction recoveries (53–84%) from all techniques. MAE achieved the highest recovery from conventional techniques for less polar oestrogens using dichloromethane: acetone 3:1 mixture as an extraction solvent (50–71%), but for extraction of the whole group of oestrogens including more polar estriol acetone or methanol must be used. ASE provided higher extraction recoveries using dichloromethane at 60°C (53–74%) for less polar oestrogens. However, the repeatability of results was unsatisfactory and recoveries using other extraction conditions were lower than for MAE. The most time-consuming SWE achieved the worst extraction recoveries and for isolation of low oestrogen concentrations from sediments, it is completely unsuitable.  相似文献   

11.
提出一种准确、高效测定土壤中乙草胺的分析方法。优化方法后,土壤样品经过预处理,加速溶剂萃取(ASE),固相萃取柱(SPE)净化,样液经气相色谱串联质谱仪(GC-MS/MS)测定,用空白样品基质液配标,浓度在0.005~0.2μg/mL范围内,线性相关系数达0.9998。对空白土壤样品进行0.5,5,20μg/kg 3个水平加标(n=6),平均回收率为89.3%~102.1%,RSD范围为2.9%~4.1%。此方法可用于实际样品测定。  相似文献   

12.
The aim of this research is to compare two continuous extraction technologies, intermittent counter-current extraction (ICcE) and dual flow counter-current chromatography (DFCCC), in terms of loading and throughput using the GUESSmix, and show the advantages and disadvantages of the two methods. A model sample containing caffeine, vanillin, naringenin and carvone, with a total load of 11.2 g, was employed with a hexane-ethyl acetate-methanol-water (2:3:2:3) phase system to evaluate an ICcE method on a preparative (912 ml coil volume) DE-Midi instrument. While DFCCC was carried out on a specially designed preparative (561 ml coil volume) bobbin installed in a similar Midi instrument case. While similar throughputs of 7.8 g/h and 6.9 g/h were achieved for the ICcE and DFCCC methods respectively, ICcE was demonstrated to have a number of advantages over DFCCC.  相似文献   

13.
钱海龙  严秀平 《色谱》2020,38(1):22-27
作为一类新型多孔晶体材料,金属有机骨架(MOFs)在储能、催化、传感和分离等领域得到了广泛应用。MOFs多样的拓扑结构、大的比表面积和可调的孔径使得其在样品前处理领域拥有广阔的应用前景,基于MOFs及其衍生材料的样品预处理新方法层出不穷。该文总结了近几年MOFs粉末、MOFs膜、MOFs纳米片和MOFs复合材料等应用于固相萃取、固相微萃取和磁固相萃取等样品前处理技术的研究进展,并对该领域研究进行了展望。  相似文献   

14.
魏丹  国明  吴慧珍  张菊 《色谱》2020,38(8):945-952
建立了加速溶剂萃取(ASE)、磁固相萃取净化(MSPE)、气相色谱-质谱(GC-MS)测定土壤中多环芳烃和有机氯残留的方法。ASE萃取溶剂为丙酮-正己烷(1:1,v/v),萃取温度为100℃,萃取压力为11.032 MPa,加热时间为5 min,静态萃取时间为5 min,循环萃取3次,冲洗体积为60%萃取池体积,氮气吹扫100 s。然后采用室温制备法自制ZIF-8/nZVI磁性材料用于净化萃取液,将净化液浓缩定容后进行GC-MS测定。多环芳烃和有机氯的线性范围为5~200 μg/kg,线性相关系数(r2)均大于0.99;目标物的检出限(LOD,S/N=3)为0.04~1.21 μg/kg。所建方法成功用于土壤样品中16种多环芳烃和23种有机氯的测定,在3个加标水平下得到的加标回收率为63.9%~112.1%,相对标准偏差(RSD)为0.4%~26.2%。研究结果表明,该方法具有灵敏度高、重现性好、回收率高等特点,适用于土壤中多环芳烃和有机氯残留的检测。  相似文献   

15.
赵新颖  屈锋  覃浩  罗爱芹 《色谱》2014,32(6):600-603
双水相萃取是一种新型的液-液萃取技术,具有方法简单,易操作,成本低,易放大,条件温和,可保持蛋白质活性等明显优势,特别适用于生物样品的前处理和组分分离。本文建立了15% PEG-4000/8% NaH2PO4双水相体系,通过两次双水相萃取结合高效液相色谱法(HPLC)分离了唾液中的多种蛋白质。经过双水相萃取,对上、下两相中的蛋白质进行色谱的梯度洗脱分析。50 min内蛋白质的色谱峰可分为10组,根据其在上、下两相的分配规律还可划分为6个组分区。结果表明,两次双水相萃取结合HPLC可以实现唾液中的蛋白质的选择性分离。该法为复杂生物样品中的蛋白质多维度、选择性分离和分析提供了新的思路。  相似文献   

16.
孟志超  张璐  黄艳凤 《色谱》2018,36(3):216-221
金属有机骨架(MOFs)材料是近几年涌现出的一类新型多功能多孔材料,以金属离子或金属簇为配位中心,与含氧或氮的有机配体通过配位作用形成多孔骨架结构。相比于其他传统无机多孔材料,MOFs具有比表面积高、孔隙率大、热稳定性好和结构与功能多样化的特点,因而被广泛用于气体存储、催化、吸附和分离等领域。MOFs复合材料在样品预处理方面的应用引起了研究者们的极大兴趣和广泛关注。由于MOFs材料和不同功能材料如高分子聚合物、碳基材料以及磁性材料组装复合,使MOFs复合材料的性能优于原来的MOFs材料。综述了近年MOFs复合材料在样品预处理的研究应用,尤其是在固相微萃取、固相萃取以及磁性固相萃取等方面的应用。  相似文献   

17.
刘洪媛  金静  郭崔崔  陈吉平  胡春 《色谱》2021,39(8):835-844
双酚类化合物作为一类内分泌干扰物广泛存在于环境介质中,经过多种途径迁移至人体后,可对人体产生内分泌毒性、细胞毒性、基因毒性、生殖毒性、二噁英毒性和神经毒性,已被加拿大政府风险评估识别为进一步优先控制名录。随着环境领域对双酚类化合物的广泛关注,相关研究工作逐渐向水、沉积物、灰尘和生物样品等多介质开拓。但是,由于不同环境样品在基质复杂性和污染物浓度水平等方面存在显著差异,开发提取效率高、净化选择性好、普适性强、操作简单、高通量的提取和净化方法,有助于实现环境介质中双酚类化合物的高灵敏、批量检测。近年来,新型前处理技术发展迅速,尤其是固相萃取技术,在双酚类化合物提取与净化方面取得了长足的发展,不仅在一定程度上克服了传统提取净化方法存在的耗时、耗力和耗溶剂等不足,而且为新型污染物分析提供了更多的技术支持。该文简述了典型双酚类化合物的理化性质、用途用量和环境危害,重点围绕新型固相萃取吸附剂开发和固相萃取模式转变两个方面,总结了固相萃取在双酚类化合物提取净化方法方面取得的进展。商品化固相萃取产品普适性强,在环境监测领域应用范围较广,适用于双酚类化合物的产品种类有限;新型吸附剂研发聚焦吸附容量(如介孔硅材料、碳纳米材料、金属-有机框架材料、环糊精)和选择性(如分子印迹聚合物和混合模式离子交换聚合物)两个方面,种类多样化可满足不同检测需求;越来越多的高灵敏分析仪器不断推向市场,为适应新的发展形势,固相萃取模式正逐渐向微型化、自动化、简易化等方向发展,如QuEChERS、固相微萃取、磁固相萃取等。  相似文献   

18.
A method has been developed for the quantitative extraction of nitrotoluenes (2,3-dinitrotoluene, 2,4-dinitrotoluene and trinitrotolugene) from water using a BakerbondTM phenyl sorbent. The average solid phase extraction recoveries for spiked standards ranged from 80 to 95 percent for reagent water and 52 to 95 percent from well and surface water in the low ppb and ppt levels. After the nitrotoluenes had been trapped on the solid sorbent they were quantitatively eluted using SFE. Adding toluene to the extraction cell increased the rate of extraction, but did not improve analyte recovery versus unmodified CO2. The extracts were analyzed off-line with GC–ECD using an internal standard. Extraction losses were due to analyte breakthrough, and not from poor SFE recoveries. This demonstrates that supercritical fluid extraction is a suitable elution technique for analytes trapped on solid phase extraction sorbents. Also, a method for the direct on-line coupling of SPE to GC, using SFE, has been developed and evaluated. Supercritical CO2 is ideal for directly coupling SPE to GC, since carbon dioxide is a gas under ambient conditions. One potential problem of on-line SPE–SFE–GC is the presence of residual water trapped on the active sites of the Bakerbond13 phenyl sorbent. This problem was dealt with by using a split interface previously described by Hawthorne. From the results of this study, the relative standard deviation of the on-line SPE–SFE–GC interface was determined to be between 4 and 10 percent. In addition, there was no significant difference in the precision of the method with or without the use of an internal standard. A calibration curve was also constructed (r2 = 0.995) from spiked controls, demonstrating that the method is quantitative.  相似文献   

19.
建立了地下水中1-氯萘、2-氯萘、1,4-二氯萘、1,2,3,4-四氯萘、1,3,5,7-四氯萘、1,2,3,5,7-五氯萘、1,2,3,5,6,7-六氯萘、1,2,3,4,5,6,7-七氯萘和八氯萘9种多氯萘(PCNs)的气相色谱-质谱(GC-MS)分析方法。对比研究了液液萃取(LLE)和固相萃取(SPE)萃取地下水中PCNs的提取效率,优选二氯甲烷-液液萃取为PCNs检测的前处理方法。在优化条件下,9种PCNs的线性范围为5~100μg/L,各组分的相关系数(r)大于0.995,方法检出限(S/N=3)为4.21~7.41 ng/L,地下水的平均加标回收率为70.7%~112%,相对标准偏差(RSD,n=5)均小于9.9%。该方法已用于地下水样中多氯萘的检测。  相似文献   

20.
半挥发性有机物主要包括多环芳烃类(PAHs)、邻苯二甲酸酯类(PAEs)、有机氯农药类(OCPs)和硝基苯类(NBs)等化合物,这些物质多具有致癌、致畸、致突变作用,以及内分泌干扰效应.因此,快速准确测定水中半挥发性有机物非常重要,目前国内尚无水中半挥发性有机物的检测标准.该研究从氮吹温度、水样pH值和萃取时间3个方面...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号