首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Speciation of arsenic in environmental samples gains increasingly importance, as the toxic effects of arsenic are related to its oxidation state. A method was developed for the determination of trace amounts of arsenic(III) and total arsenic by flow injection hydride generation coupled with an in-house made non-dispersive AAS device. The total arsenic is determined after prereduction of arsenic(V) to arsenic(III) with L-cysteine in a low concentration of hydrochloric, acetic or nitric acid. The conditions for the prereduction, hydride generation and atomization were systematically investigated. A quartz tube temperature of 800°C was found to be optimum in view of peak shape and baseline stability. Pb(II), Ni(II), Fe(III), Cu(II), Ag(I), Al(III), Ga(II), Se(IV), Bi(III) were checked for interfering with the 2g/L As(V) signal. A serious signal depression was only observed for Se(IV) and Bi(III) at a 150-fold excess. With the above system, arsenic was determined at a sampling frequency of about 1/min with a detection limit (3) of 0.01g/L using a 0.5mL sample. The reagent blank was 0.001±0.0003 absorbance units and the standard deviation of 10 measurements of the 2 g/l As signal was found to be 1.2%. Results obtained for standard reference materials and water samples are in good agreement with the certified values and those obtained by ICP-MS  相似文献   

2.
Arsenic(III) can be quantitatively extracted using sodium diethyldithiocarbamate (NaDDTC) as the complexing agent and C18 reversed phase packing as the column material for solid phase extraction. Arsenic(V) must be reduced to its trivalent oxidation state prior to extraction. A mixture of sodium sulphite, hydrochloric acid, sodium thiosulphate and potassium iodide was found to be optimum for on-line reduction. When the sorbent extraction is carried out without and with the addition of the reduction mixture, arsenic(III) and total arsenic can be determined sequentially by graphite furnace atomic absorption spectrometry with detection limits (3 σ) of 0.32 ng for As(III) and 0.43 ng for total arsenic. A 7.6-fold enhancement in peak area compared to direct injection of 40 μl samples was obtained after 60 s preconcentration. Results obtained for sea water standard reference materials, using aqueous standards for calibration, agree well with certified values. A precision of 5.5% RSD was obtained for total arsenic in a sea water sample (1.65 As). Results obtained for synthetic mixtures of trivalent and pentavalent arsenic agreed well with expected values.  相似文献   

3.
A simple procedure was developed for the direct determination of As(III) and As(V) in water samples by flow injection hydride generation atomic absorption spectrometry (FI–HG–AAS), without pre-reduction of As(V). The flow injection system was operated in the merging zones configuration, where sample and NaBH4 are simultaneously injected into two carrier streams, HCl and H2O, respectively. Sample and reagent injected volumes were of 250 μl and flow rate of 3.6 ml min−1 for hydrochloric acid and de-ionised water. The NaBH4 concentration was maintained at 0.1% (w/v), it would be possible to perform arsine selective generation from As(III) and on-line arsine generation with 3.0% (w/v) NaBH4 to obtain total arsenic concentration. As(V) was calculated as the difference between total As and As(III). Both procedures were tolerant to potential interference. So, interference such as Fe(III), Cu(II), Ni(II), Sb(III), Sn(II) and Se(IV) could, at an As(III) level of 0.1 mg l−1, be tolerated at a weight excess of 5000, 5000, 500, 100, 10 and 5 times, respectively. With the proposed procedure, detection limits of 0.3 ng ml−1 for As(III) and 0.5 ng ml−1 for As(V) were achieved. The relative standard deviations were of 2.3% for 0.1 mg l−1 As(III) and 2.0% for 0.1 mg l−1 As(V). A sampling rate of about 120 determinations per hour was achieved, requiring 30 ml of NaBH4 and waste generation in order of 450 ml. The method was shown to be satisfactory for determination of traces arsenic in water samples. The assay of a certified drinking water sample was 81.7±1.7 μg l−1 (certified value 80.0±0.5 μg l−1).  相似文献   

4.
M Sperling  X Yin  B Welz 《The Analyst》1992,117(3):629-635
A rapid, sensitive and selective method for the differential determination of CrIII and CrVI in natural waters is described. Chromium(vi) can be determined directly by flow injection on-line sorbent extraction preconcentration coupled with electrothermal atomic absorption spectrometry using sodium diethyldithiocarbamate as the complexing agent and C18 bonded silica reversed-phase sorbent as the column material. Total Cr can be determined after oxidation of CrIII to CrVI by potassium peroxydisulfate. Chromium(III) can be calculated by difference. The optimum conditions for sorbent extraction of CrVI and oxidation of CrIII to CrVI are evaluated. A 12-fold enhancement in sensitivity compared with direct introduction of 40 microliters samples was achieved after preconcentration for 60 s, giving detection limits of 16 ng l-1 for CrVI and 18 ng l-1 for total Cr (based on 3 sigma). Results obtained for sea-water and river water reference materials were all within the certified range for total Cr with a precision of better than 10% relative standard deviation in the range 100-200 ng l-1. The selectivity of the determination of CrVI was evaluated by analysing spiked reference materials in the presence of CrIII, resulting in quantitative recovery of CrVI.  相似文献   

5.
Summary Simultaneous Determination of Chromium(VI) and Chromium(III) by Flame Atomic Absorption Spectrometry with a Chelating Ion-Exchange Flow Injection System A simple method is described for the simultaneous determination of chromium(VI) and chromium(III) in a flow injection system comprising chelating ion-exchange and flame atomic absorption spectrometry. Sampling rates for 2001 and 1 ml sample volumes were 120 and 60 h–1 (240 and 120 speciations per hour), respectively. Typical relative standard deviations were 0.52% for Cr(VI) (0.50g ml–1 and 0.67% for Cr(III) (0.10,g ml–1) and the corresponding limits of detection were 85 ng ml–1, and 16 ng ml–1, respectively.On leave from University of Belgrade.  相似文献   

6.
A rapid and sensitive method has been proposed for the sequential determination of chromium(III) and total chromium in water samples by flame atomic absorption spectrometry combined with a flow injection on-line preconcentration on a double-microcolumn. The chromium(III) and total chromium in samples were retained on a double-microcolumn with a cation exchange resin, respectively, and eluted directly into a nebulizer by 3 mol L(-1) HNO3. The characteristic concentration (gives a derivative absorbance of 0.0044) and the detection limit (3sigma) for chromium were 0.512 microg L(-1) and 0.647 microg L(-1) for a preconcentration time of 1 min, respectively. This is an improvement of 20 and 14-times than those of conventional FI-FAAS. The proposed method allows the determination of chromium in the range of 0-90 microg L(-1) with a relative standard deviation of 3.63% at the 10 microg L(-1) level. The method has been applied for the analysis of chromium in reference water of National Research Center for Certified Reference Materials (GBW08607) and other water samples with satisfactory results.  相似文献   

7.
A hydride generation system using a small concentric hydride generator combined with inductively coupled plasma atomic emission spectrometry (ICP-AES) was established to determine tin, arsenic, bismuth and antimony in a marine sediment material with L-cysteine as a pre-reductant. Influences of concentrations of three kinds of acids (HCl, HNO3 and HClO4), L-cysteine, and sodium tetrahydroborate(III) as well as sodium hydroxide were investigated. The interferences from transition ions were found to be insignificant for determination of the four elements in presence of L-cysteine. Under optimized conditions the detection limits were 0.6 ng/mL for arsenic(III), 0.8 ng/mL for antimony(III), 1.7 ng/mL for tin(IV), and 1.2 ng/mL for bismuth(III). The method was applied to determine the four elements in standard marine sediment materials and the results were in agreement with certified values. Received: 4 September 1997 / Revised: 14 October 1997 / Accepted: 7 November 1997  相似文献   

8.
A hydride generation system using a small concentric hydride generator combined with inductively coupled plasma atomic emission spectrometry (ICP-AES) was established to determine tin, arsenic, bismuth and antimony in a marine sediment material with L-cysteine as a pre-reductant. Influences of concentrations of three kinds of acids (HCl, HNO3 and HClO4), L-cysteine, and sodium tetrahydroborate(III) as well as sodium hydroxide were investigated. The interferences from transition ions were found to be insignificant for determination of the four elements in presence of L-cysteine. Under optimized conditions the detection limits were 0.6 ng/mL for arsenic(III), 0.8 ng/mL for antimony(III), 1.7 ng/mL for tin(IV), and 1.2 ng/mL for bismuth(III). The method was applied to determine the four elements in standard marine sediment materials and the results were in agreement with certified values.  相似文献   

9.
The possible benefits of the addition of an anionic surfactant, didodecyldimethylammonium bromide, in the determination of arsenic, by flow injection hydride generation atomic absorption spectrometry using a flame-heated quartz tube atomizer, were studied in the light of previous reports concerning the effects of surfactants on chemical vapor generation procedures. Concentrations of arsenic between 5 and 30 μg l−1 were used. Calibrations in the presence and absence of the surfactant in the sample solution were not significantly different, either for the case where vesicles were formed in the presence of the analyte or where they were preformed in the surfactant solution and then added to the analyte. The surfactant had no effect on recoveries in the presence of copper, nickel or bismuth. The addition of the surfactant to the acid carrier and/or borohydride streams had no effect. It is proposed that there may be a greater role for surfactants in the improvement of the processes by which the hydride is transferred to the bulk gas phase than has been attributed in previous reports on this subject.  相似文献   

10.
A flow-injection system for the determination of inorganic arsenic [As(III)/As(V)] and selenium species [Se(IV)/ Se(VI)] by electrochemical hydride generation, cryogenic trapping and atomic absorption spectrometry is described. A simple and robust electrochemical flow-through cell with fibrous carbon as cathodic material has been developed for the speciation of arsenic. A cold-trap system makes possible to eliminate interferences from methylated arsenic species. Without pre-reduction the system is selective to As(III) and Se(IV). The selectivity obtained with fibrous carbon as cathode material is compared to the selectivity obtained with a second electrochemical flow-through cell using a lead foil as cathode.  相似文献   

11.
12.
A procedure is described for the sequential determination of arsenite and arsenate in samples of natural waters. It is based on the extraction of arsenic(III) with ammonium sec-butyl dithiophosphate and measurement, after re-extraction into water, by graphitefurnace atomic absorption spectrometry. Reduction of arsenic(V) allows its subsequent determination. The method is applied to fresh and sea water samples. The detection limit is 6 ngl-1.  相似文献   

13.
A novel chemiluminescence gas-diffusion flow injection system for the determination of arsenic(III) in aqueous samples is described. The analytical procedure involves injection of arsenic(III) samples and standards into a 0.3 mol L−1 hydrochloric acid carrier stream which is merged with a reagent stream containing 0.2% (w/v) sodium borohydride and 0.015 mol L−1 sodium hydroxide. Arsine, generated in the combined carrier/reagent donor stream, diffuses across the hydrophobic Teflon membrane of the gas-diffusion cell into an argon acceptor stream and then reacts with ozone in the flow-through chemiluminescence measuring cell of the flow system. Under optimal conditions, the method is characterized by a wide linear calibration range from 0.6 μg L−1 to 25 mg L−1, a detection limit of 0.6 μg L−1 and a sample throughput of 300 samples per hour at 25 mg L−1 and 450 samples per hour at 25 μg L−1.  相似文献   

14.
A simple and robust on-line sequential insertion system coupled with hydride generation atomic absorption spectrometry (HG-AAS) was developed, for selective As(III) and total inorganic arsenic determination without pre-reduction step. The proposed manifold, which is employing an integrated reaction chamber/gas-liquid separator (RC-GLS), is characterized by the ability of the successful managing of variable sample volumes (up to 25 ml), in order to achieve high sensitivity. Arsine is able to be selectively generated either from inorganic As(III) or from total arsenic, using different concentrations of HCl and NaBH4 solutions. For 8 ml sample volume consumption, the sampling frequency is 40 h−1. The detection limit is cL = 0.1 and 0.06 μg l−1 for As(III) and total arsenic, respectively. The precision (relative standard deviation) at 2.0 μg l−1 (n = 10) level is sr = 2.9 and 3.1% for As(III) and total arsenic, respectively. The performance of the proposed method was evaluated by analyzing the certified reference material NIST CRM 1643d and spiked water samples with various concentration ratios of As(III) to As(V). The method was applied for arsenic speciation in natural waters samples.  相似文献   

15.
Arsenic(III) can be extracted quantitatively from acidic media with ammonium pyrrolidinedithiocarbamate (APDC) and with diethyldithiophosphoric acid (HDEDTP). Arsenic-(V) can only be extracted after preliminary reduction to the trivalent state. Potassium iodide or a mixture of hydrogensulphite/thiosulphate is recommended. When the extraction is done once with and once without addition of reducing agent, the arsenic(III) and the arsenic(V) contents can be differentiated. Some bottled mineral waters were analyzed. All the arsenic present appears to be in the pentavalent state.  相似文献   

16.
A reversed flow injection colorimetric procedure for determining iron(III) at the μg level was proposed. It is based on the reaction between iron(III) with norfloxacin (NRF) in 0.07 mol l−1 ammonium sulfate solution, resulting in an intense yellow complex with a suitable absorption at 435 nm. Optimum conditions for determining iron(III) were investigated by univariate method. The method involved injection of a 150 μl of 0.04% w/v colorimetric reagent solution into a merged streams of sample and/or standard solution containing iron(III) and 0.07 mol l−1 ammonium sulfate in sulfuric acid (pH 3.5) solution which was then passed through a single bead string reactor. Subsequently the absorbance as peak height was monitored at 435 nm. Beer's law obeyed over the range of 0.2–1.4 μg ml−1 iron(III). The method has been applied to the determination of total iron in water samples digested with HNO3–H2O2 (1:9 v/v). Detection limit (3σ) was 0.01 μg ml−1 the sample through of 86 h−1 and the coefficient of variation of 1.77% (n=12) for 1 μg ml−1 Fe(III) were achieved with the recovery of the spiked Fe(III) of 92.6–99.8%.  相似文献   

17.
An automated method for the determination of arsenic acid (AsV), arsenous acid (AsIII), monomethylarsonic acid (MMAA) and dimethylarsinic acid (DMAA) was developed using a commercial available flow injection hydride generation system. By carrying out the hydride generation in selected acid media the determination of As(III) alone, of MMAA and DMAA by sum and by different sensitivities, and of all four species is possible.  相似文献   

18.
19.
A new approach for developing a cloud point extraction-electrothermal atomic absorption spectrometry has been described and used for determination of arsenic. The method is based on phase separation phenomenon of non-ionic surfactants in aqueous solutions. After reaction of As(V) with molybdate towards a yellow heteropoly acid complex in sulfuric acid medium and increasing the temperature to 55 °C, analytes are quantitatively extracted to the non-ionic surfactant-rich phase (Triton X-114) after centrifugation.To decrease the viscosity of the extract and to allow its pipetting by the autosampler, 100 μl methanol was added to the surfactant-rich phase. An amount of 20 μl of this solution plus 10 μl of 0.1% m/v Pd(NO3)2 were injected into the graphite tube and the analyte determined by electrothermal atomic absorption spectrometry.Total inorganic arsenic(III, V) was extracted similarly after oxidation of As(III) to As(V) with KMnO4. As(III) was calculated by difference. After optimization of the extraction condition and the instrumental parameters, a detection limit (3σB) of 0.01 μg l−1 with enrichment factor of 52.5 was achieved for only 10 ml of sample. The analytical curve was linear in the concentration range of 0.02-0.35 μg l−1. Relative standard deviations were lower than 5%. The method was successfully applied to the determination of As(III) and As(V) in tap water and total arsenic in biological samples (hair and nail).  相似文献   

20.
《Microchemical Journal》1986,34(2):190-195
An indirect atomic-absorption spectrometric method for the determination of aluminum carried out by flow injection analysis is proposed. This method is based on the enhancement of the atomic signal of iron, using a fuel-rich air-acetylene flame, by small amounts of aluminum, which allows the indirect determination of aluminum in the concentration range 0.2–1.8 μg ml−1 (r.s.d. 1.2%). The sampling frequency is 150 hr−1 for an injected volume of 54 μl. An extensive study of interferences has been compared, with considerable advantage, over the conventional method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号