首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
Non-invasive pulsed arterial spin labeling (PASL) MRI is a method to study brain perfusion that does not require the administration of a contrast agent, which makes it a valuable diagnostic tool as it reduces cost and side effects. The purpose of the present study was to establish the viability of PASL as an alternative to dynamic susceptibility contrast (DSC-MRI) and other perfusion imaging methods in characterizing changes in perfusion patterns caused by seizures in epileptic patients. We evaluated 19 patients with PASL. Of these, the 9 affected by high-frequency seizures were observed during the peri-ictal period (within 5 hours since the last seizure), while the 10 patients affected by low-frequency seizures were observed in the post-ictal period. For comparison, 17/19 patients were also evaluated with DSC-MRI and CBF/CBV. PASL imaging showed focal vascular changes, which allowed the classification of patients in three categories: 8 patients characterized by increased perfusion, 4 patients with normal perfusion and 7 patients with decreased perfusion. PASL perfusion imaging findings were comparable to those obtained by DSC-MRI. Since PASL is a) sensitive to vascular alterations induced by epileptic seizures, b) comparable to DSC-MRI for detecting perfusion asymmetries, c) potentially capable of detecting time-related perfusion changes, it can be recommended for repeated evaluations, to identify the epileptic focus, and in follow-up and/or therapy-response assessment.  相似文献   

2.
Quantitative cerebral blood flow (CBF) values can be determined from residue function estimates obtained from magnetic resonance dynamic susceptibility contrast (DSC) perfusion studies using a variety of deconvolution approaches. However, there are significant differences between the CBF estimates obtained, differences that are not simply due to minor details of the implementation of the algorithms. The standard singular value decomposition (sSVD) shows a variation of CBF values with arterial-tissue delay (ATD) not present with the Fourier transform deconvolution algorithm. Fourier transform deconvolution and the newly suggested delay-invariant SVD algorithm implementations provide CBF estimates whose accuracy changes with tissue mean transit times (MTTs). Techniques combining sSVD with deliberate ATD manipulation have been proposed to compensate for this inaccuracy. Other studies indicate that CBF changes related to slice position in a multislice study, and other experimental factors, can be reduced using interpolative deconvolution algorithms. In this review, we use both time-domain and frequency-domain analysis to show the underlying theoretical relationships between these many approaches to obtain "the best" CBF estimate. This model allows us to better understand the similarities and differences, advantages and disadvantages between these variants of the deconvolution algorithms used in DSC perfusion studies.  相似文献   

3.
准连续性动脉自旋标记技术(pCASL)是一种新兴的动脉自旋标记脑灌注成像技术(ASL):一方面,它克服了连续性动脉自旋标记技术(CASL)需要独立发射线圈的硬件限制;另一方面,也避免了脉冲式动脉自旋标记技术(PASL)带来的标记效率低的影响.为了在 1.5 T 磁共振系统上开发一款可稳定应用于临床扫描的 pCASL 序列;并使用该序列准确获得反
应灌注功能的局部脑血流量值(Regional Cerebral Blood Flow, rCBF).该文利用水模测试pCASL 序列,验证了标记部分的标记性能并通过人体实验,优化了协议中标记位置中心到成像层面中心的距离和标记部分结束点到成像脉冲开始前的等待时间这两项参数.基于优化了参数的 pCASL 协议,扫描 12 组正常志愿者,观测灌注信号分布情况,并对特定灰质区域定量计算,对比不同个体该区域的 rCBF 值.通过人体实验,经验性地确定了延迟时间为 1 200 ms、标记距离为 70 mm 时灌注图像的信噪比达到最优.将两项优化后的参数存入协议中,并使用协议扫描,共获取 12 组结果,其中的 10 组都表明灌注信号稳定均匀,并且灰质区域的 CBF 值同经验结果一致.该工作在1.5 T 的磁共振系统上成功实现了 pCASL序列,经优化参数后的协议扫描,可以获得准确稳定的脑部灌注信号.
  相似文献   

4.
Pulsed arterial spin labeling (PASL) is an increasingly common technique for noninvasively measuring cerebral blood flow (CBF) and has previously been shown to have good repeatability. It is likely to find a place in clinical trials and in particular the investigation of pharmaceutical agents active in the central nervous system. We aimed to estimate the sample sizes necessary to detect regional changes in CBF in common types of clinical trial design including (a) between groups, (b) a two-period crossover and (3) within-session single dosing. Whole brain CBF data were acquired at 3 T in two independent groups of healthy volunteers at rest; one of the groups underwent a repeat scan. Using these data, we were able to estimate between-groups, between-session and within-session variability along with regional mean estimates of CBF. We assessed the number of PASL tag-control image pairs that was needed to provide stable regional estimates of CBF and variability of regional CBF across groups. Forty tag-control image pairs, which take approximately 3 min to acquire using a single inversion label delay time, were adequate for providing stable CBF estimates at the group level. Power calculations based on the variance estimates of regional CBF measurements suggest that comparatively small cohorts are adequate. For example, detecting a 15% change in CBF, depending on the region of interest, requires from 7-15 subjects per group in a crossover design, 6-10 subjects in a within-session design and 20-41 subjects in a between-groups design. Such sample sizes make feasible the use of such CBF measurements in clinical trials of drugs.  相似文献   

5.
This study deals with perfusion quantification in healthy volunteers using two types of dynamic magnetic resonance imaging (MRI) methods. Absolute cerebral blood flow (CBF) measurements were performed in 11 subjects by applying both bolus tracking of exogenous contrast agent and non-invasive arterial spin labeling MRI techniques. Both methods produced CBF images with good tissue contrast and CBF values are in good agreement with literature data. The correlation between cerebral blood volume (CBV) and CBF is also discussed.  相似文献   

6.
Multislice Q2TIPS is a widely used pulsed arterial spin labeling (PASL) technique for efficient and accurate quantification of cerebral blood flow (CBF). Slices are typically acquired inferior to superior from a tagging plane. Superior slices show signal loss greater than the loss expected from blood T1 decay. In order to assess the reasons for this additional signal loss, three single-slice acquisition studies were compared to multislice acquisition (six slices) in healthy volunteers. In Study 1 (n=8), the tagging plane was fixed in location, and the inversion time (TI2) was 1500 ms for each slice. For Study 2 (n=12), the tagging plane was fixed as in Study 1; however, TI2 increased as slices were acquired further from the tagging plane. In Study 3 (n=9), the tagging plane was kept adjacent to the imaging slice, and TI2 was 1500 ms for every slice. Gray matter (GM) and white matter (WM) signal-to-noise ratio (SNR) and CBF were measured per slice. GM SNR from single-slice acquisitions was significantly higher at slices 4-6 in Study 2 and at slices 2-6 in Study 3 compared to multislice acquisitions. Signal loss in distal slices of multislice acquisitions can be attributed to the destruction of tagged bolus in addition to blood T1 decay. If limited brain coverage is acceptable, perfusion images with greater SNR are achievable with limited slices and placement of the tagging region immediately adjacent to the site of interest.  相似文献   

7.
Magnetic resonance (MR) perfusion imaging is a clinical technique for measuring brain blood flow parameters during stroke and other ischemic events. Ischemia in brain tissue can be difficult to accurately measure or visualize when using MR-derived cerebral blood flow (CBF) maps. The deconvolution techniques used to estimate flow can introduce a mean transit time-dependent bias following application of noise stabilization techniques. The underestimation of the CBF values, greatest in normal tissues, causes a decrease in the image contrast observed in CBF maps between normally perfused and ischemic tissues; resulting in ischemic areas becoming less conspicuous. Through application of the proposed simple extrapolation technique, CBF biases are reduced when missing high-frequency signal components in the MR data removed during deconvolution noise stabilization are restored. The extrapolation approach was compared with other methods and showed a statistically significant increase in image contrast in CBF maps between normal and ischemic tissues for white matter (P<.05) and performed better than most other methods for gray matter. Receiver operator characteristic curve analysis demonstrated that extrapolated CBF maps better-detected penumbral regions. Extrapolated CBF maps provided more accurate CBF estimates in simulations, suggesting that the approach may provide a better prediction of outcome in the absence of treatment.  相似文献   

8.
Noninvasive absolute quantification of cerebral blood flow (CBF) with high spatial resolution is still a challenging task. Arterial spin labeling (ASL) is a promising magnetic resonance imaging (MRI) method for accurate perfusion quantification. However, modeling of ASL data is far from being standardized and has not been investigated in great detail. In this study, two-compartment modeling of monkey ASL data in three physiological conditions (baseline, sensory activated and globally elevated CBF) is reported. Absolute perfusion and arterial transit times were derived for gray matter (GM) and white matter (WM) separately. The uncertainties of the model's result were determined by Monte Carlo simulations. The fitted CBF values for GM were 133 ml/min/100 ml at baseline condition, 165 ml/min/100 ml during visual stimulation and 234 ml/min/100 ml for globally elevated CBF after intravenous injection of acetazolamide. The ratio of GM to WM CBF was 2.5 at baseline and was found to decrease to 1.6 after application of acetazolamide. The corresponding arterial transit times decreased from 742 to 607 ms in GM and from 985 to 875 ms in WM. Monte Carlo simulations showed that absolute CBF values can be determined with an error of 11-15%, while the arterial transit time values have a coefficient of variation of 25-31%. With an alternative acquisition scheme, the precision of the arterial transit times can be improved significantly. The CBF values in the occipital lobe of the monkey brain quantified with ASL are higher than previously reported in positron emission tomography studies.  相似文献   

9.

Introduction

The bolus-tracking (BT) technique is the most popular perfusion-weighted (PW) dynamic susceptibility contrast MRI method used for estimating cerebral blood flow (CBF), cerebral blood volume and mean transit time. The BT technique uses a convolution model that establishes the input–output relationship between blood flow and the vascular tracer concentration. Singular value decomposition (SVD)- and Fourier transform (FT)-based deconvolution methods are popular and widely used for estimating PW MRI parameters. However, from the published literature, it appears that SVD is more widely accepted than other methods. In a previous article, an FT-based minimum mean-squared error (MMSE) technique was proposed and simulation experiments were performed to compare it with the well-established circular SVD (oSVD) method. In this study, the FT-based MMSE method has been used to estimate relative CBF (rCBF) in 13 patients with white matter lesions (WMLs) (leukoaraiosis), and results are compared with the widely used oSVD method.

Materials and Methods

Thirteen patients with leukoaraiosis were imaged on a 1.5-T Siemens whole-body scanner. After acquiring the localizer and structural scans consisting of FLAIR (fluid attenuated with inversion recovery), T1-weighted and T2-weighted images, perfusion study was implemented as part of the MRI protocol. For each patient and method, two values were calculated: (a) rCBF for normal white matter (NWM) ROI, obtained by dividing the average CBF value in NWM ROI with average CBF in gray matter (GM) ROI, and (b) rCBF for WML ROI, obtained by dividing the average CBF value in WML ROI with average CBF in GM ROI. Results for the two deconvolution methods were computed.

Results and Discussion

A significant (P<.05) decrease in estimated rCBF was observed in the WML in all the patients using the MMSE method, while for the oSVD method, the decrease was observed in all but one patient. Initial results suggest that the MMSE method is comparable to the oSVD method for estimating rCBF in NMW while it may be better than oSVD for estimating rCBF in lesions of low flow. Studies involving a larger patient population may be required to further validate the findings of this work.  相似文献   

10.
In this study we present a novel automated strategy for predicting infarct evolution, based on MR diffusion and perfusion images acquired in the acute stage of stroke. The validity of this methodology was tested on novel patient data including data acquired from an independent stroke clinic. Regions-of-interest (ROIs) defining the initial diffusion lesion and tissue with abnormal hemodynamic function as defined by the mean transit time (MTT) abnormality were automatically extracted from DWI/PI maps. Quantitative measures of cerebral blood flow (CBF) and volume (CBV) along with ratio measures defined relative to the contralateral hemisphere (r(a)CBF and r(a)CBV) were calculated for the MTT ROIs. A parametric normal classifier algorithm incorporating these measures was used to predict infarct growth. The mean r(a)CBF and r(a)CBV values for eventually infarcted MTT tissue were 0.70 +/- 0.19 and 1.20 +/- 0.36. For recovered tissue the mean values were 0.99 +/- 0.25 and 1.87 +/- 0.71, respectively. There was a significant difference between these two regions for both measures (p < 0.003 and p < 0.001, respectively). Mean absolute measures of CBF (ml/100g/min) and CBV (ml/100g) for the total infarcted territory were 33.9 +/- 9.7 and 4.2 +/- 1.9. For recovered MTT tissue, the mean values were 41.5 +/- 7.2 and 5.3 +/- 1.2, respectively. A significant difference was also found for these regions (p < 0.009 and p < 0.036, respectively). The mean measures of sensitivity, specificity, positive and negative predictive values for modeling infarct evolution for the validation patient data were 0.72 +/- 0.05, 0.97 +/- 0.02, 0.68 +/- 0.07 and 0.97 +/- 0.02. We propose that this automated strategy may allow possible guided therapeutic intervention to stroke patients and evaluation of efficacy of novel stroke compounds in clinical drug trials.  相似文献   

11.
The saturation-recovery (SR)-T1 MRI method for quantitatively imaging cerebral blood flow (CBF) change (ΔCBF) concurrently with the blood oxygenation level dependence (BOLD) alteration has been recently developed and validated by simultaneous measurement of relative CBF change using laser Doppler flowmetry (LDF) in rats at 9.4T. In this study, ΔCBF induced by mildly transient hypercapnia and measured by the SR-T1 MRI method was rigorously compared with an established perfusion MRI method—continuous arterial spin labeling (CASL) approach in normal and preclinical middle cerebral artery occlusion (MCAo) rat models. The results show an excellent agreement between ΔCBF values measured with these two imaging methods. Moreover, the intrinsic longitudinal relaxation rate (R1int) was experimentally determined in vivo in normal rat brains at 9.4T by comparing two independent measures of the apparent longitudinal relaxation rate (R1app) and CBF measured by the CSAL approach across a wide range of perfusion. In turn, the R1int constant can be employed to calculate the CBF value based on the R1app measurement in healthy brain. This comparison study validates the fundamental relationship for linking brain tissue water R1app and cerebral perfusion, demonstrates the feasibility of imaging and quantifying both CBF and its change using the SR-T1 MRI method in vivo.  相似文献   

12.
Abnormalities in cerebral blood flow (CBF) are believed to play a significant role in the development of major neonatal neuropathologies. One approach that would appear ideal for measuring CBF in this fragile age group is arterial spin labeling (ASL) since ASL techniques are noninvasive and quantitative. The purpose of this study was to assess the accuracy of a pulsed ASL method implemented on a 3-T scanner dedicated to neonatal imaging. Cerebral blood flow was measured in nine neonatal piglets, the ASL–CBF measurements were acquired at two inversion times (TI) (1200 and 1700 ms), and CBF was measured by perfusion computed tomography (pCT) for validation. Perfusion CT also provided images of cerebral blood volume, which were used to identify large blood vessels, and contrast arrival time, which were used to assess differences in arterial transit times between gray and white matter. Good agreement was found between gray matter CBF values from pCT (76±1 ml/min per 100 g) and ASL at TI=1700 ms (73±1 ml/min per 100 g). At TI=1200 ms, ASL overestimated CBF (91±2 ml/min per 100 g), which was attributed to substantial intravascular signal. No significant differences in white matter CBF from pCT and ASL were observed (average CBF=60±1 ml/min per 100 g), nor was there any difference in contrast arrival times for gray and white matter (0.95±0.04 and 0.99±0.03 s, respectively), which suggests that the arterial transit times for ASL were the same in this animal model. This study verified the accuracy of the implemented ASL technique and showed the value of using pCT to study other factors that can affect ASL–CBF measurements.  相似文献   

13.
Arterial spin labeling (ASL) using magnetic resonance imaging (MRI) is a powerful noninvasive technique to investigate the physiological status of brain tissue by measuring cerebral blood flow (CBF). ASL assesses the inflow of magnetically labeled arterial blood into an imaging voxel. In the last 2 decades, various ASL sequences have been proposed which differ in their ease of implementation and their sensitivity to artifacts. In addition, several quantification methods have been developed to determine the absolute value of CBF from ASL magnetization difference images. In this study, we evaluated three pulsed ASL sequences and three absolute quantification schemes. It was found that FAIR-QUIPSSII implementation of ASL yields 10–20% higher signal-to-noise ratio (SNR) and 18% higher CBF as compared with PICORE-Q2TIPS (with FOCI pulses) and PICORE-QUIPSSII (with BASSI pulses). In addition, quantification schemes employed can give rise to up to a 35% difference in CBF values. We conclude that, although all quantitative ASL sequences and CBF calibration methods should in principle result in the similar CBF values and image quality, substantial differences in CBF values and SNR were found. Thus, comparing studies using different ASL sequences and analysis algorithms is likely to result in erroneous intra- and intergroup differences. Therefore, (i) the same quantification schemes should consistently be used, and (ii) quantification using local tissue proton density should yield the most accurate CBF values because, although still requiring definitive demonstration in future studies, the proton density of blood is assumed to be very similar to the value of gray matter.  相似文献   

14.
Denoising is critical to improving the quality and stability of cerebral blood flow (CBF) quantification in arterial spin labeled (ASL) perfusion magnetic resonance imaging (MRI) due to the intrinsic low signal-to-noise-ratio (SNR) of ASL data. Previous studies have been focused on reducing the spatial or temporal noise using standard filtering techniques, and less attention has been paid to two global nuisance effects, the residual motion artifacts and the global signal fluctuations. Since both nuisances affect the whole brain, removing them in advance should enhance the CBF quantification quality for ASL MRI. The purpose of this paper was to assess this potential benefit. Three methods were proposed to suppress each or both of the two global nuisances. Their performances for CBF quantification were validated using ASL data acquired from 13 subjects. Evaluation results showed that covarying out both global nuisances significantly improved temporal SNR and test-retest stability of CBF measurement. Although the concept of removing both nuisances is not technically novel per se, this paper clearly showed the benefits for ASL CBF quantification. Dissemination of the proposed methods in a free ASL data processing toolbox should be of interest to a broad range of ASL users.  相似文献   

15.
Quantitative, multislice dynamic susceptibility contrast-enhanced MRI perfusion measurements were used to determine the patterns of cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), and normalized first moment of the tissue deltaR2-time curve (N) in 11 subjects with carotid artery occlusion or stenosis. MTT correlated with degree of carotid stenosis, whereas a range of alterations in CBF and CBV were found presumably reflecting variables degrees of collateral flow. There was no significant correlation between MRI and SPET flow perfusion measurements, with increasing disparity between the two techniques at higher inter-hemispheric flow ratios. The effect of obtaining the arterial input function (AIF) from the middle cerebral artery (MCA) ipsilateral or contralateral to the stenosis was determined. Despite the use of an AIF from the MCA, which is distal to the circle of Willis, and hence the major sources of collateral supply, there was still some extra dispersion of the contrast agent bolus due to differences in arrival time.  相似文献   

16.
Arterial spin labeling (ASL) magnetic resonance imaging (MRI) is becoming a popular method for measuring perfusion due to its ability of generating perfusion maps noninvasively. This allows for frequent repeat scanning, which is especially useful for follow-up studies. However, limited information is available regarding the reliability and reproducibility of ASL perfusion measurements. Here, the reliability and reproducibility of pulsed ASL was investigated in an elderly population to determine the variation in perfusion among cognitively normal individuals in different brain structures. Intraclass correlation coefficients (ICC) and within-subject variation coefficients (wsCV) were used to estimate reliability and reproducibility over a period of 1 year. Twelve cognitively normal subjects (75.5±5.3 years old, six male and six female) were scanned four times (at 0, 3, 6 and 12 months). No significant difference in cerebral blood flow (CBF) was found over this period. CBF values ranged from 46 to 53 ml/100 g per minute in the medial frontal gyrus (MFG) and from 40 to 44 ml/100 g per minute over all gray matter regions in the superior part of the brain. Data obtained from the first two scans were processed by two readers and showed high reliability (ICC >0.97) and reproducibility (wsCV <6%). However, over the total period of 1 year, reliability reduced to a moderate level (ICC=0.63–0.74) with wsCVs of gray matter, left MFG, right MFG of 13.5%, 12.3%, and 15.4%, respectively. In conclusion, measurement of CBF with pulsed ASL provided good agreement between inter-raters. A moderate level of reliability was obtained over a 1-year period, which was attributed to variance in slice positioning and coregistration. As such pulsed ASL has the potential to be used for CBF comparison in longitudinal studies.  相似文献   

17.
Pharmacological MRI (phMRI) methods have been widely applied to assess the central hemodynamic response to pharmacological intervention as a surrogate for changes in the underlying neuronal activity. However, many psychoactive drugs can also affect cardiovascular parameters, including arterial blood pressure (BP). Abrupt changes in BP or the anesthetic agents used in preclinical phMRI may impair cerebral blood flow (CBF) autoregulation mechanisms, potentially introducing confounds in the phMRI response. Moreover, relative cerebral blood volume (rCBV), often measured in small-animal phMRI studies, may be sensitive to BP changes even in the presence of intact autoregulation. We applied laser Doppler flowmetry and MRI to measure changes in CBF and microvascular CBV induced by increasing doses of intravenous norepinephrine (NE) challenge in the halothane-anesthetized rat. NE is a potent vasopressor that does not cross the blood-brain barrier and mimics the rapid BP changes typically observed with acute drug challenges. We found that CBF autoregulation was maintained over a BP range of 60-120 mmHg. Under these conditions, no significant central rCBV responses were observed, suggesting that microvascular rCBV changes in response to abrupt changes in perfusion pressure are negligible within the autoregulatory range. Larger BP responses were accompanied by significant changes in both CBV and CBF that might confound the interpretation of phMRI results.  相似文献   

18.
The cerebral blood flow (CBF) is an important vital parameter in neurointensive care. Currently, there is no non-invasive method for its measurement that can easily be applied at the bedside. A new tool to determine CBF is based on near-infrared spectroscopy (NIRS) applied together with indocyanine green (ICG) dye dilution. From a bilateral measurement on selected regions on the head of infrared (IR) absorption at various wavelengths during the dilution maneuver, the vascular perfusion characteristics of the two brain hemispheres can be determined in terms of mean transit time (mtt) of ICG, cerebral blood volume (CBV) and CBF. So far, on nine healthy volunteers, NIRS ICG dye dilution bihemispheric measurements were performed, which yielded to mtt given as median (range) of 9.3 s (5.1–16.3 s), CBV of 3.5 ml/100 g (1.7–4.1 ml/100 g), and CBF of 18.2 ml/(100 g×min) [11.1–48.6 ml/(100 g×min)]. Additionally, the blood flow index (BFI) was calculated with BFI= 13.8 mg/(100 g×s) [6.6–15.2 mg/(100 g×s)]. The Spearman rank correlation coefficient between CBF and BFI was RS = 0.76. However, as the Bland & Altman plot between CBFNIRS and the CBFBFI documents, the limits of agreement are rather wide (21.9±6.7). Under physiological conditions in healthy volunteers, no differences could be detected between the hemispheres.  相似文献   

19.

Purpose

To evaluate whether a non-linear blood ΔR2*-versus-concentration relationship improves quantitative cerebral blood flow (CBF) estimates obtained by dynamic susceptibility contrast (DSC) MRI in a comparison with Xe-133 SPECT CBF in healthy volunteers.

Material and Methods

Linear as well as non-linear relationships between ΔR2* and contrast agent concentration in blood were applied to the arterial input function (AIF) and the venous output function (VOF) from DSC-MRI. To reduce partial volume effects in the AIF, the arterial time integral was rescaled using a corrected VOF scheme.

Results

Under the assumption of proportionality between the two modalities, the relationship CBF(MRI) = 0.58CBF(SPECT) (r = 0.64) was observed using the linear relationship and CBF(MRI) = 0.51CBF(SPECT) (r = 0.71) using the non-linear relationship.

Discussion

A smaller ratio of the VOF time integral to the AIF time integral and a somewhat better correlation between global DSC-MRI and Xe-133 SPECT CBF estimates were observed using the non-linear relationship. The results did not, however, confirm the superiority of one model over the other, potentially because realistic AIF signal data may well originate from a combination of blood and surrounding tissue.  相似文献   

20.
PurposeTo investigate the feasibility for preoperative prediction of IDH mutation and MGMT promoter methylation status in glioblastomas(GBMs) by intravoxel incoherent motion(IVIM) and dynamic susceptibility contrast(DSC).MethodsPreoperative IVIM and DSC images of 71 patients(IDH mutation:45, IDH wildtype: 26; MGMT methylation: 31, MGMT unmethylation:40) with glioblastomas were analyzed retrospectively. Perfusion parameters including microcirculation perfusion coefficient(D*), perfusion fraction(f), cerebral blood volume(CBV) and cerebral blood flow(CBF) were measured. Corrected perfusion parameters containing corrected perfusion coefficient(ADCperf) and simplified perfusion fraction(SPF) were from the simplified IVIM with 3 b values. Correlations among parameters were analyzed by Spearman correlation. All parameters were compared with Mann-Whitney U test. Univariate and multivariate logistic regression models were constructed. The receiver operating characteristic(ROC) curve was analyzed.ResultsThe IVIM parameters showed merely moderate correlations with CBV and showed no correlation with CBF. IDH mutation GBMs showed lower D*, ADCperf, SPF, CBV and higher f than IDH wildtype GBMs(all p < 0.05). D* was the independent predictor for IDH mutation with the highest AUC of 0.912(95%CI: 0.821–0.966). The D*, ADCperf, SPF and CBV of MGMT promoter methylation GBMs were lower than unmethylation GBMs while f was higher(all p < 0.05). Multivariate model showed the highest prediction efficacy for MGMT promoter methylation with an AUC of 0.915(95%CI: 0.824–0.968). The CBF was not useful in distinguishing IDH mutation and MGMT promoter methylation status(p = 0.055, 0.215).ConclusionIDH mutation and MGMT promoter methylation status in GBMs can be assessed effectively by IVIM and DSC. Besides, D* was the independent predictor of IDH mutation status.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号