首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Implementation and optimization of an off-line capillary electrophoresis (CE)/(−)nanoESIchip-quadrupole time-of-flight (QTOF) mass spectrometric (MS) and tandem MS system for compositional mapping and structural investigation of components in complex carbohydrate mixtures is described. The approach was developed for glycoscreening and applied to O-glycosylated peptides from urine of a patient suffering from α-N-acetylhexosaminidase deficiency, known as Schindler's disease. The fundamental issue of sensitivity, previously representing a serious drawback of the off-line CE/MS analysis, could be positively addressed by the off-line conjunction of CE with automated chip-based ESI-QTOF-MS to provide flexibility for CE/chip MS coupling and enhance structural elucidation of single components in heterogeneous mixtures. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

2.
A thin polymer microchip was coupled with a Fourier transform ion cyclotron resonance (FTICR) 9.4 T mass spectrometer and the method was optimized in negative ion mode for glycopeptide screening. The interface between the polymer microchip and FTICR mass spectrometer consists of an in-laboratory conceived and designed mounting system that exhibits robust and controllable alignment of the chip toward the inlet of the mass spectrometer. The particular attribute of the polymer chip coupled to the FTICR mass spectrometer, to achieve an increase in ionization efficiency and sensitivity under the premise of high mass accuracy of detection, is highlighted by the large number of major and minor glycopeptide structures detected and identified in highly heterogeneous mixtures obtained from urine matrices. Glycoforms expressing various saccharide chain lengths ranging from tri- to dodecasaccharide, bearing up to three sialic acid moieties, could be detected and assigned based on the accuracy of the mass measurement (average mass deviation below 6 ppm) of their molecular ions. -Thin chipESI-FTICRMS is a potent novel system for glycomic screening of complex mixtures, as demonstrated for identification of singly sialylated O-glycosylated amino acids and peptides from urine matrices, and could be considered for general applicability in the glycoanalytical field.  相似文献   

3.
Zhao C  Wu Z  Xue G  Wang J  Zhao Y  Xu Z  Lin D  Herbert G  Chang Y  Cai K  Xu G 《Journal of chromatography. A》2011,1218(23):3669-3674
Nanoflow liquid chromatography/mass spectrometry (nano-LC/MS) has attracted increasing interest in virtue of high sensitivity, low sample consumption, and minimal matrix effect. In this work a HPLC-Chip/quadrupole time-of-flight (Q-TOF) MS device with a new ultra-high capacity small molecule chip (UHC-Chip) which features a 500 nL enrichment column and a 150 mm × 75 μm analytical column, was evaluated with a drug mixture covering a wide range of polarities. Excellent chromatographic precision with 0.1-0.5% RSD for retention time and 1.7-9.0% RSD for peak area, low limit of detection, good chip-to-chip reproducibility and linearity were obtained by using this UHC-Chip. Compared with the standard HPLC-Chip with 40 nL trapping column, the UHC-Chip showed higher enrichment capability and hence gave a higher response in signal detection. Additionally, 4-30 times increase in sensitivity was obtained compared with conventional LC/MS, which indicated that UHC-Chip/MS was a valuable tool for the quantitative analysis of low level impurities and degradation products in pharmaceuticals. Moreover, satisfactory results obtained from trace drug analysis of serum samples further proved its practicality and potential for use in drug testing and development.  相似文献   

4.
High-throughput screening (HTS) is a technique mostly used by pharmaceutical companies to rapidly screen multiple libraries of compounds to find drug hits with biological or pharmaceutical activity. Mass spectrometry (MS) has become a popular option for HTS given that it can simultaneously resolve hundreds to thousands of compounds without additional chemical derivatization. For this application, it is convenient to do direct analysis from well plates. Herein, we present the development of an infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) source coupled directly to an Agilent 6545 for direct analysis from well plates. The source is coupled to a quadrupole time-of-flight (Q-TOF) mass spectrometer to take advantage of the high acquisition rates without sacrificing resolving power as required with Orbitrap or Fourier-transform ion cyclotron resonance (FTICR) instruments. The laser used for this source operates at 100 Hz, firing 1 pulse-per-burst, and delivers around 0.7 mJ per pulse. Continuously firing this laser for an extended duration makes it a quasi-continuous ionization source. Additionally, a metal capillary was constructed to extend the inlet of the mass spectrometer, increase desolvation of electrospray charged droplets, improve ion transmission, and increase sensitivity. Its efficiency was compared with the conventional dielectric glass capillary by measured signal and demonstrated that the metal capillary increased ionization efficiency due to its more uniformly distributed temperature gradient. Finally, we present the functionality of the source by analyzing tune mix directly from well plates. This source is a proof of concept for HTS applications using IR-MALDESI coupled to a different MS platform.  相似文献   

5.
The use of fast and reliable analytical procedures for olive oil authentication is a priority demand due to its wide consumption and healthy benefits. Olive oil adulteration with other cheaper vegetable oils is a common practice that has to be detected and controlled. Rapid screening methods based on high resolution tandem mass spectrometry constitute today the option of choice due to sample handling simplicity and the elimination of the chromatographic step. The selection of the ionization source is critical and the comparison of their reliability necessary. The possibilities of the direct infusion electrospray ionization (ESI) and the recently introduced atmospheric pressure photospray ionization source (APPI), coupled to quadrupole time-of-flight (QqTOF), have been critically studied and compared to control olive oil adulteration. These techniques are very rapid (approximately 1 min per sample) and have high discrimination power to elucidate key components in the edible oils studied (olive, hazelnut, sunflower and corn). Nevertheless, both sources are complementary, being APPI more sensitive for monoacyl- and diacylglycerol fragment ions and ESI for triacylglycerols. In addition, methods reproducibility's are very high, especially for APPI source. Mixtures of olive oil with the others vegetable oils can be easily discriminated which has been tested by using principal components analysis (PCA) with both ESI-MS and APPI-MS spectra. Analogously, linear discriminant analysis (LDA) confirms methods reproducibility and detection of other oils used as adulterants, in particular hazelnut oil, which is especially difficult given its chemical similarity with olive oil.  相似文献   

6.
Zheng Y  Li H  Guo Z  Lin JM  Cai Z 《Electrophoresis》2007,28(9):1305-1311
A novel approach using sheath flow chip-based CE coupled to a quadrupole TOF mass spectrometer was developed and applied to the analysis of an O-glycopeptide. The method provided good separation and sensitive analysis of the glycopeptide and its beta-elimination product. The beta-elimination reaction of the glycopeptide with ammonia or dimethylamine was adapted for changing the glycopeptide into deglycosylated form and for specifying the site of glycosylation. MS/MS analysis of the native peptide, glycopeptide and beta-elimination product enabled the identification of the glycosylation site through the comparison of the fragmentations and peptide sequence analysis.  相似文献   

7.
A novel method for separating ions according to their charge state using a quadrupole time-of-flight mass spectrometer is presented. The benefits of charge state separation are particularly apparent in protein identification applications at low femtomole concentration levels, where in conventional TOF MS spectra peptide ions are often lost in a sea of chemical noise. When doubly and triply charged tryptic peptide ions need to be filtered from singly charged background ions, the latter are suppressed by two to three orders of magnitude, while from 10-50% of multiply charged ions remain. The suppression of chemical noise reduces the need for chromatography and can make this experimental approach the electrospray equivalent of conventional MALDI peptide maps. If unambiguous identification cannot be achieved, MS/MS experiments are performed on the precursor ions identified through charge separation, while the previously described Q2-trapping duty cycle enhancement is tuned for approximately 1.4 of the precursor m/z to enhance intensities of ions with m/z values above that of the precursor. The resulting product ion spectra contain few fragments of impurities and provide quick and unambiguous identification through database search. The multiple charge separation technique requires minimal tuning and may become a useful tool for analysis of complex mixtures.  相似文献   

8.
A liquid chromatographic mass spectrometric strategy for systematic toxicological analysis (STA) is presented using the automatic 'on-the-fly' single mass spectrometry mode to tandem mass spectrometry mode (MS to MS/MS) switching abilities of a quadrupole time-of-flight (Q-TOF) instrument. During the chromatographic run, the quadrupole is initially set to transmit all masses until (an) ion(s) reaches a certain set threshold. Thereupon, the quadrupole automatically switches to the MS/MS mode, selecting the ion(s), which are subsequently fragmented in the high-efficiency hexapole collision cell, thus generating product ions that are further mass analyzed by the TOF. By limiting the TOF spectral accumulation time in the MS/MS mode to a statistically acceptable minimum, the quadrupole almost instantly switches back to the MS mode. Qualitative information, comprising the complementary MS ([M + H](+) ion mass) and MS/MS (informative product ion profile) data, as well as quantitative information obtained by integration of the MS extracted ion chromatogram(s), can be obtained in one single acquisition. Optimization of the automatic switching parameters, such as threshold, TOF spectral accumulation time, detection window and collision energy, was carried out by injection of a mix of 17 common drugs which were not necessarily baseline separated in the chromatographic system used. Indeed, the complete separation of the drugs is not deemed necessary since up to 8 different ions can 'simultaneously' be selected for MS/MS if they reach the preset criteria. In addition, the quantitative performance of the method was defined. In a second phase, the developed method was field-tested. To that end, the resulting data from extracts of urine samples were compared with and found to be in close concordance with those obtained by a standard toxicological analysis. This innovative approach clearly holds the potential for a substantial advance in the introduction of LC/MS in STA.  相似文献   

9.
The field of drug metabolism has been revolutionized by liquid chromatography/mass spectrometry (LC/MS) applications with new technologies such as triple quadrupoles, ion traps and time-of-flight (ToF) instrumentation. Over the years, these developments have often relied on the improvements to the mass spectrometer hardware and software, which has allowed users to benefit from lower levels of detection and ease-of-use. One area in which the development pace has been slower is in high-performance liquid chromatography (HPLC). In the case of metabolite identification, where there are many challenges due to the complex nature of the biological matrices and the diversity of the metabolites produced, there is a need to obtain the most accurate data possible. Reactive or toxic metabolites need to be detected and identified as early as possible in the drug discovery process, in order to reduce the very costly attrition of compounds in late-phase development. High-resolution, exact mass measurement plays a very important role in metabolite identification because it allows the elimination of false positives and the determination of non-trivial metabolites in a much faster throughput environment than any other standard current methodology available to this field. By improving the chromatographic resolution, increased peak capacity can be achieved with a reduction in the number of co-eluting species leading to superior separations. The overall enhancement in the chromatographic resolution and peak capacity is transferred into a net reduction in ion suppression leading to an improvement in the MS sensitivity. To investigate this, a number of in vitro samples were analyzed using an ultra-performance liquid chromatography (UPLC) system, with columns packed with porous 1.7 mum particles, coupled to a hybrid quadrupole time-of-flight (ToF) mass spectrometer. This technique showed very clear examples for fundamental gains in sensitivity, chromatographic resolution and speed of analysis, which are all important factors for the demands of today's HTS in discovery.  相似文献   

10.
A matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometer was developed which uses a novel reflectron composed of a grounded cylinder and an adjustable endcap electrode to provide high-order kinetic energy focusing for a miniaturized mass analyzer. The nearly quadratic potential form of the reflecting field focuses ions desorbed from a source of very small dimensions formed by placing the sample probe within the centered hole of the coaxial dual channel plate detector. At the same time, the depth of the reflectron can be adjusted to accommodate a short drift length between the source/detector and the reflectron. For larger drift lengths, in particular to allow the addition of an XY stage for the analysis of sample arrays, endcap reflectron focusing can be combined with time-delayed ion extraction to achieve good mass resolution. The instrument has been used for the analysis of peptides digested with trypsin or carboxypeptidase, and also small DNA oligomers.  相似文献   

11.
A universal dual-electrospray (ESI) source is demonstrated on a quadrupole orthogonal-accelerated time-of-flight mass spectrometer (Q-ToF-MS) for both genomic and proteomic applications. This facile source modification enables internal calibration for consistent mass measurements by a mainstream MS platform and requires no mixing of analyte and calibrant prior to ion formation. In this report, the dual-sprayer is demonstrated in the negative-ion mode for internal calibration of polymerase chain reaction (PCR) amplicons generated from synthetic and genomic templates as well as a proteolytic digest of a naturally phosphorylated protein. For all PCR amplicons, experimentally determined average mass measurements are well within the instrument specifications of better than 0.01%. For the proteolytic fragments of the phosphoprotein, average mass errors of the isotopically resolved peptides are better than 10 ppm.  相似文献   

12.
Metabolism data provided with reduced cycle time has become of increasing importance for the early evaluation of DMPK properties of drugs in discovery. In this regard, quadrupole time-of-flight hybrid mass spectrometers (Q-TOF) can provide very reliable metabolite identification via accurate mass measurement of ions and the consequent access to the elemental composition of the metabolite. However, due to their cost, they are often used for drug metabolism studies on later stage drug candidates or to address challenging metabolism questions. A new prototype, consisting of a five-channel multiplexed electrospray ionization (ESI) source on a Q-TOF with one channel used for lock-mass compound infusion, was evaluated for metabolite identification. The goal was to increase the sample throughput of a single ESI-MS system by a factor of 4, while maintaining efficient metabolite separation in high-performance liquid chromatography (HPLC) as well as adequate sensitivity and mass accuracy, and ultimately improve the speed and quality of metabolism studies supporting drug discovery. The analytical performance of the system was assessed by evaluating the sensitivity and mass accuracy (using real in vitro and in vivo samples), inter-channel differences in retention times, MS/UV response, and cross-talk among channels. The sensitivity using the multiplexed ESI source was on average 2-fold lower than with single ESI, correlating well with previous literature data. The mass accuracy was comparable to that obtained using single ESI in both MS and MS/MS modes, making the metabolite identification process using the multiplexed ESI source as reliable as with single ESI. Compound-dependent differences in ionization efficiencies were observed among channels, and were minimized by analyzing related samples on the same channel. Finally, the level of cross-talk among channels was acceptable (around 0.3%) and comparable to levels previously published for quantitative applications using multiplexed ESI. The paper also focuses on the advantages and disadvantages of this new approach compared to other approaches in the literature in the field of metabolite identification.  相似文献   

13.
A heated capillary tube combined with a radio-frequency-only quadrupole has been coupled with a home- made, high-resolution orthogonal-injection, time-of-flight mass spectrometer to improve ion transmission from the atmospheric pressure to the low--pressure regions. With an electrospray ion source, the performance of the interface on the intensity of spectra was investigated. For electrospray ionization, the ion intensity detected on the time-of- flight mass spectrometer was seen to increase three-fold compared with an orifice interface. It has been shown that the enhanced ion inlet designs can not only increase the ion translation efficiency, but also improve the detection limits of the mass spectrometer. Coupling atmospheric pressure matrix-assisted laser desorption/ionization with the improved interface resulted in an instrument detection limit as low as 2.5 fmol.  相似文献   

14.
Pinto DM  Ning Y  Figeys D 《Electrophoresis》2000,21(1):181-190
The combination of microfabricated fluidic systems (muFAB) and electrospray mass spectrometers (ESI-MS) will provide multiplexed and integrated analytical systems for proteins and other biomolecules. Implementation of this novel approach requires the development of robust and user-friendly muFAB devices. Here, we present new approaches that improve the robustness, user friendliness and performance of muFAB devices coupled to MS. First, we present the development of a convenient mount to connect a muFAB device to the ESI-MS and the incorporation of filters in the reservoirs and exit of the muFAB. This mount facilitates interfacing and significantly reduces the chemical noise observed by the MS. Furthermore, we demonstrate improvements in sample handling and delivery by using either a nonaqueous electrolyte or a cationic coating on the surfaces in the muFAB device and transfer capillary. These improvements are applied to protein analysis by continuous infusion of proteolytic digests.  相似文献   

15.
An electrostatic quadrupole lens has been substituted for a cylindrical lens system used in the original inductively coupled plasma-time-of-flight mass spectrometer (ICP-TOFMS). With an improved vacuum system also installed, the cylindrical and quadrupole lenses are compared to each other and to the performance of the prototype ICP-TOFMS. The quadrupole lens requires no tradeoff between ion throughput and resolving power as was encountered with cylindrical lenses. The background noise in both ion-optical systems is within the same order of magnitude. Images of the ion beam formed by each ion-optical system have been obtained on a microchannel plate-phosphor screen. The quadrupole lens shows a higher ion-beam flux and produces a slitlike focus required in the orthogonal ICP-TOFMS instrument. Signal-to-noise ratios in the ICP-TOFMS can be improved by using a technique called pulsed-ion injection that is particularly convenient with the quadrupole lens. In this technique, one quadrupole electrode is pulsed to prevent ions from entering the extraction zone except when an ion packet is to be extracted for mass analysis. This technique significantly reduces the noise over continuous ion injection. In the orthogonal ICP-TOFMS with pulsed-ion injection, 0.5 frnol of analyte could be detected in 1.4 ms with a proper data acquisition system. Overall, the combination of a quadrupole lens and pulsed-ion injection may provide detection limits for the ICP-TOFMS that are competitive with those of quadrupole inductively coupled plasma-mass spectrometry instruments.  相似文献   

16.
Li HF  Liu J  Cai Z  Lin JM 《Electrophoresis》2008,29(9):1889-1894
The present study reports a simple method of coupling a glass microchip to an electrospray ionization (ESI) quadrupole time-of-flight mass spectrometer (QTOF-MS) for separation and identification of peptides. A sheath-flow electrospray interface was constructed based on attaching a short fused-silica capillary to the microchip. The dead volume at the interface was effectively reduced by wet etching an approximate flat-bottom capillary insertion channel coaxial to the end of separation microchannel and using a wire-controlled epoxy-blocking attachment method. The makeup liquid and neb gas were coaxially pumped through two stainless-steel tees to maintain a stable and efficient electrospray. The coupled microchip/ESI-QTOF-MS system was successfully used to carry out electrophoresis separation of peptides and ESI-QTOF-MS identification.  相似文献   

17.
A recently-developed quadrupole mass spectrometer system specifically designed for thermal analysis studies, has been linked to a thermobalance and a simultaneous TG-DTA unit, for evolved gas analysis. The performance and applicability of the system is illustrated by examples from four fields of study  相似文献   

18.
A method for carbonic anhydrase II (CA II) absolute quantification in human serum is presented. This method is based on high-performance liquid chromatography (HPLC)-Chip microfluidic device incorporating a nanoelectrospray source interfaced to a triple quadrupole mass spectrometer. The fraction containing CA II was isolated by preparative reversed-phase HPLC, and peptides obtained from the tryptic digest of the protein mixture were separated by the HPLC-Chip system. The multiple-reaction monitoring acquisition mode of a selected suitable CA II peptide and peptide internal standard allowed the selective and sensitive determination of a CA II. Absolute recovery of the method was 52 ± 12%, while analytical recovery was 81 ± 10%. For the eight samples analyzed, the matrix effect was found to be only −14 ± 6%. A comparison among three regression lines type which were obtained by external calibration, matrix-matched calibration, and standard addition method, respectively, demonstrated that the first one is adequate in obtaining good accuracy and precision. Method quantification limit for CA II in serum was estimated to be 2 fmol/mL. CA II mean concentration in sera from eight healthy subjects was found to be 56 pmol/mL (relative standard deviation 24%).  相似文献   

19.
Time-of-flight mass spectrometry (ToF-MS) has gained wide acceptance in many fields of chemistry, proteomics, metabolomics and small molecule analysis. ToF-MS, however, has some inherent advantages and drawbacks. Numerous developments have been made to hybrid ToF instruments to improve their capabilities. We have used a quadrupole orthogonal acceleration ToF (Q-oa-ToF) instrument to assess developments made to improve resolution, dynamic range and signal-to-noise (S/N) ratios (i.e. sensitivity). Higher mass resolution can improve the analysis of mixtures containing compounds with similar m/z values and improved mass accuracy gives greater confidence for structural elucidation applications. Wide dynamic ranges are necessary for the analysis of unknown samples or samples that vary widely in analyte concentrations. The performance of the advanced functionalities for routine structural elucidation in terms of resolution, dynamic range and S/N ratios was investigated using test compounds. The results presented in this work demonstrate and validate the use of these new enhancements for Q-ToF instruments and also show their limitations.  相似文献   

20.
A preliminary design and implementation of a novel approach to electrospray-mass spectrometry are described. Based on a time-of-flight mass analysis, the instrument provides several important advantages for on-line mass analysis: 1, simplicity, ease of use and low manufacturing cost; 2, rapid scan speed, yielding quasi-instantaneous full mass scans at repetition rates up to several kHz; 3, soft ionization and accurate mass determination of extremely large analyte molecules; 4, high sensitivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号