首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The adverse effect of reactive chemical residues on the quality of drug products has necessitated the determination of low-molecular-weight aldehydes in pharmaceutical excipients. An analytical methodology for the detection of trace amounts of C1-C8 aliphatic aldehydes and benzaldehyde in excipients is described. The proposed procedure is based on the derivatization of aldehydes in aqueous solution with O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine hydrochloride (PFBHA), followed by static headspace gas chromatographic (SHS-GC) analysis of PFBHA aldehyde oximes with negative chemical ionization (NCI) MS detection. The method developed was demonstrated to be simple, selective, sensitive, and was successfully applied to the screening of aldehydes at sub-microg/g levels in over 30 typical excipients. The most abundant aldehydes found in the samples were formaldehyde and acetaldehyde, for which a rapid and reliable routine quantification method by readily available SHS-GC instrumentation coupled with flame-ionization detection was also developed and validated.  相似文献   

2.
邹西梅  林竹光  彭淑女  陈招斌 《色谱》2009,27(2):169-175
开展了卷烟和烟叶中有机氯、有机磷和拟除虫菊酯3类29种农药残留的气相色谱-电子轰击离子源质谱(GC-EI/MS)的分析方法研究。优化与选择了卷烟和烟叶样品的前处理条件,样品经正己烷-丙酮(体积比为1∶1)混合提取剂超声提取、Florisil硅土和中性氧化铝双净化剂固相萃取柱净化、二氯甲烷-正己烷(体积比为95∶5)混合洗脱剂洗脱和浓缩后,以磷酸三苯酯(TPP)为内标物,采用GC-EI/MS的选择离子监测方式(SIM)进行定性和定量分析。当样品的加标水平为20,50,100 μg/kg时,加标回收率为70%~110%,相对标准偏差在2%~8%之间;除了甲氰菊酯、氯菊酯和溴氰菊酯的方法检出限(LOD)分别为1.85,1.74与2.54 μg/kg外,其余的26种农药的LOD均小于0.8 μg/kg;线性范围为5.0~500.0 μg/kg,相关系数都大于等于0.9994。此分析方法已成功地应用于卷烟和烟叶样品中3类29种痕量农药残留的分析  相似文献   

3.
A sensitive and simple method based on ultrasonication extraction with a hexane/acetone (2:1, v/v) mixture, followed by clean up of the extract by solid-phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) detection, has been developed and validated for the analysis of 20 estrogenic endocrine-disrupting chemicals (EEDCs) including phenolic xenoestrogens, synthetic and natural estrogens in river sediment. After extraction and purification, analytes are derivatised with a BSTFA/TMCS/pyridine (49:1:50, v/v/v) mixture and quantified by GC/MS. The GC/MS method involves switching between electron ionisation (EI) and chemical ionisation (CI); it also switches between selected ion storage and tandem mass spectrometry detection. The applicability of the method has been demonstrated by analysing extracts of French river sediments for which bioanalytical tests (in vitro) had already shown that they were impacted by estrogenic endocrine disrupters. The biological contribution of all the products detected in each sediment extract was compared to the estrogenic activity measured by bioassays.  相似文献   

4.
A simple, sensitive, and rapid method for determination of L‐trantinterol in rat plasma was developed for the first time by using LC coupled to MS/MS based on chiral stationary phase. A baseline separation of the enantiomers of trantinterol was achieved on a Chirobiotic V column, using a mixture of acetonitrile–methanol–ammonia–acetic acid (80:20:0.01:0.02, v/v/v/v) as the mobile phase. The detection was performed on a triple‐quadrupole tandem mass spectrometer by multiple reaction monitoring mode via ESI. The calibration curve was linear in concentration range from 0.270 to 108 ng/mL in plasma with the lower limit of quantification of 0.270 ng/mL. The intra‐ and interday precision (relative standard deviation) values were within 10.9% and the accuracy (relative error) was from 2.6 to 9.2% at all quality control levels. The method has been successfully applied to a study of L‐trantinterol pharmacokinetics in rats.  相似文献   

5.
杜鹃  赵洪霞  陈景文 《色谱》2015,33(4):348-353
建立了固相萃取-高效液相色谱-串联质谱(SPE-HPLC-MS/MS)同时检测水中6类23种抗生素的分析方法。水样用固相萃取柱富集净化,通过对比水样在不同上样pH、洗脱液用量等条件下的回收率,优化了前处理方法。采用0.1%(v/v)甲酸-1 g/L甲酸铵水溶液和甲醇-乙腈(1:1, v/v)体系作为流动相,经过梯度洗脱进行分离,在HPLC-MS/MS多反应监测模式下进行定性定量分析。结果显示,23种抗生素的方法检出限(MDL)范围为0.1~2.9 ng/L,加标回收率为47.3%~132.6%。采用该方法对东营海水养殖区5个养殖池水样进行了检测,除青霉素类之外的各类抗生素均有检出,其中磺胺增效剂甲氧苄氨嘧啶的检出率达100%,氯霉素类抗生素氟甲砜霉素检出的最高质量浓度达到261.0 ng/L。结果表明,所建立的方法高效、灵敏、可靠,可用于海水中多种抗生素的分析。  相似文献   

6.
满正印  王全林  李和生  张爱芝  沈坚 《色谱》2015,33(3):267-274
建立了超高效液相色谱-三重四极杆质谱(UPLC-MS/MS)同时测定食品级聚苯乙烯(PS)和聚乙烯(PE)色母粒中33种初级芳香胺(PAAs)的检测方法。PS色母粒用二氯甲烷溶解,超声提取后加入甲醇沉淀,并将提取液过石墨化碳固相萃取柱净化;PE色母粒用二氯甲烷超声溶胀提取;将PS色母粒过柱液和PE色母粒提取液浓缩,浓缩液用甲醇-水(1:9, v/v)定容至2 mL, 0.22 μm膜过滤后上机检测。采用BEH Phenyl色谱柱(100 mm×2.1 mm, 1.7 μm),以0.07%(v/v)甲酸甲醇溶液-水(1:9, v/v)为流动相,梯度洗脱分离,UPLC-MS/MS多反应监测(MRM)模式检测,同位素内标法定量。优化了色谱分离条件、质谱碎裂电压、碰撞能量等,并考察了提取时间、提取溶剂、浓缩方式等对回收率的影响。33种PAAs的方法检出限为6~10 μg/kg,定量限为20~30 μg/kg, 2种不同基质样品在20、100、200 μg/kg等3个添加水平的平均回收率为61.3%~119.8%,相对标准偏差(RSD)为1.4%~14.8%。本方法操作简便、快速、准确、灵敏度高,能满足相关测定要求。  相似文献   

7.
液相色谱-串联质谱法测定尿液中的内源性类固醇激素   总被引:2,自引:0,他引:2  
王萌烨  向平  严慧  沈保华  沈敏 《色谱》2008,26(1):10-14
建立了液相色谱-串联质谱(LC-MS/MS)测定尿液中的内源性类固醇激素的方法。尿样经葡萄糖醛酸甙酶酶解后进行液-液提取,以甲醇-0.1%甲酸缓冲液(含0.02 mol/L乙酸铵)(体积比为68:32)为流动相,采用Cosmosil C18色谱柱分离,并以三重四极杆串联质谱多反应监测扫描方式对尿样中的脱氢表雄酮(DHEA)、睾酮、表睾酮、雄酮和苯胆烷醇酮等5种激素进行检测。方法的最低检出限为0.01~10 ng/mL,平均回收率为96.7%~106.5%,日内和日间相对标准偏差(RSD)分别小于7%和11%。应用所建立的方法测定了健康志愿者口服DHEA后尿液中内源性类固醇激素的变化情况,结果表明该方法样品处理简便,色谱分离完全,结果准确可靠,可替代气相色谱-质谱法用于体液中内源性类固醇激素兴奋剂的常规分析。  相似文献   

8.
建立了微波辅助萃取结合气相色谱-飞行时间质谱(GC-TOF MS)技术在负化学电离(NCI)源和电子轰击电离(EI)源两种模式下测定烟草中24种农药残留的分析方法。烟叶样品于100℃下用二氯甲烷-正己烷(3:1, v/v)混合溶剂微波萃取10 min,萃取液经弗罗里硅土固相萃取柱净化后进行检测分析。在NCI源和EI源质谱模式下,24种农药的线性关系均良好(r2>0.99),相对标准偏差分别小于8.6%和9.1%,定量限分别为0.3~6.9 μg/kg和10.2~44.9 μg/kg,加标回收率分别为75.2%~94.8%和75.0%~95.1%。比较两种离子源模式下的色谱图和质谱图,NCI源模式较EI源模式的选择性好、灵敏度高、基质干扰小、图谱简单易于解析,检出限低一个数量级以上,在分析低含量、复杂基质的样品时更具优势。  相似文献   

9.
Huang Y 《色谱》2011,29(10):962-966
建立了饲料中维吉尼霉素M1的超高效液相色谱-串联质谱(UPLC-MS/MS)分析测定方法。样品用乙腈-0.2%(v/v)甲酸水溶液(8:2, v/v)超声提取两遍后,通过UPLC-MS/MS进行分析,以BEH C18色谱柱为分析柱,乙腈-0.3%(v/v)甲酸水溶液(35:65, v/v)为流动相,采用电喷雾电离正离子模式,以多反应监测模式进行定性和定量分析。在0.3~226.6 μg/L范围内线性关系良好(相关系数r=0.9995)。维吉尼霉素M1的检出限和定量限分别为2 μg/kg和7 μg/kg,平均回收率为82.6%~102.7%,相对标准偏差为0.9%~10.5%。结果表明,该方法具有操作简单、准确度和灵敏度高、重现性好的特点,适合用于检测饲料中维吉尼霉素M1的含量。  相似文献   

10.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration.  相似文献   

11.
气相色谱-串联质谱法测定土壤中的邻苯二甲酸酯   总被引:4,自引:0,他引:4  
Li H  Tian F  Ren X  Wang X 《色谱》2011,29(6):563-566
建立了土壤中6种邻苯二甲酸酯的气相色谱-串联质谱(GC-MS/MS)分析方法。土壤样品用超声提取,以二氯甲烷-丙酮(1:1, v/v)混合溶液为提取溶剂,提取液经Florisil小柱净化后,经HP-5MS色谱柱(30 m×0.25 mm×0.25 μm)分离,利用MS/MS的多反应监测(MRM)模式进行定性和定量。结果表明本方法可对样品中的邻苯二甲酸酯进行分析,在10~1000 μg/L质量浓度范围内,线性关系良好,相关系数为0.9973~0.9976;6种邻苯二甲酸酯的相对标准偏差(RSD)不大于14.3%, 2 μg/kg和10 μg/kg两个加标水平的回收率为72.9%~106.2%; 6种目标化合物的检出限为0.1~0.5 μg/kg。该方法快速准确、背景干扰较少、分析灵敏度较高,适用于土壤样品中邻苯二甲酸酯的分析。  相似文献   

12.
满正印  王全林  李和生  张爱芝 《色谱》2014,32(12):1340-1348
建立了超高效液相色谱-三重四极杆质谱法(UPLC-MS/MS)同时测定水粉画颜料、油画颜料、丙烯画颜料等美术颜料中33种初级芳香胺(PAAs)的检测方法。样品中的初级芳香胺用乙腈提取,经离心分离、氮吹浓缩后,以甲醇-水(1:9, v/v)定容至2 mL, 0.22 μm膜过滤后上机检测。采用BEH Phenyl柱(100 mm×2.1 mm, 1.7 μm),以含0.07%(v/v)甲酸的甲醇溶液-水(1:9, v/v)为流动相,梯度洗脱分离,UPLC-MS/MS多反应监测模式(MRM)检测,同位素内标法定量。方法优化了色谱分离条件、质谱碎裂电压、碰撞能量等,并考察了提取时间、提取溶剂、浓缩方式等对回收率的影响。33种初级芳香胺的方法检出限为5~50 μg/kg,定量限为15~150 μg/kg, 3种不同基质样品在3个添加水平的平均回收率为70.1%~115.8%,相对标准偏差(RSD)为2.1%~15%。本方法操作简便、快速、准确、灵敏度高,能满足相关测定的要求。  相似文献   

13.
A method has been developed and validated for the concurrent extraction, clean‐up, and analysis of polybrominated diphenyl ethers (PBDEs), α‐, β‐, and γ‐hexabromocyclododecane (HBCD), and tetrabromobisphenol A (TBBPA) in human milk and serum. Milk and serum samples were extracted using accelerated solvent extraction with acetone/hexane 1:1, v/v and liquid–liquid extraction with methyl‐tert‐butyl ether/hexane 1:1, v/v, respectively. The removal of co‐extracted biogenic materials was achieved by gel permeation chromatography followed by sulfuric acid treatment. The fractionation of the PBDEs and HBCD/TBBPA was performed using a Supelco LC‐Si SPE cartridge. The detection of the PBDEs was then performed by GC–MS and that of the HBCDs and the TBBPA was performed using UPLC–MS/MS. The pretreatment procedure was optimized, and the characteristic ions and fragmentation of the analytes were studied by MS or MS/MS. A recovery test was performed using a matrix spiking test at concentrations of 0.05–10 ng/g. The recoveries ranged from 78.6–108.8% with RSDs equal to or lower than 14.04%. The LODs were 1.8–60 pg/g. The usefulness of the developed method was tested by the analysis of real human samples, and several brominated flame retardants in different samples were detected and analyzed.  相似文献   

14.
建立了高效液相色谱-电喷雾串联质谱(HPLC-ESI MS/MS)分析环境水样中22种抗生素类药物的方法。采用HLB固相萃取柱对环境水样中的目标化合物进行富集、净化,然后以6 mL氨水-甲醇(5:95, v/v)溶液洗脱。收集的洗脱液经氮气吹干至1 mL,然后进行HPLC-ESI MS/MS分离分析。色谱流动相A相为甲醇-乙腈(1:1, v/v), B相为0.3%(体积分数)甲酸水溶液(含0.1%(体积分数)甲酸铵,pH 2.9);色谱柱为XTerra MS C18柱。质谱检测采用正离子扫描,多反应监测模式。分别以自来水和污水作为基质,22种抗生素类药物的加标平均回收率分别为54.9%~130%和57.4%~138%,相对标准偏差(n=3)分别为2.85%~28.6%和2.02%~23.2%;方法的检出限为0.05~0.5 ng/L。将建立的方法应用于北京市高碑店湖和小清河水样的分析,结果表明在两个水样中均有部分抗生素类药物检出。  相似文献   

15.
A new and sensitive methodology based on normal phase HPLC has been developed for the speciation of nickel in low-complexity plant extracts. The method combines a silica stationary phase column, a 9:1 (v/v) hexane:ethanol mixture as mobile phase, and the detection of nickel complexes by either UV or MS. The developed methodology was applied to the speciation of nickel complexes in the cytoplasm of pea root nodules. Results obtained indicate that nickel citrate and nickel malate accounts for 99% of nickel present in pea nodule cytoplasm fraction. The low detection limit of the method (<0.2 nM) enables nickel speciation in non-hyperaccumulator plants.  相似文献   

16.
A rapid multiple toxin method based on liquid chromatography with mass spectrometry (LC/MS) was developed for the detection of okadaic acid (OA), dinophysistoxin-1 (DTX-1), DTX-2, yessotoxin (YTX), homoYTX, 45-hydroxy-YTX, 45-hydroxyhomo-YTX, pectenotoxin-1 (PTX-1), PTX-2, azaspiracid-1 (AZA-1), AZA-2, and AZA-3. Toxins were extracted from shellfish using methanol-water (80%, v/v) and were analyzed using a C8 reversed-phase column with a 5 mM ammonium acetate-acetonitrile mobile phase under gradient conditions. The method was validated for the quantitative detection of OA, YTX, PTX-2, and AZA-1 in 4 species (mussels, Mytilus edulis; cockles, Cerastoderma edule; oysters, Crassostrea gigas; king scallop, Pecten maximus) of shellfish obtained from United Kingdom (UK) waters. Matrix interferences in the determination of the toxins in these species were investigated. The validated linear range of the method was 13-250 microg/kg for OA, PTX-2, and AZA-1 and 100-400 microg/kg for YTX. Recovery and precision ranged between 72-120 and 1-22%, respectively, over a fortification range of 40-160 microg/kg for OA, PTX-2, and AZA-1 and 100-400 microg/kg for YTX. The limit of detection, reproducibility, and repeatability of analysis showed acceptable performance characteristics. A further LC/MS method using an alkaline hydrolysis step was assessed for the detection of OA, DTX-1, and DTX-2 in their esterified forms. In combination with the LC/MS multiple toxin method, this allows detection of all toxin groups described in Commission Decision 2002/225/EC.  相似文献   

17.
In this study, a sensitive and selective method based on liquid chromatography combined with diode array and tandem mass spectrometry detection (LC-DAD-MS/MS) was developed for the simultaneous quantitative determination of fenofibric acid, pravastatin and its main metabolites in human plasma. In this method, an automated solid-phase extraction (SPE) on disposable extraction cartridges (DECs) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-DAD-MS/MS system. On-line LC-DAD-MS/MS system using an atmospheric pressure ionization (TurboIonSpray) was then developed for the simultaneous determination of pravastatin, 3-hydroxy isomeric metabolite (3-OH metab), pravalactone and fenofibric acid. The separation is obtained on an endcapped dodecyl silica based stationary phase using a mobile phase consisting of a mixture of acetonitrile, methanol and 5mM ammonium acetate solution (30:30:40, v/v/v). Sulindac and triamcinolone were used as internal standards (ISs). The detection of the fenofibric acid and sulindac was achieved by means of a DAD system. The MS/MS ion transitions monitored were m/z 442.2-->269.1, 442.2-->269.1, 424.3-->183.0 and 435.2-->397.2 for pravastatin, 3-OH metab, pravalactone and triamcinolone, respectively. The method was validated regarding stability, selectivity, extraction efficiency, response function, trueness, precision lower limit of quantitation and matrix effect. The limits of quantitation (LOQs) were around 0.50 ng/ml for pravastatin, 0.25 ng/ml for 3-OH metab, 0.05 ng/ml for pravalactone and 0.25 microg/ml for fenofibric acid.  相似文献   

18.
李军  许烨  隋凯  卫锋  赵守成  王玉萍 《色谱》2006,24(3):256-259
建立了免疫亲和柱净化/柱前衍生化-高效液相色谱荧光检测器测定粮谷中T-2毒素含量的方法。样品经甲醇-水(体积比为80∶20)混合溶剂提取,通过免疫亲和柱(IAC)净化,以氰酸蒽(1-AN)为衍生化试剂、4-二甲基氨基吡啶(DMAP)为催化剂进行衍生,以ZORBAX Eclipse XDB-C18 柱为分离柱,乙腈-水(体积比为80∶20)为流动相进行高效液相色谱分离及荧光检测,荧光检测的激发波长为381 nm,发射波长为470 nm。T-2毒素的质量浓度为0.01~1.5 mg/L时与峰高呈良好的线性,相关系数为0.9985。在0.01~1.5 μg/g添加水平下,回收率为79.7%~94.5%,相对标准偏差小于7%;检出限(S/N=3)为0.01 μg/g。该方法净化效果好,灵敏度高,操作简便快速。  相似文献   

19.
In the present study, a reverse-phase high performance liquid chromatography method was developed, validated and applied for the simultaneous determination of gliquidone, pioglitazone hydrochloride and verapamil in tablets and human serum. Chromatographic separation was achieved on a C18 column (5 μm, 25 × 0.46 cm) with a mobile phase consisting of methanol-water-acetonitrile (80:10:10 v/v/v) with a flow rate of 0.7 mL/min and pH adjusted to 3.50 with phosphoric acid at 230 nm. Glibenclamide was used as internal standard. The experimentally derived limit of detection and limit of quantitation were determined to be 0.24, 0.93, 0.40, and 0.80, 3.11, 1.36 μg/mL for gliquidone, pioglitazone, and verapamil, respectively. There were no interfering peaks due to the excipients present in the pharmaceutical tablets. Thus, the proposed method is simple and suitable for the simultaneous analysis of active ingredients in dosage forms and human serum.  相似文献   

20.
Glycidyl fatty acid esters in food by LC-MS/MS: method development   总被引:1,自引:0,他引:1  
An improved method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the analysis of glycidyl fatty acid esters in oils was developed. The method incorporates stable isotope dilution analysis (SIDA) for quantifying the five target analytes: glycidyl esters of palmitic (C16:0), stearic (C18:0), oleic (C18:1), linoleic (C18:2) and linolenic acid (C18:3). For the analysis, 10 mg sample of edible oil or fat is dissolved in acetone, spiked with deuterium labelled analogs of glycidyl esters and purified by a two-step chromatography on C18 and normal silica solid phase extraction (SPE) cartridges using methanol and 5% ethyl acetate in hexane, respectively. If the concentration of analytes is expected to be below 0.5 mg/kg, 0.5 g sample of oil is pre-concentrated first using a silica column. The dried final extract is re-dissolved in 250 μL of a mixture of methanol/isopropanol (1:1, v/v), 15 μL is injected on the analytical C18 LC column and analytes are eluted with 100% methanol. Detection of target glycidyl fatty acid esters is accomplished by LC-MS/MS using positive ion atmospheric pressure chemical ionization operating in Multiple Reaction Monitoring mode monitoring 2 ion transitions for each analyte. The method was tested on replicates of a virgin olive oil which was free of glycidyl esters. The method detection limit was calculated to be in the range of 70-150 μg/kg for each analyte using 10 mg sample and 1-3 μg/kg using 0.5 g sample of oil. Average recoveries of 5 glycidyl esters spiked at 10, 1 and 0.1 mg/kg were in the range 84% to 108%. The major advantage of our method is use of SIDA for all analytes using commercially available internal standards and detection limits that are lower by a factor of 5-10 from published methods when 0.5 g sample of oil is used. Additionally, MS/MS mass chromatograms offer greater specificity than liquid chromatography-mass spectrometry operated in selected ion monitoring mode. The method will be applied to the survey of glycidyl fatty acid esters in food products on the Canadian market.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏