1.
Dynamic slice-wise shimming improves B0 field homogeneity by updating shim coil currents for every slice in a multislice acquisition, producing better field homogeneity over a volume than can be obtained by a single static global shim. The first aim of this work was to evaluate the performance of slice-wise field-map-based second-order dynamic shimming in a human high-field 7 T clinical scanner vis-à-vis image based second order static global shimming. Another goal was to characterize eddy currents induced by second and third order shim switching. A final aim was to compare global and dynamic shimming through shim orders to elucidate the relative benefits of going to higher orders and to dynamic shim updating from a static shimming regime. An external hardware module was used to store and dynamically update slice-optimized shim values during multislice data acquisition. High-bandwidth multislice gradient echo scans with B0 field mapping and low-bandwidth single-shot echo planar scans were performed on phantoms and humans using second-order dynamic and static global shims. For the measurement of second and third order shim induced eddy currents, step response temporal phase changes of individual shims were measured and fit to shim harmonics spatially and to multiexponential decay functions temporally. Finally, an order-wise field-map-based comparison was performed with first, second and third order global static shimming, first and second order dynamic shimming, as well as combined second or third order global and first order dynamic shim. Dynamic shimming considerably improved B0 homogeneity compared to static global shimming both in phantoms and in human subjects, reducing image distortion and signal dropout. The unshielded second and third order shims generated strong B0 and self and cross-term eddy fields, with multiple time constants ranging from milliseconds to seconds. Field homogeneity improved with increasing order of shim, with dynamic shimming performing better than global shimming. Hybrid global and dynamic shimming approach yielded field homogeneity better than global static shims but worse than dynamic shims.  相似文献   

2.
Dynamic shim updating on the human brain   总被引:1,自引:0,他引:1  
Dynamic alteration of shim settings during a multi-slice imaging experiment can improve static magnetic-field homogeneity over extended volumes. In this report, a pre-emphasized dynamic shim updating (DSU) system capable of rapidly updating all non-degenerate zeroth through second-order shims is presented and applied to high-field multi-slice imaging studies on the human brain. DSU is utilized in both non-oblique and oblique slicing geometries while updating in-plane and through-slice shims. Image-based magnetic-field maps are used to quantify homogeneity improvements and comparisons are made on a slice-specific basis between static global shimming and increasing orders of shim inclusion utilized DSU. The influence of oblique slicing geometry on DSU-utilized global homogeneity is also quantified computationally. Finally, the effect of DSU on susceptibility artifact reduction in single-shot axial-sliced EPI is analyzed using experimental acquisitions.  相似文献   

3.
In vivo B(0) inhomogeneity in the rat brain at 11.7 Tesla was measured and decomposed up to the fourth-order spherical harmonic terms using an automatic slice shimming routine derived from the FLATNESS method. In vivo shimming of horizontal slices showed that significant improvement in the T(2)*-weighted echo-planar imaging was achieved after correction of all first-, second- and third-order in-slice shims. For localized proton spectroscopy, reproducible, high quality data were obtained after correcting all first- and second-order shims. The measured high-order in vivo B(0) inhomogeneity in terms of spherical harmonic terms should provide a useful guide for designing shims to meet in vivo requirements.  相似文献   

4.
High-spatial-resolution acquisition (HR) was previously proposed for 3D echo-planar spectroscopic imaging (EPSI) in combination with a high-spatial-resolution water reference EPSI data set to minimize inhomogeneous spectral line broadening, allowing for local frequency shift (B(0) shift) correction in human brain metabolite maps at 1.5 T (Ebel A et al., Magn. Reson. Imaging 21:113-120, 2003). At a higher magnetic field strength, B(0), increased field inhomogeneities typically lead to increased line broadening. Additionally, increased susceptibility variations render shimming of the main magnetic field over the whole head more difficult. This study addressed the question whether local B(0)-shift correction still helps limit line broadening in whole-brain 3D EPSI at higher magnetic fields. The combination of HR and local B(0)-shift correction to limit line broadening was evaluated at 4 T. Similar to the results at 1.5 T, the approach provided a high yield of voxels with good spectral quality for 3D EPSI, resulting in improved brain coverage.  相似文献   

5.
The first step in the process of shimming a magnetic field is to characterize it by obtaining a field map and decomposing that map into a convenient set of basis functions. The strength of each member of the set is then calculated. Finally, a set of correction elements which generate fields corresponding to the same spatial distribution as the basis functions is energized so that the sum of their fields and the error fields is substantially zero. The basis functions used typically are solutions to Laplace’s equation and have been shown to be very effective when the region of interest is substantially free space. This paper addresses issues associated with shimming the magnetic field in a region in which there is a distribution of materials with different susceptibilities and which therefore is not free space. In such a region, Laplace’s equation is no longer valid and in principle cannot be used to describe the magnetic field there. It is demonstrated that in spite of this, the same set of basis functions suffices for analyzing the field and the same set of elements suffices for correcting the field. The motivation for this study stems from the need to improve the magnetic field homogeneity when biological specimens are being imaged by magnetic resonance. In particular, this paper describes a study carried out by various simulated shimming strategies to improve the uniformity of the magnetic field over a multitissue model of susceptibility of the human head. The topics of magnetic susceptibility, the effect of shimming on MR images, shimming hardware and shimming methods are briefly reviewed. Two slices of the human head model were selected for detailed study, both offset inferior to the origin and including the base of the brain and the anterior sinus. The results of the study include comparisons between the strategies of global shimming, local slice-selective shimming and combinations of the two; the effects of shimming to various orders of spherical harmonics; and the effects of rotation and displacement of the head with respect to the shim frame of reference.  相似文献   

6.
The use of high magnetic fields increases the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS) of brain metabolites. Practical limitations arise, however, from susceptibility-induced field distortions, which are increased at higher magnetic field strengths. Solutions to this problem include optimized shimming, provided that active, i.e., electronic, shimming can operate over a sufficient range. To meet our shim requirements, which were an order of magnitude greater than the active shim capacity of our 7T MR system, we developed a combined passive and active shim approach. Simple geometries of ferromagnetic shim elements were derived and numerically optimized to generate a complete set of second-order spherical harmonic shim functions in a modular manner. The major goals of the shim design were maximization of shim field accuracy and ease of practical implementation. The theoretically optimized ferro-shim geometries were mounted on a cylindrical surface and placed inside the magnet bore, surrounding the subject's head and the RF coil. Passive shimming generated very strong shim fields and eliminated the worst of the field distortions, after which the field was further optimized by flexible and highly accurate active shimming. Here, the passive-shimming procedure was first evaluated theoretically, then applied in phantom studies and subsequently validated for in vivo 1H MRS in the macaque visual cortex. No artifacts due to the passive shim setup were observed; adjustments were reproducible between sessions. The modularity and the reduction to two pieces per shim term in this study is an important simplification that makes the method applicable also for passive shimming within single sessions. The feasibility of very strong, flexible and high-quality shimming via a combined approach of passive and active shimming is of great practical relevance for MR imaging and spectroscopy at high field strengths where shim power is limited or where shimming of specific anatomical regions inherently requires strong shim fields.  相似文献   

7.
High quality magnetic field homogenization of the human brain (i.e. shimming) for MR imaging and spectroscopy is a demanding task. The susceptibility differences between air and tissue are a longstanding problem as they induce complex field distortions in the prefrontal cortex and the temporal lobes. To date, the theoretical gains of high field MR have only been realized partially in the human brain due to limited magnetic field homogeneity.A novel shimming technique for the human brain is presented that is based on the combination of non-orthogonal basis fields from 48 individual, circular coils. Custom-built amplifier electronics enabled the dynamic application of the multi-coil shim fields in a slice-specific fashion. Dynamic multi-coil (DMC) shimming is shown to eliminate most of the magnetic field inhomogeneity apparent in the human brain at 7 T and provided improved performance compared to state-of-the-art dynamic shim updating with zero through third order spherical harmonic functions. The novel technique paves the way for high field MR applications of the human brain for which excellent magnetic field homogeneity is a prerequisite.  相似文献   

8.
Dynamic B(0) shimming (DS) can produce better field homogeneity than static global shimming by dynamically updating slicewise shim values in a multislice acquisition. The performance of DS however is limited by eddy current fields produced by the switching of 2nd and 3rd order unshielded shims. In this work, we present a novel method of eddy field compensation (EFC) applied to higher order shim induced eddy current fields in multislice DS. This method does not require shim shielding, extra hardware for eddy current compensation or subject specific prescanning. The interactions between shim harmonics are modeled assuming steady state of the medium and long time constant, cross and self term eddy fields in a DS experiment and 'correction factors' characterizing the entire set of shim interactions are derived. The correction factors for a given time between shim switches are shown to be invariable with object scanned, shim switching pattern and actual shim values, allowing for their generalized prospective use. Phantom and human head, 2nd and 3rd order DS experiments performed without any hardware eddy current compensation using the technique show large reductions in field gradients and offsets leading to significant improvements in image quality. This method holds promise as an alternative to expensive hardware based eddy current compensation required in 2nd and 3rd order DS.  相似文献   

9.
Image segmentation is used increasingly to interpret MR spectroscopic data of the brain, using image contrast to identify gray matter (GM), white matter (WM), and cerebral spinal fluid (CSF). T(1)- or T(2)-weighted images are typically used, but poor shimming, susceptibility effects, and small variations in B(1) and receptivity cause difficulties in tissue identification. Quantitative imaging of T(1) can reduce many of these difficulties but is still subject to complications when B(1) has large variations like those observed with the surface coils often used for spectroscopy. In this study, B(1) imaging was implemented to support quantitative imaging of T(1) with either a surface coil or a volume coil. The T(1) observed by this method is a continuous function across mixtures of WM/GM and GM/CSF, and this function was measured and used to convert the images of T(1) to maps of percent GM, WM, and CSF.  相似文献   

10.
With improved B 0 homogeneity along with satisfactory gradient performance at high magnetic fields, snapshot gradient-recalled echo-planar imaging (GRE-EPI) would perform at long echo times (TEs) on the order of T2*, which intrinsically allows obtaining strongly T2*-weighted images with embedded substantial anatomical details in ultrashort time. The aim of this study was to investigate the feasibility and quality of long TE snapshot GRE-EPI images of rat brain at 9.4 T. When compensating for B 0 inhomogeneities, especially second-order shim terms, a 200 x 200 microm2 in-plane resolution image was reproducibly obtained at long TE (>25 ms). The resulting coronal images at 30 ms had diminished geometric distortions and, thus, embedded substantial anatomical details. Concurrently with the very consistent stability, such GRE-EPI images should permit to resolve functional data not only with high specificity but also with substantial anatomical details, therefore allowing coregistration of the acquired functional data on the same image data set.  相似文献   

11.
An ultrashort-echo-time stimulated echo-acquisition mode (STEAM) pulse sequence with interleaved outer volume suppression and VAPOR (variable power and optimized relaxation delays) water suppression was redesigned and optimized for human applications at 4 and 7 T, taking into account the specific requirements for spectroscopy at high magnetic fields and limitations of currently available hardware. In combination with automatic shimming, automated parameter adjustments and data processing, this method provided a user-friendly tool for routine1H nuclear magnetic resonance (NMR) spectroscopy of the human brain at very high magnetic fields. Effects of first- and second-order shimming, single-scan averaging, frequency and phase corrections, and eddy currents were described. LCModel analysis of an in vivo1H NMR spectrum measured from the human brain at 7 T allowed reliable quantification of more than fifteen metabolites noninvasively, illustrating the potential of high-field NMR spectroscopy. Examples of spectroscopic studies performed at 4 and 7 T demonstrated the high reproducibility of acquired spectra quality.  相似文献   

12.
磁场的高均匀性是高性能核磁共振弛豫分析仪实现短弛豫时间样品和微弱信号核磁共振(NMR)检测的基本保障.该文以0.45 T双极型永磁体作为设计核心部件,在大范围磁体空间-25.4 mm球空间(DSV)内,基于目标场法设计了X、Y、Z、XY、XZ、YZ、Z2共7组有源匀场线圈,根据线圈供电要求,设计了可编程恒流电源,搭建了可用于高性能核磁共振弛豫分析仪磁体的有源匀场系统,介绍了系统的基本结构、设计过程及匀场方法.实验测试结果验证了大范围磁体空间内该匀场系统的实用性.  相似文献   

13.
Dynamic shimming in multi-slice imaging aims to achieve optimal magnetic field homogeneity by updating the shim coil currents for each slice in real time. Dynamic shimming may reduce the signal loss and geometric distortion caused by magnetic susceptibility variations between tissues and is likely to be valuable for fast T2*-sensitive imaging techniques like EPI. A computer simulation of dynamic shimming using real image data has been developed to demonstrate the effectiveness of higher order dynamic shimming for echo planar imaging at high magnetic field, and to investigate the potential benefits of different orders of shim coil. Geometric distortions and signal intensities for different degrees of dynamic shimming were simulated and the results are compared with the images obtained with a conventional shimming technique. These results demonstrate the effectiveness, necessity and difficulty of high order dynamic shimming.  相似文献   

14.
唐昕  洪礼明  俎栋林 《中国物理 B》2010,19(7):78702-078702
This paper presents an approach of active ferromagnetic shimming for C-type permanent magnetic resonance imaging (MRI) magnet.It is designed to reduce inhomogeneity of magnetostatic field of C-type permanent magnet to meet the stringent requirement for MRI applications.An optimal configuration (locations and thicknesses) of active ferromagnetic pieces is generated through calculation according to the initial field map and the demanded final homogeneity specifications.This approach uses a minimisation technique which makes the sum of squared magnetic moment minimum to restrict the amount of the active ferromagnetic material used and the maximal thickness of pieces stacked at each hole location in the shimming boards.Simulation and experimental results verify that the method is valid and efficient.  相似文献   

15.
A subject-specific local in vivo passive shimming method, focusing on the prefrontal and temporal regions, is proposed. The aim of the investigation is to show that subject variability exists in optimal passive shimming and that the proposed method can be effectively used to overcome these differences. A shimming structure capable of adjusting the position of the passive shims to within a millimeter resolution is built. The optimal shim positions for each individual subject are computed from obtained field map using a convex optimization algorithm. Passive shim experiments at predetermined fixed shim positions vs. individually adjusted shim positions were performed and compared. The results show that intersubject variability exists in the optimal shim positions and that the location-sensitive method proposed can be useful for improving main field homogeneity in vivo.  相似文献   

16.
The high soprano range was investigated by acoustic and electroglottographic measurements of 12 sopranos and high-speed endoscopy of one of these. A single laryngeal transition was observed on glissandi above the primo passaggio. It supports the existence of two distinct laryngeal mechanisms in the high soprano range: M2 and M3, underlying head and whistle registers. The laryngeal transition occurred gradually over several tones within the interval D#5-D6. It occurred over a wider range and was completed at a higher pitch for trained than untrained sopranos. The upper limit of the laryngeal transition during glissandi was accompanied by pitch jumps or instabilities, but, for most singers, it did not coincide with the upper limit of R1:f(0) tuning (i.e., tuning the first resonance to the fundamental frequency). However, pitch jumps could also be associated with changes in resonance tuning. Four singers demonstrated an overlap range over which they could sing with a full head or fluty resonant quality. Glottal behaviors underlying these two qualities were similar to the M2 and M3 mechanisms respectively. Pitch jumps and discontinuous glottal and spectral changes characteristic of a M2-M3 laryngeal transition were observed on decrescendi produced within this overlap range.  相似文献   

17.
There has been a lack of objective data on the singing voice registers, particularly on the so called "whistle" register, occurring in the top part of the female pitch range, which is accessible only to some singers. This study offers unique strobolaryngoscopic and high-speed (7812.5 imagess) videokymographic data on the vocal fold behavior of an untrained female singer capable of producing three distinct voice qualities, i.e., the chest, head and whistle registers. The sound was documented spectrographically. The transition from chest to head register, accompanied by pitch jumps, occurred around tones B4-C#5 (500-550 Hz) and was found to be associated with a slight decrease in arytenoids adduction, resulting in decrease of the closed quotient. The register shifts from head to whistle, also accompanied by pitch jumps, occurred around tones E5-B5 (670-1000 Hz) without any noticeable changes in arytenoids adduction. Some evidence was found for the vocal tract influence on this transition. The mechanism of the vocal fold vibration in whistle register was found principally similar to that at lower registers: vibrations along the whole glottal length and vertical phase differences (indicated by sharp lateral peaks in videokymography) were seen on the vocal folds up to the highest tone G6 (1590 Hz).  相似文献   

18.
杜晓纪  王为民  兰贤辉  李超 《物理学报》2017,66(24):248401-248401
磁共振成像(magnetic resonance imaging,MRI)是当今世界上最先进的医学影像技术之一,现阶段MRI技术正朝着成像质量更清晰、功能更强大、效率更高、个体化更强的趋势发展.与全身MRI设备相比,专科型MRI设备具有体积小、重量轻、成本低、病人舒适度高、成像质量高、功能更强等优点.但是关节专用超导MRI系统需要长度方向上被严格限制的超导磁体在160 mm直径球域(diameter sphere volume,DSV)内产生高均匀度的磁场.本文综合考虑了超导线用量、中心磁感应强度和成像区磁场不均匀度等因素,使用0-1规划和遗传算法相结合的方法设计了一种非屏蔽型1.5 T关节MRI超导磁体,该磁体的室温孔径为280 mm,总长度为520 mm,液氦量为30 L,载流区最大磁场为5.48 T,5高斯线范围为径向3.2 m、轴向2.6 m,160 mm DSV的磁场不均匀度设计值为22 ppm,考虑加工误差及冷缩因素,磁体加工完成并经过被动匀场后的预估值为60 ppm.经过绕制、固化、组装、焊接等工序,该磁体已制作完成.经过3次锻炼后成功励磁到1.5 T,经过被动匀场后160 mm DSV的磁场不均匀度达到50 ppm,各项指标均达到设计目标.  相似文献   

19.
Thresholds (F0DLs) were measured for discrimination of the fundamental frequency (F0) of a group of harmonics (group B) embedded in harmonics with a fixed F0. Miyazono and Moore [(2009). Acoust. Sci. & Tech. 30, 383386] found a large training effect for tones with high harmonics in group B, when the harmonics were added in cosine phase. It is shown here that this effect was due to use of a cue related to pitch pulse asynchrony (PPA). When PPA cues were disrupted by introducing a temporal offset between the envelope peaks of the harmonics in group B and the remaining harmonics, F0DLs increased markedly. Perceptual learning was examined using a training stimulus with cosine-phase harmonics, F0 = 50 Hz, and high harmonics in group B, under conditions where PPA was not useful. Learning occurred, and it transferred to other cosine-phase tones, but not to random-phase tones. A similar experiment with F0 = 100 Hz showed a learning effect which transferred to a cosine-phase tone with mainly high unresolved harmonics, but not to cosine-phase tones with low harmonics, and not to random-phase tones. The learning found here appears to be specific to tones for which F0 discrimination is based on distinct peaks in the temporal envelope.  相似文献   

20.
PurposeTo evaluate the performance of combined integrated slice-by-slice shimming and readout-segmented EPI (irsEPI) for diffusion-weighted MR imaging (DWI) of the neck at 3 Tesla.MethodsThis study was approved by the local ethics committee. An anthropometric phantom of the head/neck region incorporating compartments with different diffusivities was constructed. In vivo measurements were performed in 10 healthy volunteers. DWI of the phantom and volunteers was performed on a 3 Tesla MR scanner using single shot EPI (sEPI), a prototype single shot EPI with integrated slice-by-slice shimming (iEPI), readout segmented EPI (rsEPI) and a prototype readout segmented EPI with integrated shimming irsEPI. Apparent diffusion coefficients (ADC) and spatial distortions of phantom compartments were quantified. For phantom and volunteer measurements, the presence of geometric distortions, signal losses, ghosting artifacts as well as overall image quality were visually assessed on a 4-point scale by two radiologists in consensus. In addition, failure of fat saturation was assessed in volunteer data.ResultsQuantification of ADC within the phantom compartments was comparable using the different EPI techniques without significant variations. Using irsEPI, spatial distortions in phase-encoding direction were markedly reduced compared to iEPI, rsEPI and especially sEPI. irsEPI yielded significantly better overall image quality compared to sEPI, iEPI and rsEPI in phantom data as well as volunteer measurements. Markedly reduced geometric distortions and signal loss as well as better fat saturation were observed using irsEPI.ConclusionThe use of irsEPI significantly improves image quality and reduces artifacts caused by magnetic field inhomogeneities in EPI based DWI of the head/neck at 3 Tesla.  相似文献   