A high-performance liquid chromatographic method with UV detection has been developed for the determination of saikosaponin a in rat plasma. Saikosaponin a and internal standard jujuboside A were isolated from plasma samples by solid-phase extraction. The chromatographic separation was achieved on a reversed-phase C(18) column with the mobile phase of acetonitrile-water (35:65, v/v) at a flow rate of 1 mL/min and UV detection was set at 205 nm. The standard curve for saikosaponin a was linear over the concentration range 0.25-10 microg/mL and the limit of detection was 0.05 microg/mL. The absolute recovery was greater than 82%. The precision and accuracy ranged from 3.05 to 9.59% and 95.61 to 110.00%, respectively. The validated method was used to determine saikosaponin a in plasma samples in a pharmacokinetic study of saikosaponin a administered to Sprague-Dawley rats.  相似文献   

2.
An on-column complexation method has been developed for the simultaneous determination of V(IV) and V(V). Vanadium species were chelated with aminopolycarboxylic acids to form anionic complexes which were separated by capillary zone electrophoresis (CZE) with direct UV detection. Ethylenediaminetetraacetic acid (EDTA), diethylenetriaminepentacetric acid (DTPA), nitrilotriacetic acid (NTA), and N-2-hydroxyethylethlendiaminetriacetric acid (HEDTA) were investigated as both ligand and running electrolyte. Of the ligands studied the complexes of EDTA with V(IV) and V(V) resulted in the highest selectivity and UV response.The conditions used for on-column complexation and separation, including pH, and electrolyte ligand concentration, were examined to achieve reasonable separation selectivity and detection sensitivity. The optimum separation of the anionic forms of V(IV) and V(V) was obtained by use of CZE with UV detection at 185 nm and an electrolyte containing 5 mmol L(-1) EDTA at pH 4.0. Linear calibration plots were obtained in the concentration range10-300 micro mol L(-1); detection limits were 3 micro mol L(-1) for V(IV) and 1 micro mol L(-1) for V(V). The proposed method was demonstrated for the determination of vanadium in groundwater spiked with V(IV) and V(V).  相似文献   

3.
In this paper, the use of an ion-pairing reagent to improve the separation selectivity of inorganic anions in CZE was demonstrated by the addition of tetramethylammonium hydroxide (TMAOH) to the electrolyte. The separation of inorganic anions (Cl(-), I(-), Br(-), NO(2)(-), NO(3)(-) and SCN(-)) was performed using co-electroosmotic flow (EOF) with direct UV detection at 185 nm. The parameters affecting the mobility of the tested anions and the EOF such as the electrolyte pH and concentration of TMAOH in the electrolyte were examined to optimise the separation conditions. In addition, sample-stacking techniques were investigated to improve detection sensitivity. Detection sensitivities were improved 5-13-fold using electrokinetic sample stacking. The detection limits ranged from 1-3 micro mol L(-1). Finally, the proposed method was used for the separation of anions in groundwaters.  相似文献   

4.

Co-electroosmotic capillary electrophoresis (co-CZE) with both direct and indirect UV detection was investigated for the separation of sulfur species. With direct UV detection, the separation of S2O2? 3, S2O2? 4 was possible using 20 mM phosphate electrolyte containing 0.75 mM tetradecyltrimethylammonium bromide (TTAB) and 15% acetonitrile. To obtain optimal peak shape and sensitivity using indirect UV detection, a range of background electrolytes (BGEs), including benzoate, phthalate, 2,6-pyridinedicarboxylate (2,6-PDCA) and trimellitate, were examined as the BGEs. Of all the BGEs, 2,6-PDCA gave high selectivity and indirect UV response due to its mobility matching to that of sulfur species and its high absorptivity. Detection limits in range of 3-6 μM were obtained using either direct UV or indirect UV detection. The proposed CZE methods were used for the determination of sulfur species in water samples, and provided fast separation of sulfur species in less than 5 min.  相似文献   

5.
Vitamin B12, cobalt protoporphyrin, manganese protoporphyrin, and zinc protoporphyrin were separated using capillary electrophoresis, and a comparison was made between detection with inductively coupled plasma mass spectrometry (ICP-MS) and UV detection. Absolute limits of detection were slightly better with ICP-MS detection than with UV detection, but for both methods absolute detection limits were in the picogram range. The migration times of the analytes decreased by several minutes when ICP MS detection was employed, and this phenomenon was believed to be a result of a "suction effect" that developed when the CE capillary was interfaced to the ICP-MS nebulizer. However, the resolution between species containing the same metal atom was not altered significantly, and the separation was completed in much less time relative to separations performed with UV detection.  相似文献   

6.
1-Anilinonaphthalene-8-sulfonic acid (1,8-ANS), 4,4'-dianilino-1,1'-binaphthyl-5,5'-disulfonic acid (bis-ANS) and 2-(p-toluidino)naphthalene-6-sulfonic acid (2,6-TNS) were evaluated as additives in different buffers for the detection of bovine whey proteins using laser-induced fluorescence (LIF) monitoring in capillary electrophoresis (CE). These N-arylaminonaphthalene sulfonates furnish a large fluorescence emission when associated to some proteins whereas their emission in aqueous buffers, such as those used in CE separations, is very small. To select the best detection conditions, the fluorescence of these probes was first compared using experiments carried out in a fluorescence spectrophotometer. Using bovine serum albumin (BSA) as a model protein, it was demonstrated that 2-(N-cyclohexylamino)ethanesulfonic acid (CHES) buffer (pH 8 and pH 10.2) and the fluorescent probe 2,6-TNS gave rise to the highest increase in fluorescence for BSA. When the composition of these separation buffers was optimized for the electrophoretic separations, CHES buffer, pH 10.2 was chosen as the most suitable buffer to detect bovine whey proteins. The limit of detection obtained for some whey proteins in CE separations was about 6.10(-8) M for BSA, 3.10(-7) M for beta-lactoglobulin A (beta-LGA), 3.10(-7) M for beta-lactoglobulin B (beta-LGB), and 3.10(-6) M for alpha-lactalbumin (alpha-LA). These detection limits were compared to those achieved using UV detection under the same separation conditions. The results showed that the detection limits of BSA, beta-LGA and beta-LGB were twice as good using LIF than with UV detection. However, the limit of detection for alpha-LA was better when UV was used. The applicability of LIF detection to CE separation of whey proteins in bovine milk samples was also demonstrated.  相似文献   

7.
A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO(2)(2-), AsO(4)(2-), and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L(-1) sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl(-), NO(2)(-), NO(3)(-) and SO(4)(2-)) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 micromol L(-1) of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water.  相似文献   

8.
色氨酸及其主要代谢产物的分离和在生物样品中的测定   总被引:4,自引:0,他引:4  
易咏红  廖卫平  赵绮华  陆雪芬 《色谱》1999,17(2):158-161
建立以乙酸缓冲系统和甲醇作流动相、电化学和紫外检测器联用的高效液相色谱法,分离和测定了色氨酸经5-羟色胺和犬尿酸原两条主要代谢途径的8种代谢物。使用三氯乙酸作离子对试剂以延长3-羟犬尿酸原的保留时间,分析了流动相pH值和三氯乙酸浓度对各物质分离的影响及检测条件。结果表明,pH值及三氯乙酸浓度对各物质保留时间有明显影响,可作为控制分离的主要因素。此外,对生物样品中各物质分离和检测条件进行了讨论。  相似文献   

9.
Conductivity detection is applied to ion-exchange capillary electrochromatography (IE-CEC) with a packed stationary phase, using a capacitively coupled contactless conductivity detector with detection occurring through the packed bed. Columns were packed with a polymeric latex-agglomerate anion-exchanger (Dionex AS9-SC). A systematic approach was used to determine suitable eluants for IE-CEC separations using simultaneous indirect UV and direct conductivity detection. Salicylate and p-toluenesulfonate were identified as potential eluant competing anions having sufficient eluotropic strength to induce changes in separation selectivity, but salicylate was found to be unsuitable with regard to baseline stability. It was also found for both indirect UV and direct conductivity detection that homogenous column packing was imperative, and monitoring of the baseline could be used to assess the homogeneity of the packed bed. Using a p-toluenesulfonate eluant, the separation of eight common anions was achieved in 2.5 min. Direct conductivity detection was found to be superior to indirect UV detection with regard to both baseline stability and detection sensitivity with detection limits of 4-25 microg/L being obtained. However, the calibration for each anion was not linear over more than one order of magnitude. When using conductivity detection, the concentration of the eluant could be varied over a wider range (2.5-50 mM p-toluenesulfonate) than was the case with indirect UV detection (2.5-10 mM), thereby allowing greater changes in separation selectivity to be achieved. By varying the concentration of p-toluenesulfonate in the eluant, the separation selectivity could be manipulated from being predominantly ion-exchange in nature (2.5 mM) to predominantly electrophoretic in nature (50 mM).  相似文献   

10.
In this paper, capillary zone electrophoresis with amperometric detection (CZE-AD) was first applied to the simultaneous separation and determination of amitrole and urazole in water samples. A simple end-column electrochemical detector was used in combination with a commercially available capillary electrophoresis instrument with UV detection. The effects of several important factors were investigated to find optimum conditions. A carbon disk electrode was used as working electrode. Separation and determination of these compounds in water samples were performed in 0.030 mol l(-1) acetate buffers at pH 4.5, 25 kV as separation voltage and the samples were introduced by hydrodynamic mode for 1.5 s. Most of the studies realized showed that the direct electrochemical detection is more sensitive and selective than UV detection. Under the optimum conditions, excellent linearity was observed between peak amperometric signal and analyte concentrations in the range of 0.19-1.35 mg l(-1) for amitrole and 0.20-1.62 mg l(-1) for urazole. The detection limits were 63 and 68 microg l(-1) for amitrole and urazole, respectively. The utility of this method was demonstrated by monitoring water samples, and the assay results were satisfactory. The detection limits using a previous preconcentration step for amitrole and urazole in spiked mineral water samples were 0.6 and 1.0 microg l(-1) for amitrole and urazole, respectively.  相似文献   

11.
A capillary electrophoretic method with UV detection for separation and quantitation of perfluorocarboxylic acids (PFCAs) from C6-PFCA to C12-PFCA has been developed. The optimization of measurement conditions included the choice of the most appropriate type and concentration of buffer in the background electrolyte (BGE), as well as the type and the content of an organic modifier. The optimal separation of investigated PFCAs was achieved with 50 mM phosphate buffer and 40% isopropanol in the BGE using direct UV detection. The optimum wavelength for direct UV detection was optimized at 190 nm. For indirect detection, several chromophores were studied. Five mM 3,5-Dinitrobenzoic acid (3,5-DNBA) in 20 mM phosphate buffer BGE and indirect UV detection at 280 nm gave the optimal detection and separation performance for the investigated PFCAs. The possibility of on-line preconcentration of solutes by stacking has been examined for indirect detection. The detection limits (LODs) determined for direct UV detection ranged from 2 microg/mL for C6-PFCA to 33 microg/mL for C12-PFCA. The LODs obtained for indirect UV detection were comparable to those obtained for direct UV detection.  相似文献   

12.
A new capillary electrophoretic (CE) method was developed for the selective and sensitive determination of common metal ions. The proposed method is based on conventional CE separation of metal cations followed by complete complexation of separated analytes with 1,10-phenanthroline using the zone-passing technique. This approach combines both partial and complete complexation modes and, thus, enables rapid, selective, efficient separation together with sensitive direct UV detection of metal species. The optimal conditions for the separation and derivatization reaction were established by varying type of electrolyte, electrolyte pH, introduction time and concentration of 1,10-phenanthroline. The optimized separations were carried out in 50 mmol l(-1) glycolic acid electrolyte (pH 6.0 with imidazole) using direct UV detection at 254 nm. Five common metal cations (Fe2+, Co2+, Ni2+, Cu2+ and Zn2+) were separated in less than 4 min. The proposed system was applied to the determination of Fe(II) and Zn(II) in snow samples. The recovery tests established for snow samples were within the range 100+/-12%.  相似文献   

13.
A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg2+, Ca2+, and Sr2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV‐absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg2+, Ca2+, and Sr2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg2+, Ca2+, and Sr2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S /N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded.  相似文献   

14.
邱月  李根容  龙梅  李沿飞  夏之宁 《色谱》2019,37(9):990-995
建立了一种同时检测塑料食品接触材料中13种紫外吸收剂的超高效合相色谱法。以甲醇为溶剂对塑料食品接触材料样品进行超声提取,经C18固相萃取柱净化,过0.22 μm有机滤膜,采用超高效合相色谱仪分析。选择ACQUTY UPC2 HSS C18 SB色谱柱(150 mm×3.0 mm,1.8 μm),以超临界二氧化碳为流动相,异丙醇为改性剂进行梯度洗脱,在最优色谱条件下,13种紫外吸收剂能够在4 min内实现有效分离。结果表明,在各自线性范围内,13种紫外吸收剂的线性关系良好,标准曲线相关系数不低于0.9985,检出限(S/N=3)为0.05~0.15 mg/kg,加标回收率为86.8%~115.7%,相对标准偏差为0.73%~5.61%。该方法快速简便,准确可靠,同时大大减少了有机溶剂的消耗,可用于塑料食品接触材料中13种紫外吸收剂的快速检测。  相似文献   

15.
A rapid, sensitive and accurate high performance liquid chromatography with UV detection method was developed and validated for the quantification of gabapentin in dosage forms. Gabapentin was quantified after pre-column derivatization with 1-fluoro-2,4-dinitrobenzene. Amlodipine was used as an internal standard. The chromatographic separation was carried out on a Nova-Pak C(18) column using a mixture of acetonitrile-sodium dihydrogenphosphate (pH 2.5; 0.05 M) (70:30, v/v) as mobile phase with UV detection at 360 nm. The method was linear over the range of 10-500 microg/ml of gabapentin (r(2)>0.999). The within-day and between-day precision values were in the range of 0.86-1.11%. The method was successfully used for quantitative determination and dissolution rate study of Neurontin capsules.  相似文献   

16.
On-column complexation of Fe2+ and Fe3+ with 2,6-pyridinedicarboxylic acid (2,6-PDCA) formed anionic complexes, which were then separated by capillary zone electrophoresis with direct UV detection at 214 nm. To achieve reasonable separation selectivity and on-column complexation, the conditions such as pH, the concentration of 2,6-PCDA and the EOF modifiers in the electrolyte were examined. The electrolyte contained 5.0 mM 2,6-PDCA, 0.25 mM tetradecyltrimethlammonium bromide (TTAB) and 5% (v/v) acetonitrile at pH 4.0 was optimised for on-column complexation and the separation of Fe[PCDA]2(2-) and Fe[PCDA]2(-). To enhance the detection sensitivity, large-volume sample stacking (LVSS) was used for the on-line preconcentration of Fe[PCDA]2(2-) and Fe[PCDA]2(-). Under the optimised conditions, satisfactory working ranges (0.5-50 microM), lower detection limits (less than 0.1 microM) and good repeatability of the peak areas (R.S.D.: 5.2-7.8%, n = 5) was achieved using LVSS (300 s). With LVSS, the detection sensitivity was enhanced more than 50-fold compared to conventional hydrodynamic injection. The proposed method was used successfully for the determination of Fe2+ and Fe3+ in water samples.  相似文献   

17.
A simple and reliable precolumn derivatization liquid chromatography method with ultraviolet detection has been developed and validated for the analysis of glucosamine (GS) in various dietary supplement formulations and raw materials. Additionally, the proposed method was used for analysis of carisoprodol (CR) found in ternary mixture with paracetamol (PR) and caffeine (CF). The linearity ranges were 1-100 μg/mL for GS, 1-150 μg/mL for CR, PR and CF. Derivatization was used with 1,2-naphthoquinone-4-sulphonic acid sodium salt in the presence of borate buffer. Chromatographic separation of GS-naphthoquinone derivative was achieved by using a mixture of acetonitrile and water (pH 7.3 adjusted with 0.1 M NaOH) in the ratio 10:90, v/v and flow-rate of 1.0 mL/min. UV detection was carried out at 280 nm. For PR, CF, and CR-naphthoquinone derivative, the chromatographic separation was achieved by using mixture of acetonitrile and 20 mM KH(2)PO(4) (pH 3.0 adjusted with phosphoric acid) in the ratio 20:80, v/v and flow-rate of 1.0 mL/min. UV detection was carried out at 275 nm. The limits of detection were 37.2, 35.9, 30.4 and 40.0 ng/mL for GS, CR, PR and CF, respectively.  相似文献   

18.
The cation-induced or electrochemical oxidation of flavonols has been reported to yield 2-(hydroxybenzoyl)-2-hydroxy-3(2H)-benzofuranone. Two new gradient reversed phase HPLC methods are presented which allow the determination of those oxidized flavonols simultaneously with flavonols and flavones. UV and electrochemical detection are used because of their high sensitivity. Qualitative detection together with quantification of all compounds is achieved with photodiode-array detection. An electrospray ionization ion trap mass spectrometric method is presented for unique identification of the benzofuranones after HPLC separation.  相似文献   

19.
Separation and detection of lanthanides by capillary zone electrophoresis in the presence of cupferron (N-nitroso-N-phenylhydroxylamine) as UV absorbing complexing agent were investigated. The resolution of partially complexed positively charged cupferron complexes is improved by using a buffer ligand competing with cupferron for metal ions. When hydroxyisobutyric acid (HIBA) is used as buffer and competing ligand, it provides complete separation of all 14 lanthanides with good peak shapes. An on-column separation of 14 lanthanides was achieved in only 7 min using 0.1 mmol/l cupferron, 15 mmol/1 HIBA at pH 4.9. The separation efficiencies for the optimum separation condition are between 77,000 and 208,000 theoretical plates. Determination of lanthanide complexes was performed by direct UV detection at 210 nm. Detection limits (signal-to-noise ratio=3) are ca. 0.24-0.47 microg/ml for lanthanides. Under optimum conditions, the complete separation of thorium and uranium from mixed lanthanides was achieved.  相似文献   

20.
A high-performance liquid chromatography method is described here for the determination of the Cd(II), Co(II), Cu(II), Pb(II), and Zn(II) complexes of ethylenediaminetetraacetate (EDTA) in municipal wastewaters and surface waters. The method involves separation by ion-exchange chromatography on a reversed-phase C18 column coated with ion-pair reagent, followed by post-column conversion to FeEDTA and subsequent detection by UV absorbance. Although Co(II) and Cu(II) coelute, they can be quantified by analyzing absorbance by CuEDTA2- prior to post-column conversion. The method detection limit of 6-8 x 10(-8) M (5-7 ng) is an order of magnitude improvement over previous UV absorbance post-column reaction methods. The technique can be used in the presence of organic matter encountered in matrices such as untreated wastewater without pre-concentration or sample cleanup.  相似文献   