首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In the present study, a rapid, highly efficient and environmentally friendly sample preparation method named temperature-controlled ionic liquid dispersive liquid-phase microextraction (TC-IL-DLPME), followed by high performance liquid chromatography (HPLC) was developed for the extraction, preconcentration and determination of four benzophenone-type ultraviolet (UV) filters (viz. benzophenone (BP), 2-hydroxy-4-methoxybenzophenone (BP-3), ethylhexyl salicylate (EHS) and homosalate (HMS)) from water samples. An ultra-hydrophobic ionic liquid (IL) 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([HMIM][FAP]), was used as the extraction solvent in TC-IL-DLPME. Temperature served two functions here, the promotion of the dispersal of the IL to the aqueous sample solution to form infinitesimal IL drops and increase the interface between them and the target analytes (at high temperature), and the facilitation of mass transfer between the phases, and achievement of phase separation (at low temperature). Due to the ultra-hydrophobic feature and high density of the extraction solvent, complete phase separation could be effected by centrifugation. Moreover, no disperser solvent was required. Another prominent feature of the procedure was the combination of extraction and centrifugation in a single step, which not only greatly reduced the total analysis time for TC-IL-DLPME but also simplified the sample preparation procedure. Various parameters that affected the extraction efficiency (such as type and volume of extraction solvent, temperature, salt addition, extraction time and pH) were evaluated. Under optimal conditions, the proposed method provided good enrichment factors in the range of 240–350, and relative standard deviations (n = 5) below 6.3%. The limits of detection were in the range of 0.2–5.0 ng/mL, depending on the analytes. The linearities were between 1 and 500 ng/mL for BP, 5 and 1000 ng/mL for BP-3, 10 and 1000 ng/mL for HMS and 5 and 1000 ng/mL for EHS. Finally, the proposed method was successfully applied to the determination of UV filters in swimming pool and tap water samples and acceptable relative recoveries over the range of 88.0–116.0% were obtained.  相似文献   

2.
Temperature-controlled ionic liquid dispersive liquid phase microextraction (TCIL-DLPME) combined with high performance liquid chromatography-diode array detection (HPLC-DAD) was applied for preconcentration and determination of chlorobenzenes in well water samples. The proposed method used 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) as the extraction solvent. The effect of different variables on extraction efficiency was studied simultaneously using an experimental design. The variables of interest in the TCIL-DLPME were extraction solvent volume, salt effect, solution temperature, extraction time, centrifugation time, and heating time. The Plackett-Burman design was employed for screening to determine the variables significantly affecting the extraction efficiency. Then, the significant factors were optimized by using a central composite design (CCD) and the response surface equations were developed. The optimal experimental conditions obtained from this statistical evaluation included: extraction solvent volume, 75 μL; extraction time, 20 min; centrifugation time, 25 min; heating time, 4 min; solution temperature, 50 °C; and no addition of salt. Under optimal conditions, the preconcentration factors were between 187 and 298. The limit of detections (LODs) ranged from 0.05 μg L−1 (for 1,2-dichlorobenzene) to 0.1 μg L−1 (for 1,2,3-trichlorobenzene). Linear dynamic ranges (LDRs) of 0.5-300 and 0.5-500 μg L−1 were obtained for dichloro- and trichlorobenzenes, respectively. The performance of the method was evaluated for extraction and determination of chlorobenzenes in well water samples in micrograms per liter and satisfactory results were obtained (RSDs < 9.2%).  相似文献   

3.
In this article, a novel method termed as temperature-assisted ionic liquid dispersive liquid-liquid microextraction (TA IL-DLLME) combining high performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of anthraquinones in Radix et Rhizoma Rhei samples. The ionic liquid (1-hexyl-3-methylimidazolium hexafluorophosphate) was used to replace volatile organic solvent as an extraction solvent for the extraction of anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) from Radix et Rhizoma Rhei. Several important parameters influencing the extraction efficiency of TA IL-DLLME such as the type and volume of extraction solvent and disperser solvent, sample pH, extraction time, extraction temperature, centrifugation time as well as salting-out effects were optimized. Under the optimal conditions, the spiked recovery for each analyte was in the range of 95.2-108.5%. The precisions of the proposed method were varied from 1.1% to 4.4% (RSD). All the analytes exhibited good linearity with correlation coefficients (r2) ranging from 0.9986 to 0.9996. The limits of detection for all target analytes were ranged from 0.50 to 2.02 μg L−1 (S/N = 3). The experimental results indicated that the proposed method was successfully applied to the analysis of anthraquinones in Radix et Rhizoma Rhei.  相似文献   

4.
Ultrasound-assisted ionic liquid dispersive liquid-phase micro-extraction was developed for the determination of four aromatic amines such as 2,4-dichloroaniline, 1-naphthylamine, 6-chloroanline and N,N-dimethylaniline. High-performance liquid chromatography coupled with UV detector was used for the determination of aromatic amines. In the novel procedure, 1-hexyl-3-methylimidazolium hexafluorophosphate [C6MIM] [PF6] was dispersed into the aqueous sample solution as fine droplets by ultrasonication, and which promoted the analytes more easily migrate into the ionic liquid phase. Variable affecting such as the volume of [C6MIM] [PF6], sample pH, ultrasonication time, extraction time, centrifuging time have been investigated in detail. The proposed method has been found to have excellent detection sensitivity with limits of detection (LOD, S/N = 3) in the range of 0.17–0.49 μg L−1 and precisions in the range of 2.0–6.1% (RSDs, n = 6). This method has been also successfully applied to analyze the real water samples and good spiked recoveries over the range of 92.2–119.3% were obtained.  相似文献   

5.
吴翠琴  雷金妹  李韵灵  王韵靓  陈迪云  龚剑 《色谱》2014,32(12):1362-1367
建立了一种基于离子液体的分散液液微萃取技术结合柱前荧光衍生高效液相色谱(IL-DLLME-HPLC-FL)对8种磺胺类药物进行检测的方法,并成功应用于实际环境水样的分析。实验考察了萃取参数对磺胺萃取效率的影响及衍生产物的稳定性。最佳实验条件:以40 μL [C6MIM]PF6]为萃取剂,0.1 mL丙酮为分散剂,对pH=4且不含NaCl的水溶液进行不超声的分散液液微萃取,并衍生化反应6 h。结果表明:在最佳实验条件下,该法在0.2~10 μg/L和10~500 μg/L两个浓度范围内线性良好,线性相关系数r ≥0.9989;检出限为0.08~0.5 μg/L (S/N=3)。对实验室自来水、湖水、珠江水、池塘水分别加标5、50、200 μg/L的回收率为87.2%~101.4%,相对标准偏差为3.7%~6.2%。该法环保、简便,可用于测定实际水样中磺胺类药物。  相似文献   

6.
A new method for the determination of four sulfonylurea herbicides (metsulfuron-methyl, chlorsulfuron, bensulfuron-methyl and chlorimuron-ethyl) in water samples was developed by dispersive liquid–liquid microextraction coupled with high performance liquid chromatography-diode array detector. Parameters that affect the extraction efficiency, such as the kind and volume of the extraction and disperser solvent, extraction time and salt addition, were investigated and optimised. Under the optimum conditions, the enrichment factors were in the range between 102 and 216. The linearity of the method was obtained in the range of 1.0–100 ng mL?1 with the correlation coefficients (r) ranging from 0.9982 to 0.9995. The method detection limits were 0.2–0.3 ng mL?1. The proposed method has been successfully applied to the analysis of target sulfonylurea herbicides in river, stream and well water samples with satisfactory results.  相似文献   

7.
A novel method, termed ionic liquid cold-induced aggregation dispersive liquid–liquid microextraction (IL-CIA-DLLME), combined with high-performance liquid chromatography (HPLC) was developed for the determination of three phthalate esters in water samples. Several important parameters influencing the IL-CIA-DLLME extraction efficiency, such as the type of extraction and disperser solvent, the volume of extraction and disperser solvent, temperature, extraction time and salt effect, were investigated. Under optimal extraction conditions, the enrichment factors and extraction recoveries ranged from 174 to 212 and 69.9 to 84.8%, respectively. Excellent linearity with coefficients of correlation from 0.9968 to 0.9994 was observed in the concentration range of 2–100 ng mL−1. The repeatability of the proposed method expressed as relative standard deviations ranged from 2.2 to 3.7% (n = 5). Limits of detection were between 0.68 and 1.36 ng mL−1. Good relative recoveries for phthalate esters in tap, bottled mineral and river water samples were obtained in the ranges of 91.5–98.1%, 92.4–99.2% and 90.1–96.8%, respectively. Thus, the proposed method has excellent potential for the determination of phthalate esters in the environmental field.  相似文献   

8.
A new method, which involves liquid-phase microextraction (LPME) followed by high performance liquid chromatography (HPLC) with diode array detector (DAD), was developed to determine phoxim in water sample. Experimental parameters affecting the extraction efficiency, such as extraction solvent, solvent volume, agitation speed of the sample and extraction time were investigated. Under the optimal extraction conditions, phoxim was found to yield a good linear calibration curve in the concentration range from 0.01 to 5 μg mL−1. The limit of detection (LOD) is 10 ng mL−1, and relative standard deviation (RSD) at the 100 ng mL−1 levels is 8.4%. Lake water and tap water samples were successfully analyzed using the proposed method.  相似文献   

9.
建立了基于1-辛基-3-甲基咪唑六氟磷酸盐离子液体的单滴液相微萃取-高效液相色谱测定水中的杀螨隆农药残留的新方法.考察了萃取剂种类、萃取剂体积、液滴大小、萃取时间、搅拌速度、温度、盐度等对萃取效率的影响.在最佳条件下,该方法的线性范围为0.05~5 mg/L,r2=0.9994,RSD为2.1%(n=6),检出限为0....  相似文献   

10.
In this article, a novel and simple microextraction method, termed ionic liquid/ionic liquid dispersive liquid–liquid microextraction (IL/IL‐DLLME), has been designed and developed for the rapid enrichment and analysis of environmental pollutants. Instead of using hazardous organic solvents, two kinds of ILs, hydrophobic IL and hydrophilic IL, were used as extraction solvent and disperser solvent in IL/IL‐DLLME step, respectively. Permethrin and biphenthrin, two of the often‐used pyrethroid pesticides, were used as model compounds. Factors that may affect the enrichment efficiencies were investigated and optimized in detail. Under optimum conditions, permethrin and biphenthrin exhibited a wide linear relationship over the range 1–100 μg/L. For permethrin and biphenthrin, the precisions were 4.65–7.78%, and limits of detection were found to be 0.28 and 0.83 μg/L, respectively. Satisfactory results were achieved when the present method was applied to analyze the target compounds in real‐world water samples with spiked recoveries over the range 84.1–113.5%. All these facts indicated that IL/IL‐DLLME is a simple and rapid alternative for the enrichment and analysis of environmental pollutants and will have a wide application perspective in the future.  相似文献   

11.
Dichlorodiphenyltrichloroethane (DDT) and its main metabolites are important environmental pollutants and have been in the focusing center. It is of great value to develop simple, rapid, sensitive and easy to operate method for monitoring them. Present work established a novel temperature controlled ionic liquid dispersive liquid phase microextraction method in combination with high performance liquid chromatography for the enrichment and determination of DDT and its metabolites. Proposed method used only ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) for the enrichment and overcame the demerits of conventional single drop liquid phase microextraction and dispersive liquid-liquid microextraction. Temperature has two functions here, one is to promote the dispersing of ionic liquid into the solution and forming infinitesimal micro-drop and increasing the chance of the analytes extracted into ionic liquid phase, and the other one is to perform phase-separation. A series of factors that would affect the extraction performance was systematically investigated and optimized. The experimental results indicated that the detection limits obtained for p,p′-DDD, p,p′-DDT, o,p′-DDT and p,p′-DDE were 0.24, 0.24, 0.45, 0.24 ng mL−1, respectively. The linear ranges for them were from 1.0 to 100 ng mL−1, and the precisions were between 3.8% and 6.7% (n = 6). The proposed method was validated with four real-world samples and excellent results were achieved.  相似文献   

12.
A novel microextraction method, termed microwave‐assisted ionic liquid/ionic liquid dispersive liquid–liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high‐performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1‐hexyl‐3‐methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1‐hexyl‐3‐methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1‐butyl‐3‐methylimidazolium tetrafluoroborate. In addition, an ion‐pairing agent (NH4PF6) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00–250.00 μg/L, with the correlation coefficients of 0.9982–0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7–105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples.  相似文献   

13.
An efficient in situ ionic liquid dispersive liquid–liquid microextraction followed by ultra‐performance liquid chromatography was developed to determine four neonicotinoid insecticides in wild and commercial honey samples. In this method, a hydrophobic ionic liquid 1‐butyl‐3‐methylimidazolium hexafluorophosphate, formed by in situ reaction between potassium hexafluorophosphate and 1‐butyl‐3‐methylimidazolium bromide in sample solution, was used as the extraction solvent. In comparison with the traditional dispersive liquid–liquid microextraction method, the developed method required no dispersive solvent. To achieve high extraction efficiency and enrichment factor, the effects of various experimental parameters were studied in detail. Under the optimized conditions, the limits of detection and quantification were in the ranges of 0.30–0.62 and 1.20–2.50 μg/L, respectively. The method showed high enrichment factors (74–115) with the recoveries between 81.0 and 103.4%. The proposed method was finally applied to different wild and commercial honey samples.  相似文献   

14.
Graphene is a novel and interesting carbon material that could be used for the separation and purification of some chemical compounds. In this investigation, graphene was used as a novel fiber‐coating material for the solid‐phase microextraction (SPME) of four triazine herbicides (atrazine, prometon, ametryn and prometryn) in water samples. The main parameters that affect the extraction and desorption efficiencies, such as the extraction time, stirring rate, salt addition, desorption solvent and desorption time, were investigated and optimized. The optimized SPME by graphene‐coated fiber coupled with high‐performance liquid chromatography‐diode array detection (HPLC‐DAD) was successfully applied for the determination of the four triazine herbicides in water samples. The linearity of the method was in the range from 0.5 to 200 ng/mL, with the correlation coefficients (r) ranging from 0.9989 to 0.9998. The limits of detection of the method were 0.05‐0.2 ng/mL. The relative standard deviations varied from 3.5 to 4.9% (n=5). The recoveries of the triazine herbicides from water samples at spiking levels of 20.0 and 50.0 ng/mL were in the range between 86.0 and 94.6%. Compared with two commercial fibers (CW/TPR, 50 μm; PDMS/DVB, 60 μm), the graphene‐coated fiber showed higher extraction efficiency.  相似文献   

15.
张丽媛  姚笛  李娜  张寒琦  于爱民 《色谱》2015,33(7):753-758
建立了婴儿配方奶粉中三嗪类除草剂的均相液液微萃取-高效液相色谱分析方法。以离子液体为液液微萃取溶剂,Eclipse XDB-C18为色谱柱,乙腈和水为流动相梯度洗脱分离。详细研究了液液微萃取条件对实验结果的影响。在最优实验条件下,三嗪类除草剂的标准曲线呈良好的线性(r≥0.9992),草净津、敌草净、特丁通、特丁津和异戊乙净的检出限分别是12.1、13.8、11.8、14.6和13.7 μg/kg;婴儿配方奶粉中的加标回收率为92.2%~103.2%,相对标准偏差低于6%。该方法灵敏度高、操作简单,适用于奶粉样品中三嗪类除草剂残留的检测。  相似文献   

16.
A simple, rapid, efficient, and environmentally friendly method for the determination of some triazine herbicides (simazine, atrazine, prometone, ametryn and prometryne) in water samples was developed by ultrasound-assisted emulsification microextraction (USAEME) coupled with high-performance liquid chromatography-diode array detection (HPLC-DAD). The main parameters that affect the extraction efficiencies, such as the kind and volume of the extraction solvent, ultrasound emulsification time and salt addition, were investigated and optimized. Under the optimum conditions, the method was sensitive and showed a good linearity within a range of 0.5 to 200?ngm?L?1 for simazine, atrazine, prometone, ametryn and prometryne, with the correlation coefficients (r) varying from 0.9993 to 0.9998. High enrichment factors were obtained ranging from 148 to 225. The limits of detection (LODs) were in the range between 0.06 and 0.1?ngm?L?1 and the limits of quantification (LOQs) were in the range between 0.2 and 0.3?ngm?L?1. The recoveries of the analytes from water samples at spiking levels of 5.0 and 50.0?ngm?L?1 were ranged from 82.4% to 107.0%. The relative standard deviations (RSDs) varied from 3.0% to 4.6%. The results demonstrated that the USAEME-HPLC-DAD method was an ef?cient pretreatment and enrichment procedure for the determination of triazine pesticides in real water samples.  相似文献   

17.
Zhang J  Gao H  Peng B  Li S  Zhou Z 《Journal of chromatography. A》2011,1218(38):6621-6629
This research paper presents a comparative study of the performance of conventional, ultrasound-assisted (UA), and temperature-controlled (TC) ionic liquid (IL) dispersive liquid-phase microextraction (IL-DLLME). Various parameters that affect extraction efficiency, such as type and volume of extraction and disperser solvent, centrifugation time, salt addition, effect of temperature on TC-IL-DLLME, and effect of sonication time on UA-IL-DLLME, were evaluated. UA-IL-DLLME was found to provide the best extraction efficiency. Under optimized conditions, great enrichment factors (506-515) and good recoveries (101.2-103.0%) were obtained by analyte extraction in real samples. The limit of detections (LODs) ranged from 0.21 to 0.38 μg L(-1). Good linearity was obtained in the range of 0.5-200 μg L(-1) for ethofenprox and tetramethrin, and 1-200 μg L(-1) for meperfluthrin and alpha-cypermethrin. Based on optimized conditions, the UA-IL-DLLME method was applied and combined with high-performance liquid chromatography with diode array detection (HPLC-DAD) to determine the presence of ethofenprox, tetramethrin, meperfluthrin, and alpha-cypermethrin in honey samples.  相似文献   

18.
A simple and efficient method, ionic liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV), has been applied for the extraction and determination of some antioxidants (Irganox 1010, Irganox 1076 and Irgafos 168) in water samples. The microextraction efficiency factors were investigated and optimized: 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)MIM][PF(6)] (0.06 g) as extracting solvent, methanol (0.5 mL) as disperser solvent without salt addition. Under the selected conditions, enrichment factors up to 48-fold, limits of detection (LODs) of 5.0-10.0 ng/mL and dynamic linear ranges of 25-1500 ng/mL were obtained. A reasonable repeatability (RSD≤11.8%, n=5) with satisfactory linearity (r(2)≥0.9954) of the results illustrated a good performance of the presented method. The accuracy of the method was tested by the relative recovery experiments on spiked samples, with results ranging from 85 to 118%. Finally, the method was successfully applied for determination of the analytes in several real water samples.  相似文献   

19.
Huang SD  Huang HI  Sung YH 《Talanta》2004,64(4):887-893
Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) for the determination of triazine is described. Carbowax/templated resin (CW/TPR, 50 μm), polydimethylsiloxane/divinylbenzene (PDMS/DVB, 60 μm), polydimethylsiloxane (PDMS, 100 μm), and polyacrylate (PA, 85 μm) fibers were evaluated for extraction of the triazines. CW/TPR and PDMS/DVB fibers were selected for further study. Several parameters of the extraction and desorption procedure were studied and optimized (such as types of fibers, desorption mode, desorption time, compositions of solvent for desorption, soaking periods and the flow rate during desorption period, extraction time, temperature, pH, and ionic strength of samples). Both CW/TPR and PDMS/DVB fibers are acceptable; a simple calibration-curve method based on simple aqueous standards can be used. The linearity of this method for analyzing standard solution has been investigated over the range 5-1000 ng mL−1 for both PDMS/DVB and CW/TPR fibers. All the correlation coefficients in the range 5-1000 ng mL−1 were better than 0.995 except Simazine and Atratone by CW/TPR fiber. The R.S.D.s range from 4.4% to 8.8 % (PDMS/DVB fiber) and from 2.4% to 7.2% (CW/TPR fiber). Method-detection limits (MDL) are in the range 1.2-2.6 and 2.8-3.4 ng mL−1 for the two fibers. These methods were applied to the determination of trazines in environmental water samples (lake water).  相似文献   

20.
In the current paper we describe a novel sample preparation technique termed dispersive liquid-phase microextraction for the preconcentration and determination of 2,2,2-trichloro-1,1-bis(4-chlorophenyl)ethanol (dicofol) and its degradation products in water samples that includes 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethene(2,4′-DDE), 1,1-dichloro-2,2-bis(4-chlorophenyl)ethane(4,4′-DDE) and 1,1,1-trichloro-2-(2-chlorophenyl)-2-(4-chlorophenyl)ethane (2,4′-DDT) coupled with gas chromatography mass spectrometry (GC-MS), in which a new ionic liquid 1,3-diisooctylimidazolium hexafluorophosphate abbreviated as [D(i-C8)IM][PF6] was used as extraction solvent. For each one extraction, 1.00 mL of the methanol solution containing 40 µL of the ionic liquid was sprayed into 25.00 mL of water sample. In the meantime the ionic liquid was finely dispersed into the aqueous phase and analytes were rapidly migrated into the ionic liquid. After the solution was centrifuged for 2 min at 5000 rpm, the droplets of the ionic liquid are subsided in the bottom of the conical test tube (30.0 ± 0.2 µL). Moreover, the factors relevant to extraction efficiencies were investigated and optimised including the volume of the ionic liquid, disperser solvent, extraction time, sample pH and ionic strength. Under optimal conditions, the enrichment factors of the extraction were between 550 and 725 with an extraction efficiency ranging from 66% to 87% for each different analyte. Finally, 1.0 µL of the ionic liquid collected from above extraction was injected into the injector block of GC-MS instrument for analysis. The detection limit (S/N = 3), the relative standard deviations for 2.0 µg L?1 of the standard analyte (n = 5) and linearity in a calibration range were found to be 3–8 ng L?1, 1.0–2.7% and 10–3000 ng L?1, respectively. Good spiked recoveries over the range of 92.0–13.5% were obtained. The proposed method offers the advantages of simplicity of operation, rapidity, good extraction efficiency and enrichment factor; it has been successfully applied to determination of dicofol and its degradation products in environmental water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号