首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
毛细管电泳与化学发光检测联用方法的研究进展   总被引:1,自引:0,他引:1  
易方  黄香宜  任吉存 《色谱》2017,35(1):110-120
毛细管电泳由于其超高的分离效率广泛应用于生物医药、环境监测、食品科学以及公共安全等领域。然而,由于毛细管电泳具有进样量较少、检测光程较短等缺点,需要与高灵敏度检测器联用实现低浓度样品的分析。化学发光检测由于其背景信号低而具有超高的灵敏度。毛细管电泳-化学发光检测联用方法将毛细管电泳的高效分离特性与化学发光检测的高灵敏性相结合,成为一种非常重要的分析方法,广泛用于化学分析、药物筛选以及环境监测等领域。该文对近年来毛细管电泳-化学发光检测联用方法的基本原理进行概述,并对其发展趋势和应用前景进行了展望。  相似文献   

2.
A strategy on amperometric detection for CZE of phenol carbamates as model analytes with a facile in‐line thermal hydrolysis was presented, in which a thermal hydrolysis, subsequent CZE separation and final column‐end amperometric detection were accomplished in an intact capillary. Key parameters of hydrolysis dynamics of carbamates and electrochemical detection of the hydrolysates were studied, as well as electrophoretic conditions. Under the optimal conditions, the capillary was utilized as chambers for in situ hydrolysis, CZE separation, and electrochemical detection. The successive separation of hydrolysates of five carbamates (propoxur, carbofuran, 3‐OH‐carbofuran, carbaryl and bendiocarb) were achieved within 17 min. Applied to vegetable samples, the recoveries of carbamates fortified at 0.02 and 0.05 mg/kg were ranging in 88–107.2 and 86.3–107.3%, respectively. The success in the implementation of such a scheme resulted in a simple instrument as compared with those current analytical methods with post‐column derivization or pre‐column hydrolysis, or online enrichment in chip, respectively. This protocol might possess a potential utility for the sensitive amperometric detection of phenol carbamates.  相似文献   

3.
王荣  周敏  王苏霞  廖原  樊雪  马永钧 《色谱》2020,38(8):968-974
将氨甲环酸进行N-甲基化衍生反应后,其衍生产物能与联吡啶钌电致化学发光试剂产生强的共发光信号,据此建立了毛细管电泳-电致化学发光法高选择性测定日用化妆品试样中氨甲环酸含量的新方法。实验中发现,添加一种Mg2+-海藻糖-SiO2-3三元缔合物凝胶至背景电解液中,可极大地改善电泳分离效能。在优化的分析条件下,氨甲环酸和内标物肌氨酸衍生产物的电泳峰可在500 s内达到完全分离,且此两个电泳峰的强度比值与氨甲环酸的初始浓度在10~750μmol/L的范围内呈良好的线性关系(相关系数r2=0.999 3),检出限为3.6μmol/L(S/N=3)。采用内标法对3种市售牙膏膏体和2种面膜护理液中的氨甲环酸进行了定量测定,测得这些试样中氨甲环酸含量的均值分别为4.05、0.24、6.06 mg/g和51.3、7.98 mg/mL,加标回收率在92.5%~104.0%内,结果令人满意。  相似文献   

4.
A high‐speed DNA fragment separation system based on an on‐line combination of capillary ITP with CZE (CITP‐CZE) and using UV detection at 260 nm was developed. A novel CITP‐CZE buffer system of pH 6.1 was designed for the separation of ten DNA fragments with sizes ranging from 100 to 1000 bp. An effect of underivatized α‐, β‐ and γ‐cyclodextrins on the resolution of DNA fragments in the CZE step of the CITP‐CZE combination was systematically investigated. Methylhydroxyethylcellulose present in the BGE was used to eliminate the EOF. DNA ladder fragments were separated within 10 min with LODs in the range of 1–5 ng/μL (S/N = 3). The RSDs of the migration time and peak area of individual DNA fragments were in the range of 1–3 and 3–9%, respectively. The developed CITP‐CZE system was further applied to the analysis of digest plasmid DNA samples.  相似文献   

5.
A coaxial flow‐gating interface is described in which the separation capillary passes through the sampling capillary. Continuous flow of the sample solution flowing out of the sampling capillary is directed away from the injection end of the separation capillary by counter‐current flow of the gating solution. During the injection, the flow of the gating solution is interrupted, so that a plug of solution is formed at the inlet into the separation capillary, from which the sample is hydrodynamically injected. Flow‐gating interfaces are originally designed for on‐line connection of capillary electrophoresis with analytical flow‐through methods. The basic properties of the described coaxial flow‐gating interface were obtained in a simplified arrangement in which a syringe pump with sample solution has substituted analytical flow‐through method. Under the optimized conditions, the properties of the tested interface were determined by separation of K+, Ba2+, Na+, Mg2+ and Li+ ions in aqueous solution at equimolar concentrations of 50 μM. The repeatability of the migration times and peak areas evaluated for K+, Ba2+ and Li+ ions and expressed as relative standard deviation did not exceed 1.4%. The interface was used to determine lithium in mineral water and taurine in an energy drink.  相似文献   

6.
7.
毛细管电泳多道电化学检测工作站   总被引:2,自引:0,他引:2  
设计的毛细管电泳多通道电化学检测系统是一个可供在同一个检测环境下,用多台电化学检测器循环对物质进行测定的工作站。工作站采用计算机控制,利用电导和伏安检测器对样品同时进行电导、氧化和还原检测,并实时对数据进行采集,处理,以图形方式显示。  相似文献   

8.
A rapid and simple method using capillary electrophoresis (CE) with chemiluminescence (CL) detection was developed for the determination of levodopa. This method was based on enhance effect of levodopa on the CL reaction between luminol and potassium hexacyanoferrate(III) (K3[Fe(CN)6]) in alkaline aqueous solution. CL detection employed a lab-built reaction flow cell and a photon counter. The optimized conditions for the CL detection were 1.0 × 10−5 M luminol added to the CE running buffer and 5.0 × 10−5 M K3[Fe(CN)6] in 0.6 M NaOH solution introduced postcolumn. Under the optimal conditions, a linear range from 5.0 × 10−8 to 2.5 × 10−6 M (r = 9991), and a detection limit of 2.0 × 10−8 M (signal/noise = 3) for levodopa were achieved. The precision (R.S.D.) on peak area (at 5.0 × 10−7 M of levodopa, n = 11) was 4.1%. The applicability of the method for the analysis of pharmaceutical and human plasma samples was examined.  相似文献   

9.
Indirect detection of paracetamol was accomplished using a capillary electrophoresis-chemiluminescence (CE-CL) detection system, which was based on its inhibitory effect on a luminol-potassium hexacyanoferrate(III) (K3[Fe(CN)6]) CL reaction. Paracetamol migrated in the separation capillary, where it mixed with luminol included in the running buffer. The separation capillary outlet was inserted into the reaction capillary to reach the detection window. A four-way plexiglass joint held the separation capillary and the reaction capillary in place. K3[Fe(CN)6] solution was siphoned into a tee and flowed down to the detection window. CL was observed at the tip of the separation capillary outlet. The CL reaction of K3[Fe(CN)6] oxidized luminol was employed to provide the high and constant background. Since paracetamol inhibits the CL reaction, an inverted paracetamol peak can be detected, and the degree of CL suppression is proportional to the paracetamol concentration. Maximum CL signal was observed with an electrophoretic buffer of 30 mM sodium borate (pH 9.4) containing 0.5 mM luminol and an oxidizer solution of 0.8 mM K3[Fe(CN)6] in 100 mM NaOH solution. Under the optimal conditions, a linear range from 6.6 × 10−10 to 6.6 × 10−8 M (r = 0.9999), and a detection limit of 5.6 × 10−10 M (signal-to-noise ratio = 3) for paracetamol were achieved. The relative standard deviation (R.S.D.) of the peak area for 5.0 × 10−9 M of paracetamol (n = 11) was 2.9%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

10.
Dual detection concepts (DDCs) are becoming more and more popular in analytical chemistry. In this work, we describe a novel DDC for capillary electrophoresis (CE) consisting of an amperometric detector (AD) and a mass spectrometer (MS). This detector combination has a good complementarity as the AD exhibits high sensitivity, whereas the MS provides excellent selectivity. Both detectors are based on a destructive detection principle, making a serial detector arrangement impossible. Thus, for the realization of the DDC, the CE flow was divided into two parts with a flow splitter. The DDC was characterized in a proof-of-concept study with ferrocene derivates and a nonaqueous background electrolyte. We could show that splitting the CE flow was a suitable method for the instrumental realization of the DDC consisting of two destructive detectors. By lowering the height of the AD compared to the MS, it was possible to synchronize the detector responses. Additionally, for the chosen model system, we confirmed that the AD was much more reproducible and had lower limits of detection (LODs) than the MS. The LODs were identical for the DDC and the single-detection arrangements, indicating no sensitivity decrease due to the CE flow splitting. The DDC was successfully applied to determine the drug and doping agent trimetazidine.  相似文献   

11.
赵新颖  屈锋  王勇  王晓倩 《色谱》2014,32(1):1-6
本文为2013年毛细管电泳(CE)技术的年度回顾。介绍了2013年涉及CE技术的国际会议6个,国内会议2个,对各会议的研究报道进行了总结。归纳了在ISI Web of Science中检索的2013年度发表的与CE技术相关的论文,并对这些论文在生物医药研究和检测器使用以及重要分析化学杂志发表的情况进行了分类说明。  相似文献   

12.
Two capillary electrophoresis methods for monitoring renally excreted varenicline, a highly effective drug prescribed for smoking cessation, in human urine were developed and compared. A method combining capillary electrophoresis with mass spectrometry was proposed for the fast analysis of varenicline (analysis time up to 7 min). Here, mass spectrometry was a prerequisite for achieving high sensitivity and selectivity of the analysis suitable for the quantification of a 15 ng/mL level of varenicline in un‐pretreated urine matrices. An alternative approach, two‐dimensional (column‐coupled) capillary electrophoresis with enhanced sample load capacity and ultraviolet detection, was proposed as a low‐cost alternative to capillary electrophoresis with mass spectrometry. The isotachophoresis on‐line sample treatment included simple elimination of the major matrix constituents and stacking of the sample in a large volume so that threefold lower quantitation limits could be easily achieved in comparison to the capillary electrophoresis with mass spectrometry. On the other hand, longer analysis time (ca. 4.5‐fold) and more complex electrolyte system in the coupled zone electrophoresis step (including two additives enhancing separation selectivity, i.e. isopropanol and cyclodextrin) were prerequisites for the complete separation of varenicline from the sample matrix. Anyway, both the developed methods were validated according to the Food and Drug Administration guidelines showing favorable performance parameters, suitable for their routine biomedical use.  相似文献   

13.
A novel aptamer‐based CE with chemiluminescence (CL) assay was developed for highly sensitive detection of human immunoglobulin E (IgE). The IgE aptamer was conjugated with gold nanoparticles (AuNPs) to form AuNPs‐aptamer that could specifically recognize the IgE to produce an AuNPs‐aptamer‐IgE complex. The mixture of the AuNPs‐aptamer‐IgE complex and the unbounded AuNPs‐aptamer could be effectively separated by CE and sensitively detected with luminol‐H2O2 CL system. By taking the advantage of the excellent catalytic behavior of AuNPs on luminol‐H2O2 CL system, the ultrasensitive detection of IgE was achieved. The detection limit of IgE is 7.6 fM (S/N = 3) with a linear range from 0.025 to 250 pM. Successful detection of IgE in human serum samples was demonstrated and the recoveries of 94.9–103.2% were obtained. The excellent assay features of the developed approach are its specificity, sensitivity, adaptability, and very small sample consumption. Our design provides a methodology model for determination of rare proteins in biological samples.  相似文献   

14.
Carbohydrates having sulfate groups such as glycosaminoglycans and chemically synthesized sucrose sulfate show interesting and important biological activities. We adapted CE with indirect UV detection technique to the determination of sulfate ester in sulfated carbohydrates, which were previously hydrolyzed with HCl. The liberated sulfate ion was analyzed using a background electrolyte consisting of triethanolamine‐buffered chromate with hexamethonium bromide. Sulfate contents of glucose 3‐sulfate and sucrose octasulfate used as a model were in good agreement with theoretical values (accuracy, 95.9–96.7 and 97.4–101.9%, respectively), and relative standard deviation values run‐to‐run were 0.977 and 1.90%, respectively. We applied the method to the determination of the sulfate contents of some glycosaminoglycan samples and showed that the contents were in good agreement with those calculated from sulfur content. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
《Electrophoresis》2017,38(13-14):1780-1787
An enzyme and antibody dual labeled gold nanoparticles enhancing chemiluminescence strategy was developed for highly sensitive CE immunoassay (IA) of prostate‐specific antigen (PSA). In this work, gold nanoparticles were labeled with horseradish peroxidase and antiprostate specific antigen‐antibody, and used as the marker (Ab*). After PSA (antigen, Ag) was added into the system, a noncompetitive immune reaction was happen between Ab* and Ag to form an immune complex (Ag–Ab*). Subsequently, the obtained Ag–Ab* and unreacted Ab* were separated by CE, and the chemiluminescence intensity of Ag‐Ab* was used to estimate PSA concentration. The calibration curve showed a good linearity in the range of 0.25–10 ng/mL. Based on a S/N of 3, the detection limit for PAS was estimated to be 0.092 ng/mL. Proposed CE method was applied for PSA quantification in human serum samples from healthy volunteers and patients with prostate cancer. The obtained results demonstrated that the proposed CE method may serve as an alternative tool for clinical analysis of PSA.  相似文献   

16.
A new kind of flow gating interface (FGI) has been designed for online connection of CE with flow‐through analytical techniques. The sample is injected into the separation capillary from a space from which the BGE was forced out by compressed air. A drop of sample solution with a volume of 75 nL is formed between the outlet of the delivery capillary supplying the solution from the flow‐through apparatus and the entrance to the CE capillary; the sample is hydrodynamically injected into the CE capillary from this drop. The sample is not mixed with the surrounding BGE solution during injection. The functioning of the proposed FGI is fully automated and the individual steps of the injection process are controlled by a computer. The injection sequence lasts several seconds and thus permits performance of rapid sequential analyses of the collected sample. FGI was tested for the separation of equimolar 50 μM mixture of the inorganic cations K+, Ba2+, Na+, Mg2+, and Li+ in 50 mM acetic acid/20 mM Tris (pH 4.5) as BGE. The obtained RSD values for the migration times varied in the range 0.7–1.0% and the values for the peak area were 0.7–1.4%; RSD were determined for ten repeated measurements.  相似文献   

17.
The stacking effect on carboxylated magnetite core–shell nanoparticles using sodium borate buffer pH 9.5 as the background electrolyte is presented. The ionic strength of the background electrolyte ranged from 5 to 100 mM, and the ionic strength of a sample zone ranged from 5 to 100 mM. Moreover, water was used as the sample dispersant. Both stacking and de‐stacking effects were observed when conductivities of the sample zone and the background electrolyte differed. An explanation of carboxylated magnetic core‐shell nanoparticles behavior was suggested based on the Derjaguin–Landau–Verwey–Overbeek theory supposing that the aggregation point is defined by the energetic barrier as the sum of energies given by electrostatic interactions and Van der Waals interactions. Moreover, the stacking conditions were applied for the evaluation of the lowest detectable dilution of magnetic nanoparticles. The carboxylated magnetic nanoparticles were dispersed in 10 mM borate/NaOH pH 9.5 and injected for 60 s to the background electrolyte composed of 100 mM borate/NaOH pH 9.5 that allowed the detection of 100‐fold diluted nanoparticles.  相似文献   

18.
Capillary gel electrophoresis (CGE) is a powerful tool for the analysis of oligonucleotides owing to its extraordinary resolving power. However, the only feasible injection mode for CGE, electrokinetic injection, can cause bias of the injected amount and thus reproducibility issues for CGE methods. Although the source of the bias in electrokinetic injection for analysis of small molecules by capillary zone electrophoresis has long been identified, there are very few studies on electrokinetic injection issues for biological molecules analyzed by CGE. In this study, we report three issues related to electrokinetic injection for oligonucleotides. First, the relationship between the injection amount and the sample solution resistance is not always linear for oligonucleotides, as has been observed for small molecules. Second, the injecting water prior to an oligonucleotide sample dramatically improves the reproducibility of both the injected amount and resolution through a ‘stacking‐like’ mechanism. Third, optimizing the gel concentration dramatically increases the amount of oligonucleotide that is injected into the column. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
高效毛细管电泳分离及检测蛋氨酸对映体   总被引:1,自引:0,他引:1  
蛋氨酸(Methionine)学名甲硫基丁氨酸,分子式C5H11NO2S,相对分子质量149.2。在蛋白质合成中,蛋氨酸是信息核糖核酸“翻译”成蛋白质过程中的第一步。无蛋氨酸的存在,蛋白质生物的合成就无法开始。适用于防治肝脏疾病和砷中毒,也用作食品的添加剂。蛋氨酸有D,L两种构型。目前尚未见用Cu^2+做手性选择剂毛细管电泳电化学拆分D,L-蛋氨酸的报道。电化学检测(主要是安培检测和电导检测)具有操作简单、维护方便、无须衍生化处理等优点,  相似文献   

20.
Ji X  He Z  Ai X  Yang H  Xu C 《Talanta》2006,70(2):353-357
A competitive immunoassay for clenbuterol (CLB) based on capillary electrophoresis with chemiluminescence (CL) detection was established. The method was based on the competitive reaction of horseradish peroxidase (HRP)-labeled CLB (CLB-HRP) and free CLB with anti-CLB antiserum. The factors affecting the electrophoresis and CL detection were systematically investigated with HRP as a model sample. Under the optimal conditions, the tracer CLB-HRP and the immunoassay complex were separated, and the linear range and the detection limit (S/N = 3) for CLB were 5.0-40 nmol l−1 and 1.2 nmol l−1, respectively. The proposed method has been applied satisfactorily in the analysis of urine sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号