首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Pressurized CEC (pCEC) coupled with ESI‐QTOF‐MS using a sheathless interface was applied for metabolomics to develop an alternative analytical method for metabolic profiling of complex biofluid samples such as urine. The hyphenated system was investigated with mixed standards and pooled urine samples to evaluate its precision, repeatability, linearity, sensitivity, and selectivity. The applied voltage, mobile phase, and gradient elution were optimized and applied for the analysis of urinary metabolites. Multivariate data analysis was subsequently performed and used to distinguish lung cancer patients from healthy controls successfully. High separation efficiency has been achieved in pCEC due to the EOF. For metabolite identification, the pCEC‐MS separation mechnism was helpful for discriminating the fragment ions of glutamine conjugates from co‐eluted metabolites. Three glutamine conjugates, including phenylacetylglutamine, acylglutamine C8:1, and acylglutamine C6:1 were identified among 16 differential urinary metabolites of lung cancer. Receiver‐operating‐characteristic analysis of acylglutamine C8:1 resulted in an area‐under‐curve value of 0.882. Overall, this work suggests that this pCEC‐ESI‐QTOF‐MS method may provide a novel and useful platform for metabolomic studies due to its superior separation and identification.  相似文献   

2.
Chronic unpredictable mild stress (CUMS) is a well‐validated model of depression. In this study, a urinary metabonomics method based on the NMR spectrometry was used to study the metabolic perturbation in CUMS‐induced rat depression model. With pattern recognition analysis, a clear separation of CUMS rats and healthy controls was achieved, and nine endogenous metabolites contributing to the separation were identified. CUMS‐treated rats were characterized by the increase of glycine, pyruvate, glutamine, and asparagines, as well as the decrease of 2‐oxoglutarate, dimethylglycine, citrate, succinate, and acetate. The urinary biochemical changes related to the metabolic disturbance in CUMS induced depression, and the possible correlations with live qi stagnation in traditional Chinese medicine are discussed. The work shows that CUMS is a reliable model for studying depression, and the noninvasive urinary metabolomic method is a valuable tool to investigate the biochemical pertubations in depression as an early diagnostic means. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
A rapid and sensitive ultra‐high performance liquid chromatography–mass spectrometry (UPLC‐MS/MS) method was developed and validated for the quantification of 10 major active constituents in rat urine after oral administration of Shensong Yangxin Capsule (SSYX) using diazepam as an internal standard (IS). The urine samples were pretreated and extracted by solid‐phase extraction prior to UPLC. Chromatographic separation was achieved on a Waters C18 (2.1 × 50 mm, 1.7 µm) column using a gradient elution program with 0.1% formic acid aqueous solution and acetonitrile at a flow rate of 0.4 mL/min. Detection and quantitation were accomplished by a hybrid quadrupole mass spectrometer using electrospray ionization source and multiple reaction monitoring in the positive ionization mode. The mass transition ion‐pairs (m/z) for quantitation were all optimized and the total run time was 4.50 min. The specificity, linearity, accuracy, precision, recovery, matrix effect and stabilities were all validated for the analytes in urine samples. The validation results indicated that this method was simple, rapid, specific and reliable. The proposed method was successfully applied to investigate the urinary excretion kinetics of 10 compounds in rat after oral administration of SSYX. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
A metabonomic study on biochemical changes in the urine of type 2 diabetes mellitus (T2DM) patients after the treatment of sulfonylurea (SU) antidiabetic drugs was performed. An ultra‐performance liquid chromatography/mass spectrometry (UPLC/MS) method was used to generate metabolic fingerprints for the metabonomic analysis of urinary samples obtained from 20 T2DM patients without any drug treatment and 20 T2DM patients treated with SU antidiabetic drugs and 20 normal glucose tolerance subjects. The resulting data were subjected to chemometric analysis (principal component analysis and partial least squares discriminant analysis) to investigate the effect of SU antidiabetic drugs on urinary metabolite profiles of T2DM patients. Biomarkers such as xanthine, phenylalanine, tryptophan, hippurate, phenylacetylglutamine, carnitine C8:1, carnitine C10:3, uric acid and citrate were found to be responsible for the separation of T2DM and SU‐treated groups, which indicates a potential effect of SU on energy metabolism, Tricarboxylic acid (TCA) cycle, gut microflora metabolism and oxidative stress. The study may be helpful to the understanding of the action of mechanism of SU antidiabetic drugs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
A simple LC‐MS/MS method was developed and validated for quantitatively analyzing six classes of 26 abused drugs and metabolites in human urine: (1) illicit drugs; (2) opiates; (3) synthetic opioids; (4) sedative; (5) stimulants; and (6) γ‐aminobutyric acid analogs. All urine samples were diluted with a mixture of isotope‐labeled internal standards, hydrolyzed with β‐glucuronidase and directly injected in a gradient chromatographic run. The mobile phase was composed of 0.1% formic acid in water and 0.1% of formic acid in methanol. A 4.9 min run time using the multiplexing driver and ultra‐biphenyl column (50 × 2.1 mm, 5 µm, RESTEK) allowed all drugs to have sufficient resolution in a short elute time. The overlapping liquid chromatography runs and scheduled multiple reaction monitoring acquisition method resulted in a higher overall throughput for the system. The result was linear over the studied range (2–16,000 ng/mL) for all compounds with correlation coefficients r2 ≥ 0.995. The intra‐day and inter‐day precisions and accuracies were within 15% and recovery was between 83 and 115% for all analytes. Freeze–thaw stability for three cycles and long‐term stability (57 days, ?20°C) were established for all analytes. The cross‐validation between College of American Pathologists and in‐house was validated (0.06% ≤ bias ≤ 12.3%). The applicability of the method was examined by analyzing urine samples from chronic pain patients (n = 610). Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
A novel chiral method was developed and validated to determine N‐acetyl‐glutamine (NAG) enantiomers by liquid chromatography–tandem mass spectrometry (LC–MS/MS). Enantioseparation was achieved on a Chiralpak QD‐AX column (150 × 4.6 mm i.d., 5 μm) using methanol–water (50 mm ammonium formate, pH 4.3; 70:30, v/v) at a flow rate of 500 μL/min. The detection was operated with an electrospray ionization source interface in positive mode. The ion transition for NAG enantiomers was m/z 189.0 → 130.0. The retention time of N‐acetyl‐l ‐glutamine and N‐acetyl‐d ‐glutamine were 15.2 and 17.0 min, respectively. Calibration curves were linear over the range of 0.02–20 μg/mL with r > 0.99. The deviation of accuracy and the coefficient of variation of within‐run and between‐run precision were within 10% for both enantiomers, except for the lower limit of quantification (20 ng/mL), where they deviated <15%. The recovery was >88% and no obvious matrix effect was observed. This method was successfully applied to investigate the plasma protein binding of NAG enantiomers in rats. The results showed that the plasma protein binding of NAG enantiomers was stereoselective. The assay method also exhibited good application prospects for the clinical monitoring of free drugs in plasma.  相似文献   

7.
This study presents a high‐performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for the simultaneous determination of antofloxacinin and its main metabolite – N ‐demethylated metabolite (N‐ DM) – in human urine. Ornidazole was used as the internal standard. This was a clinical urine recovery study, in which 10 healthy Chinese volunteers were intravenously administered a single 200 mg dose of antofloxacin hydrochloride. Compounds were extracted by albumen precipitation, after which samples were isocratically eluted using a Poroshell 120 SB‐C18 column, and were analysed using HPLC–MS/MS under electronic spray ionization positive ion mode. The method was successfully applied in a urine pharmacokinetic study of antofloxacinin, with a detection range of 0.02/0.01 to 200/100 μg/mL (for antofioxacin/N‐ DM).The average percentages of antofioxacin/N‐ DM measured in urinary excretion frp, 10 volunteers were 54.9 ± 5.7/8.2 ± 2.5% in 120 h duration.  相似文献   

8.
Heparan sulfate is a linear polysaccharide and serves as an important biomarker to monitor patient response to therapies for MPS III disorder. It is challenging to analyze heparan sulfate intact owing to its complexity and heterogeneity. Therefore, a sensitive, robust and validated LC–MS/MS method is needed to support the clinical studies for the quantitation of heparan sulfate in biofluids under regulated settings. Presented in this work are the results of the development and validation of an LC–MS/MS method for the quantitation of heparan sulfate in human urine using selected high‐abundant disaccharides as surrogates. During sample processing, a combination of analytical technologies have been employed, including rapid digestion, filtration, solid‐phase extraction and chemical derivatization. The validated method is highly sensitive and is able to analyze heparan sulfate in urine samples from healthy donors. Disaccharide constitution analysis in urine samples from 25 healthy donors was performed using the assay and demonstrated the proof of concept of using selected disaccharides as a surrogate for validation and quantitation.  相似文献   

9.
Tobacco smoking is a preventable main cause of fatal diseases. Accurate measurements of the effects it has on neurotransmitters are essential in developing new strategies for smoking cessation. Moreover, measurements of neurotransmitter levels can aid in developing drugs that counteract the effects of smoking. The aim of this study is to develop and validate a fast, simultaneous and sensitive method for measuring the levels of neurotransmitters in rat brain after the exposure of tobacco cigarettes. The selected neurotransmitters include dopamine, GABA, serotonin, glutamine and glutamate. The method is based on high-performance liquid chromatography–tandem mass spectrometry. Chromatographic separation was achieved within 3 min using a Zorbax SB C18 column (3.0 × 100 mm, 1.8 μm particle size). The mobile phase consisted of HPLC-grade water and acetonitrile each containing 0.3% heptafluorobutyric acid and 0.5% formic acid at gradient conditions. The linear range was 0.015–0.07, 825–7,218, 140–520, 63.42–160.75 and 38.25 × 103 to 110.35 × 103 ng/ml for dopamine, GABA, serotonin, glutamine and glutamate, respectively. Inter- and intra-run accuracy were in the range 97.82–103.37% with a precision (CV%) of ≤0.90%. The results revealed that 4 weeks of cigarette exposure significantly increased neurotransmitter levels after exposure to tobacco cigarettes in various brain regions, including the hippocampus and the amygdala. This increase in neurotransmitters levels may in turn activate the nicotine dependence pathway.  相似文献   

10.
This report describes the development and validation of an LC‐MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87–99%, and that from urine samples was 85–95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra‐day and inter‐day assays in plasma and urine samples, and the accuracy was 86–114% in plasma, and 94–105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
The aim of this study was to demonstrate the differences of metabolomics changes in a hyperalgesia model and find potent biomarkers of hyperalgesia. Seven rats were placed in metabolic cages. An emulsion containing 500 μg of Complete Freund's adjuvant (CFA) was used to induce hyperalgesia. Urine samples were collected prior to the injection of CFA and on post‐injection days 1, 3 and 7. Ultraperformance liquid chromatography, coupled with quadrupole‐time‐of‐flight mass spectrometry (UHPLC‐Q‐TOF/MS), was used for a quantitative analysis of urinary metabolic changes in the CFA‐induced hyperalgesia model. Differences between the metabolic profiles of the rats in the four groups were analyzed using partial least squares discriminant analysis. Thirty‐four potential urine metabolite biomarkers were identified, which changed in a trend similar to the pain threshold. These potential biomarkers were involved in 11 metabolic pathways, as follows: alanine, aspartate, and glutamate metabolism; ascorbate and aldarate metabolism; glycerolipid metabolism; glycerophospholipid metabolism; histidine metabolism; phenylalanine metabolism; sphingolipid metabolism; tryptophan metabolism; tyrosine metabolism; valine, leucine and isoleucine biosynthesis; and vitamin B6 metabolism. These results may improve our understanding of hyperalgesia and provide a basis for the clinical diagnosis of hyperalgesia.  相似文献   

12.
A robust, specific and fully validated LC‐MS/MS method as per general practices of industry has been developed for estimation of lacidipine (LAC) with 100 μL of human plasma using lacidipine‐13C8 as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode. A simple liquid–liquid extraction process was used to extract LAC and IS from human plasma. The total run time was 3.0 min and the elution of LAC and IS occurred at 1.96 and 1.97 min; this was achieved with a mobile phase consisting of 5 mm ammonium acetate buffer–acetontrile (15:85 v/v) at a flow rate of 0.60 mL/min on a Zorbax SB C18 (50 × 4.6 mm, 5 µm) column. A linear response function was established for the range of concentrations 50–15,000 pg/mL (r > 0.998) for LAC. The current developed method has negligible matrix effect and is free from unwanted adducts and clusters which are formed owing to system such as solvent or mobile phase. The developed assay method was applied to an oral pharmacokinetic study in humans and successfully characterized the pharmacokinetic data up to 72 h. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
Tiopronin (TP) is a synthetic thiol compound without chromophore. By optimizing the chromatographic conditions and sample preparation processes, an improved LC‐MS/MS analytical method without derivatization has been developed and validated to determine TP concentrations in human plasma. After reduction with 1,4‐dithiothreitol, plasma samples were deproteinized with 10% perchloric acid. The post‐treatment samples were analyzed on a C8 column interfaced with a triple quadrupole tandem mass spectrometer in negative electrospray ionization mode. Methanol–5 mmol/L ammonium acetate (20:80, v/v) was used as the isocratic mobile phase. The assay was linear over the concentration range of 40.0–5000 ng/mL. The intra‐ and inter‐day precisions were within 12.9% in terms of relative standard deviation and the accuracy within 5.6% in terms of relative error. This simple and sensitive LC‐MS/MS method with short analytical time (3.5 min each sample) was successfully applied to the pharmacokinetic study of TP in healthy Chinese male volunteers after an oral dose of 300 mg TP. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
基于HPLC/Q-TOF MS的4种农药联合暴露人群的代谢组学研究   总被引:1,自引:0,他引:1  
采用基于高效液相色谱-飞行时间质谱联用(HPLC-TOF MS)的代谢组学方法,研究了啶虫脒、高效氯氟氰菊酯、联苯菊酯、甲氨基阿维菌素苯甲酸盐4种农药联合暴露所致的施药人群尿液中内源性代谢物的变化。采集30位农民喷洒4种复合农药前和喷洒农药期1,3,5,7 d的尿液进行检测。提取正常尿液中常见代谢物并通过质控样品评价手段进行分析,结果表明该方法具有良好的稳定性和精密度,可用于尿液中代谢物分析。多变量分析结果表明,暴露人群施药前后尿液的代谢物含量存在较大差异。对选取的36个差异离子进行鉴定,确定了8个生物标志物的结构。结果显示联合暴露组人群尿液中多巴胺、5-羟色胺、酪氨酸、色氨酸、牛磺酸和马尿酸的含量显著下降;犬尿素和肌酸的含量显著上升。4种农药联合暴露导致接触人群尿液中色氨酸代谢途径的中间产物含量降低,肝代谢和能量代谢相关的代谢物蓄积,可能与神经系统和肝脏功能的受损有关。  相似文献   

15.
Elevated levels of trans‐indolyl‐3‐acryloylglycine (IAcrGly) have been reported in the urine of people with various conditions including pervasive developmental disorders (PDDs) such as autism and Asperger syndrome. Reversed‐phase high‐performance liquid chromatography with ultra‐violet detection using traditional particle silica‐based columns subsequent to solid‐phase extraction (SPE) has been the preferred assay method; requiring long analytical run times, high flow rates and high solvent usage. Recent developments in monolithic HPLC column technology facilitated the development of a novel analytical method, for the detection and quantification of urinary IAcrGly. The revised method eliminates the requirement for SPE pre‐treatment, reduces sample run‐time and decreases solvent volumes. Five urine samples from people diagnosed with PDD were run in quadruplicate to test the intra‐ and inter‐day reliability of the new method based on retention time, peak area and peak height for IAcrGly. Detection was by UV with IAcrGly confirmation by MS/MS‐MS. Relative standard deviations showed significant improvement with the new method for all parameters. The new method represents a major advancement in the detection and quantification of IAcrGly by reducing time and cost of analysis whilst improving detection limits and reproducibility. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
An ultra‐high‐performance liquid chromatography–tandem mass spectrometry (UHPLC‐MS/MS) method for the analysis of cefazolin and cefalothin in human plasma (total and unbound), urine and peritoneal dialysate has been developed and validated. Total plasma concentrations are measured following protein precipitation and are suitable for the concentration range of 1–500 µg/mL. Unbound concentrations are measured from ultra‐filtered plasma acquired using Centrifree® devices and are suitable for the concentration range of 0.1–500 µg/mL for cefazolin and 1–500 µg/mL for cefalothin. The urine method is suitable for a concentration range of 0.1–20 mg/mL for cefazolin and 0.2–20 mg/mL for cefalothin. Peritoneal dialysate concentrations are measured using direct injection, and are suitable for the concentration range of 0.2–100 µg/mL for both cefazolin and cefalothin. The cefazolin and cefalothin plasma (total and unbound), urine and peritoneal dialysate results are reported for recovery, inter‐assay precision and accuracy, and the lower limit of quantification, linearity, stability and matrix effects, with all results meeting acceptance criteria. The method was used successfully in a pilot pharmacokinetic study with patients with peritoneal dialysis‐associated peritonitis, receiving either intraperitoneal cefazolin or cefalothin. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
A rapid, sensitive and selective liquid chromatography/tandem mass spectrometry method (LC‐MS/MS) was developed and validated for simultaneous determination of albiflorin and paeoniflorin in rat plasma using geniposide as an internal standard. Plasma samples were extracted by solid‐phase extraction. Chromatographic separation was carried out on a Zorbax SB‐C18 analytical column (150 × 2.1 mm × 5 µm) with 0.1% formic acid–acetonitrile (70:30, v/v) as the mobile phase. Detection was performed by multiple reaction monitoring mode using electrospray ionization in the positive ion mode. The total run time was 3.0 min between injections. The calibration curves were linear over a range of 1–1000 ng/mL for albiflorin and 2–2000 ng/mL for paeoniflorin. The overall precision and accuracy for all concentrations of quality controls and standards were better than 15%. Mean recovery was determined to be 87.7% for albiflorin and 88.8% for paeoniflorin. The validated method was successfully applied to the pharmacokinetic study of albiflorin and paeoniflorin in rat plasma after oral administration of Radix Paeoniae Alba extract and Tang‐Min‐Ling‐Wan. The pharmacokinetic parameters showed that albiflorin and paeoniflorin from Tang‐Min‐Ling‐Wan were absorbed more rapidly with higher concentrations in plasma than that from Radix Paeoniae Alba extract. The results provided a meaningful basis for evaluating the clinical applications of traditional Chinese medicine. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
In the past we have reported significant cognitive deficits in mice receiving 5‐fluorouracil in combination with low‐dose methotrexate. To explain such interactions, a pharmacokinetic study was designed. A sensitive bio‐analytical method was therefore developed and validated for 5‐fluorouracil and methotrexate in mouse plasma, brain and urine with liquid chromatography coupled to a single quadrupole mass spectrometer. Chromatographic separation was accomplished by Agilent® Zorbax® SB‐C18 column, with isocratic elution (5 mM ammonium acetate and methanol, 70:30, %v/v) at a flow rate of 300 μL/min. The limit of quantitation for both drugs was 15.6 ng/mL (plasma and brain) and 78.1 ng/mL (urine), with interday and intraday precision and accuracy ≤15% and a total run time of 6 min. This bio‐analytical method was used for the pharmacokinetic characterization of 5‐fluorouracil and methotrexate in mouse plasma, brain and urine over a period of 24 h. This method allowed characterization of the brain concentrations of 5‐fluorouracil over a period of 24 h. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
The metabolic profile of polar (methanol) and non‐polar (hexane) extracts of Curcuma domestica, a widely used medicinal plant, was established using various different analytical techniques, including GC‐FID, GC‐MS, HR‐GC‐MS and analytical HPLC‐ESI‐MS/MS by means of LTQ‐Orbitrap technology. The major non‐volatile curcuminoids curcumin, demethoxycurcumin and bisdemethoxycurcumin were identified when their chromatographic and precursor ion masses were compared with those of authentic standard compounds. In this paper we describe for the first time a GC/MS‐based method for metabolic profiling of the hydrophilic extract. We also identified 61 polar metabolites as TMS derivatives. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
An LC–MS/MS‐based bioanalytical method has been developed to measure the concentration of L‐threonate at its endogenous level in human plasma. Following isotope dilution and protein precipitation, the samples were acetylated and chromatographed under reversed‐phase conditions for baseline separation of the derivatized L‐threonate and its stereoisomer D‐erythronate. The method was assessed by a fit‐for‐purpose validation with a calibration range from 100 to 10,000 ng/mL. The intra‐run coefficients of variation (CVs) were <3.6% and the inter‐run CV was 3.2% for the QC samples at endogenous level. At the lower limit of quantitation, the intra‐run CV was 6.1% and the average inaccuracy was ?1.4%. This method provides an efficient and reliable quantitation of L‐threonate and could be useful to certain biomarker investigators.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号