首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Sol-gel coating with covalently bonded low-molecular-weight (MW<300 Da) poly(ethylene glycol) (PEG) chains was developed for capillary microextraction (CME). The sol-gel chemistry proved effective in the immobilization of low-molecular-weight PEGs thanks to the formation of chemical bonds between the organic-inorganic hybrid sol-gel PEG coating and the fused silica capillary inner surface. This chemical anchorage provided excellent thermal and solvent stability to the created sol-gel PEG coating as is evidenced by its high upper limit of allowable conditioning temperature (340 degrees C) and its practically identical performance before and after rinsing with various solvents. The prepared sol-gel PEG coating provided simultaneous extraction of moderately polar and highly polar analytes from aqueous samples without requiring derivatization, pH adjustment or salting-out procedures. Detection limits on the order of nanogram per liter (ng/L) were achieved in CME-GC-flame ionization detection experiments designed for the preconcentration and trace analysis of both highly polar and moderately polar compounds extracted directly from aqueous media using sol-gel short-chain PEG coated microextraction capillaries.  相似文献   

2.
A sol-gel coating with anchored methyl groups was developed for capillary microextraction hyphenated on-line with high-performance liquid chromatography (HPLC). This was accomplished by using methyltrimethoxysilane as the sol-gel precursor. The methyl group on the sol-gel precursor ultimately turned into a pendant group on the created sol-gel coating and was primarily responsible for the extraction of nonpolar analytes. A 40-cm segment of 0.25mm I.D. fused silica capillary containing the sol-gel methyl coating on the inner surface was installed as a sampling loop in an HPLC injection port. The analytes were extracted by the coating when an aqueous sample containing the analytes was passed through this capillary. The extracted analytes were then transferred to the HPLC column using isocratic elution with an acetonitrile/water mobile phase. This capillary demonstrated excellent extraction capability for polycyclic aromatic hydrocarbons and ketones. Unexpectedly, this coating also provided good extraction for polar analytes, including aromatic phenols, alcohols, and amines. Considering the fact that the methyl group is nonpolar in nature, such an extraction behavior of sol-gel methyl coating toward polar analytes is counterintuitive. Thus, sol-gel sorbents with short alkyl side chains have the potential to offer a polymer-free alternative to traditional sol-gel capillary microextraction (CME) media commonly prepared with the use of polymers in the sol solution. Elimination of polymers from the sol-gel coating solution is conducive to improving thermal stability and solvent tolerance of the created sol-gel extracting phase. This also makes the preparation of sol-gel coatings facile and cost-effective. Possessing excellent solvent stability, such sol-gel coatings offer the opportunity for effective on-line hyphenation of capillary microextraction with HPLC and other liquid-phase separation techniques that employ organo-aqueous mobile phases.  相似文献   

3.
A fiber coating from polyaniline (PANI) was electrochemically prepared and employed for solid phase microextraction (SPME) of some polycyclic aromatic hydrocarbons (PAHs) from water samples. The PANI film was directly electrodeposited on the platinum wire surface in sulfuric acid solution using cyclic voltammetry (CV) technique. The applicability of this coating was assessed employing a laboratory-made SPME device and gas chromatography with mass spectrometry (GC-MS) for the extraction of some PAHs from the headspace of aqueous samples. Application of wider potential range in CV led to a PANI with more stability against the temperature. The homogeneity and the porous surface structure of the film were examined by the scanning electron microscopy (SEM). The study revealed that this polymer is a suitable SPME fiber coating for extracting the selected PAHs. Important parameters influencing the extraction process were optimized and an extraction time of 40 min at 40 degrees C gave maximum peak area, when the aqueous sample was added with NaCl (20%, w/v). The synthesis of the PANI can be carried out conveniently and in a reproducible manner while it is rather inexpensive and stable against most of organic solvents. The film thickness of PANI can be precisely controlled by the number of CV cycles. The resulting thickness was roughly 20 microm after 20 cycles. At the optimum conditions, the relative standard deviation (RSD) for a double distilled water spiked with selected PAHs at ppb level were 8.80-16.8% (n = 3) and detection limits for the studied compounds were between 0.1-6 pg mL(-1). The performance of PANI was, also, compared with a commercial solid coated-based SPME fiber, carbowax/divinylbenzene (CW/DVB), under similar experimental conditions.  相似文献   

4.
张文敏  李青青  方敏  张兰 《色谱》2022,40(11):1022-1030
环境样品中多环芳烃(PAHs)含量较低且样品基质复杂,直接利用仪器进行含量测定比较困难,因此在仪器分析之前需要对环境样品进行必要的前处理。大多数前处理技术的萃取效率取决于萃取材料的特性。目前,金属有机骨架材料(MOFs)作为一种由金属离子与有机配体自组装而成的多孔材料,已经被用作固相微萃取(SPME)的涂层材料应用于PAHs的萃取,但是这些MOFs涂层材料由于目标物较难达到其深层的吸附位点,使得萃取过程往往需要较长的平衡时间;此外,大多数MOFs由单金属离子配位构成,能够提供的开放金属活性位点种类比较单一,较难获得最佳的萃取性能。这些问题在一定程度上限制了MOFs材料在SPME领域的应用。该研究制备了一种中空结构的双金属有机骨架材料(H-BiMOF),并将其作为SPME的涂层材料,用于萃取环境样品中痕量的PAHs。由于中空的结构和双金属的组成,H-BiMOF涂层材料拥有比表面积利用率高、传质距离短等优点,可以使萃取过程快速地达到平衡。同时,双金属的引入提供了种类丰富的金属活性位点,提高了对PAHs这类富电子云目标物的萃取效率。与气相色谱-串联质谱(GC-MS/MS)相结合,建立了一种用于环境水样中PAHs分析的新方法。所建立的分析方法具有检出限低(0.01~0.08 ng/L)、线性范围宽(0.03~500.0 ng/L)、重复性良好(相对标准偏差≤9.8%, n=5)等优点,并成功地用于实际湖水样品中7种PAHs的检测。实验结果表明,所建立的分析方法适用于环境样品中PAHs的分析与监测。  相似文献   

5.
6.
The electrochemical fiber coating (EFC) technique was used for the preparation of dodecylsulfate-doped polypyrrole (PPy-DS), and applied as a new fiber for solid-phase microextraction (SPME) procedures. PPy-DS film was directly electrodeposited on the surface of a platinum wire from an aqueous solution containing pyrrole and sodium dodecylsulfate, using cyclic voltammetry (CV). The effect of polymerization conditions and type of dopants on the thermal stability, adhesion and extraction characteristics of the fiber were investigated. The electron microscopy imaging of PPy-DS film suggested that the surface fiber coating was well-distributed with a porous structure. The fiber coating can be prepared easily in a reproducible manner, and it is inexpensive and has a stable performance at high temperatures (up to the 300 degrees C). The extraction properties of the fiber to eight polycyclic aromatic hydrocarbons (PAHs) were examined, using a headspace-SPME (HS-SPME) device coupled with gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). The results revealed study shows that PPy-DS as a SPME fiber coating is suitable for the successful extraction of PAHs. The effects of the extraction parameters including exposure time, sampling temperature, salt concentration, and stirring rate on the extraction efficiency have been studied. A satisfactory reproducibility for extractions from spiked water samples at PPb-level with R.S.D. < 7.6% (n = 7) was obtained. The calibration graphs were linear in the range of 0.5-100ng ml(-1) and detection limits for the selected PAHs were between 0.05-0.16 ng ml(-1). Comparing the HS-SPME results for extraction and determination of PAHs using PPy-DS fiber with the corresponding literature data using PDMS fiber shows that the proposed fiber has a better detection limit for low molecular weight PAHs. The life span and stability of PPy-DS fiber is good and it can be used more than 50 times at 250 degrees C without any significant change in sorption properties.  相似文献   

7.
A novel SPME-HPLC method was developed for the determination of trace amounts of polycyclic aromatic hydrocarbons (PAHs). It was found that the SPME device with C8H17-SBA-15 (C 8-SBA-15) mesoporous silica coating had high extraction efficiency, sufficient chemical and hydrothermal stability and good reversibility. The determination conditions for environmental pollutants like PAHs including extraction and desorption time, extraction temperature, ionic strength and stirring rate were optimized. Under optimized experimental conditions, results with good accuracy (with a recovery of 97.5–101.7%), precision (with a standard deviation of 0.15–1.07%) and low detection limit (LOD, 0.05–0.25 μg/L) were obtained, suggesting the SPME devices using chemical modified SBA-15 as coating material are promising in preconcentration, separation and determination of interested analytes in the future.  相似文献   

8.
Wu Y  Xia L  Chen R  Hu B 《Talanta》2008,74(4):470-477
A new method by combining headspace single drop microextraction (HS-SDME) with HPLC fluorescence detection for the determination of trace polycyclic aromatic hydrocarbons (PAHs) in environmental samples was developed. Aqueous solution of saturated beta-cyclodextrin was used as extraction solvent and five PAHs were employed as target analytes. The factors affecting the extraction efficiency were studied in detail and the optimal extraction conditions were established. Beta-cyclodextrin was found to play two important roles, one is the improvement of extraction efficiency of target analytes and the other is the enhancement of their fluorescence intensities in HPLC fluorescence detection. The detection limits for the target analytes were found to be in the range of 0.004-0.247ng/ml and the relative standard deviations (R.S.D.s) of 5.1-7.1% were obtained. The proposed method was applied to the analysis of trace PAHs in environmental samples with satisfactory results.  相似文献   

9.
Wu  Tong  Wang  Juntao  Liang  Weiqian  Zang  Xiaohuan  Wang  Chun  Wu  Qiuhua  Wang  Zhi 《Mikrochimica acta》2017,184(7):2171-2180

The authors describe a three-dimensional single layer graphitic carbon nitride-modified graphene composite (g-C3N4@G) deposited on a stainless steel wire by a sol-gel technique. The coated fiber was applied to direct immersion solid-phase microextraction of trace levels of polycyclic aromatic hydrocarbons (PAHs) from cosmetics samples prior to their determination by gas chromatography with mass spectrometry (GC-MS). Due to π stacking interaction and hydrophobic interaction between the g-C3N4@G coating and the analytes (naphthalene, acenaphthene, fluorene, phenanthrene, fluoranthene and pyrene), the fiber displays an excellent adsorption capability for the analytes. Under optimized conditions, the method has a wide linear range, low LODs (from 1.0 to 2.0 ng L−1), good repeatability and high recoveries. It was successfully applied to the determination of PAHs in cosmetics. The g-C3N4@G fiber also exhibited good durability.

Schematic of a three-dimensional single layer graphitic carbon nitride-modified graphene composite (g-C3N4@G) that was coated onto a stainless steel wire for the direct-immersion solid phase microextraction of trace levels of polycyclic aromatic hydrocarbons prior to gas chromatography-mass spectrometric detection.

  相似文献   

10.
A solid‐phase microextraction with carbon nanospheres coated fiber coupled with gas chromatographic detection was established for the determination of eight polycyclic aromatic hydrocarbons (naphthalene, biphenyl, acenaphthene, fluorine, phenanthrene, anthracene, fluoranthene, and pyrene) in water and soil samples. The experimental parameters (extraction temperature, extraction time, stirring rate, headspace volume, salt content, and desorption temperature) which affect the extraction efficiency were studied. Under the optimized conditions, good linearity between the peak areas and the concentrations of the analytes was achieved in the concentration range of 0.5‐300 ng/mL for water samples, and in the concentration range of 6.0‐2700 ng/g for soil samples. The detection limits for the analytes were in the range of 0.12‐0.45 ng/mL for water samples, and in the range of 1.53‐2.70 ng/g for soil samples. The method recoveries of the polycyclic aromatic hydrocarbons for spiked water samples were 80.10‐120.1% with relative standard deviations less than 13.9%. The method recoveries of the analytes for spiked soil samples were 80.40‐119.6% with relative standard deviations less than 14.4%. The fiber was reused over 100 times without a significant loss of extraction efficiency.  相似文献   

11.
A methodology for the extraction and quantification of 16 polycyclic aromatic hydrocarbons (PAHs) based on microwave-assisted extraction coupled with headspace solid-phase microextraction followed by gas chromatography/mass spectroscopy was validated for needles and bark of two pine species (Pinus pinaster Ait. and Pinus pinea L.). The limits of detection were below 0.92 ng g(-1) (dry weight) for needles and below 0.43 ng g(-1) (dw) for bark. Recovery assays were performed with two sample masses spiked at three levels and the overall mean values were between 70 and 110 % for P. pinaster and 75 and 129 % for P. pinea. In the first species, the increase in sample mass lowered the recoveries slightly for most PAHs, whereas for the second, the recoveries were higher for the needles. Naturally contaminated samples from 4 sites were analysed, with higher levels for urban sites (1,320 and 942 ng g(-1) (dw) vs. 272 and 111 ng g(-1) (dw) for needles and 696 and 488 ng g(-1) (dw) vs. 270 and 103 ng g(-1) (dw) for bark) than for rural ones and also for P. pinaster samples over P. pinea. It is also shown that gas-phase PAHs are predominant in the needles (over 65 % of the total PAHs) and that the incidence for particulate material in bark, reaching 40 % as opposed to a maximum below 20 % for the needles. The method has proved to be fit and improved some of the existing approaches, on the assessment of particulate PAHs and bark levels.  相似文献   

12.
A simple, low-cost, and effective cooling/heating-assisted headspace solid-phase microextraction (CHA–HS–SPME) device, capable of direct cooling the fiber to low temperatures and simultaneous heating the sample matrix to high temperatures, was fabricated and evaluated. It was able to cool down the commercial and handmade fibers for the effective tapping of volatile and semi-volatile species in the headspace of complex solid matrices, with minimal manipulation compared with conventional SPME. The CHA–HS–SPME system can create large temperature gaps (up to 200 °C) between the fiber and the sample matrix, because the cooling process is directly applied onto the fiber.  相似文献   

13.
This article introduces a simple, rapid, and reliable solid‐phase microextraction (SPME) method coupled with GC‐MS for the quantitative determination of 16 polycyclic aromatic hydrocarbons in water. In this study, the Taguchi experimental design was used to optimize extraction conditions of polycyclic aromatic hydrocarbons using SPME method to obtain highly enriched analytes. Consequently, quantitative determination of polycyclic aromatic hydrocarbons in water was achieved by GC‐MS technique. The selected parameters affecting enrichment of polycyclic aromatic hydrocarbons were sample extraction time, stirring speed, temperature, ionic strength, and pH. The study revealed that optimal operating conditions were found to be 90‐min extraction time, 1400 rpm stirring speed, and 60°C sample temperature. The effect of ionic strength and pH were shown to be insignificant. Optimized conditions were also reevaluated by placing the 16 polycyclic aromatic hydrocarbons into several subgroups based on their molecular weight. The extraction efficiency of polycyclic aromatic hydrocarbons with low molecular weight was shown to be a function of only the extracting temperature. Satisfactory results were obtained for linearity (0.983–0.999), detection limits (2.67–18.02 ng/L), accuracy (71.2–99.3%), and precision (4.3–13.5%). The optimum conditions reported by other design approaches were evaluated and generalized optimum conditions were suggested.  相似文献   

14.
A method for monitoring the contamination of soil with polycyclic aromatic hydrocarbons (PAHs) is introduced. Drying at elevated temperature is omitted to avoid losses of the more volatile constituents (primarily naphthalene). The soil sample, including its natural water content, is extracted with 2-methoxyethanol and cleaned up using a disposable C8 cartridge and the PAHs are eluted with pentane, concentrated and measured by capillary gas chromatography with flame ionization detection. Determination limits between 15 and 35μg kg?1 are obtained and the recovery is 80–90% measured at the 125 μg kg?1 spike level, except for naphthalene (66%). Special attention is given to the design of the spiking technique, which simulates natural incorporation as far as possible, takes account of evaporation losses and therefore allows “real” recovery rates to be determined.  相似文献   

15.
Zhang  Xi  Zang  Xiao Huan  Wang  Jun Tao  Wang  Chun  Wu  Qiu Hua  Wang  Zhi 《Mikrochimica acta》2015,182(13):2353-2359

A nanoporous carbon derived from an aluminum-based metal-organic framework was deposited on stainless steel wires in a sol–gel matrix. The resulting fibers were applied to the solid-phase microextraction of the polycyclic aromatic hydrocarbons (PAHs) naphthalene, acenaphthene, fluorene, phenanthrene and anthracene from water and soil samples. The fiber was then directly inserted into the GC injector and the PAHs were quantified by GC-MS. The effects of salt addition, extraction temperature, extraction time, sample volume and desorption conditions on the extraction efficiency were optimized. A linear response to the analytes was observed in the 0.1 to 12 μg∙L−1 range for water samples, and in the 0.6 to 30 μg∙kg−1 for soil samples, with the correlation coefficients ranging from 0.9934 to 0.9985. The limits of detection ranged from 5.0 to 20 ng∙L−1 for water samples, and from 30 to 90 ng∙kg−1 for soil samples. The recoveries of spiked samples were between 72.4 and 108.0 %, and the precision, expressed as the relative standard deviations, is <12.8 %.

A MOF derived nanoporous carbon coated fiber for use in solid-phase microextraction was prepared via sol–gel technology. The coated fiber has a porous, rough and wrinkled structure, and shows a high thermal stability, good extraction repeatability and long lifetime. The established HS-SPME-GC-MS method is suitable for the determination of the PAHs from water and soil samples.

  相似文献   

16.
17.
Periodic mesoporous organosilica based on alkylimidazolium ionic liquid (PMO-IL) was prepared and used as a highly porous fiber coating material for solid-phase microextraction (SPME). The prepared nanomaterial was immobilized onto a stainless steel wire for fabrication of the SPME fiber. The fiber was evaluated for the extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions in combination with gas chromatography–mass spectrometry (GC–MS). A one at-the-time optimization strategy was applied for optimizing the important extraction parameters such as extraction temperature, extraction time, ionic strength, stirring rate, and desorption temperature and time. In optimum conditions, the repeatability for one fiber (n = 3), expressed as relative standard deviation (R.S.D.%), was between 4.3% and 9.7% for the test compounds. The detection limits for the studied compounds were between 4 and 9 pg mL−1. The developed method offers the advantage of being simple to use, with shorter analysis time, lower cost of equipment, thermal stability of fiber and high relative recovery in comparison to conventional methods of analysis.  相似文献   

18.
Two methods to estimate distribution coefficients (K) between air and poly(dimethylsiloxane) (PDMS) coating of solid-phase microextraction (SPME) fibers for eight low molecular polycyclic aromatic hydrocarbons (PAHs) there are presented. The PDMS phases were used for determination of the coefficients according to equilibrium theory with help of a developed static calibration system (SCS). Another way to estimate the coefficients is based on the use of a linear relationship between the logarithm of the coefficients (log K) and linear temperature-programmed retention indexes (LTPRI) of the compounds without necessity to calibrate. The log K values for both of methods ranged from 5.2 (naphthalene) to 8.9 (pyrene) at 22 degrees C. Relative standard deviation (R.S.D.) of log K for each compound determined by static calibration was no more than 5.3%. R.S.D. of retention times for LTPRI indices did not exceed 0.28% for repeated injection. All experiments were implemented on a GC-MS system.  相似文献   

19.
For the first time, Vacuum Assisted Headspace Solid Phase Microextraction (Vac-HSSPME) is used for the recovery of polycyclic aromatic hydrocarbons (PAHs) from solid matrices. The procedure was investigated both theoretically and experimentally. According to the theory, reducing the total pressure increases the vapor flux of chemicals at the soil surface, and hence improves HSSPME extraction kinetics. Vac-HSSPME sampling could be further enhanced by adding water as a modifier and creating a slurry mixture. For these soil-water mixtures, reduced pressure conditions may increase the volatilization rates of compounds with a low KH present in the aqueous phase of the slurry mixture and result in a faster HSSPME extraction process. Nevertheless, analyte desorption from soil to water may become a rate-limiting step when significant depletion of the aqueous analyte concentration takes place during Vac-HSSPME. Sand samples spiked with PAHs were used as simple solid matrices and the effect of different experimental parameters was investigated (extraction temperature, modifiers and extraction time). Vac-HSSPME sampling of dry spiked sand samples provided the first experimental evidence of the positive combined effect of reduced pressure and temperature on HSSPME. Although adding 2 mL of water as a modifier improved Vac-HSSPME, humidity decreased the amount of naphthalene extracted at equilibrium as well as impaired extraction of all analytes at elevated sampling temperatures. Within short HSSPME sampling times and under mild sampling temperatures, Vac-HSSPME yielded linear calibration curves in the range of 1–400 ng g−1 and, with the exception of fluorene, regression coefficients were found higher than 0.99. The limits of detection for spiked sand samples ranged from 0.003 to 0.233 ng g−1 and repeatability from 4.3 to 10 %. Finally, the amount of PAHs extracted from spiked soil samples was smaller compared to spiked sand samples, confirming that soil could bind target analytes more strongly and thus decrease the readily available fraction of target analytes.  相似文献   

20.
A novel procedure was developed for the synthesis of a periodic mesoporous organosilica (PMO), which was used to remove polycyclic aromatic hydrocarbons (PAHs) from aqueous solutions. Adsorption equilibrium isotherms and adsorption kinetics experiments were carried out in solutions of PAHs (2-60 mg L(-1)), using the PMO as adsorbent. Adsorption models were used to predict the mechanisms involved. The adsorption kinetics data best fitted the pseudo-first-order kinetic model for naphthalene, and to the pseudo-second-order model for fluorene, fluoranthene, pyrene, and acenaphtene. The intraparticle model was also tested and pointed to the occurrence of such processes in all cases. The isotherm models which best represented the data obtained were the Freundlich model for fluoranthene, pyrene, and fluorene, the Temkin model for naphthalene, and the Redlich-Peterson model for acenaphtene. PAHs showed similar behavior regarding kinetics after 24 h of contact between adsorbent and PAHs. FTIR, XRD, BET, and SEM techniques were used for the characterization of the adsorbent material.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏