首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Shi J  Zhao W  Chen Y  Guo L  Yang L 《Electrophoresis》2012,33(14):2145-2151
A novel replaceable dual-enzyme capillary microreactor was developed and evaluated using magnetic fields to immobilize the alcohol dehydrogenase (ADH)- and lactate dehydrogenase (LDH)-coated magnetic beads at desired positions in the capillary. The dual-enzyme assay was achieved by measuring the two consumption peaks of the coenzyme β-nicotinamide adenine dinucleotide (NADH), which were related to the ADH reaction and LDH reaction. The dual-enzyme capillary microreactor was constructed using magnetic beads without any modification of the inner surface of the capillary, and showed great stability and reproducibility. The electrophoretic resolution for different analytes can be easily controlled by altering the relative distance of different enzyme-coated magnetic beads. The apparent K(m) values for acetaldehyde with ADH-catalyzed reaction and for pyruvate with LDH-catalyzed reaction were determined. The detection limits for acetaldehyde and pyruvate determination are 0.01 and 0.016 mM (S/N = 3), respectively. The proposed method was successfully applied to simultaneously determine the acetaldehyde and pyruvate contents in beer samples. The results indicated that combing magnetic beads with CE is of great value to perform replaceable and controllable multienzyme capillary microreactor for investigation of a series of enzyme reactions and determination of multisubstrates.  相似文献   

2.
Tang Z  Wang T  Kang J 《Electrophoresis》2007,28(17):2981-2987
A method for creating an immobilized capillary acetylcholinesterase (AChE) reactor based on a layer-by-layer (LBL) assembly for inhibitor screening is described. The unique capillary AChE reactor was easily prepared by the instrument in three steps: first, a 0.5 cm long plug of a solution of the cationic polyelectrolyte polydiallyldimethylammonium (PDDA) was injected into the capillary to produce a positively charged coating on the surface of the capillary; subsequently, the enzyme solution with the same plug length was injected into the capillary and incubated for 10 min to immobilize the enzyme on the capillary wall via electrostatic interaction; third, PDDA solution with the same plug length was injected again into the capillary to cover the immobilized enzyme by forming PDDA-AChE-PDDA sandwich-like structure. The enzyme reactor can be easily renewed after removing the immobilized enzyme by flushing the column with 1 M NaCl solution. Activity of the immobilized enzyme can be assayed simply by carrying out an electrophoretic separation, i.e., the substrate solution was injected and incubated for a short time, followed by applying a voltage to separate the product from the unreacted substrate. The measured peak area of the product then represented the enzyme activity. For enzyme inhibitor screening, the mixture solution of the substrate and the inhibitor was injected and assayed the reduction of the enzyme activity. The immobilized enzyme could withstand 100 consecutive assays by only losing 10% activity. The reproducibility in terms of time-to-time, day-to-day, and batch-to-batch was measured with RSD% less than 4.7%. Furthermore, the screening system was validated by a known inhibitor. Finally, screening a small compound library containing four known AChE inhibitors and 42 natural extracts was demonstrated, and species with inhibition activity can be straightforwardly identified with the system.  相似文献   

3.
Kaneta T  Inoue J  Koizumi M  Imasaka T 《Electrophoresis》2006,27(16):3218-3223
A method for capturing specific molecules separated by CE has been explored. To demonstrate on-column capture of migrating analyte molecules, two detection windows were fabricated on a capillary. Magnetic beads containing immobilized molecules that react with the specific molecules under study were placed between the detection windows in the capillary using magnets. Molecules in a sample solution injected into the capillary were separated and detected at the first detection window. After passing through the first detection window, the separated molecules encountered the magnetic beads, where the specific analyte was captured. As a result, the peak area for those analyte molecules decreased or disappeared completely at the second detection window. Rabbit IgG and carbonic anhydrase were employed to demonstrate on-column capture of a specific molecule. For rabbit IgG, magnetic beads containing the immobilized antibody (anti-rabbit IgG) were used. Rabbit IgG molecules were captured on the magnetic beads during CE migration. Furthermore, the capture of carbonic anhydrase was demonstrated by the reaction between magnetic beads (containing immobilized anti-rabbit IgG) and anti-carbonic anhydrase (rabbit IgG), before the beads were packed in the capillary. After packing the magnetic beads in the capillary, a mixture of two proteins was injected into the capillary. Two proteins were detected at the first detection window, while the peak corresponding to carbonic anhydrase disappeared at the second detection window. The results show that using an appropriate antibody, the present technique would be applicable to any proteins.  相似文献   

4.
The application of chemometric techniques to the resolution of overlapped peaks in capillary electrophoresis (CE) is described. When a physical separation can not be completely accomplished, chemometrics might still resolve the determination of the analytes mathematically. CE with diode array detection can provide a large amount of data consisting of spectra registered over time. In this study, the capillary electrophoretic separation of 1,2-naphthoquinone-4-sulfonate derivatives of amino acids is studied. Most of the common amino acid derivatives can be separated at 30 kV in a fused-silica capillary by using a 40 mM sodium tetraborate + isopropanol (3:1 v/v) solution as background electrolyte. However, peaks of certain derivatives (Phe, His, Leu and Ile) still overlap. A multivariate curve resolution method based on an alternating least squares optimization procedure is used for the resolution of the overlapped electrophoretic peaks. The method takes advantage of spectral and electrophoretic differences of analytes to recover their pure electrophoretic and spectral profiles. In addition, each analyte in the mixture can be quantified using the corresponding standards.  相似文献   

5.
Twenty underivatized essential amino acids were separated using capillary zone electrophoresis and consequently detected with contactless conductivity detection (CCD). A simple acidic background electrolyte (BGE) containing 2.3 M acetic acid and 0.1% w/w hydroxyethylcellulose (HEC) allowed the electrophoretic separation and sensitive detection of all 20 essential amino acids in their underivatized cationic form. The addition of HEC to the BGE suppressed both, electroosmotic flow and analyte adsorption on the capillary surface resulting in an excellent migration time reproducibility and a very good analyte peak symmetry. Additionally, the HEC addition significantly reduced the noise and long-term fluctuations of the CCD baseline. The optimized electrophoretic separation method together with the CCD was proved to be a powerful technique for determination of amino acid profiles in various natural samples, like beer, yeast, urine, saliva, and herb extracts.  相似文献   

6.
A new capillary zone electrophoretic method has been developed for the enantiomeric separation and quantification of enantiomers of carnitine, D- and L-carnitine were derivatized with 9-fluorenylmethyl chloroformate in a flow system, working on-line with the capillary electrophoretic equipment. The separation was performed using a selective chiral buffer containing 2,6-dimethyl-beta-cyclodextrin (heptakis). Triethanolamine was used as electroosmotic modifier and the separation was carried out in a uncoated capillary. Under the optimal conditions the resolution between D- and L-carnitine was 1.2 and the limits of detection for both isomers were about 5.0 microM. The proposed method was applied to the determination of D-carnitine in excess of L-carnitine in synthetic samples, and the results demonstrated that the maximal D-:L-carnitine ratio determined was approximately 1:100.  相似文献   

7.
Yang L  Chen C  Chen Y  Shi J  Liu S  Guo L  Xu H 《Analytica chimica acta》2010,683(1):136-142
A novel method for monitoring of enzyme reaction and inhibition with high temporal resolution was developed by using optically gated vacancy capillary electrophoresis (OGVCE) with laser-induced fluorescence (LIF) detection and immobilized enzyme. Trypsin cleavage reaction and inhibition were investigated by the presented OGVCE-LIF assay, using carboxyfluorescein (FAM) end-labeled Angiotensin as the substrate and commercially available immobilized trypsin. The substrate and the product were continuously loaded into the capillary by the electroosmotic flow while the immobilized enzyme remained in the sample vial. Substrate consumption and product formation were monitored simultaneously at 5 s interval during the whole reaction time. The enzymatic reaction rates obtained from the substrate and the product were highly consistent. The enzyme activity and the Michaelis constants of trypsin cleavage reaction, as well as the inhibition constant (for reversible competitive inhibitor) and the inhibition fraction (for irreversible inhibitor), were obtained. It was showed that the reported OGVCE-LIF method can perform fast, accurate, sensitive and reproducible CE enzyme assay with high temporal resolution, thus has great potential in application of the enzyme-substrate systems with fast reaction rate and the fluorescent substrate and products.  相似文献   

8.
Xiaowen Ji 《Talanta》2010,82(4):1170-231
A novel strategy for the preparation of in-column adenosine deaminase (ADA) microreactor and rapid screening of enzyme inhibitors in natural extracts was demonstrated. In this approach, ADA was encapsulated in anionic polyelectrolyte alginate that was immobilized on the surface of fused-silica capillary via ionic binding technique with cationic polyelectrolyte polyethylenimine (PEI). On-line enzyme inhibition study was performed by capillary electrophoresis (CE). The substrate and product were baselined separated within 75 s. The enzyme activity was determined by the quantification of peak area of the product. Enzyme inhibition can be read out directly from the reduced peak area of the product in comparison with a reference electropherogram obtained in the absence of any inhibitor. The inhibition percentage was used to evaluate relative activity of ADA microreactor. A known ADA inhibitor, erythro-9-(2-hydroxy-3-nonyl) adenine (EHNA) was employed as a model compound for the validation of the inhibitor screening method, and the screening of ADA inhibitor in 19 traditional Chinese herbal medicines was performed.  相似文献   

9.
One of the problems with capillary electrophoresis is a lack of versatility regarding manipulation of the separation selectivity. A new and potentially universal concept is to introduce an ion-exchange component into a separation so that the migration of analyte ions is influenced by both their electrophoretic mobilities and their chromatographic properties. This may be accomplished by use of capillaries filled with or coated with solid ion-exchange polymers, or by addition of a soluble ionic polymer to the background electrolyte to create a pseudo-stationary phase. While each of these methods achieves the same result, they are not competitive, but rather complementary as the problems associated by one approach are overcome by the others. Recent highlights in the field are used to illustrate the flexibility that this approach provides to electrophoretic separation of ions.  相似文献   

10.
Liu Z  Pawliszyn J 《The Analyst》2006,131(4):522-528
On-line coupling of solid phase microextraction (SPME) and capillary electrophoresis (CE) is highly desirable due to the apparent advantages of the two techniques particularly in the context of microanalysis. However, the hyphenation is a significant challenge, because of band broadening and analyte carryover caused by the slow kinetics of analyte desorption in liquid phase. A novel strategy was presented in this study to overcome these problems. Analytes desorbed from an SPME fiber, which was held by an adapter, were first transferred by electrophoretic migration into a short piece of microdialysis hollow fiber, which was located at the inlet of a CE system. Analytes with molecular weights greater than the molecular weight cut-off of the microdialysis material were trapped in the microdialysis hollow fiber due to the dialysis effect. Then, under another electric field with different electrode polarity, the analytes trapped in the microdialysis hollow fiber migrated into the separation capillary and were separated. In the coupling approach, the microdialysis hollow fiber functioned as a macromolecule trap and a sample pre-concentrator as well. Band broadening was eliminated because the initial sample volume was very small (at nL level). Meanwhile, analyte carryover was eliminated because the desorption time could be as long as needed. Coupling of SPME with CE including two modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), was successfully demonstrated with proteins as test analytes. High efficiency and high resolution were obtained. The detection limits with UV absorbance whole-column imaging detection were 3.0 x 10(-7) and 3.0 x 10(-8) M (S/N = 3) for beta-lactoglobulin A and ovalbumin, respectively.  相似文献   

11.
Heegaard NH  Kennedy RT 《Electrophoresis》1999,20(15-16):3122-3133
The high resolving power of capillary electrophoresis combined with the specificity of binding interactions may be used with advantage to characterize the structure-function relationship of biomolecules, to quantitate specific analytes in complex sample matrices, and to determine the purity of pharmaceutical and other molecules. We here review recent and innovative methodologies and applications of high resolution affinity electrophoresis within the fields of binding constant determination, structure-activity studies, quantitative microassays, analysis of drug purity and protein conformation, and immobilized affinity ligands. Despite the virtues of these approaches with respect to applicability, resolving power, speed, and low sample consumption, problems remain with respect to analyte identification and low concentration limits of detection. The ongoing development of new detector technologies for capillary electrophoresis such as mass spectrometry, and possibly nuclear magnetic resonance and other spectroscopic methods, is therefore very promising for the continued increased use of affinity capillary electrophoresis.  相似文献   

12.
CE was used for the first time to study the two‐substrate enzyme glycerol kinase. The capillary was used as a nanoreactor in which the enzyme and its two substrates glycerol and adenosine‐5′‐triphosphate were in‐capillary mixed to realize the enzymatic assay. For kinetic parameters determination, reactants were injected (50 mbar × 5 s) as follows: (i) incubation buffer; (ii) adenosine‐5′‐triphosphate; (iii) enzyme, and (iv) glycerol. Enzymatic reaction was then initiated by mixing the reactants using electrophoretically mediated microanalysis (+20 kV for 6 s) followed by a zero‐potential amplification step of 3 min. Finally, electrophoretic separation was performed; the product adenosine‐5′‐diphosphate was detected at 254 nm and quantified. For enzyme inhibition, an allosteric inhibitor fructose‐1,6‐bisphosphate plug was injected before the first substrate plug and +20 kV for 8 s was applied for reactant mixing. A simple, economic, and robust CE method was developed for monitoring glycerol kinase activity and inhibition. Only a few tens of nanoliters of reactants were used. The results compared well with those reported in literature. This study indicates, for the first time, that at least four reactant plugs can be in‐capillary mixed using an electrophoretically mediated microanalysis approach.  相似文献   

13.
This review gives a survey of selectivity modes in capillary electrophoresis separations in pharmaceutical analysis and bioanalysis. Despite the high efficiencies of these separation techniques, good selectivity is required to allow quantitation or identification of a particular analyte. Selectivity in capillary electrophoresis is defined and described for different separation mechanisms, which are divided into two major areas: (i) capillary zone electrophoresis and (ii) electrokinetic chromatography. The first area describes aqueous (with or without organic modifiers) and nonaqueous modes. The second area discusses all capillary electrophoretic separation modes in which interaction with a (pseudo)stationary phase results in a change in migration rate of the analytes. These can be divided in micellar electrokinetic chromatography and capillary electrochromatography. The latter category can range from fully packed capillaries, via open-tubular coated capillaries to the addition of microparticles with multiple or single binding sites. Furthermore, an attempt is made to differentiate between methods in which molecular recognition plays a predominant role and methods in which the selectivity depends on overall differences in physicochemical properties between the analytes. The calculation of the resolution for the different separation modes and the requirements for qualitative and quantitative analysis are discussed. It is anticipated that selectivity tuning is easier in separation modes in which molecular recognition plays a role. However, sufficient attention needs to be paid to the efficiency of the system in that it not only affects resolution but also detectability of the analyte of interest.  相似文献   

14.
A theoretical model to explain the observed mobility of inorganic anions in capillary electrochromatography (CEC) using ion-exchange (IE) stationary phases has been derived. The model divides contributions to the observed mobility of an analyte ion into capillary electrophoretic (CE) and IE components. The CE component includes the influence of varying the ionic strength of the background electrolyte on the electrophoretic mobility of the analyte, while the IE component accounts for the variation in retention of the analyte ion caused by changing the composition of the background electrolyte. The model was verified using a mixture of UV-absorbing inorganic ions in electrolytes of differing eluotropic strength in both packed and open-tubular CEC systems, with excellent agreement (r2 > 0.98) for both systems. Values of constants in the model equation determined by nonlinear regression were used to estimate the relative strengths of the interactions of different analytes with the stationary phase and these were found to agree well with elution orders observed in conventional IE chromatography.  相似文献   

15.
田苗苗  杨丽 《色谱》2020,38(10):1143-1153
毛细管电泳技术具有操作简单、样品消耗量少、分离效率高和分析速度快等优势,不仅是一种高效的分离分析技术,而且已经发展成为在线酶分析和酶抑制研究的强有力工具。酶反应全程的实时在线监测,可以实现酶反应动力学过程的高时间分辨精确检测,以更准确地获得反应机制和反应速率常数,有助于更好地了解酶反应机制,从而更全面深入地认识酶在生物代谢中的功能。此外,准确、快速的在线酶抑制剂高通量筛选方法的发展,对加快酶抑制类药物的研发以及疾病的临床诊断亦具有重要意义。电泳媒介微分析法(EMMA)和固定化酶微反应器(IMER)是毛细管电泳酶分析技术中常用的在线分析方法。这两种在线酶分析法的进样方式通常为流体动力学进样和电动进样,无法实现酶反应过程中的无干扰序列进样分析。近年来,基于快速序列进样的毛细管电泳序列分析技术已经发展成为在线酶分析的另一种强有力手段,以实现高时间分辨和高通量的酶分析在线检测。该文从快速序列进样的角度,综述了近年来毛细管电泳序列分析技术在线酶分析的研究进展,并着重介绍了各种序列进样方法及其在酶反应和酶抑制反应中的应用,包括光快门进样、流动门进样、毛细管对接的二维扩散进样、流动注射进样、液滴微流控进样等。  相似文献   

16.
CZE was assayed for the separation of carbamate pesticides susceptible to protonation (Pirimicarb, Carbendazim). Different electrophoretic media with high organic contents were explored, adequate separation and resolution being achieved when a BGE based on ACN with acetic acid in the presence of SDS as an ionic additive was used. With a view to increasing the sensitivity of the method, an in-capillary SPE step prior to the electrophoretic separation was developed. We employed a monolithic polymer formed in situ within the capillary as a medium for analyte retention. The synthesized monolithic bed exhibited high porosity and allowed samples to be loaded at flow rates of about 65 microL/min by applying a pressure of 12 bar. A 5-cm length of monolithic sorbent was used to preconcentrate the target analytes from aqueous samples. The analytes retained were eluted from the polymeric phase directly in the separation capillary with the same electrophoretic medium used for their further separation by CZE. For a 15-min preconcentration time, the in-line SPE-CZE approach proposed here permitted the determination of these pesticides in drinking water at a concentration level of 0.1 microg/L, as demanded by current EU legislation.  相似文献   

17.
Cationic polyelectrolyte of chitosan was used for the reversal of electroosmotic flow in capillary zone electrophoresis. The chitosan was dissolved in acetic acid solution, and stable electroosmotic flow was obtained at the chitosan concentrations between 50 and 300 microg/mL. Separation of inorganic anions was carried out using the dynamically coated capillary by capillary zone electrophoresis. Nine kinds of anions were separated and detected with the capillary. The electrophoretic mobility of the analyte anions decreased with increasing concentrations of chitosan in the migrating solution through ion-ion interaction, but the migration order of the analyte anions was not changed in the concentration range of the chitosan examined. The signal shape for the analyte anions was developed by using field-enhanced sample stacking with 10 mM sodium sulfate.  相似文献   

18.
This paper describes an ultramicro method for achieving enzyme assays. Enzyme saturating concentrations of substrate, coenzyme when appropriate, and running buffer were mixed and used to fill a deactivated fused-silica capillary in a capillary zone electrophoresis apparatus. The enzyme glucose-6-phosphate dehydrogenase was injected by either electrophoresis or siphoning and mixed with the reagents in the capillary by electrophoretic mixing. Enzyme activity was assayed by electrophoresing the product, reduced nicotinamide adenine dinucleotide phosphate, to the detector where it was detected at 340 nm. Under constant potential, the transport velocity of enzyme and the product was generally different. This caused product to be separated from the enzyme after it was formed. Because product formation was much faster than the rate of enzyme-product separation, product accumulated. The amount of accumulated product was inversely related to operating potential. In the extreme case, the operating potential was zero. Zero potential assays were generally carried out by electrophoresing the enzyme partially through the capillary and then switching to zero potential. This capillary was left at zero potential for several minutes to allow additional product to accumulate. After this additional amplification step, potential was again applied and the product transported to the detector. Product formed under constant potential appears as a broad peak with a flat plateau. When the voltage is switched to zero at intermediate migration distance, a peak will be observed on top of this plateau. Either the eight of the plateau or the area of the peak may be used to determine enzyme concentration. The lower limit of detection was 4.6.10(-17) mol of glucose-6-phosphate dehydrogenase.  相似文献   

19.
A new approach to non-aqueous capillary electrophoresis based on the addition of anionic carboxylic surfactants to the basic amphiprotic organic solvent in which form neutral-surfactant aggregates was developed with a view to improving the electrophoretic resolution of charged substances. These aggregates acts as a new pseudostationary phase. The presence of these aggregates allows the effective separation of four tetracyclines with increased selectivity. The efficiency of sodium caprylate, sodium laurate and sodium palmitate as surfactants was examined. The latter two proved more effective than the former as they provided migration times reproducible to within 7% or better in all cases. The additional use of an alcohol allows peak shape to be controlled, which expands the potential of this electrophoretic technique even further. The proposed method was used to determine tetracyclines in water samples. The sensitivity of the determination was improved by using a flow manifold coupled at-line to the capillary electrophoresis system in order to preconcentrate the analytes. The limits of detection thus achieved ranged from 50 to 90 μg/l. Under optimal operating conditions, recoveries ranged from 97 to 104%, and precision from 5.4 to 7.0%.  相似文献   

20.
Zhou H  Holland LA  Liu P 《The Analyst》2001,126(8):1252-1256
Amperometric reaction detection of model peptides containing either a thiol or disulfide was successfully achieved with a novel coupled capillary liquid chromatography-dual microelectrode system. Detection is facilitated via dual platinum wire electrodes fabricated directly on a liquid chromatography capillary column. The detection strategy is based on the electrogeneration of bromine at the upstream working electrode followed by reduction of the bromine to bromide at the downstream working electrode. When bromine reacts with analyte eluting from the capillary column, the amount of bromine that reaches the downstream electrode decreases. As a result, the current at the downstream electrode will decrease in proportion to the amount of analyte eluting from the capillary column. Glutathione, glutathione disulfide, alpha-TGF and oxytocin were used to characterize the system and to determine system parameters. The feasibility of the determination of disulfide containing peptides is demonstrated with glutathione disulfide, alpha-TGF and oxytocin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号