首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
A novel test has been developed for the analysis of methadone in dried blood spot specimens from patients undergoing methadone maintenance treatment. An isocratic reversed-phase high-performance liquid chromatography method with coulometric detection has been optimized for the determination of methadone. The clean-up of dried blood spots was performed by means of an original microextraction by packed sorbent procedure after microwave-assisted extraction of the drug with a suitable solvent. Extraction yields were satisfactory, always being higher than 90.0 %. The calibration curve was linear over the 4–500 ng mL-1 concentration range. The method had satisfactory sensitivity (limit of quantitation of 4 ng mL-1), precision (relative standard deviation less than 5.8 %), selectivity and accuracy (recovery greater than 87.0 %). It was successfully applied to dried blood spot samples collected from heroin-addicted patients undergoing methadone maintenance therapy at dosages between 40 and 240 mg day-1. The statistical analysis (Bland–Altman plot) showed that the results were in good agreement with those found from the analysis of plasma samples obtained from the same patients. Thus, the method has proved to be suitable for the monitoring of methadone by means of dried blood spots.
Figure
Bland-Altman plot and methadone disposition in patients undergoing methadone maintenance treatment  相似文献   

2.
Microextraction by packed sorbents (MEPS) combined with Surface-enhanced Raman spectroscopy (SERS) was investigated, and applied to the determination of musk ketone (MK) in river water samples. The full MEPS–SERS method includes analyte enrichment by MEPS preconcentration with C18 sorbent followed by SERS detection supported by silver nanoparticles. An eluent drop containing the analyte is deposited directly from the MEPS syringe on a CaF2 glass plate. When the drop has dried, a specific volume of silver nanoparticles solution is added on it before each SERS measurement. Several experimental variables were studied in depth; under the optimum experimental conditions MK can be extracted from a 500 μL sample with recoveries in the range 47–63 %. The limit of detection was 0.02 mg L?1 and the relative standard deviation 15.2 % (n?=?4). Although not investigated in this work, the proposed method might be suitable for in-situ monitoring, because of the portability of the Raman spectrometer used.
Figure
Experimental scheme of the MEPS-SERS method proposed for the determination of musk ketone in river water  相似文献   

3.
Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %–92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.
Figure
?  相似文献   

4.
Ionic liquids have attracted much attention in the analysis of a variety of species. The functional groups in ionic liquids can result in highly efficient separation and enrichment and, because of their typical lack of volatility, they are environmentally benign. We grafted imidazole cations onto the surface of chloromethyl polystyrene, denoted PS-CH2-[MIM]+Cl?, and this modified polymer was used to selectively extract the protein hemoglobin (Hb). The prepared extractant PS-CH2-[MIM]+Cl?, containing 2 mmol immobilized imidazole groups per gram polymer, was characterized by FT-IR, surface charge analysis, and elemental analysis. The adsorption efficiency was 91 %. The adsorption capacity of the PS-CH2-[MIM]+Cl? for Hb was 23.6 μg mg?1, and 80 % of the retained Hb could be readily recovered by use of 0.5 % (m/v) aqueous sodium dodecyl sulfate (SDS) solution as eluate. The activity of the eluted Hb was approximately 90 %. The prepared imidazole-containing solid phase polymer was used for direct adsorption of Hb without use of any other solid matrix as support of the ionic liquid. The material was used in practice to isolate Hb from human whole blood.
Figure
Coordination interaction between heme of hemoglobin and imidazolium-modified chloromethyl polystyrene.  相似文献   

5.
Solid-phase microextraction (SPME) based on carboxylated single-walled carbon nanotube fibers was used to extract several chlorophenols (CPs) and organochlorine pesticides (OCPs) from aqueous samples prior to their determination by GC with electron capture detection. The main parameters affecting microextraction (temperature, time, stirring rate and salting-out effect) and the conditions of the thermal desorption in the GC injector were optimized. Compared with commercial SPME fibers, the fiber presented better selectivity and sensitivity. Linear response was found for the concentration range between 2 and 1000 ng L?1 (20–1000 ng L?1 for CPs), and the limits of detection were in the range from 0.07 to 4.36 ng L?1. The repeatability expressed as relative standard deviation ranged from 4.1 % to 8.2 % and the fiber-to-fiber reproducibility for four prepared fibers was between 6.5 % and 10.8 %. The method was successfully applied to the analysis of CPs and OCPs in lake water and waste water samples. Recovery was tested with spiked lake water and waste water samples, with values ranging from 89.7 % to 101.2 % in case of waste water samples.
Figure
Raman spectra: (A) SWNTs, and (B) Oxidized SWNTs  相似文献   

6.
The segregation in dried droplet MALDI sample spots was analyzed with regard to the matrix-to-sample ratio using optical microscopy, MALDI imaging mass spectrometry (MALDI MSI) and IR imaging spectroscopy. In this context, different polymer/matrix/solvent systems usually applied in the analysis of synthetic polymers were investigated. The use of typical matrix concentrations (10 mg mL?1) in almost every case resulted in ring patterns, whereas higher concentrated matrix solutions always led to homogeneous sample spot layers. The data revealed that segregation is predominantly caused by matrix transport in the drying droplet, whereas polymer segregation seems to be only secondary.
Figure
?  相似文献   

7.
We report on a microfluidic platform that integrates a winding microdroplet chip and a surface-enhanced Raman scattering (SERS) detection system for trace determination of crystal violet (CV). Colloidal silver was applied to generate SERS. Compared to the continuous flow microfluidic system, the microdroplet based detection described here effectively eliminates any memory effects. Effects of flow pattern, droplet size, surfactant, and position of detection were optimized. Under optimal conditions, there is a linear correlation between signal and the concentration of CV in the 10 nM to 800 nM range, with a correlation coefficient (R2) of 0.9967. The limit of detection in water is 3.6 nM.
Graph
A winding microdroplet chip based on SERS detection was developed for trace levels of crystal violet. Under optimal conditions,there is a good linear correlation in the 10 nM to 800 nM range with LOD is 3.6 nM.  相似文献   

8.
The fluorescence quenching of quantum dots by hemoglobin has been demonstrated to depend on surface functionalization, and this property has been utilized to construct a novel fluorescent method for rapid, sensitive, and selective detection of trace hemoglobin in urine at microgram level. This method shows low interference and high selectivity for hemoglobin with a limit of detection of 4.3 μg L?1 in water and 66.1 μg L?1 in urine, which are lower than those of currently used methods in labs and clinics. Spike and recovery tests in raw, acidified, and alkalized urine samples exhibit good recovery rates for the spiked concentrations close to the limit of detection.
Figure
Fluorescence spectra and photographs of MPA-QD solution before and after the addition of Hb taken under 365-nm irradiation.  相似文献   

9.
A simple and sensitive method, based on surface-enhanced Raman scattering (SERS), for immunoassay and label-free protein detection is reported. A series of bowl-shaped silver cavity arrays were fabricated by electrodeposition using a self-assembled polystyrene spheres template. The reflection spectra of these cavity arrays were recorded as a function of film thickness, and then correlated with SERS enhancement using sodium thiophenolate as the probe molecule. The results reveal that SERS enhancement can be maximized when the frequency of both the incident laser and the Raman scattering approach the frequency of the localized surface plasmon resonance. The optimized array was then used as the bottom layer of a silver nanoparticle–protein–bowl-shaped silver cavity array sandwich. The second layer of silver was introduced by the interactions between the proteins in the middle layer of the sandwich architecture and silver nanoparticles. Human IgG bound to the surface of this microcavity array can retain its recognition function. With the Raman reporter molecules labeled on the antibody, a detection limit down to 0.1 ng mL?1 for human IgG is easily achieved. Furthermore, the SERS spectra of label-free proteins (catalase, cytochrome C, avidin and lysozyme) from the assembled sandwich have excellent reproducibility and high quality. The results reveal that the proposed approach has potential for use in qualitative and quantitative detection of biomolecules.
Schematic diagram of sandwich structure for labelled and label-free protein detection.  相似文献   

10.
We describe the use of individual zinc oxide (ZnO) micro/nanowires in an electrochemical biosensor for uric acid. The wires were synthesized by chemical vapor deposition and possess uniform morphology and high crystallinity as revealed by scanning electron microscopy, X-ray diffraction, and photoluminescence studies. The enzyme uricase was then immobilized on the surface of the ZnO micro/nanowires by physical adsorption, and this was proven by Raman spectroscopy and fluorescence microscopy. The resulting uric acid biosensor undergoes fast electron transfer between the active site of the enzyme and the surface of the electrode. It displays high sensitivity (89.74 μA cm?2 mM?1) and a wide linear analytical range (between 0.1 mM and 0.59 mM concentrations of uric acid). This study also demonstrates the potential of the use of individual ZnO micro/nanowires for the construction of highly sensitive nano-sized biosensors.
Figure
Individual ZnO micro/nanowire based electrochemical biosensor was constructed. The biosensor displayed a higher sensitivity of 89.74 μA cm?2 mM?1 for uric acid detection.  相似文献   

11.
We present for the first time the Raman microspectroscopic identification and characterization of individual airborne volcanic ash (VA) particles. The particles were collected in April/May 2010 during research aircraft flights, which were performed by Deutsches Zentrum für Luft- und Raumfahrt in the airspace near the Eyjafjallajökull volcano eruption and over Europe (between Iceland and Southern Germany). In addition, aerosol particles were sampled by an Electrical Low Pressure Impactor in Munich, Germany. As references for the Raman analysis, we used the spectra of VA collected at the ground near the place of eruption, of mineral basaltic rock, and of different minerals from a database. We found significant differences in the spectra of VA and other aerosol particles (e.g., soot, nitrates, sulfates, and clay minerals), which allowed us to identify VA among other atmospheric particulate matter. Furthermore, while the airborne VA shows a characteristic Raman pattern (with broad band from ca. 200 to ca. 700 cm?1 typical for SiO2 glasses and additional bands of ferric minerals), the differences between the spectra of aged and fresh particles were observed, suggesting differences in their chemical composition and/or structure. We also analyzed similarities between Eyjafjallajökull VA particles collected at different sampling sites and compared the particles with a large variety of glassy and crystalline minerals. This was done by applying cluster analysis, in order to get information on the composition and structure of volcanic ash.
Figure
Images and Raman spectra of airborne volcanic ash  相似文献   

12.
In general, classification-based methods based on confocal Raman microscopy are focused on targeted studies under which the spectral libraries are collected under controlled instrument parameters, which facilitate analyses via standard multivariate data analysis methods and cross-validation. We develop and compare approaches to transform spectra collected at different spectral ranges and varying levels of resolution into a single lower-dimension spectral signature library. This will result in a more robust analysis method able to accommodate spectra accumulated at different times and conditions. We demonstrate these approaches on a relevant test case; the identification of microbial species from a natural environment. The training data were based on samples prepared for three unique species collected at two time points and the test data consisted of blinded unknowns prepared and analyzed at a later date with different instrument parameters. The results indicate that using reduced dimension representations of the spectral signatures improves classification accuracy over basic alignment protocols. In particular, utilizing the microbial species partial least squares discriminant analysis classifier on the blinded samples based on alignment achieved ~78 % accuracy, while both binning and peak selection approaches yielded 100 % accuracy.
Figure
A probability heatmap associated with the identification of species di181 across 357 spectra collected from a single drop of a mixed microbial suspension, dry-mounted for Raman analysis  相似文献   

13.
We have synthesized silver nanoparticles (AgNPs) decorated with α-cyclodextrin (CD) by using the traditional silver mirror reaction in the presence of CD. The CD-AgNPs were used as substrate in surface-enhanced Raman spectroscopy (SERS) for determining melamine. The intensity of the Raman band of melamine at 704 cm?1 was used to determine melamine in milk and milk powder. The use of CD-AgNPs as the SERS substrate rather than classical silver nanoparticles makes the method more sensitive in giving an enhancement by a factor of up to?~?106 in scattering efficiency. The effects of the volume of solutions (of CD-AgNPs, NaCl, NaOH, melamine) and of mixing time were optimized. The standard addition method was employed for quantitative analysis. The correlation coefficient of the calibration plot is 0.9995, and the limit of detection is 3.0 μg L?1. The method was successfully applied to the determination of melamine in milk and milk powder, with relative standard deviations of <10 % and recoveries between 89 and 104 %.
Figure
Novel silver nanoparticles decorated with α-cyclodextrin (CD-AgNPs) were prepared. The melamine in milk and milk powder was determined using SERS and CD-AgNPs. The limit of detection is 3.0 μg L?1, and recoveries between 89 and 104 %  相似文献   

14.
The anti-schizophrenic drug risperidone (RSP) exerts an inhibitory effect on the chemiluminescence (CL) of the luminol-lysozyme system. This finding forms the basis for a sensitive flow injection method for its determination at picogram levels. RSP binds to Trp62 in the lysozyme, and this leads to a conformational change upon which the CL of the system is quenched. The decrease in CL is proportional to the logarithm of the concentration of RSP, and the calibration graph is linear in the range from 0.1 pg?mL?1 to 1.0 ng?mL?1, with relative standard deviations of <5.0%, and a detection limit of 0.05 pg?mL?1 (3σ). At a flow rate of 2.0 mL?min?1, the whole process including sampling and washing is completed within 20 s. The method was successfully applied to monitoring RSP in human urine after incorporation of 2 mg of RSP, with a total excretion of 16.6% within 8.5 h.
Figure
The reaction of lysozyme with risperidone using luminol as luminescence reagent by the luminol-lysozyme FI-CL system and its application.  相似文献   

15.
We have developed a surface-enhanced Raman scattering (SERS) probe for the determination of mercury(II) using methimazole-functionalized and cyclodextrin-coated silver nanoparticles (AgNPs). These AgNPs in pH 10 solution containing sodium chloride exhibit strong SERS at 502 cm?1. Its intensity strongly decreases in the presence of Hg(II). This effect serves as the basis for a new method for the rapid, fast and selective determination of trace Hg(II). The analytical range is from 0.50 μg L?1 to 150 μg L?1, and the limit of detection is 0.10 μg L?1. The influence of 11 metal ions commonly encountered in environmental water samples was found to be quite small. The method was applied to the determination of Hg(II) in spiked water samples and gave recoveries ranging from 98.5 to 105.2 % and with relative standard deviations of <3.5 % (n?=?5). The total analysis time is <10 min for a single sample.
Figure
A high-sensitive SERS probe for the determination of Hg2+ using methimazole-functionalized cyclodextrin-protected AgNPs was designed. The limit of detection is 0.10 μg L?1.  相似文献   

16.
A novel approach utilizing automated Raman microspectroscopic mapping for gunshot residue (GSR) detection was investigated. A well-established technique for GSR recovery (tape lifting) was utilized for GSR particle collection. Uncontaminated samples of the substrate (tape), organic GSR (OGSR), and inorganic GSR (IGSR) particles were characterized to generate three respective Raman spectroscopic training sets. Automated Raman mapping was used to rapidly collect spectra over areas of the tape substrate populated with GSR particles. Raman spectra collected from the maps were classified against the training sets via partial least squares discriminant analysis (PLS-DA) to determine if GSR was present. We report the application of Raman chemical mapping as a proof of concept for the positive detection of GSR particles of varying morphologies. The estimated size of GSR particles, which could be readily detected by this method, is about 3.4 μm. The efficiency of the classification was quantitated with rates of true positives and negatives. Validation studies scrutinizing the practicality of this approach as a viable tool for potential forensics investigations are currently in progress.
Figure
The figure illustrates a novel approach for the recovery and identification of gunshot residue on adhesive tape. The emerging approach combines tape lifting and a rapid, non-destructive Raman spectroscopic scanning over the tape, which was used for collecting GSR from a surface of interest. Detection of GSR is achieved through multivariate classification of mapping spectra against a known training set.  相似文献   

17.
Negative-ion matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectra and tandem mass spectra of flavonoid mono-O-glycosides showed the irregular signals that were 1 and/or 2 Da smaller than the parent deprotonated molecules ([M – H]) and the sugar-unit lost fragment ions ([M – Sugar – H]). The 1 and/or 2 Da mass shifts are generated with the removing of a neutral hydrogen radical (H*), and/or with the homolytic cleavage of the glycosidic bond, such as [M – H* – H], [M – Sugar – H* – H], and [M – Sugar – 2H* – H]. It was revealed that the hydrogen radical removes from the phenolic hydroxy groups on the flavonoids, not from the sugar moiety, because the flavonoid backbones themselves absorb the laser. The glycosyl positions depend on the extent of the hydrogen radical removals and that of the homolytic cleavage of the glycosidic bonds. Flavonoid mono-glycoside isomers were distinguished according to their TOF MS and tandem mass spectra.
Figure
?  相似文献   

18.
Elemental analysis of glass was conducted by 16 forensic science laboratories, providing a direct comparison between three analytical methods [micro-x-ray fluorescence spectroscopy (μ-XRF), solution analysis using inductively coupled plasma mass spectrometry (ICP-MS), and laser ablation inductively coupled plasma mass spectrometry]. Interlaboratory studies using glass standard reference materials and other glass samples were designed to (a) evaluate the analytical performance between different laboratories using the same method, (b) evaluate the analytical performance of the different methods, (c) evaluate the capabilities of the methods to correctly associate glass that originated from the same source and to correctly discriminate glass samples that do not share the same source, and (d) standardize the methods of analysis and interpretation of results. Reference materials NIST 612, NIST 1831, FGS 1, and FGS 2 were employed to cross-validate these sensitive techniques and to optimize and standardize the analytical protocols. The resulting figures of merit for the ICP-MS methods include repeatability better than 5 % RSD, reproducibility between laboratories better than 10 % RSD, bias better than 10 %, and limits of detection between 0.03 and 9 μg g?1 for the majority of the elements monitored. The figures of merit for the μ-XRF methods include repeatability better than 11 % RSD, reproducibility between laboratories after normalization of the data better than 16 % RSD, and limits of detection between 5.8 and 7,400 μg g?1. The results from this study also compare the analytical performance of different forensic science laboratories conducting elemental analysis of glass evidence fragments using the three analytical methods.
Figure
?  相似文献   

19.
We have developed a lactate biosensor based on a bionanocomposite (BNC) composed of titanium dioxide nanoparticles (TiO2-NPs), photocatalytically reduced graphene, and lactate oxidase. Graphene oxide was photochemically reduced (without using any chemical reagents) in the presence of TiO2-NPs to give graphene nanosheets that were characterized by atomic force microscopy, Raman and X-ray photoelectron spectroscopy. The results show the nanosheets to possess few oxygen functionalities only and to be decorated with TiO2-NPs. These nanosheets typically are at least 1 μm long and have a thickness of 4.2 nm. A BNC was obtained by mixing lactate oxidase with the nanosheets and immobilized on the surface of a glassy carbon electrode. The resulting biosensor was applied to the determination of lactate. Compared to a sensor without TiO2-NPs, the sensor exhibits higher sensitivity (6.0 μA mM?1), a better detection limit (0.6 μM), a wider linear response (2.0 μM to 0.40 mM), and better reproducibility (3.2 %).
?  相似文献   

20.
We report on a facile immunoassay for porcine circovirus type 2 (PCV2) based on surface enhanced Raman scattering (SERS) using multi-branched gold nanoparticles (mb-AuNPs) as substrates. The mb-AuNPs in the immunosensor act as Raman reporters and were prepared via Tris base-induced reduction and subsequent reaction with p-mercaptobenzoic acid (pMBA). They possess good stability and high SERS activity. Subsequently, the modified mb-AuNPs were covalently conjugated to the monoclonal antibody (McAb) against the PCV2 cap protein to form SERS immuno nanoprobes. These were captured in a microtiterplate via a immunoreaction in the presence of target antigens. The effects of antibody concentration, reaction time and temperature on the sensitivity of the immunoassay were investigated. Under optimized assay conditions, the Raman signal intensity at 1,076 cm?1 increases logarithmically with the concentrations of PCV2 in the concentration ranging from 8?×?102 to 8?×?106 copies per mL. The limit of detection is 8?×?102 copies per mL. Compared to conventional detecting methods such as those based on PCR, the method presented here is rapid, facile and very sensitive.
Figure
A simple and novel approach to detect porcine circovirus type 2 using surface enhanced Raman scattering (SERS) of multi-branched gold nanoparticles is demonstrated, it has a higher sensitivity than polymerase chain reaction and ELISA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号