首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Atmospheric pressure laser desorption/ionization on porous silicon   总被引:3,自引:0,他引:3  
A recently developed commercial atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) source (MassTech, Inc.) was modified to adopt commercially available DIOS plates (Mass Consortium Corp.) for the studies of laser desorption from the surface of porous silicon under atmospheric pressure conditions. The feasibility of atmospheric pressure laser desorption/ionization from the surface of porous silicon (AP-DIOS) was demonstrated. The advantages of this new AP-DIOS technique include reasonably good sensitivity (subpicomole range for standard peptide mixtures), simplicity of sample preparation, uniformity of target spots and the absence of matrix peaks in the spectra. The AP-DIOS source was interfaced with a commercial ion trap (LCQ Classic, Thermo Finnigan) which additionally provides a unique MS(n) capability. The AP-DIOS spectrum of 250 fmol of unseparated tryptic digest of bovine serum albumin (BSA) was compared with that of AP-MALDI for the same compound. AP-DIOS offers significantly better coverage for the digest components in the mass range 200-1000 Da. The combined data of both techniques enabled us to nearly double the number of matched peaks in BSA digest analysis compared with AP-DIOS or AP-MALDI analysis separately.  相似文献   

2.
A novel method is reported for rapid protein identification by the analysis of tryptic peptides using desorption electrospray ionisation (DESI) coupled with hyphenated ion mobility spectrometry and quadrupole time-of-flight mass spectrometry (IMS/Q-ToF-MS). Confident protein identification is demonstrated for the analysis of tryptically digested bovine serum albumin (BSA), with no sample pre-treatment or clean-up. Electrophoretic ion mobility separation of ions generated by DESI allowed examination of charge-state and mobility distributions for tryptic peptide mixtures. Selective interrogation of singly charged ions allowed isobaric peptide responses to be distinguished, along with a reduction in spectral noise. The mobility-selected singly charged peptide responses were presented as a pseudo-peptide mass fingerprint (p-PMF) for protein database searching. Comparative data are shown for electrospray ionisation (ESI) of the BSA digest, without sample clean-up, from which confident protein identification could not be made. Implications for the robustness of the DESI method, together with potential insights into mechanisms for DESI of proteolytic digests, are discussed.  相似文献   

3.
Atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) ion trap mass spectrometry (ITMS) has been evaluated for automated protein identification. By using signal averaging and long ion-injection times, protein identification limits in the 50-fmol range are achieved for standard protein digests. Data acquisition requires 7.5 min or less per sample and the MS/MS spectra files are automatically processed using the SEQUEST database searching algorithm. AP-MALDI-ITMS was compared with the widely used methods of microLC/MS/MS (ion trap) and automated MALDI-TOF peptide mass mapping. Sample throughput is 10-fold greater using AP-MALDI compared with microcapillary liquid chromatography/tandem mass spectrometry (microLC/MS/MS). The protein sequence coverage obtained from AP-MALDI-MS/MS spectra matched by SEQUEST is lower compared with microLC/MS/MS and MALDI-TOF mass mapping. However, by using the AP-MALDI full-scan peptide mass fingerprint spectrum, sequence coverage is increased. AP-MALDI-ITMS was applied for the analysis of Coomassie blue stained gels and was found to be a useful platform for rapid protein identification.  相似文献   

4.
The highly selective capture of phosphopeptides from proteolytic digests is a great challenge for the identification of phosphoproteins by mass spectrometry. In this work, the zirconium phosphonate-modified magnetic Fe3O4/SiO2 core/shell nanoparticles have been synthesized and successfully applied for the selective capture of phosphopeptides from complex tryptic digests of proteins before the analysis of MALDI-TOF mass spectrometry with the desired convenience of sample handling. The ratio of magnetic nanoparticle to protein and the incubation time for capturing phosphopeptides from complex proteolytic digests were investigated, and the optimized nanoparticle-to-protein ratio and incubation time were between 15:1 to 30:1 and 30 min, respectively. The excellent detection limit of 0.5 fmol β-casein has been achieved by MALDI-TOF mass spectrometry with the specific capture of zirconium phosphonate-modified magnetic Fe3O4 nanoparticles. The great specificity of zirconium phosphonate-modified magnetic Fe3O4 nanoparticles to phosphopeptides was demonstrated by the selective capture of phosphopeptides from a complex tryptic digest of the mixture of α-casein and bovine serum albumin at molar ratio of 1 to 100 in MALDI-TOF-MS analysis. An application of the magnetic nanoparticles to selective capture phosphopeptides from a tryptic digest of mouse liver lysate was further carried out by combining with nano-LC-MS/MS and MS/MS/MS analyses, and a total of 194 unique phosphopeptides were successfully identified.  相似文献   

5.
利用羟丙基纤维素溶液动态涂层技术修饰毛细管管壁,改善了分离效率.在不影响质谱检测的条件下,将动态涂层毛细管电泳与质谱检测联用,有效地提高了对蛋白质的鉴定能力.将该技术应用于对复杂蛋白质样品的酶解产物的分析鉴定,结果令人满意.  相似文献   

6.
米薇  王晶  应万涛  贾伟  蔡耘  钱小红 《色谱》2010,28(2):108-114
多维色谱分离、串联质谱分析技术已在蛋白质组研究中得到广泛应用。然而生物样品的蛋白质以及全酶切肽段具有高度的复杂性,这严重干扰了蛋白质高通量、规模化的分析。通过标签肽段富集进行样品预分离可以降低体系的复杂程度。本文建立了一种基于共价色谱技术选择性分离富集含半胱氨酸肽的方法,从而降低了样品体系的复杂程度。首先以牛血清白蛋白(BSA)的酶切肽段为模型,对富集条件进行了优化和考察,并在此基础上通过5种蛋白质酶切肽段混合物的富集对该方法进行了验证。结果证明此方法的重现性好,富集效率高,富集特异性好,能有效地富集鉴定含半胱氨酸肽段。所建立的方法在复杂体系的蛋白质组研究中具有广泛的应用前景,为复杂样品的蛋白质高通量、自动化、规模化鉴定和定量研究提供了实用技术。  相似文献   

7.
We have constructed an electrospray-assisted laser desorption/ionization (ELDI) source which utilizes a nitrogen laser pulse to desorb intact molecules from matrix-containing sample solution droplets, followed by electrospray ionization (ESI) post-ionization. The ELDI source is coupled to a quadrupole ion trap mass spectrometer and allows sampling under ambient conditions. Preliminary data showed that ELDI produces ESI-like multiply charged peptides and proteins up to 29 kDa carbonic anhydrase and 66 kDa bovine albumin from single-protein solutions, as well as from complex digest mixtures. The generated multiply charged polypeptides enable efficient tandem mass spectrometric (MS/MS)-based peptide sequencing. ELDI-MS/MS of protein digests and small intact proteins was performed both by collisionally activated dissociation (CAD) and by nozzle-skimmer dissociation (NSD). ELDI-MS/MS may be a useful tool for protein sequencing analysis and top-down proteomics study, and may complement matrix-assisted laser desorption/ionization (MALDI)-based measurements.  相似文献   

8.
Atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) and ion trap mass spectrometry have been used to study the fragmentation behavior of native peptides and peptide derivatives prepared for de novo sequencing applications. Sulfonic acid derivatized peptides were observed to fragment more extensively and up to 28 times more efficiently than the corresponding native peptides. Tandem mass spectra of native peptides containing aspartic or glutamic acids are dominated by cleavage on the C-terminal side of the acidic residues. This significantly limits the amount of sequence information that can be derived from those compounds. The MS/MS spectra of native tryptic peptides containing oxidized Met residues show extensive loss of CH(3)SOH and little sequence-specific fragmentation. On the other hand, the tandem mass spectra of derivatized peptides containing Asp, Glu and oxidized Met show much more uniform fragmentation along the peptide backbone. The AP-MALDI tandem mass spectra of some derivatized peptides were shown to be qualitatively very similar to the corresponding vacuum MALDI postsource decay mass spectra, which were obtained on a reflector time-of-flight instrument. However, the ion trap mass spectrometer offers several advantages for peptide sequencing relative to current reflector time-of-flight instruments including improved product ion mass measurement accuracy, improved precursor ion selection and MS(n). These latter capabilities were demonstrated with solution digests of model proteins and with in-gel digests of 2D-gel separated proteins.  相似文献   

9.
Titanium dioxide (TiO2)-mediated phosphopeptide enrichment has been introduced as an effective method for extracting phosphopeptides from highly complex peptide mixtures. Chemical labeling by beta-elimination/Michael addition is also useful for increasing mass intensity in phosphopeptide analysis. Both of these methods were coupled in order to simultaneously enrich phosphopeptides and allow for detection and sequencing of the enriched peptides with high mass sensitivity. Phosphopeptides were successfully enriched on TiO2 beads without the use of any hydroxy acid additives like 2,5-dihydroxybenzoic acid. Labeling was accomplished on-bead with a guanidinoethanethiol (GET) tag containing a guanidine moiety. These GET-labeled derivatives were detected by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). GET labeling converted phosphoserine into guanidinoethylcysteine, a structural arginine-mimic. In particular, GET-labeled lysine-terminated phosphopeptides showed dramatically increased peak intensities compared to those of the corresponding intact phosphopeptides. Additionally, the on-bead labeling minimized manipulation steps and sample loss. The coupled technique was also further validated by applying to the analysis of phosphopeptides from complex tryptic digests of phosphoprotein mixtures.  相似文献   

10.
A sensitive, integrated top-down liquid chromatography/mass spectrometry (LC/MS) approach, suitable for the near complete characterization of specific proteins in complex protein mixtures, such as inclusion bodies of an E. coli lysate, has been successfully developed using a hybrid linear ion trap/Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. In particular, human growth hormone (hGH) (200 fmol) was analyzed with high sequence coverage (>95%), including the sites of disulfide linkages. The high mass accuracy and resolution of the FTICR mass spectrometer was used to reveal high charge state ions of hGH (22 kDa). The highly charged intact protein ions (such as the 17+ species) were captured and fragmented in the linear ion trap cell. The fragment ions from MS/MS spectra were then successfully analyzed in the FTICR cell in an on-line LC/MS run. Peptide fragments from the N-terminal and C-terminal regions, as well as large interior fragments, were captured and identified. The results allowed the unambiguous assignment of disulfide bonds Cys53-Cys165 and Cys182-Cys189, indicative of proper folding of hGH. The disulfide bond assignments were also confirmed by analysis of the tryptic digest of a sample of hGH purified from inclusion bodies. On-line LC/MS with the linear ion trap/FTICR yields high mass accuracy in both the MS and MS/MS modes (within 2 ppm with external calibration). The approach should prove useful in biotechnology applications to characterize correctly folded proteins, both in the early protein expression and the later processed stages, using only a single automated on-line LC/MS top-down method.  相似文献   

11.
A 60 microm internal diameter (i.d.) stainless-steel needle was adapted to the orthogonal ESI probe ( microESI) of a commercial ion trap mass spectrometer, and used for capillary liquid chromatography/tandem mass spectrometry (LC/MS/MS) protein identification experiments. The modification allows for the use of nitrogen sheath gas which helps in the nebulization at LC flow rates exceeding 500 nL/min and eliminates problems caused by liquid junctions commonly used to initiate nanospray ionization (NSI). A comparison is made between the performance of a 75 microm i.d. column with a 15 microm pulled glass tip using a liquid junction, and that of a 150 microm i.d. column using the new microESI device. The combination of the 150 microm i.d. column and microESI gave sensitivity close to that of NSI (250 attomoles horse heart myoglobin digest on column), and proved to be more robust than the standard pulled glass tips of similar i.d. No evidence of metal needle catalyzed oxidation of methionine was observed during analysis of the tetrapeptide MRFA under a range of test conditions. Phosphorylated peptides in a beta-casein tryptic digest were also successfully identified using the microESI interface with a steel needle. In addition it was found that a mild sanding of the metal needle tip improved spray performance.  相似文献   

12.
We have developed a novel approach to characterize protein digests by pneumatic-splitter electrospray ionization liquid chromatography mass spectrometry (PSESI-LCMS). This technique involves an interfacing of a pneumatic splitter that can dynamically generate and control a steady split flow rate of nanoliters per minute. An average PSESI-LCMS analysis, depending on the desired split ratio, consumes less than 200 femtomoles of sample. A tryptic digest map of a glycoprotein, fetuin, and a Lys-C digest map of a recombinant neurotrophin protein, neurotrophin-3, are reported here for this investigation.  相似文献   

13.
This study demonstrates structural and conformational characterization of proteins by nanoflow electrospray ionization (nanoESI) mass spectrometry (MS) and tandem mass spectrometry (MS/MS) utilizing a quadrupole time-of-flight (Q-TOF) mass spectrometer (Micromass, Manchester, England). Model peptides were successfully sequenced at the 35 attomole (amol) level, and peptides derived from a tryptic in-gel digest of 25 femtomole (fmol) bovine serum albumin (BSA) were successfully sequenced. The results demonstrated that the MS/MS sensitivity of the Q-TOF clearly surpassed the detection limit of the silver stain. A silver destaining step greatly improved the mass analysis of peptides derived from in-gel digests. Interestingly, sequence analysis revealed BSA residue 424 (tyrosine) as a potential chlorination site. In addition, a modified procedure was successfully used to extract and measure the masses of two-dimensional polyacrylamide gel electrophoresis (2-D PAGE)-resolved proteins in the 10-68.5 kDa range. The Q-TOF was also used to monitor conformational changes of proteins. These experiments demonstrated an acid-induced denaturation of BSA in the pH 3-4 range, and heat-induced unfolding of cytochrome c between 50 and 60 degrees C. Finally, Zn2+ binding was demonstrated for the carbonic anhydrase apoprotein. In summary, the wide range of applications and the high quality of the experimental data made the Q-TOF mass spectrometer a powerful analytical tool for protein characterization.  相似文献   

14.
Atmospheric pressure matrix‐assisted laser desorption/ionization (AP‐MALDI) has proven a convenient and rapid method for ion production in the mass spectrometric (MS) analysis of biomolecules. AP‐MALDI and electrospray ionization (ESI) sources are easily interchangeable in most mass spectrometers. However, AP‐MALDI suffers from less‐than‐optimal sensitivity due to ion losses during transport from the atmosphere into the vacuum of the mass spectrometer. Here, we study the signal‐to‐noise ratio (S/N) gains observed when an on‐chip dynamic pre‐concentration/focusing approach is coupled to AP‐MALDI for the MS analysis of neuropeptides and protein digests. It was found that, in comparison with conventional AP‐MALDI targets, focusing targets showed (1) a sensitivity enhancement of approximately two orders of magnitude with S/N gains of 200–900 for hydrophobic substrates, and 150–400 for weak cation‐exchange (WCX) substrates; (2) improved detection limits as low as 5 fmol/µL for standard peptides; (3) significantly reduced matrix background; and (4) higher inter‐day reproducibility. The improved sensitivity allowed successful tandem mass spectrometric (MS/MS) sequencing of dilute solutions of a derivatized tryptic digest of a protein standard, and enabled the first reported AP‐MALDI MS detection of neuropeptides from Aedes aegypti mosquito heads. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
The detection and quantitation of apolipoproteins, important markers for coronary heart disease, in serum by liquid chromatography/tandem mass spectrometry (LC/MS/MS) using multiple reaction monitoring (MRM) is reported. A tryptic digest of depleted human serum was analysed by nanoflow LC/MS/MS at a flow rate of 300 nL/min and several apolipoproteins (Apo), including Apo A1, A2, A4, C1, C2, C3, D, F and M, were successfully identified. The analysis of the same depleted serum digest by ultra-performance (UP)LC/MS/MS operating at 700 microL/min resulted in comparable sensitivity and selectivity to the nanoflow method, but with a dramatic ( approximately 20-fold) reduction in run time. The potential of UPLC/MS/MS for the rapid quantitation of proteins in biological matrices by representative tryptic peptides was further investigated using Apo A1 and its corresponding stable isotopically labelled tryptic AQUA peptide (DYVSQFEGSALGK). A set of serum-based Apo A1 calibrators from a clinical analyser kit were digested without depletion following the addition of the AQUA peptide and analysed using UPLC/MS/MS. A linear calibration curve was generated from peak area ratios to the labelled peptide with a coefficient of correlation of 0.9989. Standard curves were also generated for other apolipoproteins together with Apo B100, Apo E, lecithin cholesterol acyltransferase and albumin, which were also detected in the standards. The concentration of Apo A1 in five fresh undepleted human serum samples and a quality control (QC) sample were determined using both the UPLC/MS/MS method and a clinical analyser. Results were comparable and the quantitative study, involving 80 injections which took hours rather than days to complete, demonstrates the high-throughput potential of UPLC/MS/MS to quantify multiple serum proteins without the need for antibodies, and thus provide an alternative to the use of clinical analysers for serum protein biomarkers.  相似文献   

16.
Derivatization of tryptic peptides using an Ettan CAF matrix-assisted laser desorption/ionization (MALDI) sequencing kit in combination with MALDI-post source decay (PSD) is a fast, accurate and convenient way to obtain de novo or confirmative peptide sequencing data. CAF (chemically assisted fragmentation) is based on solid-phase derivatization using a new class of water stable sulfonation agents, which strongly improves PSD analysis and simplifies the interpretation of acquired spectra. The derivatization is performed on solid supports, ZipTip(microC18, limiting the maximum peptide amount to 5 microg. By performing the derivatization in solution enabled the labeling of tryptic peptides derived from 100 microg of protein. To increase the number of peptides that could be sequenced, derivatized peptides were purified using multidimensional liquid chromatography (MDLC) prior to MALDI sequencing. Following the first dimension strong cation exchange (SCX) chromatography step, modified peptides were separated using reversed-phase chromatography (RPC). During the SCX clean up step, positively charged peptides are retained on the column while properly CAF-derivatized peptides (uncharged) are not. A moderately complex tryptic digest, prepared from six different proteins of equimolar amounts, was CAF-derivatized and purified by MDLC. Fractions from the second dimension nano RPC step were automatically sampled and on-line dispensed to MALDI sample plates and analyzed using MALDI mass spectrometry fragmentation techniques. All proteins in the derivatized protein mixture digest were readily identified using MALDI-PSD or MALDI tandem mass spectrometry (MS/MS). More than 40 peptides were unambiguously sequenced, representing a seven-fold increase in the number of sequenced peptides in comparison to when the CAF-derivatized protein mix digest was analyzed directly (no MDLC-separation) using MALDI-PSD. In conclusion, MDLC purification of CAF-derivatized peptides significantly increases the success rate for de novo and confirmative sequencing using various MALDI fragmentation techniques. This new approach is not only applicable to single protein digests but also to more complex digests and could, thus, be an alternative to electrospray ionization MS/MS for peptide sequencing.  相似文献   

17.
Identification of ubiquitination (Ub) sites is of great interest due to the critical roles that the modification plays in cellular regulation. Current methods using mass spectrometry rely upon tryptic isopeptide diglycine tag generation followed by database searching. We present a novel approach to ubiquitin detection based upon the dimethyl labeling of isopeptide N-termini glycines. Ubiquitinated proteins were digested with trypsin and the resulting peptide mixture was derivatized using formaldehyde-D2 solution and sodium cyanoborohydride. The dimethylated peptide mixtures were next separated by liquid chromatography and analyzed on a quadrupole-TOF based mass spectrometer. Diagnostic b2′ and a1′ ions released from the isopeptide N-terminus upon collision-induced dissociation (CID) were used to spectrally improve the identification of ubiquitinated isopeptides. Proof of principle was established by application to a ubiquitinated protein tryptic digest spiked into a six-protein mix digest background. Extracted ion chromatograms of the a1′ and b2′ diagnostic product ions from the diglycine tag resulted in a significant reduction in signal complexity and demonstrated a selectivity towards the identification of diglycine branched isopeptides. The method was further shown to be capable of identifying diglycine isopeptides resulting from in-gel tryptic digests of ubiquitin enriched material from a His-Ub transfected cell line. We envisage that these ions may be utilized in global ubiquitination studies with post-acquisition MS/MS (or MSe) data interrogation on high resolution hybrid mass spectrometers.
Figure
?  相似文献   

18.
Liquid separation methods in combination with electrospray mass spectrometry as well as the recently introduced fragmentation method electron capture dissociation (ECD) have become powerful tools in proteomics research. This paper presents the results of the first successful attempts to combine liquid chromatography (LC) and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with ECD in the analysis of a mixture of standard peptides and of a bovine serum albumin tryptic digest. A novel electron injection system provided conditions for ECD sufficient to yield extensive sequence information for the most abundant peptides in the mixtures on the time-scale of the chromatographic separation. The results suggest that LC/ECD-FTICRMS can be employed in the characterization of peptides in enzymatic digests of proteins or protein mixtures and identify and localize posttranslational modifications.  相似文献   

19.
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is widely used for characterizing multiple samples of complex mixtures with similar compositions. This article addresses a data acquisition strategy for collecting a maximal number of unique, high-quality MS/MS during LC-MS/MS analysis of multiple samples. Based on the concept that a component only needs to be identified once when analyzing multiple samples with similar compositions, an automated intersample data-dependent acquisition strategy was developed. The strategy is based on precursor ion exclusion (PIE) and is implemented in MassAnalyzer in an automated fashion for Thermo Scientific (San Jose, CA, USA) mass spectrometers. In this method, MassAnalyzer submits one sample at a time to the sample queue. After data acquisition of each sample, MassAnalyzer automatically analyzes the data to generate a PIE list based on the MS/MS precursor ions, merges this list with the list generated from previous runs, adds the list to the MS method file, and submits the next sample to the queue. The PIE list contains both m/z value and time window for each precursor ion, and is generated intelligently so that if an MS/MS is insufficient for identifying the peak of interest, it will be collected again near the top of the peak in the next run. Therefore, the strategy maximizes both quality and the number of unique MS/MS. When automated PIE was used to acquire LC-MS/MS data of an antibody tryptic digest and a soy hydrolysate sample, the number of identified ions increased by 52% and 93%, respectively, compared with data acquired without using PIE.  相似文献   

20.
Shiau KJ  Hung SU  Lee HW  Wu CC 《The Analyst》2011,136(9):1922-1927
Simultaneous detection of multiply and singly phosphorylated peptides using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is challenging because of suppression effects during ionization. In oder to overcome this problem, this study presents a new approach to improve the detection of phosphopeptides by stepwise enrichment using polyarginine-coated (PA-coated) and titanium dioxide-coated (TiO(2)-coated) nanodiamonds for fractionation of multiply and singly phosphorylated peptides prior to on-probe MALDI MS analysis. The feasibility of this approach was demonstrated using synthetic peptides containing different numbers of phosphate groups, tryptic digests of α-casein, β-casein, and complex protein mixtures. The high specificity of the approach is shown in its effective enrichment and fractionation of phosphopeptides from the digest of β-casein and bovine serum albumin at a molar ratio as low as 1 : 1000, which out-performs the commercial Fe(3+)-IMAC and TiO(2) isolation kits. It offers a simple and effective alternative for the fractionation and identification of multiply and singly phosphorylated peptides by MALDI MS and allows for deduction of more information from limited starting materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号