首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The most recent contributions on solventless extraction techniques have been reviewed. This paper deals with those techniques that use solid phases, such as solid-phase microextraction, liquid phases, such as single-drop microextraction and hollow-fibre liquid-phase microextraction, and subcritical fluids, such as subcritical water extraction. In all cases, the most recent publications have been critically studied. Direct extraction and derivatization processes to facilitate the extraction of analytes in different areas have been included. Hyphenated approaches, if available, are also included in this review. Comparison of techniques organized by analytes and matrices also enhances this critical overview of solventless techniques.  相似文献   

2.
As the drive towards green extraction methods has gained momentum in recent years, it has not always been possible to eliminate organic solvents completely. However, the volumes employed have been reduced remarkably, so that a single microdrop is sufficient in some cases. This effort has led to the development of various liquid phase microextractions namely single drop microextraction (SDME), hollow fiber liquid phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME) and solidified floating organic drop microextraction (SFODME). In this review, the historical development and overview of these miniaturized liquid phase extraction methodologies have briefly been discussed and a comprehensive collection of application of the these methods in combination with different analytical techniques for preconcentration and determination of ultra trace amounts of metals and organometal ions in various matrices have been summarized.  相似文献   

3.
Growing concerns related to antibiotic residues in environmental water have encouraged the development of rapid, sensitive, and accurate analytical methods. Single-drop microextraction has been recognized as an efficient approach for the isolation and preconcentration of several analytes from a complex sample matrix. Thus, single-drop microextraction techniques are cost-effective and less harmful to the environment, subscribing to green analytical chemistry principles. Herein, an overview and the current advances in single-drop microextraction for the determination of antibiotics in environmental water are presented were included. In particular, two main approaches used to perform single-drop microextraction (direct immersion-single-drop microextraction and headspace-single-drop microextraction) are reviewed. Furthermore, the impressive analytical features and future perspectives of single-drop microextraction are discussed in this review.  相似文献   

4.
Residues of steroid hormones have become a cause for concern because they can affect the biological activity of non-target organisms. Steroid hormones are a potential risk for wildlife and humans through the consumption of contaminated food or water. Their determination requires extraction and clean-up steps, prior to detection, to reach low concentration levels. In recent years, a great effort has been made to develop new analytical methodologies, such as microextraction techniques, that reduce environmental pollution. Researchers have modified old methods to incorporate procedures that use less-hazardous chemicals or that use smaller amounts of them. They are able to do direct analysis using miniaturised equipment and reduced amounts of solvents and wastes. These accomplishments are the main objectives of green analytical chemistry. In this overview, we focus on microextraction techniques for the determination of steroid hormones in biological (e.g., human urine, human serum, fish, shrimp and prawn tissue and milk) and environmental (e.g., wastewaters, surface waters, tap waters, river waters, sewage sludges, marine sediments and river sediments) samples. We comment on the most recent applications in sorptive-microextraction modes, such as solid phase microextraction (SPME) with molecularly imprinted polymers (MIPs), in-tube solid-phase microextraction (IT-SPME), stir-bar sorptive extraction (SBSE) and microextraction in packed sorbent (MEPS). We also describe liquid-phase microextraction (LPME) approaches reported in the literature that are applied to the determination of steroid hormones.  相似文献   

5.
This review summarizes literature data from the past 5 years on new developments and/or applications of sample preparation methods for analysis of volatile organic compounds (VOC), mainly in air and water matrices. Novel trends in the optimization and application of well-established airborne VOC enrichment techniques are discussed, like the implementation of advanced cooling systems in cryogenic trapping and miniaturization in adsorptive enrichment techniques. Next, focus is put on current tendencies in integrated sampling-extraction-sample introduction methods such as solid phase microextraction (SPME) and novel in-needle trapping devices. Particular attention is paid to emerging membrane extraction techniques such as membrane inlet mass spectrometry (MIMS) and membrane extraction with a sorbent interface (MESI). For VOC enrichment out of water, recent evolutions in direct aqueous injection (DAI) and liquid-liquid extraction (LLE) are highlighted, with main focus on miniaturized solvent extraction methods such as single drop microextraction (SDME) and liquid phase microextraction (LPME). Next, solvent-free sorptive enrichment receives major attention, with particular interest for innovative techniques such as stir bar sorptive extraction (SBSE) and solid phase dynamic extraction (SPDE). Finally, recent trends in membrane extraction are reviewed. Applications in both immersion and headspace mode are discussed.  相似文献   

6.
During the last decade, solid-phase microextraction (SPME) has gained widespread acceptance for analyte matrix separation and preconcentration. Relatively few data are currently available dealing with in-house production of fibres with tailor-made properties to be used for SPME, though recently the number of publications evaluating new coatings has been considerably growing. This review, centred on publications that appeared during the last five years, is resuming different approaches which can be used for fibre production and further summarises alternative techniques closely related to SPME, such as in-tube extraction or single-drop microextraction (SDME). The aim is to give the reader a concise overview of recent developments in new coating procedures and materials, including the respective applications.  相似文献   

7.
Conductive polymers (CPs) are classified as materials which exhibit highly reversible redox behavior and the unusual combined properties of metal and plastics. CPs, due to their multifunctionality, ease of synthesis and their stability, have attracted more attentions in different fields of research, including sample preparation. CPs along with several commercial hydrophilic sorbents, are alternative to the commercially available hydrophobic sorbents which despite their high specific surface areas, have poor interactions and retentions in the extraction of polar compounds. This review covers a general overview regarding the recent progress and new applications of CPs toward their synthesis and use in novel extraction and microextraction techniques including solid phase microextraction (SPME), electrochemically controlled solid-phase microextraction (EC-SPME) and other relevant techniques. Furthermore the contribution of nano-structured CPs in these methodologies is also reviewed.  相似文献   

8.
Microextraction-based sample preparation techniques have exhibited remarkable importance in analytical chemistry since they were first developed in the 1980s. The application of these techniques involves efficient and, at the same time, environmentally-friendly analytical methodologies. They are also generally faster when compared with classical sample preparation techniques, requiring low solvent and sample volumes, and also allowing for automated or semi-automated procedures. This paper provides an overview of the basic principles of sample preparation techniques and the important applications and developments that have taken place in this area over the past five years. These procedures include solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE), bar adsorptive microextraction (BAμE), rotating disk sorptive extraction (RDSE), micro solid-phase extraction (μ-SPE) and liquid-phase microextraction (LPME). The main variations are discussed with a focus on recent applications in the analysis of environmental water samples. Lastly, some of the trends and perspectives associated with these outstanding microextraction sample preparation approaches are highlighted.  相似文献   

9.
Microextraction of drugs   总被引:3,自引:0,他引:3  
This review will attempt to provide an overview as well as a theoretical and practical understanding of the use of microextraction technologies for drug analysis. The majority of the published reports to date focus on the use of fibre solid-phase microextraction and so the review is significantly focused on this technology. Other areas of microextraction such as single drop and solvent film microextraction are also described. Where there are insufficient examples in the literature to illustrate important concepts, examples of non-drug analyses are presented. The review is intended for readers new to the field of microextraction or its use in drug extraction, but also provides an overview of the most recent advances in the field which may be of interest to more experienced users. Particular emphasis is placed on the effect various sample matrices have on extraction characteristics.  相似文献   

10.
In recent years, the interest in new extraction methods with lower sample volume requirements, simpler equipment and handling, and lower reagent consumption, has led to the development of a series of microextraction methods based on extraction phases in the microliter order. Nowadays, many references can be found for several of these methods, which imply a wide range of applications referred to both the analyte and the sample nature. In this paper, recent developments in both well-established microextraction techniques (solid phase microextraction, hollow-fiber liquid phase microextraction, dispersive liquid–liquid microextraction, etc.) and recently appeared microextraction procedures (nanoextraction systems, microchip devices, etc.) for the clinical analysis of biological samples will be reviewed and discussed.  相似文献   

11.
An overview of the combination of liquid-phase microextraction (LPME) techniques with graphite furnace atomic absorption spectrometry (GFAAS) is reported herein. The high sensitivity of GFAAS is significantly enhanced by its association with a variety of miniaturized solvent extraction approaches. LPME-GFAAS thus represents a powerful combination for determination of metals, metalloids and organometallic compounds at (ultra)trace level. Different LPME modes used with GFAAS are briefly described, and the experimental parameters that show an impact in those microextraction processes are discussed. Special attention is paid to those parameters affecting GFAAS analysis. Main issues found when coupling LPME and GFAAS, as well as those strategies reported in the literature to solve them, are summarized. Relevant applications published on the topic so far are included.  相似文献   

12.
Sample preparation is a critical step in forensic analytical toxicology. Different extraction techniques are employed with the goals of removing interferences from the biological samples, such as blood, tissues and hair, reducing matrix effects and concentrating the target analytes, among others. With the objective of developing faster and more ecological procedures, microextraction techniques have been expanding their applications in the recent years. This article reviews various microextraction methods, which include solid‐based microextraction, such as solid‐phase microextraction, microextraction by packed sorbent and stir‐bar sorptive extraction, and liquid‐based microextraction, such as single drop/hollow fiber‐based liquid‐phase microextraction and dispersive liquid–liquid microextraction, as well as their applications to forensic toxicology analysis. The development trend in future microextraction sample preparation is discussed.  相似文献   

13.
In this paper the most recent developments in the microextraction of polar analytes from aqueous environmental samples are critically reviewed. The particularities of different microextraction approaches, mainly solid-phase microextraction (SPME), stir-bar-sorptive extraction (SBSE), and liquid-phase microextraction (LPME), and their suitability for use in combination with chromatographic or electrically driven separation techniques for determination of polar species are discussed. The compatibility of microextraction techniques, especially SPME, with different derivatisation strategies enabling GC determination of polar analytes and improving their extractability is revised. In addition to the use of derivatisation reactions, the possibility of enhancing the yield of solid-phase microextraction methods for polar analytes by using new coatings and/or larger amounts of sorbent is also considered. Finally, attention is also focussed on describing the versatility of LPME in its different possible formats and its ability to improve selectivity in the extraction of polar analytes with acid-base properties by using separation membranes and buffer solutions, instead of organic solvents, as the acceptor solution.  相似文献   

14.
In this study, the application of a novel nanomaterial composite was investigated in two microextraction techniques of solid‐phase microextraction and a needle trap device in a variety of sampling conditions. The optimum sampling temperature and relative humidity were 10°C and 20%, respectively, for both techniques with two sorbents of graphene/silica composite and polydimethyl siloxane. The two microextraction techniques with the proposed sorbent showed recoveries of 95.2 and 94.6% after 7 days. For the needle trap device the optimums desorption time and temperature were 3 min at 290°C and for SPME these measures were 1 and 1.5 min at 240–250°C for the graphene/silica composite and polydimethyl siloxane, respectively. The relative standard division obtained in inter‐ and intra‐day comparative studies were 3.3–14.3 and 5.1–25.4, respectively. For four sample the limit of detection was 0.021–0.25 ng/mL, and the limit of quantitation was 0.08–0.75 ng/mL. The results show that the graphene/silica composite is an appropriate extraction media for both techniques. Combining an appropriate sorbent with microextraction techniques, and using these in conjunction with a sensitive analytical instrument can introduce a strong method for sampling and analysis of occupational and environmental pollutants in air.  相似文献   

15.
Sulfonamides (SAs) have been the most widely used antimicrobial drugs for more than 70 years, and their residues in foodstuffs and environmental samples pose serious health hazards. For this reason, sensitive and specific methods for the quantification of these compounds in numerous matrices have been developed. This review intends to provide an updated overview of the recent trends over the past five years in sample preparation techniques and methods for detecting SAs. Examples of the sample preparation techniques, including liquid–liquid and solid-phase extraction, dispersive liquid–liquid microextraction and QuEChERS, are given. Different methods of detecting the SAs present in food and feed and in environmental, pharmaceutical and biological samples are discussed.  相似文献   

16.
Natural product analysis has gained wide attention in recent years, especially for herbal medicines, which contain complex ingredients and play a significant clinical role in the therapy of numerous diseases. The constituents of natural products are usually found at low concentrations, and the matrices are complex. Thus, the extraction of target compounds from natural products before analysis by analytical instruments is very significant for human health and its wide application. The commonly used traditional extraction methods are time-consuming, using large amounts of sample and organic solvents, as well as expensive and inefficient. Recently, microextraction techniques have been used for natural product extraction to overcome the disadvantages of conventional extraction methods. In this paper, the successful applications of and recent developments in microextraction techniques including solvent-based and sorbent-based microextraction methods, in natural product analysis in recent years, especially in the last 5 years, are reviewed for the first time. Their features, advantages, disadvantages, and future development trends are also discussed.  相似文献   

17.
Analytical methods providing high throughput are required for the ever increasing number of samples in bioanalysis. Currently, the method of choice in bioanalysis is LC-MS-MS. This method is quite rapid and thereby the focus has been directed to sample preparation as being a bottleneck in total analysis systems. It has become necessary to develop sample preparation techniques to a new improved level. This development has been based on a systematic and scientific approach. The key factors in this development have been miniaturization, integration, and automation of the techniques. This review provides a short overview of recent developments. Special emphasis is on two techniques: microextraction in packed syringe (MEPS) and use of a monolithic acrylamide plug as sorbent in polypropylene tips primarily intended for use with 96-well plate systems.  相似文献   

18.
Detection of biomarkers in exhaled breath has been gaining increasing attention as a tool for diagnosis of specific diseases. However, rapid and accurate quantification of biomarkers associated with specific diseases requires the use of analytical methods capable of fast sampling and preconcentration from breath matrix. In this regard, solid phase microextraction and needle trap technology are becoming increasingly popular in the field of breath analysis due to the unique benefits imparted by such methods, such as the integration of sampling, extraction, and preconcentration in a single step. This review discusses recent advances in breath analysis using these sample preparation techniques, providing a summary of recent developments of analytical methods based on breath volatile organic compounds analysis, including the successful identification of various biomarkers related to human diseases.  相似文献   

19.
Single-drop microextraction (SDME) has become more popular than other microextraction techniques because it is simple, cost-effective, easy to operate and nearly solvent-free. The technique has been employed successfully for trace analysis in environmental, biomedical and food applications. In view of the increasingly stringent regulatory limits for many pesticides, which are below the LOD of the existing instruments, SDME may provide a cost-effective solution for reducing the LOD of pesticides. The present review focuses on recent development in SDME technique, and its application coupled with various analytical techniques, such as GC-MS, GC and HPLC for pesticide residue analysis in different matrices. The advantages, limitations and outlook on the future of SDME technique for its wider applications are also discussed.  相似文献   

20.
This review follows up on Part 1, which focused on classification and evaluation of single drop and sorbent‐based microextraction techniques. Membrane‐ and homogenous phase‐based microextraction techniques are discussed and classified in Part 2. These techniques are more recent than those in Part 1 and considerable attention has been paid to their development. The new methodologies are more sensitive and, thanks to their miniaturization, they can be classified as “green”, but no exhaustive classification is available. We hope that this review will contribute to better orientation in these methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号