首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sequential injection-capillary electrophoresis (SI-CE) system for the fast and automated quantitative analysis of anions and cations is described. Because of the low sample load in capillary electrophoresis a split injection approach had to be used to achieve reliable hydrodynamic injection. The use of a capillary of 8 cm effective length allowed for the separation of five inorganic cations within 11 s. One common electrolyte solution containing 12 mM l-histidine and 2 mM 18-crown-6 whose pH value was adjusted to 4.0 with 10% v/v acetic acid was used for anions and cations, thus the analysis of both groups of analytes could be carried out in rapid sequence simply by switching the polarity of the high voltage supply. The system also allows automated flushing of the capillary. Detection limits between about 2 and 5 micromol l(-1) could be achieved with the contactless conductivity detector employed.  相似文献   

2.
A contactless conductometric detection (CCD) system for capillary electrophoresis (CE) with a flexible detection cell was applied for the simultaneous determination of small anions and/or cations in rain, surface and drainage water samples. The applied frequency, the amplitude of the input signal, the electrolyte conductivity and electrode distance were found to be the most significant factors affecting the detection sensitivity. 2-(N-Morpholino)ethanesulfonic acid/histidine-based (MES/His) electrolytes were used for direct conductivity detection of anions and cations, while ammonium acetate was selected for indirect conductivity determination of alkylammonium salts. For the simultaneous separation procedure, involving dual-opposite end injection, an electrolyte consisting of 20 mM MES/His, 1.5 mM 18-crown-6 and 20 microM cetyltrimethylammonium bromide provided baseline separation of 13 anions and cations in less than 6 min. The detection limits achieved were 7-30 micrograms/l for direct conductometric detection of various common inorganic cations and anions, excluding F- (62 micrograms/l) and H2PO4- (250 micrograms/l), and 35-178 micrograms/l for indirect conductometric detection of alkyl ammonium cations. The developed electrophoretic method with conductometric detection was compared to ion chromatography.  相似文献   

3.
Kubán P  Hauser PC 《Electrophoresis》2005,26(16):3169-3178
Quantitative total ionic analysis of alcoholic and nonalcoholic beverages was performed by microchip capillary electrophoresis with external contactless conductivity detection. An electrolyte solution consisting of 10.5 mM histidine, 50 mM acetic acid, and 2 mM 18-crown-6 at pH 4.1 was used for the determination of NH(4) (+), K(+), Ca(2+), Na(+), and Mg(2+). Fast analysis of Cl(-), NO(3) (-), and SO(4) (2-) was achieved in 20 mM 2-(N-morpholino)ethanesulfonic acid /histidine electrolyte solution at pH 6.0 and the simultaneous separation of up to 12 inorganic and organic anions was performed in a solution containing 10 mM His and 7 mM glutamic acid at pH 5.75. Limits of detection ranged from 90 to 250 mug/L for inorganic cations and anions, and from 200 to 2000 mug/L for organic anions and phosphate. Calibration curves showed linear dependencies over one to two orders of magnitude when the stacking effect was minimized by injecting standard solutions prepared in background electrolyte solutions. Total analysis times of 35 and 90 s were achieved for the determination of 5 inorganic cations and for the simultaneous determination of 12 inorganic and organic anions, respectively, which represents a considerable reduction of analysis time compared to conventional separation methods used in food analysis.  相似文献   

4.
Kubán P  Kubán P  Kubán V 《Electrophoresis》2003,24(9):1397-1403
A sensitive, rapid and inexpensive capillary electrophoretic method for the determination of Cr(III) and Cr(VI) species is presented. The method is based on the dual opposite end injection principle and contactless conductometric detection. The sample containing cationic and anionic species is injected into the opposite ends of the separation capillary and after the high voltage is applied, the analytes migrate towards the capillary center, where the cell of a contactless conductivity detector is placed. The method does not require any sample pretreatment, except dilution with deionized water. The separation of Cr(III), Cr(VI) and other common inorganic anions and cations is achieved in less than 4 min. The parameters of the separation electrolyte solution, such as pH and concentration of L-histidine, were optimized. Best results were achieved with electrolyte solution consisting of 4.5 mM L-histidine, adjusted to pH 3.40 with acetic acid. The detection limits achieved for Cr(III) and Cr(VI) were 10 and 39 microg.L(-1), respectively. The repeatability of migration times and peak areas was better than 0.3% and 2.8%, respectively. The developed method was applied to the analyses of rinse water samples from the galvanic industry. The results for the determination of Cr(III) and Cr(VI) were in good agreement with the results obtained by certified differential spectrophotometric method using diphenylcarbazide (CN 83 0520-40) and with the results for the total chromium concentrations determined by electrothermal atomic absorbance spectrometry (ET-AAS) and inductively coupled plasma-mass spectrometry (ICP-MS).  相似文献   

5.
Influence of acidic eluent on retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography (ion-exclusion/CEC) were investigated on a weakly acidic cation-exchange resin in the H(+)-form with conductivity. Sensitivities of analyte ions, especially weak acid anions (F(-) and HCOO(-)), were affected with degree of background conductivity level with pK(a1) (first dissociation constant) of acid in eluent. The retention behaviors of anions and cations were related to that of elution dip induced after eluting acid to separation column and injecting analyte sample. These results were largely dependent on the natures of acid as eluent. Through this study, succinic acid as the eluent was suitable for simultaneous separation of strong acid anions (SO(4)(2-), Cl(-), NO(3)(-) and I(-)), weak acid anions (F(-), HCOO(-) and CH(3)COO(-)), and cations (Na(+), K(+), NH(4)(+), Mg(2+) and Ca(2+)). The separation was achieved in 20 min under the optimum eluent condition, 20 mM succinic acid/2 mM 18-crown-6. Detection limits at S/N=3 ranged from 0.10 to 0.51 microM for strong acid anions, 0.20 to 5.04 microM for weak acid anions and 0.75 to 1.72 microM for cations. The relative standard deviations of peak areas in the repeated chromatographic runs (n=10) were in the range of 1.1-2.9% for anions and 1.8-4.5% for cations. This method was successfully applied to hot spring water containing strong acid anions, weak acid anions and cations, with satisfactory results.  相似文献   

6.
Novel CE methods have been developed on portable instrumentation adapted to accommodate a capacitively coupled contactless conductivity detector for the separation and sensitive detection of inorganic anions and cations in post‐blast explosive residues from homemade inorganic explosive devices. The methods presented combine sensitivity and speed of analysis for the wide range of inorganic ions used in this study. Separate methods were employed for the separation of anions and cations. The anion separation method utilised a low conductivity 70 mM Tris/70 mM CHES aqueous electrolyte (pH 8.6) with a 90 cm capillary coated with hexadimethrine bromide to reverse the EOF. Fifteen anions could be baseline separated in 7 min with detection limits in the range 27–240 μg/L. A selection of ten anions deemed most important in this application could be separated in 45 s on a shorter capillary (30.6 cm) using the same electrolyte. The cation separation method was performed on a 73 cm length of fused‐silica capillary using an electrolyte system composed of 10 mM histidine and 50 mM acetic acid, at pH 4.2. The addition of the complexants, 1 mM hydroxyisobutyric acid and 0.7 mM 18‐crown‐6 ether, enhanced selectivity and allowed the separation of eleven inorganic cations in under 7 min with detection limits in the range 31–240 μg/L. The developed methods were successfully field tested on post‐blast residues obtained from the controlled detonation of homemade explosive devices. Results were verified using ion chromatographic analyses of the same samples.  相似文献   

7.
Kubán P  Hauser PC 《Lab on a chip》2008,8(11):1829-1836
The determination of inorganic ions in clinical samples in less than 90 seconds was demonstrated for microchip capillary electrophoresis using capacitively coupled contactless conductivity detection (C(4)D). Bare electrophoresis chips were used in combination with external electrodes which were part of the chip holder. In order to achieve the required selectivity and sensitivity, an optimization of the electrode layout was carried out. Limits of detection (LOD) of 1 microM for K(+), 1.5 microM for Ca(2+), 3 microM for Na(+), 1.75 microM for Mg(2+) and 7.5 microM for Li(+) were achieved. The determination of inorganic cations (NH(4)(+), K(+), Na(+), Ca(2+), Mg(2+)) and anions (Cl(-), NO(3)(-), SO(4)(2-), phosphate) in blood serum and urine samples was possible in one common electrolyte solution containing 15 mM L-arginine, 10.75 mM maleic acid and 1.5 mM 18-crown-6 at pH 5.90 by simply switching the separation voltage from positive to negative polarity. Lithium, present at significant levels when used for therapeutic purposes, can also be determined in blood serum using a slightly modified background electrolyte solution.  相似文献   

8.
Hopper KG  Leclair H  McCord BR 《Talanta》2005,67(2):304-312
A novel electrolyte has been developed for the simultaneous separation of cations and anions in low explosive residue by capillary electrophoresis. This electrolyte contains 15 mM α-hydroxyisobutyric acid (HIBA) as the buffer, 6 mM imidazole as the cation chromophore, 3 mM 1,3,6-naphthalenetrisulfonic acid (NTS) as the anion chromophore, 4 mM 18-crown-6 ether as a cation selectivity modifier, and 5% (v/v) acetonitrile as an organic modifier. The pH was adjusted to 6.5 using tetramethylammonium hydroxide (TMAOH), an electroosmotic flow modifier. The method was optimized by varying the concentrations of α-HIBA, imidazole, and 1,3,6-NTS at three different pH values. The results provided a simultaneous indirect photometric analysis of both anions and cations with detection limits ranging from 0.5 to 5 ppm for anions and from 10 to 15 ppm for cations with a total run time of under 7 min. The method was then applied to the analysis of Pyrodex® RS and black powder, as well as several smokeless powders. The results obtained were consistent with previously reported results for separate anion and cation analysis and provide a faster, more complete analysis of each sample in a single chromatographic run.  相似文献   

9.
A new approach for simultaneous separation of small inorganic and organic anions and metal cations by capillary electrophoresis is demonstrated. Metal cations in the sample are transformed into their chelates with EDTA and are separated together with the anions using an anionic separation mode. Simultaneous separation of 19 common anions and cations was achieved in about 6 min with the electrolyte containing 5 mM K2CrO4, 3 mM boric acid, 35 microM cetyltrimethylammonium bromide and 12 microM EDTA at pH 8. Limits of detection (s/n = 3) were in the range from 4 ppb for Cl- up to 1250 ppb for Cu-EDTA and RSDs of peak areas ranged from 1.4% for Cl- up to 8.5% for Mn-EDTA chelate. The practical applicability of the method was demonstrated on the analysis of anions and cations in various water samples.  相似文献   

10.
Fukushi K  Hiiro K 《Talanta》1988,35(1):55-56
Low concentrations of ammonium and potassium ions (<2.0 mg/l.) were determined simultaneously by capillary type isotachophoresis based on the interaction between potassium and 18-crown-6 in the aqueous leading electrolyte. The PU value of potassium ion increased with increasing concentration of 18-crown-6 up to 3mM, whereas that of the ammonium ion remained almost constant. Thus complete separation of ammonium and potassium ions could be obtained by using 1-3mM 18-crown-6. The error in the analysis of mixtures containing ammonium and potassium ions (250-mul sample injection) was less than +/- 20% with a leading electrolyte containing 3mM 18-crown-6. The analysis time was 18 min.  相似文献   

11.
The simultaneous ion-exclusion/cation-exchange separation column packed with a polymethacrylate-based weakly acidic cation-exchange resin of 3 microm particle size was used to achieve the simultaneous high-speed separation of anions and cations (Cl(-), NO3(-), SO4(2-), Na(+), K(+), NH4(+), Ca(2+) and Mg(2+)) commonly found in environmental samples. The high-speed simultaneous separation is based on a combination of the ion-exclusion mechanism for the anions and the cation-exchange mechanism for cations. The complete separation of the anions and cations was achieved in 5 min by elution with 15 mM tartaric acid-2.5 mM 18-crown-6 at a flow-rate of 1.5 ml/min. Detection limits at S/N=3 ranged from 0.36 to 0.68 microM for anions and 0.63-0.99 microM for cations. This method has been applied to the simultaneous determination of anions and cations in several environmental waters with satisfactory results.  相似文献   

12.
The application of laboratory-made aluminium-adsorbing silica gel (Al-Silica) as a cation-exchange stationary phase to ion chromatography-indirect photometric detection (IC-IPD) for common mono- and divalent cations (Li+, Na+, NH+, K+, Mg2+ and Ca2+) was carried out by using protonated tyramine (4-aminoethylphenol) as eluent ion. When using 1.2 mM tyramine-0.2 mM oxalic acid at pH 4.5 as eluent, incomplete separation of the monovalent cations and complete separation of the divalent cations were achieved in 17 min. Then, the addition of crown ethers in the eluent was carried out for the complete separation of the mono- and divalent cations. As a result, when using 1.2 mM tyramine--0.2 mM oxalic acid at pH 4.5 containing either 5 mM 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane) or 0.5 mM and 18-crown-6 (1,4,7,10,13,16-hexaoxacyclooctadecane) as eluent, excellently simultaneous separation of these cations was achieved in 21 min. The proposed IC-IPD was successfully applied to the determination of major cations in natural water samples.  相似文献   

13.
A simple analytical system using disposable, open-tubular ion exchange clean-up precolumns coupled in-line to capillary electrophoresis for direct injection of biological samples is presented. The clean-up precolumns were prepared from fused silica capillaries by thermally initiated layer-by-layer polymerization of poly(butadiene-maleic acid) (PBMA) directly on the capillary wall. Typically, 6 cm long precolumns with 4-layers of PBMA were used for sample pretreatment. A robust and reproducible coupling between the precolumn (75 μm ID) and the analytical capillary (50 μm ID) was achieved using an inexpensive, commercially available low dead volume union. No extra dispersion of the analyte zones was observed. Proteins and other high molecular weight compounds from biological sample matrices were retained on the cation-exchanger sites of the precolumn, which eliminated their adsorption on analytical capillary walls and ensured stable electroosmotic flow and migration times of target analytes. Unretained small inorganic cations migrated freely into the analytical capillary for separation and detection. Applicability of the sample clean-up procedure was proved by determination of major inorganic cations in blood serum and plasma samples using capillary electrophoresis with contactless conductivity detection. Separations were performed in background electrolyte solution consisting of 15 mM L-arginine, 12.5 mM maleic acid, 3 mM 18-crown-6 at pH 5.5 and repeatabilities of migration times and peak areas were below 1.5% and 7.3%, respectively. Less than 1 μL of biological sample was required for injection.  相似文献   

14.
Prest JE  Fielden PR 《Talanta》2008,75(3):841-845
A new method has been devised to allow the determination of small inorganic anions using isotachophoresis. This method makes use of indium(III) as a counter ion to manipulate the effective mobilities of inorganic anion species by means of complexation reactions. This new procedure successfully allowed the simultaneous determination of nitrate, chloride and sulphate to be realised on a capillary scale instrument and in a chip-based separation device. The electrolyte system developed to allow the separation to be achieved employed a 10mM bromide-based leading electrolyte containing 1.25 mM indium(III) at pH 3.15 and a terminating electrolyte of cyanoacetic acid.  相似文献   

15.
The application of unmodified silica gel (Super Micro Bead Silica Gel B-5, SMBSG B-5) as a cation-exchange stationary phase in ion chromatography with indirect photometric detection (IC-IPD) for the separation of common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) was carried out using various aromatic monoamines [tyramine [4-(2-aminoethyl)phenol], benzylamine, phenylethylamine, 2-methylpyridine and 2,6-dimethylpyridine] as eluents. When using these amines as eluents, the peak resolution between these mono- and divalent cations was not quite satisfactory and the peak shapes of NH4+ and K+ were largely destroyed on the SMBSG B-5 silica gel column. Hence, the application of SMBSG B-5 silica gel calcinated at 200, 400, 600, 800 and 1000 degrees C for 5 h in the IC-IPD was carried out. The peak shapes of the monovalent cations were greatly improved with increasing calcination temperature and, as a result, symmetrical peaks of these mono- and divalent cations were obtained on the SMBSG B-5 silica gel calcinated at 1000 degrees C as the stationary phase. In contrast, the peak resolution between these mono- and divalent cations was not improved. Therefore, crown ethers [18-crown-6 (1,4,7,10,13,15-hexaoxacyclooctadecane), 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane)] were added to the eluent for the complete separation of these mono- and divalent cations. Excellent simultaneous separation and highly sensitive detection at 275 nm were achieved in 25 min on a column (150x4.6 mm I.D.) packed with SMBSG B-5 silica gel calcinated at 1000 degrees C by elution with 0.75 mM tyramine-0.25 mM oxalic acid at pH 5.0 containing either 1.0 mM 18-crown-6 or 10 mM 15-crown-5.  相似文献   

16.
A capillary zone electrophoresis (CZE)-potential gradient detection (PGD) method coupled with field-amplified sample injection was developed to determine alkali metal, alkaline-earth metal, nickel, lead and ammonium ions. The capillary surface was coated with dialkylimidazolium-based ionic liquid and thus the electroosmotic flow (EOF) of the capillary was reversed. The buffer composed of 7.5 mM lactic acid, 0.6 mM 18-crown-6, 12 mM alpha-cyclodextrin (alpha-CD); it was adjusted to pH 4.0 by 1-hexyl-3-methylimidazolium hydroxide. The 11 cations were baseline separated within 14 min with 5.1-18.9 x 10(4) plates (for 40-cm-long capillary) in separation efficiency, and the detection limits were in the range of 0.27-7.3 ng/ml. The method showed good reproducibility in terms of migration time with RSD < or = 0.90% for run-to-run and < or = 1.65 for day-to-day assessment.  相似文献   

17.
A new capillary electrophoretic approach for simultaneous separation of fast anions and cations is demonstrated. Indirect UV detection at 214 nm in conjunction with electromigration sampling from both ends of the capillary was developed. Two electrolyte systems based on imidazole-nitrate and copper(II)-ethylenediamine-nitrate were investigated for the simultaneous separation of chloride, sulphate, hydrocarbonate, potassium, ammonium, calcium, sodium and magnesium ions. Experimental parameters that were evaluated included a nature of UV chromophore, pH of electrolyte, a nature of complexing agent. The method permits the excellent separation of three anions and five cations in only 4 min using electrolyte system containing 2.5 mmol l−1 Cu(NO3)2, 5 mmol l−1 ethylenediamine and 1 mmol l−1 fumaric acid at pH 8.5 adjusted with tetraethylammonium hydroxide.  相似文献   

18.
A rapid, simple and reliable capillary electrophoresis method for the separation and quantitation of inorganic cations with indirect UV detection at 214 nm was developed. The electrolyte was: 12 mM imidazole as background absorbance provider; 5 mM malic acid and 1.0 mM 18-crown-6 ether as complexing agents; and 20% D2O (v/v) to improve ion mobility. The pH was 4.25. The applied voltage was 22 kV at 22°C. Nine ions were completely separated and determined with correlation coefficients of 0.9979-0.9992. The relative standard deviations (RSD) were less than 0.5% for migration time and less than 5.2% for peak area (n=8). The detection limits (S/N=3) were from 0.08 mg L−1 (for Na+) to 0.51 mg L−1 (for Cu2+). To assess the reliability atomic absorption (AA) was also used to determine the same samples. Satisfactory results were obtained for real samples of jasmine tea drink and coconut milk.   相似文献   

19.
Electromembrane extraction was used for simultaneous sample cleanup and preconcentration of lithium from untreated human body fluids. The sample of a body fluid was diluted 100 times with 0.5 mM Tris solution and lithium was extracted by electromigration through a supported liquid membrane composed of 1-octanol into 100 mM acetic acid acceptor solution. Matrix compounds, such as proteins, red blood cells, and other high-molecular-weight compounds were efficiently retained on the supported liquid membrane. The liquid membrane was anchored in pores of a short segment of a polypropylene hollow fiber, which represented a low cost, single use, disposable extraction unit and was discarded after each use. Acceptor solutions were analyzed using capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C(4) D) and baseline separation of lithium was achieved in a background electrolyte solution consisting of 18 mM L-histidine and 40 mM acetic acid at pH 4.6. Repeatability of the electromembrane extraction-CE-C(4) D method was evaluated for the determination of lithium in standard solutions and real samples and was better than 0.6 and 8.2% for migration times and peak areas, respectively. The concentration limit of detection of 9 nM was achieved. The developed method was applied to the determination of lithium in urine, blood serum, blood plasma, and whole blood at both endogenous and therapeutic concentration levels.  相似文献   

20.
Mo H  Zhu L  Xu W 《Journal of separation science》2008,31(13):2470-2475
Separation of inorganic anions in CE is often a challenging task because the electrophoretic mobilities of inorganic anions are comparable to or even greater than the EOF mobility. In this study, we present the use of ionic liquids (ILs) as background electrolytes (BGEs) in CE of inorganic anions. The 1-alkyl-3-methylimidazolium-based ILs as BGEs dynamically coated the capillary wall and induced a reversed EOF. This allowed the anions to comigrate with the EOF and yielded a rapid separation. Increasing the alkyl chain length of the ILs and BGE concentration can significantly improve the separation resolution. With 40 mM 1-butyl-3-methylimidazolium tetrafluoroborate as BGE, good separations of five model anions (Br-, I-, NO2(-), NO3(-), and SCN-) were achieved in a range of buffer pH values. The separation efficiency was as high as 34 600-155 000, and the RSDs of the migration times were less than 0.8% (n = 5).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号