首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Capillary electrophoresis (CE) was coupled to negative mode electrospray ionisation-mass spectrometry (MS) for separation and detection of phosphorylated and acidic metabolites in extracts of prokaryotes. Unlike previous CE-MS systems for metabolite analysis, a sheathless interface was used to improve sensitivity. To accomplish this, the separation capillary was modified by creating a porous junction near the outlet where the electrospray voltage and cathodic voltage for CE were applied. The outlet of the capillary was pulled to a 5 microm inner diameter to form an electrospray emitter and had a frit fabricated near the exit to prevent clogging. During analysis pressure was applied at the inlet of the separation column to create sufficient flow towards the detector. Limits of detection for 19 metabolites in full scan mode ranged from 20 nM for ADP ribose to 2.5 microM for alpha-ketoglutarate for 40 nL injections. Extracts of Escherichia coli, strain DH5-alpha, were analyzed using this system. In full scan mode, 118 different metabolites were detected. Tandem mass spectrometry was also employed to attempt identification. Reproducible fragmentation of 19 parent peaks was found and 10 of these produced spectra that were consistent with identification obtained from matching to compounds in the MetaCyc database. These results demonstrate the utility of a sensitive CE-MS system for large scale metabolite detection in biological samples.  相似文献   

2.
The performance of a prototype porous tip sprayer for sheathless capillary electrophoresis-mass spectrometry (CE-MS) of intact proteins was studied. Capillaries with a porous tip were inserted in a stainless steel needle filled with static conductive liquid and installed in a conventional electrospray ionization (ESI) source. Using a BGE of 100 mM acetic acid (pH 3.1) and a positively charged capillary coating, a highly reproducible and efficient separation of four model proteins (insulin, carbonic anhydrase II, ribonuclease A and lysozyme) was obtained. The protein mass spectra were of good quality allowing reliable mass determination of the proteins and some of their impurities. Sheath-liquid CE-MS using the same porous tip capillary and an isopropanol-water-acetic acid sheath liquid showed slightly lower to similar analyte responses. However, as noise levels increased with sheath-liquid CE-MS, detection limits were improved by a factor 6.5-20 with sheathless CE-MS. The analyte response in sheathless CE-MS could be enhanced using a nanoESI source and adding 5% isopropanol to the BGE, leading to improved detection limits by 50-fold to 140-fold as compared to sheath liquid interfacing using the same capillary - equivalent to sub-nM detection limits for three out of four proteins. Clearly, the sheathless porous tip sprayer provides high sensitivity CE-MS of intact proteins.  相似文献   

3.
A procedure for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) of proteins is presented. The use of a newly presented capillary coating, PolyE-323, provided fast separations of typically a few minutes with high efficiency, good deactivation, and no bleeding into the mass spectrometer. Capillaries coated with PolyE-323 showed high stability over a range of pH 2-10, and tolerance towards methanol and acetonitrile, two modifiers commonly used in CE-ESI-MS. Due to the speed and simplicity of the coating procedure, the polymeric surface could, if necessary, easily be regenerated. This capability is especially valuable when working with samples of complex matrix, where a capillary surface cleaning step might be desired in order to eliminate possible memory effects. The potential of PolyE-323-coated capillaries in bioanalysis using CE-ESI-MS was demonstrated by analyzing peptides and proteins up to 66 kDa using time of flight (TOF)-MS. Due to the stable, anodal electroosmotic flow generated by the coating, the use of a sheathless ESI interface was enabled, demonstrated in peptide analysis with attomole sensitivity. The fast on-line CE-ESI-TOF system using PolyE-323-coated capillaries provided efficient separation and detection of a large number of peaks in a short time, exemplified by the analysis of a tryptic digest of bovine serum albumin (BSA). The capability of the developed capillary surface coating was demonstrated by the separation of human plasma and cerebrospinal fluid (CSF).  相似文献   

4.
张含智  李凤  康经武 《色谱》2023,41(2):160-167
毛细管电泳-质谱联用技术具有分离效率高、检测灵敏度高、样品消耗量少,可同时提供样品的结构信息等优点,成为复杂样品分离分析的强有力工具。但是,毛细管电泳与质谱联用的接口技术依然未能很好的解决。为了拓展我们发展的金箔包裹的毛细管电泳分离柱尖端直接作为喷雾电极和无鞘流质谱接口的应用,本文报道了用无鞘流接口毛细管电泳-电喷雾质谱联用(CE-ESI-MS)分析5种酪氨酸激酶抑制剂(舒尼替尼、甲磺酸伊马替尼、吉非替尼、达沙替尼、埃罗替尼)的研究结果。这种接口集分离与电喷雾离子化于一根毛细管中,制作简单,成本低廉,且可批量制作。实验发现采用非水毛细管电泳分离模式不仅可以对5种酪氨酸激酶抑制剂实现基线分离,而且可以获得稳定的质谱信号。考察了电解质溶液组成对分离效果的影响,得到优化的背景电解质组成,即含2%(v/v)乙酸及5 mmol/L乙酸铵的乙腈-甲醇(80∶20, v/v)混合溶剂。在优化的条件下,5种激酶抑制剂可以得到基线分离,无鞘接口也可以长时间保持稳定的电喷雾,分析物的保留时间日内、日间重复性(RSD值)分别小于0.5%和0.8%,接口批次间的RSD值小于2.6%。与水相分离条件下的CE-MS对比,非水相条件下的5种酪氨酸激酶抑制剂的分离柱效更高,检测灵敏度更高,绝对检出限达到amol级。此外,采用无鞘流CE-MS分析了各类有机酸(千层纸素A、丹酚酸C和迷迭香酸)和脂溶性的大环内酯类抗生素(阿奇霉素、红霉素和环孢素A),均可以获得良好的分离效果和质谱检测结果。  相似文献   

5.
Capillary electrophoresis-electrospray ionization-mass spectrometry has the potential to become a preferred tool for the analysis of biological mixtures and other complex samples. The development of improved interfaces in the past twenty years has been critical in demonstrating the feasibility of this technique. However, a compromise still exists between interfaces that give optimal performance and those that are practical for commercial applications. The first section of this review focuses on the technological advances in CE-ESI-MS as they relate to the key interface features for both sheath-flow and sheathless systems: delivery of the sheath liquid, shaping of the emitter tip, formation of electrical contact, and practicality in terms of ease of use and lifetime. In the second section, we review the fundamental processes that affect interface performance. Because of the complex natures of both capillary electrophoresis and electrospray ionization, flow rate, arrangement of the electrical circuit, electrochemistry, tip geometry and location of electrical contact must all be carefully managed in the design of a successful interface.  相似文献   

6.
A novel, rugged sheathless capillary electrochromatography-electrospray ionization (CEC-ESI) device, in which an open-tubular separation capillary and an electrospray tip are integrated with a Nafion tubing junction, is coupled to mass spectrometry (MS) for the analysis of amino acids and peptides. A stable electrospray was generated at nanoflow rates by applying a positive electrical potential at the Nafion membrane junction. To sustain the stable spray, an electroosmotic flow (EOF) to the spray was supported by coating the fused silica capillary with Lupamin, a high-molecular-weight linear positively charged polyvinylamine (PVAm) polymer, which also minimizes analyte adsorption. Electrochromatographic separation of amino acids and peptides was further enhanced by the chromatographic selectivity of Lupamin stationary phase for these molecules. The device was very reliable and reproducible for CEC-ESI-MS analyses of amino acids and peptides for over a hundred injections. The separation and detection behaviors of amino acids and peptides under different conditions including pH, concentration, and composition of mobile phases on Lupamin-coated and uncoated capillaries have been investigated. The relationship between nano electrospray stability and EOF is discussed.  相似文献   

7.
Tseng MC  Chen YR  Her GR 《Electrophoresis》2004,25(13):2084-2089
A simple and durable sheath liquid interface for capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) has been developed. This interface utilized a beveled tip emitter and was found to be more sensitive than the conventional sheath liquid interface. The use of a beveled tip reduces the optimal flow rate and therefore decreases sample dilution. The interface utilized a 380 microm inner diameter and 400 microm outer diameter beveled tapered tip. Because of the large inner diameter and outer diameter of the tip, the interface is robust and can be easily implemented. The performance of this interface for CZE-ESI-MS and micelle electrokinetic capillary electrophoresis-electrospray-mass spectrometry, as demonstrated by the analysis of synthetic drugs and triazine mixtures, was significantly better than results obtained using a conventional sheath liquid interface.  相似文献   

8.
Nogami C  Sawada H 《Electrophoresis》2005,26(7-8):1406-1411
Capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) was applied to the analysis of polar positional and geometrical anionic isomers. Since the investigated positional and geometrical anionic isomers have different pK(a) values, they could be separated by CE-ESI-MS under simple analytical conditions using a bare fused-silica capillary and volatile ammonium acetate buffer after optimizing buffer pH. Ortho-, meta-, para-hydroxybenzoate positional isomers were completely separated on a fused-silica capillary with 20 mM ammonium acetate buffer at pH 10.0, and cis-, trans-cyclohexane dicarboxylate geometrical isomers could be also separated with 20 mM ammonium acetate buffer at pH 4.0. Several analytical parameters affecting ESI-MS sensitivity were also investigated. It was found that both running buffer pH and sheath liquid pH had significant effects on the selectivity and the sensitivity on CE-ESI-MS analysis while sheath flow rate and other parameters had little influence. Under optimized conditions, linearity, detection limit, and repeatability of the analysis of hydroxybenzoate isomers were examined, and good results were obtained. It was found that the method presented in this paper is a simple, robust, and cost-effective method for simultaneous analysis of positional and geometrical anionic isomers as well as of other small anionic compounds.  相似文献   

9.
Hops are used almost exclusively for bitterness and flavor by brewers. We propose the first analytical application of CZE coupled to ESI-MS for the separation and structural elucidation of organic compounds in the methanolic extracts of hops, and different extraction procedures of the plant material have been carried out. The proposed method permits the identification of hop polyphenols (flavonoids glycosides and chalcones), bitter acids (alpha-acids and beta-acids), and their oxidation products. The optimization of CZE parameters (pH, concentration, and type of buffer) and ESI-MS parameters (nature and flow rate of the sheath liquid, nebulizer pressure, drying gas flow rate, temperature, and compound stability) have permitted the development of a rapid, simple, direct, and straightforward CZE-ESI-MS method for the identification of components of methanolic extracts from different hops used in the brewing process.  相似文献   

10.
The combination of capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) via a triaxial interface was studied as a potential means for the characterization of intact proteins. To evaluate the possibility to use a nonvolatile electrolyte for CE, the effect of sodium phosphate and ammonium borate on the MS signal of the proteins insulin, myoglobin, and bovine serum albumin (BSA) was investigated by employing infusion experiments, and compared to the effect of ammonium formate and formic acid. The study shows that with formic acid (50 mM, pH 2.4) the most intense protein signals were obtained, while the use of sodium phosphate buffer (5 and 10 mM, pH 7.5) almost completely diminished the MS response. Ammonium formate and ammonium borate (up to 100 mM, pH 8.5) also caused protein ion suppression, but especially with the borate buffer significant MS intensity remained. MS analysis of myoglobin revealed the loss of the heme group when an acidic CE electrolyte was used. Using a background electrolyte containing 25 mM ammonium borate (pH 8.5), it is demonstrated that a CE separation of a protein test mixture can be monitored with ESI-MS without degrading the MS performance allowing molecular weight determinations of the separated compounds. In the presence of borate, detection limits were estimated to be 5-10 microM (ca. 100 fmol injected). The usefulness of the CE-MS system employing a borate buffer is indicated by the analysis of a stored sample of BSA revealing several degradation products. A sample of placental alkaline phosphatase (PLAP), a potential therapeutic agent, was also analyzed by CE-MS indicating the presence of a protein impurity. Probably due to insufficient ionization of the PLAP (a complex glycoprotein), no MS signals of the intact protein were observed.  相似文献   

11.
The microheterogeneous peptaibol alamethicin F30 isolated from the culture broth of Trichoderma viride was analyzed by nonaqueous CE-electrospray-MS using an IT and a TOF mass analyzer. Compared to aqueous buffers, higher separation selectivity was observed for methanolic BGE allowing the detection of more minor components. The low electrophoretic mobility observed for neutral analytes under nonaqueous conditions may be explained by ion-dipole interactions between the peptide analytes and electrolyte ions. The amino acid sequences of the individual components were derived from MS(n) using the doubly or triply charged pseudomolecular ions as well as characteristic fragments as precursor ions. The exchange of Ala by alpha-aminoisobutyric acid (Aib) which is frequently observed for peptaibols was detected for several components. Additional variations included the exchange of Gln to Glu, and the loss of the C-terminal amino alcohol or of the first six amino acids from the N-terminus with concomitant formation of pyroglutamyl residues. In most cases comigration of the Aib peptaibols with the respective Ala component was observed as the mass difference of 14 Da as the result of the amino acid exchange was not sufficient to translate into an electrophoretic separation under the conditions applied. However, proper selection of the precursor ions allowed the unequivocal analysis of the components. Additional TOF-MS measurements were performed in order to resolve the ammonium adducts from comigrating compounds (i.e., Aib-Ala exchange) and to confirm the amino acid composition of the individual components. Except for neutral compounds migrating close to the EOF the mass accuracy was better than 4 ppm for the doubly charged pseudomolecular ions and better than 2 ppm for triply charged ions.  相似文献   

12.
Due to its selectivity and sensitivity, CE coupled to MS (CE-MS) has evolved as a useful analytical tool for determining drugs and metabolites in biological samples. A generic CE-ESI/MS method was developed for the enantioselective determination of basic compounds in plasma. The use of protein precipitation (PP) prior to a hydrodynamic injection (HD) was well adapted to high-concentration samples (>1 ppm) and allowed high throughput. In contrast, the combination of liquid-liquid extraction (LLE) and electrokinetic injection (EK) was time-consuming but did allow detection at the ppb level. Both approaches were fully validated according to ICH guidelines and SFSTP protocols for two pharmaceutical compounds (ecstasy and methadone (MTD)). Deuterated internal standards (IS) in the analytical procedures were used and good quantitative performance was obtained in terms of trueness and precision (repeatability and intermediate precision) since accuracy profiles were within the acceptance limits (30% for biological assay). Methods were linear over the concentration range of 0.50-175 ng/mL and 0.25-5 microg/mL for LLE-EK and PP-HD procedures, respectively. The LLE-EK methodology was finally successfully applied to quantitation of ecstasy and MTD in real cases obtained from toxicology.  相似文献   

13.
An experimental design approach is described to evaluate the main electrophoretic parameters involved in the enantioseparation of pharmaceuticals by capillary electrophoresis (CE) coupled to electrospray ionization-mass spectrometry (ESI-MS). For all experiments, the partial-filling technique was applied to avoid the chiral selector entering in the mass spectrometer ion source with a negative effect on the electrospray performance. To carry out enantioseparation, a volatile buffer constituted of 20 mM ammonium acetate at pH 4.0, and a polyvinyl alcohol-coated capillary were used. Methadone was employed as the model compound and three different cyclodextrins (CDs), namely sulfobutyl ether-beta-CD, carboxymethylated-beta-CD and hydroxypropyl-beta-CD, were selected in order to study the countercurrent process. Two different experimental designs were chosen: (i) a full-factorial design to examine the effects and significance of the investigated factors, and (ii) a central composite face-centered design to establish the mathematical model of the selected responses in function of experimental factors. The chiral selector concentration, percentage of the capillary filled with the chiral selector, and drying gas nebulization pressure were three relevant factors taken into consideration. For each CD, the methadone enantiomeric resolution, apparent selectivity, and migration time of the second enantiomer were established as responses. The latter were systematically related to experimental parameters with the help of multiple linear regression. It is noteworthy that the behaviour was different in function of the chiral selector charge. Results revealed that the nebulization pressure involved in the electrospray process and the CD concentration had a significant effect on the enantiomeric resolution, while the effect of the separation zone length was less pronounced. Finally, response surfaces were drawn from the mathematical model and experimental conditions were selected to allow a robust determination of methadone enantiomers by CE-MS.  相似文献   

14.
Zheng J  Jann MW  Hon YY  Shamsi SA 《Electrophoresis》2004,25(13):2033-2043
A method of coupling capillary zone electrophoresis (CZE) with electrospray ionization-mass spectrometry (ESI-MS) detection has been developed for monitoring an antiepileptic drug, lamotrigine (LTG) in human plasma. The CZE-MS was developed in three stages: (i) CZE separation and ESI-MS detection of LTG and tyramine (TRM, internal standard) were simultaneously optimized by studying the influence of CZE background electrolyte (BGE) pH, BGE ionic strength, and nebulizer pressure of the MS sprayer; (ii) sheath liquid parameters, such as pH, ionic strength, organic modifier content, and flow rate of the sheath liquid, were systematically varied under optimum CZE-MS conditions developed in the first stage; (iii) MS sprayer chamber parameters (drying gas temperature and drying gas flow rate) were varied for the best MS detection of LTG. The developed assay was finally applied for the determination of LTG in plasma samples. The linear range of LTG in plasma sample assay was between 0.1-5.0 microg/mL with a limit of detection as low as 0.05 microg/mL and run time less than 6 min. Finally, the concentration-time profile of LTG in human plasma sample was found to correlate well when CZE-ESI-MS was compared to a more established method of high-performance liquid chromatography with ultraviolet detection.  相似文献   

15.
An in-capillary electrode sheathless interface was applied to the capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) analysis of mixtures of small peptides, proteins, and tryptic digests of proteins. The effects of different experimental parameters on the performance of this CE/ESI-MS interface were studied. The distance of the in-capillary electrode from the CE outlet and the length of the electrode inside the capillary had no significant effects on the CE separation and ESI behavior under the experimental conditions used. However, significant enhancement of the sensitivity resulted from the use of narrower CE capillaries. Using a quadrupole mass spectrometer, an aminopropylsilane-coated capillary, and a wide scan mass-to-charge ratio range of 500–1400, detection limits of approximately 4, 1, and 0.6 fmol for cytochrome c and myoglobin were achieved for 75-, 50-, and 30-µm inner diameter capillaries, respectively. Approximately one order of magnitude lower detection limits were achieved under the multiple-ion monitoring mode. The application of the in-capillary electrode sheathless interface to real-world samples was demonstrated by CE/ESI-MS analysis of a human blood sample.  相似文献   

16.
In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed.  相似文献   

17.
A sturdy home-built sheathless CE/ESI-QTOF-MS system was developed and optimized for carbohydrate analysis. The interface and employed methodology provided a simple analytical solution to laborious CE/MS interfacing methods and to problems in characterization of complex carbohydrate mixtures that require high-resolution separation of the components. The CE/ESI interface, feasible in any MS laboratory, consists of a one-piece CE column having the CE terminus in-laboratory shaped as a microsprayer and coated with copper. The CE microsprayer was inserted into an in-house made stainless steel clenching device and the whole assembly was mounted onto a quadrupole TOF mass spectrometer. The analytical potential of the interface in terms of suitability, microsprayer performance, copper coat durability, ionization efficiency, spray stability, and sensitivity was tested first on a simple mixture of standard saccharides, which were separated, resolved, and detected with high separation efficiency. The approach was next assessed for the screening of a biological sample, a complex mixture of O-glycosylated sialylated amino acids from urine of a patient suffering from Schindler disease. Preliminary data allow this method to be considered as one of general applicability in structural glycobiology and glycomics and easy to be implemented for proteomic surveys as well.  相似文献   

18.
Safarpour H  Asiaie R 《Electrophoresis》2005,26(7-8):1562-1566
Capillary electrophoresis combined with mass spectrometry (CE-MS) was used for the rapid determination of the negatively charged herbicide, Glyphosate, in a selective dried granule (DG) formulation. The CE-MS method was required to ensure product safety from the risk of cross contamination of a selective herbicide formulation. Glyphosate separation was achieved by using a bare fused-silica capillary column, operated in the reversed-polarity mode, using ammonium formate buffer, pH 2.5. The total CE-MS analysis time was under 10 min and the limit of detection was 10 ng/mL. The CE-MS analysis of Glyphosate was simple, rapid, and selective. The method involved minimal sample handling and was proven to be ideal for cross-contamination investigations in manufacturing samples.  相似文献   

19.
A heated capillary inlet for an electrospray ionization mass spectrometry (ESI-MS) interface was compared with shorter versions of the inlet to determine the effects on transmission and ionization efficiencies for low-flow (nano) electrosprays. Five different inlet lengths were studied, ranging from 6.4 to 1.3 cm. As expected, the electrospray current transmission efficiency increased with decreasing capillary length due to reduced losses to the inside walls of the capillary. This increase in transmission efficiency with shorter inlets was coupled with reduced desolvation of electrosprayed droplets. Surprisingly, as the inlet length was decreased, some analytes showed little or no increase in sensitivity, while others showed as much as a 15-fold gain. The variation was shown to be at least partially correlated with analyte mobilities, with the largest gains observed for higher mobility species, but also affected by solution conductivity, flow rate, and inlet temperature. Strategies for maximizing sensitivity while minimizing biases in ion transmission through the heated capillary interface are proposed.  相似文献   

20.
A simple laboratory-made sheathless electrospray interface for coupling of capillary electrophoresis to ion-trap mass spectrometry (CE/MS) was developed. The interface was machined in-house and it was designed to be freely interchangeable with the commercially available ionization sources for the mass spectrometer. Sharpened fused-silica capillaries were coated with nickel by a simple electrodeless plating procedure and were used as all-in-one columns/emitters. The electrodeless plating produced a 2-5- micro m thick smooth nickel layer that lasted for more than 8 h of continuous electrospraying. The performance of the CE/MS interface was examined by using four cationic imipramine derivatives as test substances. Relative detection limits were calculated on the basis of the extracted ion electrophorograms and were in the range 6-130 nmol/L, corresponding to absolute detection limits in the range of 20-400 amol. The system was applied for analysis of impurities in an impure imipramine N-oxide preparation, and two of the impurities could be identified on the basis of online-MS(MS) spectra recorded in scan-dependent mode.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号