首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Proton activation analysis has been recently applied for the determination of stable isotopes of trace metals in blood plasma samples taken from volunteers during tracer kinetic studies. The very low values of intestinal uptake for some elements, like ruthenium, make the kinetics of the excretion crucial for interpreting the bioassay data. Therefore, a procedure has been developed to process urine samples in order to have proper targets for the activation with protons. Preliminary tests with Ru-doped samples, conducted using the MC-40 Cyclotron at JRC Ispra, has confirmed the feasibility of the method. The minimum detectable concentrations, in the current operating conditions, are 16 ng 99Ru·ml−1 and 0.5 ng 101Ru·ml−1. On leave from the Federal University of Technology, Akure, Nigeria.  相似文献   

2.
A new fluorescence method for the detection of proteins with novel composite nanoparticles (CdS/PPA) has been developed. The composite nanoparticles have been prepared through an in-situ polymerization method under ultrasonic irradiation. The surface of the composite nanoparticles was covered with functional groups (-COOH). These groups may play a major role in the improving the water solubility and biocompatibility of the nanoparticles. The composite particles is combined with proteins in NaAc-HCl buffer solution (pH=1.99), which can result in strong fluorescence, and the response is linearly proportional to the concentration of proteins. In λem/λex=650 nm/365 nm place (the stoke’ shift is 285 nm), its fluorescent strength reaches the maximum. Under the optimum conditions, the linear range is 0.10–20.0 μg·ml−1 with the detection limit of 41 ng·ml−1 for HSA, and 0.10–15.0 μg·ml−1 with the detection limit of 35 ng·ml−1 for Human γ-IgG . The method has been applied to the determination of the total protein in human serum samples collected from the hospital and the results are satisfactory.  相似文献   

3.
A linear sweep adsorptive stripping voltammetric method for the determination of netilmicin in the presence of formaldehyde has been proposed for the first time. In the presence of 3.0×10−3 g ml−1 formaldehyde, netilmicin exhibits a sensitive cathodic peak at −1.30 V (vs. the saturated calomel electrode, SCE) in a medium of Britton–Robinson buffer (pH 8.7) with a scan rate of 100 mV s−1 after a preconcentration period of 120 s at −1.10 V (vs. SCE). The peak current showed a linear dependence on the netilmicin concentration over the range 4.2×10−9–1.0×10−7 g ml−1. The achieved limits of detection and quantitation were 1.0×10−10 and 3.3×10−10 g ml−1 netilmicin, respectively. It was deduced from the experiments that the amine–aldehyde condensation product formed between netilmicin and formaldehyde is mainly responsible for the appearance of the peak. The electrochemical behavior of netilmicin in the presence of formaldehyde has been studied. The method was applied to the direct determination of netilmicin in injectable formulations and spiked human urine and serum samples.   相似文献   

4.
Irradiation and post-irradiation losses in 7 crude oils encapsulated in polyethylene and irradiated in a flux of 1012n·cm−2 sec−1 have been thoroughly studied. The fraction of mercury released during irradiations ranging from 10 minutes to 2 hours is proportional to the integrated flux received by the samples and does not differ substantially from one oil to another. Post-irradiation loss rates at 20°C range between 0.017 and 0.027%·hr−1. Storage at−20°C reduces them by at least a factor of 2. The influence on the activity of197Hg due to losses in sample weight occuring during the post-irradiation period has been examined. The fraction of radiomercury retained inside the walls of the irradiation vials versus the irradiation time has been assessed. Contamination of an inner irradiation site following prolonged irradiations of oils containing 150 μg/g of this element has been evaluated and found to have a negligible impact for trace measurements above the ng/g level.  相似文献   

5.
A new electroactive label has been used to monitor immunoassays in the determination of human serum albumin (HSA) using glassy-carbon electrodes as supports for the immunological reactions. The label was a gold(I) complex, sodium aurothiomalate, which was bound to rabbit IgG anti-human serum albumin (anti-HSA-Au). The HSA was adsorbed on the electrode surface and the immunological reaction with gold-labelled anti-HSA was then performed for one hour by non-competitive or competitive procedures. The gold(I) bound to the anti-HSA was electrodeposited in 0.1 mol L−1 HCl at −1.00 V for 5 min then oxidised in 0.1 mol L−1 H2SO4 solution at +1.40 V for 1 min. Silver electrodeposition at −0.14 V for 1 min followed by anodic stripping voltammetry were then performed in aqueous 1.0 mol L−1 NH3–2.0×10−4 mol L−1 AgNO3. For both non-competitive and competitive formats, calibration plots in the ranges 5.0×10−10 to 1.0×10−8 mol L−1 and 1.0×10−10 to 1.0×10−9 mol L−1 HSA, respectively, with estimated detection limits of 1.5×10−10 mol L−1 (10 ng mL−1) and 1.0×10−10 mol L−1 (7 ng mL−1), respectively, were obtained. Levels of HSA in two healthy volunteer urine samples were also evaluated, using both immunoassay formats.  相似文献   

6.
The ability of living filamentous cells of the cyanobacterium Oscillatoria homogenea to separate stable strontium and 90Sr from aqueous solution is demonstrated in this study. On a basis of filamentous cell biovolume, the removal were 43.78 nM·ml·(mm3)−1 and 3129.48 mBq·ml·(mm3)−1 after 240 hour incubation. The optimum pH for strontium uptake is 9±0.3. The increasing biovolume of the blue-green alga elevates sorption. In the liquid culture containing 21.2 mm3·ml−1 filamentous cells and 1000 nM·ml−1 initial strontium concentration, the maximum strontium removal was 455.34 nM·ml·(mm3)−1. At 1200 Lux illumination, the maximum removal value was 58.62 nM·ml·(mm3)−1, and at the initial strontium concentration of 6590 nM·ml−1, 235.40 nM·ml·(mm3)−1 removal was observed. The experimental data fitted to Langmuir isotherm and the model parameters and correlation coefficient (R 2) were q max = 7.143 μg·(mm3)−1, b = 0.003 and 0.99, respectively.  相似文献   

7.
A method was developed for the determination of 15 trace elements in tin. High-purity tin samples (99.9999% and 99.999%) as well as tin of technical quality were analysed. Reactor neutron activation of the tin samples was followed by distillation of the matrix activities from a HBr−H2SO4 medium and Ge(Li) gamma-ray spectrometry of the distillation residue. The sensitivity of the method is generally high. For the high-purity samples the detection limits vary from 0.02 ppb (scandium) to 200 ppb (iron) for irradiation of 1 g of tin for 1 week at a thermal flux of 5·1012n·cm−2. ·sec−1. To decontaminate the surface of the tin samples, pre- and post-irradiation etching procedures were applied. The efficiency of these etching techniques was studied.  相似文献   

8.
A preliminary study to evaluate the use of neutron activation analysis for the characterization of six groups of man-made fibers for forensic purposes has been made. A total of 81 samples of acetate, acrylic, modacrylic, nylon, polyester and rayon were analyzed. Small samples, approximately the size typically found during a crime scene search, were analyzed using a Ge(Li) detector system following a 20 min irradiation at a flux of 5·1013 n·cm−2·sec−1. The following elements were determined quantitatively in one or more of the samples: Ti, Sr, Au, Zn, Sb, Br. Mn, Mg, Cu, In, Co, Cu, V, K, Al, Cl, Na, Ca, and S. Significant qualitative and quantitative differences were found both between and within the six groups. However, within certain groups some fibers from different manufacturers showed marked similarities in qualitative and quantitative composition.  相似文献   

9.
The radiation chemical redox transformations in solutions of bromides in the presence of minor additives of iodides were studied by pulse radiolysis. The change in the concentrations of the Br and I ions changes the ratio of the formed short-lived radical anions Br2 ·−, BrI·−, and I2 ·−. The spectrum of the mixed radical anion BrI·− contains a broad optical band at 370 nm with ɛ370 = 9650 L mol−1 cm−1. The reduction potential of the BrI·−/Br, I pair is 1.25 V. The rate constants for the forward and backward reactions Br2 ·− + I ⇌ BrI·− + Br are k f = 4.3·109 and k r = 1.0·105 L mol−1 s−1, respectively; for the reactions BrI·− ⇌ Br + I·, k f = 5.7·108 s−1 and k r = 1.0·1010 L mol−1 s−1. Published in Russian in Izvestiya Akademii Nauk. Seriya Khimicheskaya, No. 9, pp. 1787–1792, September, 2008.  相似文献   

10.
Representative banded iron-formations (BIFs) from various locations of the eastern Indian geological belt were investigated by instrumental neutron activation analysis (INAA). After pre-concentration, irradiation was carried out using a neutron flux of 5.1·1016 m−2·s−1, 1.0·1015 m−2·s−1 and 3.7·1015 m−2s−1, with thermal, epi-thermal and fast neutrons, respectively. The activities in these samples were measured by a HPGe detector. Ten rare-earth elements, such as La, Ce, Nd, Sm, Eu, Tb, Ho, Tm, Yb and Lu, have been qualitatively identified and quantitatively estimated in these samples. The present investigation is an example of employing a pre-concentration method for high iron-containing ores prior to neutron activation analysis.  相似文献   

11.
Summary A new extractive spectrophotometric method is described for determining trace amounts of Mn(II) based on its reaction at pH 10.2 with 3-bromobenzohydroxamic acid (3BrHA) and subsequent extraction into Adogen 464 in toluene. The apparent molar absorptivity of the 1:3:1 (Mn:3BrHA:Adogen 464) complex is 8.7×103 l·mol−1 cm−1 at 450 nm. Beer's law is obeyed from 0.5 to 6.0 mg·1−1 of Mn(II) in the aqueous phase with a C.V. of 1.2%. The detection limit is 0.18 mg·1−1. The method has been successfully applied to the determination of manganese in standard steel samples, natural water samples and plant material.  相似文献   

12.
Hydroxyl radicals were generated radiolytically in N2O-saturated aqueous solutions of the aminoglycoside antibiotic, gentamycin. Using the pulse radiolysis technique, the rate constant of OH radicals with gentamycin determined was 1.2·109 dm3·mol−1·s−1. Upon.OH attack a transient species with an absorption maximum at 270 nm is observed which decays by second-order kinetics within the solute concentration range of 3.2·10−5 to 1·10−3mol·dm−3. Transient species undergoes transformation to a permanent product absorbing between 260 and 340 nm with maximum absorption at 300 nm. Rate constant of the reaction of bimolecular decay of gentamycin radicals, k (Gen.+Gen.) was found to be ≈ 1.4·107 dm3·mol−1·s−1.  相似文献   

13.
Summary An HPLC method was developed for determination of amoxicillin, penicillin G, penicillin V, ampicillin, oxacillin, cloxacillin, nafcillin and dicloxacillin in serum from pigs and cattle. Serum was cleaned up by solid-phase extraction (SPE), ultra-filtered and derivatised. The method was linear in the range tested up to 2000 ng mL−1 of individual penicillins in serum. Limits of detection were 11–14 ng mL−1. Mean recoveries were 90–103% in the range 20–2000 ng mL−1. The relative repeatability, standard deviation was <10% at 20 ng mL−1 level and <6% in the range 100–2000 ng mL−1.  相似文献   

14.
A combined method involving electrochemical oxidation of iodide to iodate at a platinum electrode followed by extraction in CCl4 of ionic associates of iodine-iodide complexes with brilliant green, formed in excess of iodide, was developed for the spectrophotometric quantification of iodide. The slope of the calibration curve yields a molar extinction coefficient of ɛ = 3·105 L mol−1cm−1. This method can be used for the quantification of iodide in the concentration range of 3·10−7 − 3·10−6 mol L−1 with a detection limit of 5·10−8 mol L−1. The interfering effect of other ions on the determination of the iodide concentration was also investigated. The method was successfully applied for the determination of iodide in real samples of NaCl and spring water. Relative standard deviation is 1–2%.  相似文献   

15.
A sensitive adsorptive anodic stripping procedure for the determination of trace zirconium at a carbon paste electrode (CPE) has been developed. The method is based on adsorptive accumulation of the Zr(IV)-alizarin red S(ARS) complex onto the surface of the CPE, followed by oxidation of adsorbed species. The optimal experimental conditions include the use of 0.10 mol · L−1 ammonium acetate buffer (pH 4.3), ARS, an accumulation potential of 0.20 V (versus SCE), an accumulation time of 2 min, a scan rate of 200 mV · s−1 and a second-order derivative linear scan mode. The oxidation peak for the complex appears at 0.69 V. The peak current is proportional to the concentration of Zr(IV) over the range of 1.0 × 10−9–2.0 × 10−7 mol · L−1, and the detection limit is 3 × 10−10 mol · L−1 for a 2 min adsorption time. The relative standard deviations (n = 8) for 5.0 × 10−8 and 5.0 × 10−9 mol · L−1 Zr(IV) are 3.3 and 4.8%, respectively. The proposed method was applied to the determination of zirconium in ore samples with satisfactory results.  相似文献   

16.
This article demonstrates the potential of encapsulated, engineered Lactococcus lactis as a vehicle for the oral delivery of therapeutic proteins. Using alginate-poly-l-lysine-alginate membrane-encapsulated L. lactis engineered to secrete the reporter protein Staphylococcal aureus nuclease, we show comparable viability and protein secretion between free and immobilized cells. After 12 h, microcapsules with a cell density of 4.8 × 105 colony forming unit (CFU) ml−1 grew to 2.2 × 108 CFU ml−1 and released 0.24 arbitrary unit (AU) ml−1 of nuclease, producing similar results as free cells, which grew from 3.4 × 105 to 1.9 × 108 CFU ml−1 and secreted 0.21 AU ml−1 of nuclease. Moreover, encapsulated cells at a density of 4.4 × 107 CFU ml−1 grew to 2.2 × 1010 CFU ml−1 in 12 h and secreted 15.3 AU ml−1 of nuclease although 3.1 × 107 CFU ml−1 of free cells reached only 2.3 × 109 CFU ml−1 and released 5.6 AU ml−1 of nuclease. We also show the sustained stability of the microcapsules during storage at 4°C over 8 weeks.  相似文献   

17.
In determining the trace impurities existing in high-purity rare earth samples by the neutron activation analysis, there are much interference due to nuclides induced from neutron induced second order nuclear reaction. This paper presents the degree of interference calculated over the ranges of irradiation time from 105 to 107 sec and of thermal-neutron flux from 1·1012 to 1·1015 n·cm−2·sec−1. According to the results of these calculations, degree of interference under the neutron irradiation condition for 288 hrs in the thermal-neutron flux of 3·1013n·cm−2·sec−1 is concluded to be 6.4·106 ppm Gd in Eu, 2.2·104 ppm Sm in Eu, 1.9·104 ppm Ho in Dy, 1.1·103 ppm Eu in Sm, 1.1·102 ppm Ce in La and 1.1·10 ppm Tb in Gd, respectively. Especially, the Gd determination in the Eu target is extremely affected by153Gd formed from the151Eu (n, γ) reaction. On the contrary, this reaction is effective in producing153Gd activity.  相似文献   

18.
In order to determine traces of boron, silicon and sulfur, B(18O, x)27Mg, Si(18O, x)43Sc and S(18O, x)47V reactions have been investigated between 15 and 44MeV. At 34 MeV, only a few of the systematically identified nuclear interferences produce27Mg and the detection limit is 30ng boron for a 10 minute irradiation with a 0.3μA·cm−2 oxygen-18 beam. Silicon analysis has shown nuclear interferences from Al, P and K; interference-free detection limit is 80 ng silicon for an hour irradiation with a 0.4 μA·cm−2 beam at 39 MeV. There is no nuclear interference for the sulfur determination and the detection limit is 5 ng sulfur for a 30 minutes irradiation with a 0.5 μA·cm−2 beam at 39 MeV. Thus a selective and sensitive sulfur determination can be achieved.  相似文献   

19.
Utilizing the fascinating properties of montmorillonite calcium (MMT-Ca), such as huge cationic exchange capacity, strong adsorptive ability, high chemical and mechanical stability, an MMT-Ca modified carbon paste electrode (CPE) was constructed for the sensitive determination of Pb2+. In 0.01 mol·L−1 HCl, Pb2+ was firstly exchanged and accumulated on an MMT-Ca modified CPE surface and secondly reduced to Pb at −0.90 V. In the following potential sweep from −0.90 to −0.50 V, reduced Pb was oxidized, resulting in an obvious stripping peak at −0.58 V. After optimizing the parameters, such as determining medium, content of MMT-Ca, accumulation potential and time, an electrochemical method was developed for the analysis of Pb2+. Compared with bare CPE, the MMT-Ca modified CPE significantly enhances the sensitivity of Pb2+ analysis. The limit of detection is evaluated to be 6.0 × 10−9 mol L−1 Pb2+. Finally, this method was successfully employed to determine trace levels of Pb2+ in water samples. The first two authors contribute equally do this work  相似文献   

20.
A collimated neutron beam capable of providing a thermal neutron flux of 4.75·107 n·cm−2·sec−1 has been used to analyze alloy samples of 1–5 g during relatively short irradiation times of 30 min by the use of neutron capture gamma-ray spectrometry. The analyses were performed by using a mathematical treatment that relates the count ratio of every constituent present in the matrix with the concentration and thus it requires no standards. The technique was applied to the analysis of steel and gold alloy samples. Errors ranged from 0.8%–10%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号