首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
A novel and rapid procedure based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the determination of dialkyl phosphates (metabolites of organophosphorus pesticides) in human urine has been developed. After addition of 40 mM tetrabutylammonium acetate, 10 microL of urine sample were directly injected into the LC/MS/MS system. The method was validated yielding calibration curves with correlation coefficients greater than 0.997 and repeatability coefficient of variation (CV) lower than 9%. The accuracy and precision were evaluated by direct injection of spiked samples at 10 and 100 microg/L obtaining recoveries between 78 and 119% with coefficients of variation below 12%. Limits of detection of 1 microg/L for diethyl phosphate (DEP), diethylthiophosphate (DETP) and diethyldithiophosphate (DEDTP) and 2 microg/L for dimethyldithiophosphate (DMDTP) were achieved, all the analytes being detected in negative ion mode. The fragmentation pathway of dialkyl phosphates allowed us the use of an additional transition for confirmation in order to improve their identification in real-world samples. The applicability of the LC/MS/MS method was demonstrated by applying it to the analysis of urine samples of farmers exposed to the organophosphorus pesticide chlorpyrifos. Good correlation between application of the product in the field (citrus orchards), concentration levels of dialkyl phosphates and levels of the chlorpyrifos-specific metabolite (1,3,5-trichloro-2-pyridinol) was obtained.  相似文献   

5.
A fast screening method is presented for detecting isopropylthioxanthone (ITX) contamination in milk. The method is based on direct high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) analysis of milk samples. Sample preparation is limited to the addition of a deuterated ITX solution in acetonitrile that serves both as internal standard and to precipitate proteins. The method is highly accurate and sensitive. Isomeric specific analyses of 2-ITX and 4-ITX are possible at 6 microg/L levels with about 5% precision and accuracy. This approach has been used to check contamination in samples like milk, soy milk, baby milk, in their packaging material. Out of 37 milk samples analyzed, 16 were positive with concentrations ranging from 173-439 microg/L for 2-ITX and from <6 (lower than limit of quantification) to 25 microg/L for 4-ITX.  相似文献   

6.
A precise and accurate stable isotope dilution liquid chromatography/tandem mass spectrometry method for the analysis of intracellular homocysteine has been developed. An internal standard, [(2)H(8)]-homocystine, was added to cell pellets from EA.hy 926 cells grown in culture under low and high folate concentrations. D,L-dithiothreitol was used to reduce cellular homocystine to homocysteine. Cellular proteins were precipitated by the addition of formic acid in acetonitrile. After centrifugation, a portion of the supernatant was analyzed by liquid chromatography/tandem mass spectrometry. Using a Supelcosil cyano column with an Applied Biosystems API 4000 triple quadrupole mass spectrometer, the SRM transitions for homocysteine (m/z 136 to m/z 90) and [(2)H(4)]-homocysteine (m/z 140 to m/z 94) were monitored. The method was validated by conducting five replicate analyses on three different days at four different concentrations (concentrations at the lower limit of quantitation and expected lower quartile, mid-range and upper quartile). The limit of detection was 2 ng/10(6) EA.hy 926 cells. Using this method, the intracellular homocysteine concentration in EA.hy 926 cells ranged from 10 to 36 ng/10(6) cells.  相似文献   

7.
Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human plasma samples was developed. The absolute minimum detection limit was around 10-20 pg per injection, corresponding to 0.5 ppb in an injection equivalent to 20-40microg of human plasma. Ochratoxin B (OTB) was used as an internal standard and its absence in real-life samples was carefully checked before samples were spiked with the internal standard. It was found that these two ochratoxins are susceptible to sodium adduct formation. Fragment ions from the [M + H](+) and [M + Na](+) ions of both OTA and OTB were monitored in the multiple reaction monitoring mode. Three quantitative approaches, standard addition method, internal standard method (using ochratoxin B as an internal standard) and external standard method, were compared in the analysis of human blood plasma. Results from the mass spectrometric method were comparable to those from a conventional LC/fluorescence method. The LC/MS/MS method was also applied to the analysis of contaminated coffee samples.  相似文献   

8.
In the present study, a simple and rapid method for metamizole metabolite 4-methylamino antipyrine (MAA) determination in human plasma was developed, validated and successfully applied to a clinical trial. Chromatographic separation was achieved in HILIC mode on a YMC-Pack SIL column (100 × 2.0 mm; S-5 μm, 30 nm), with a mobile phase consisting of acetonitrile, water and formic acid. Protein precipitation of a small plasma volume using acetonitrile was selected for sample preparation. The multiple reaction monitoring transitions in the positive ionization mode were m/z 218.2 → 56.2 for MAA and m/z 221.2 → 56.2 for MAA-d3 (IS, internal standard). Concentration levels of MAA calibration standards were in the range of 0.100–20 μg/ml. Metamizole conversion into MAA in both water and organic media was investigated, and the level of the conversion in commercially available injection solutions was estimated.  相似文献   

9.
A direct, simple, and simultaneous determination of acylcarnitines in amniotic fluid was developed using column-switching liquid chromatography/tandem mass spectrometry (LC/MS/MS). The analytes can be assayed within 20 min without any sample preparation process, and we monitored separated acylcarnitines with positive electrospray ionization (ESI)-MS/MS. The calibration ranges of acylcarnitines were 1 to 100 nmol/L. The linearity of the method was 0.992 to 0.999, and the limits of detection at a signal-to-noise ratio of 3 were 1 nmol/L. The coefficients of variation were in the range of 5.2 to 13.3% for within-day variation and 6.7 to 11.9% for day-to-day, respectively. We detected acylcarnitines in the amniotic fluid of 22 women in the early stages of their pregnancies in the range of 2.2 to 17.2 nmol/L. The proposed method could be applied to diagnosis, monitoring, and biomedical investigations of inborn errors of the organic acid and fatty acid metabolism of the embryo.  相似文献   

10.
A method is described for the determination of 16 sulfonamides in honey. Samples are dissolved in phosphoric acid solution (pH2), cleaned up with 2 solid-phase extraction (SPE) cartridges, an aromatic sulfonic cation-exchange cartridge and an Oasis HLB SPE cartridge, and analyzed both qualitatively and quantitatively by liquid chromatography/tandem mass spectrometry (LC/MS/MS) under the selected conditions. Without exception, calibration curves were linear (r = > 0.995), when sulfamethizole was between 1.0 and 25.0 microg/kg; sulfacetamide, sulfapyridine, sulfadiazine, sulfachloropyridazine, sulfamethoxazole, sulfamerazine, sulfisoxazole, sulfamonomethoxine, and sulfadoxine were between 2.0 and 50.0 microg/kg; sulfamethoxypyridazine, sulfadimethoxine, and sulfathiazole were between 4.0 and 100.0 microg/kg; sulfamethazine and sulfameter were between 8.0 and 200.0 microg/kg; and sulfaphenazole was between 12.0 and 300.0 microg/kg. Average recoveries at 4 fortification levels in the range of 1.0-300 microg/kg in honey were 70.9-102.5%, and relative standard deviations were 2.02-11.52%. The limits of quantitation for the 16 sulfonamides were between 1.0 and 12.0 microg/kg, with the LC/MS/MS method.  相似文献   

11.
In early 2007 it was determined that the compound melamine, suspected of having been involved in the deaths of numerous pets, had been fed to hogs intended for human consumption. This report describes a method for the analysis of melamine in porcine muscle tissue using solid-phase extraction (SPE) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Melamine was extracted in 50% acetonitrile in water. Homogenates were centrifuged and supernatants were acidified and washed with methylene chloride. The aqueous extracts were cleaned up using mixed-mode C8/strong cation exchange SPE and then concentrated, fortified with a stable isotope-labeled analog of melamine, and analyzed by HPLC/MS/MS. Gradient HPLC separation was performed using an ether-linked phenyl column with ammonium acetate/acetic acid and acetonitrile as the mobile phase. Multiple reaction monitoring (MRM) mode of two precursor-product ion transitions for melamine and one for the internal standard was used. A five point calibration curve ranging from 50 to 2000 ng/mL of melamine in solvent was used to establish instrument response. The method was validated by analysis of seven replicate porcine muscle tissue samples fortified with 10 ng/g of melamine. The mean recovery for the seven replicates was 83% with 6.5% relative standard deviation and the calculated method detection limit was 1.7 ng/g.  相似文献   

12.
Sparfloxacin, a fluoroquinolone antibiotic, is used for the treatment of bacterial infection. A quantification method using mass spectrometry was developed for the determination of sparfloxacin in rat plasma. After simple protein precipitation with acetonitrile, the analytes were chromatographed on a reversed‐phase C18 column and detected by liquid chromatography/tandem mass spectrometry with electrospray ionization. The accuracy and precision of the assay were in accordance with FDA regulations for validation of bioanalytical methods. This method was applied to measure the plasma sparfloxacin concentrations after a single oral administration of sparfloxacin in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
A rapid multiresidue method for the analysis of more than 40 herbicides (such as simazine, terbuthylazine and diuron) in waters has been developed and validated by ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC/MS/MS). Prior to chromatographic determination, the samples were extracted using a solid-phase extraction procedure. The analysis was performed on an Acquity UPLC BEH C(18) column using a gradient elution profile and a mobile phase consisting of methanol and an aqueous solution of formic acid (0.01%). Other chromatographic and MS/MS parameters were optimised in order to improve selectivity and sensitivity of the analytes. The analytes were detected using electrospray ionisation (ESI)-MS/MS in positive ion mode with multiple reaction monitoring (MRM), optimising parameters such as voltage cone, capillary voltage, source and desolvation temperature, and desolvation and cone gas flow. The optimised method provides a rapid separation (less than 10 min) of the selected herbicides in the assayed matrices, and it was validated by the analysis of spiked blank matrix samples. Good linearity was obtained and the repeatability of the method was less than 20% for the lowest calibration point. The limits of detection ranged from 0.002 to 0.02 microg/L, and the limits of quantification from 0.005 to 0.05 microg/L, which were below the values specified by the European Union. Finally, the method was successfully applied to real environmental samples from Andalusia (southern Spain). Terbuthylazine, simazine, atrazine desisopropyl and desethyl terbuthylazine were the herbicides most frequently found in water samples.  相似文献   

14.
We developed a rapid and efficient means of determining residues of four nitroimidazoles-i.e., dimetridazole, ipronidazole, metronidazole, and ronidazole-and three hydrophilic metabolites- i.e., 2-hydroxymethyl-1-methyl-5-nitroimidazole, 1 -methyl-2-(2'-hydroxyisopropyl)-5-nitroimidazole, and 1-(2-hydroxyethyl)-2-hydroxymethyl-nitroimidazole--in honey. We applied a QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) procedure improved to suit a nitroimidazole analysis, which is fast (approximately 30 min) and uses less organic solvent. The procedure involves initial single-phase extraction of 5 g of honey with acetonitrile containing 1% acetic acid, followed by liquid-liquid partitioning involving the addition of 5 g sodium chloride, 1.5 g trisodium citrate dihydrate, and 4 g magnesium sulfate. Moreover, matrix from honey was reduced by an SPE method with an alumina-N cartridge. The samples were analyzed using LC/MS/MS. Chromatographic separation of these nitroimidazoles and metabolites was performed in the gradient mode on a pentafluorophenylpropyl-bonded silica column (150x2.0 mm, 3 pm particle size) at 40 degrees C. The mobile phase consisted of a 0.01% acetic acid solution and acetonitrile, and the flow rate was 0.2 mL/min. The method was validated using honey spiked with these nitroimidazoles from 0.1 to 0.5 microg/kg. The overall recovery of the seven nitroimidazoles ranged from 76.1 to 98.5%; intra- and interassay CV values were <9.5 and <14.2%, respectively. The LOQ ranged from 0.1 to 0.5 microg/kg. LC/MS/MS coupled with the QuEChERS method showed good potential as a method for determining nitroimidazole residues in honey.  相似文献   

15.
A simple, fast, and robust method was developed for the determination of fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3) in corn-based human food and animal feed (cornmeal). The method involves a single extraction step followed by centrifugation and filtration before analysis by ultra-performance liquid chromatographylelectrospray ionization (UPLC/ESI)-MS/MS. The LC/MS/MS method developed here represents the fastest and simplest procedure (<30 min) among both conventional HPLC methods and other LC/MS methods using SPE cleanup. The potential for high throughput analysis makes the method particularly beneficial for regulatory agencies and analytical laboratories with a high sample volume. A single-laboratory validation was conducted by testing three different spiking levels (200, 500, and 1000 ng/g for FB1 and FB2; 100, 250, and 500 ng/g for FB3) for accuracy and precision. Recoveries of FB1 ranged from 93 to 98% with RSD values of 3-8%. Recoveries of FB2 ranged from 104 to 108%, with RSD values of 2-6%. Recoveries of FB3 ranged from 94 to 108%, with RSD values of 2-5%.  相似文献   

16.
High-throughput chiral liquid chromatography/tandem mass spectrometry   总被引:3,自引:0,他引:3  
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments.  相似文献   

17.
A method is proposed for the detection and confirmation of the presence of beta-blockers and their metabolites in fivefold diluted human urine samples by ultra performance liquid chromatography coupled with electrospay ionization tandem mass spectrometry. The limits of detection for most of compounds are 5–10 ng/mL. A substantial effect of ionization suppression was observed. The determination of metabolites and glucuronides of beta-blockers without additional derivatization and extraction is described for the first time.  相似文献   

18.
This paper describes a new method for the sensitive and selective determination of fosetyl-aluminum (Al) residues in vegetable samples. The method involves extraction with water by using a high-speed blender and subsequent injection of the 5-fold diluted extract into the liquid chromatograph. Fosetyl-Al is determined by liquid chromatography with electrospray tandem mass spectrometry after the addition of tetrabutylammonium acetate as the ion-pairing reagent. The method has been used to assay lettuce samples spiked at 2 and 0.2 mg/kg. Recoveries were satisfactory, with mean values of 98 and 106%, respectively, and relative standard deviations were < 10%. The limit of quantitation was 0.2 mg/kg, and the limit of detection was as low as 0.05 mg/kg. Matrix-matched calibration was used for quantitation, and the addition of an internal standard improved repeatability. The developed method allows the accurate and rapid determination of low levels of fosetyl-Al residues in lettuce with very little sample handling and good sensitivity; it was shown to be robust by the analysis of almost 100 samples.  相似文献   

19.
In conjunction with an AOAC Task Group on dietary supplements, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was validated for measurement of 6 major alkaloids in raw ephedra sinica herb, ephedra extracts, ephedra tablets, complex dietary supplements containing ephedra, and a high-protein drink mix containing ephedra. The amount of ephedrine-type alkaloids present was determined by LC with mass selective detection. Six replicates of each matrix were analyzed on 3 separate occasions. The presence of 6 ephedrine-type alkaloids was detected at a level > 0.5 microg/g based on a 0.5 g sample. The standard curve range for this assay is from 0.02 to 1.0 microg/mL. Appropriate dilutions covered a wide range of specific alkaloid concentrations. The calibration curves for all 6 analytes had correlation coefficients > 0.995.  相似文献   

20.