首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
Automated methods of PDMS/β‐CD/divinylbenzene‐coated stir plate sorptive extraction (SPSE) coupled to HPLC‐fluorescence detector were reported for the first time. Three automation modes, static SPSE, circular flow SPSE and continuous flow SPSE, were evaluated and critically compared with stir bar sorptive extraction by using six polycyclic aromatic hydrocarbons as model analytes. It was found that the operable sample volume for circular flow SPSE and continuous flow SPSE was larger than that for static SPSE. Under the same extraction conditions, continuous flow SPSE exhibited the highest extraction efficiencies in all automated modes and manual stir bar sorptive extraction for the target compounds. Compared with the manual operation (approximately 5–10 min), automated SPSE required a relatively short time (117–180 s) to finish sampling, washing and sample loading. Besides being labor‐saving and time‐saving, automated SPSE has other advantages, such as no time limit and non‐attended operation. The proposed continuous flow PDMS/β‐CD/divinylbenzene‐coated SPSE‐HPLC‐fluorescence detector was successfully applied to environmental water analysis.  相似文献   

2.
This review outlines automated methodologies developed for measuring arsenic in environmental samples. We report the state of the art of the most significant methods exploiting multicommutation flow techniques coupled to hydride generation-atomic fluorescence determination. We review analytical methods used and present a comparative evaluation of them. We also discuss the on-line pre-concentration procedure as being of particular interest in the development of fully automated methods.  相似文献   

3.
4.
Dysfunction of P/Q-type calcium channels is thought to underlie a variety of neurological diseases. There is evidence that migraine, Alzheimer's disease, and epilepsy involve a gain-of-function of the channel, leading to abnormal presynaptic vesicle release. P/Q-channel blockers may normalize current flow and consequently lead to an alleviation of disease symptoms. Although the medical need is high, there are no such compounds on the market. Here we describe a high throughput screen (HTS) for P/Q-type calcium channel blockers and the confirmation of hits by automated electrophysiology. We generated a HEK293 cell line stably expressing the α1A subunit of the P/Q-type calcium channel under control of a tetracycline (Tet) promoter. The accessory β1.1 and α2δ1 subunits were co-expressed constitutively. The cell line was pharmacologically characterized by ion channel specific modulators, and revealed functional P/Q-type calcium currents. Using a fluorescence imaging plate reader (FLIPR), an assay for P/Q-type calcium channels was established based on a calcium sensitive dye. HTS of a 150,000 compound-containing sub-library led to the identification of 3262 hits that inhibited the fluorescence signal with potencies below 10 μM. Hit-to-lead (HTL) efforts identified 12,400 analogues. Compounds were clustered into 37 series, and 8 series of interest were prioritized. An electrophysiological secondary screen, providing a more direct measure of channel function, was implemented into the HTL process. 27 selected exemplars of different chemotypes were validated by automated whole-cell patch clamp analysis at inactivated channel state. The discovery of P/Q-channel blockers may foster the development of new therapeutics for a variety of neurological diseases.  相似文献   

5.
6.
An improved assay for the determination of rofecoxib in human plasma samples is described. The analyte and an internal standard were extracted from the plasma matrix using solid-phase extraction in the 96-well format with an Empore C8-SD extraction plate. The analytes are chromatographed on a Waters Symmetry C18 analytical column (3.5 microm, 50x4.6 mm) with a mobile phase consisting of acetonitrile-water (35:65, v/v). Analyte detection was via fluorescence following post-column photochemical derivatization. Eight point calibration curves over the concentration range of 0.5-80 ng/ml yielded a linear response when a 1/y weighted linear regression model was employed. Based on the replicate analyses (n=5) of spiked standards, the within-day assay precision was better than 8% RSD at all points on the calibration curve, within-day accuracy was within 6% of nominal at all standard concentrations. The between-run precision and accuracy of the assay, as calculated from the results of the analysis of quality control samples, was better than 7% RSD and within 5% of nominal. Assay throughput was improved by a factor of three as compared to previously described methods. The method was partially automated using a combination of a Packard Multi-Probe liquid handling system and a TomTec Quadra 96 workstation.  相似文献   

7.
Fluorescence detection has been a method of choice in industry for screening assays, including identification of enzyme inhibitors, owing to its high-throughput capabilities, excellent reproducibility, and sensitivity. Occasionally, inhibitors are identified that challenge the fluorescence assay limit, necessitating the development of more sensitive detection methods to assess these compounds. For data mining purposes, however, original assay conditions may be required. A direct method transfer to highly sensitive and specific LC-MS-based methods has not always been possible due to the presence of MS-incompatible neutral detergents and non-volatile salts in the assay matrix. Utilizing an in vitro proteolytic screening assay for the serine protease hepatitis C virus (HCV) nonstructural (NS) 3 protease as a test case, we report the development of an automated sample clean-up procedure implemented on-line with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis to complement fluorescence detection. Ion exchange and peptide microtraps were employed to remove MS-incompatible assay matrix components. Three protease inhibitors were used to validate the MS/MS method. Comparable potencies were achieved for these compounds when assessed by fluorescence and MS/MS detection. Furthermore, four-fold less enzyme could be utilized when employing the MS/MS method compared to fluorescence detection. The longer analysis time, however, resulted in reduced sample capacity. The potency of our designed HCV NS3 protease inhibitors are thus routinely evaluated using a continuous fluorescence-based assay. Only pertinent inhibitors approaching the fluorescence assay sensitivity limit are subsequently analyzed further by LC-MS/MS. This methodology allows us to maintain a database and to compare results independent of the detection method. Despite the relatively slow sample turnaround time of this LC-MS approach, the versatility of the automated on-line clean-up procedure and sample analysis can be applied to assays containing reagents which were historically considered to be MS incompatible.  相似文献   

8.
An improved automated continuous sample introduction system for microfluidic capillary electrophoresis (CE) is described. A sample plate was designed into gear-shaped and was fixed onto the shaft of a step motor. Twenty slotted reservoirs for containing samples and working electrolytes were fabricated on the “gear tooth” of the plate. A single 7.5-cm long Teflon AF-coated silica capillary serves as separation channel, sampling probe, as well as liquid-core waveguide (LCW) for light transmission. Platinum layer deposited on the capillary tip serves as the electrode. Automated continuous sample introduction was achieved by scanning the capillary tip through the slots of reservoirs. The sample was introduced into capillary and separated immediately in the capillary with only about 2-nL gross sample consumption. The laser-induced fluorescence (LIF) method with LCW technique was used for detecting fluorescein isothiocyanate (FITC)-labeled amino acids. With electric-field strength of 320 V/cm for injection and separation, and 1.0-s sample injection time, a mixture of FITC-labeled arginine and leucine was separated with a throughput of 60/h and a carryover of 2.7%.  相似文献   

9.
A fully automated analytical method was developed for the online in situ analysis of selected semi-volatile organic compounds in water. The method used a large-volume injection/gas chromatography/mass spectrometry coupled with a fully automated microscale solid-phase extraction technique, which was based on x-y-z robotic techniques. Water samples were extracted by using a 96-well solid-phase extraction plate. For most analytes included in this study, the obtained linear calibrations ranged from 0.05 to 5.0 microg/L with correlation coefficients of 0.996-1.000, the method detection limits were less than 0.1 microg/L, and the relative recoveries were in the range of 70-120% with a relative standard deviation of less than 15% for fortified reagent water samples. The applications to chlorinated tap water, well water, and river water have been validated. The obtained results were similar to those resulting from fortified reagent water samples for all analytes except metribuzin, bromacil, aldrin, and methoxychlor. Matrix effects were observed for these analytes. In general, this fully automated analytical method was rugged, reliable, and easy to operate, and was capable of providing real-time data to water treatment and distribution systems as well as water reservation and protection systems. In addition, the method could reduce the analytical costs associated with sample collection, transportation, storage, and preparation.  相似文献   

10.
A high-throughput method for viscosity measurement was developed and tested for nanocomposite sols with an easy-to-clean (ETC) effect. The method is based on doping of sols with viscosity sensitive fluorescent dye 4,4′-bis-(2-benzoxazolyl)-stilbene (BOS) and acquisition of fluorescence intensity data. The spectroscopic data were correlated with viscosity data derived from mechanical measurements with a rotational viscometer and show an exponential correlation of both mechanical and spectroscopic measurement methods in the relevant data space of 3–5 mPa·s. For application of the spectroscopic viscosity measurement as a high-throughput assay doping of sols with BOS slurry was carried out with an automated liquid handling system, and spectroscopic measurements were performed with a fluorescence microplate reader.  相似文献   

11.
12.
Automated structure verification using 1H NMR data or a combination of 1H and heteronuclear single‐quantum correlation (HSQC) data is gaining more interest as a routine application for qualitative evaluation of large compound libraries produced by synthetic chemistry. The goal of this automated software method is to identify a manageable subset of compounds and data that require human review. In practice, the automated method will flag structure and data combinations that exhibit some inconsistency (i.e. strange chemical shifts, conflicts in multiplicity, or overestimated and underestimated integration values) and validate those that appear consistent. One drawback of this approach is that no automated system can guarantee that all passing structures are indeed correct structures. The major reason for this is that approaches using only 1H or even 1H and HSQC spectra often do not provide sufficient information to properly distinguish between similar structures. Therefore, current implementations of automated structure verification systems allow, in principle, false positive results. Presented in this work is a method that greatly reduces the probability of an automated validation system passing incorrect structures (i.e. false positives). This novel method was applied to automatically validate 127 non‐proprietary compounds from several commercial sources. Presented also is the impact of this approach on false positive and false negative results. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
Capillary electrophoretic analysis of individual submicrometer size particles has been previously done using custom-built instruments. Despite that these instruments provide an excellent signal-to-noise ratio for individual particle detection, they are not capable of performing automated analyses of particles. Here we report the use of a commercial Beckman P/ACE MDQ capillary electrophoresis (CE) instrument with on-column laser-induced fluorescence (LIF) detection for the automated analysis of individual particles. The CE instrument was modified with an external I/O board that allowed for faster data acquisition rates (e.g. 100 Hz) than those available with the standard instrument settings (e.g. 4 Hz). A series of eight hydrodynamic injections expected to contain 32 +/- 6 particles, each followed by an electrophoretic separation at -300 V cm(-1) with data acquired at 100 Hz, showed 28 +/- 5 peaks corresponding to 31.9 particles as predicted by the statistical overlap theory. In contrast, a similar series of hydrodynamic injections followed by data acquisition at 4 Hz revealed only 8 +/- 3 peaks suggesting that the modified system is needed for individual particle analysis. Comparison of electropherograms obtained at both data acquisition rates also indicate: (i) similar migration time ranges; (ii) lower variation in the fluorescence intensity of individual peaks for 100 Hz; and (iii) a better signal-to-noise ratio for 4 Hz raw data. S/N improved for 100 Hz when data were smoothed with a binomial filter but did not reach the S/N values previously reported for post-column LIF detection. The proof-of-principle of automated analysis of individual particles using a commercially available CE system described here opens exciting possibilities for those interested in the study and analyses of organelles, liposomes, and nanoparticles.  相似文献   

14.
This investigation is based on the automated solid phase microextraction GC-MS analysis of the volatile fraction of a variety of coffee bean matrices. Volatile analytes were extracted by headspace (HS)-SPME which was achieved with the support of automated instrumentation. The research was directed towards various important aspects relating to coffee aroma analysis: monitoring of the volatile fraction formation during roasting; chromatographic differentiation of the two main coffee species (Arabica and Robusta) and of a single species from different geographical origins; evaluation of the influence of specific industrial treatments prior to roasting. Reliable peak assignment was carried out through the use of a recently laboratory-constructed "flavour and fragrance" library and a dual-filter MS spectral search procedure. Further emphasis was placed on the automated SPME instrumentation and on its ability to supply highly repeatable chromatographic data.  相似文献   

15.
The laterally resolved analysis of the chemical surface composition of surface-treated block copolymers by atomic force microscopy (AFM) pull-off force mapping in the force volume (FV) mode and the automated analysis of the FV data is discussed. Poly(tert-butyl acrylate) (PtBA) microdomains residing in a polystyrene (PS) matrix at the surface of cyclohexane-treated polystyrene-block-poly(tert-butyl acrylate) (PtBA-b-PS) block copolymer thin films were domain-selectively deprotected, activated and chemically modified, as also shown by fluorescence microscopy. AFM pull-off force mapping in conjunction with an automated analysis of the data provided real space evidence for the successful conversion of reactive esters located in the PtBA domains and showed that AFM and related approaches, such as chemical force microscopy (CFM), can indeed contribute to assess changes in heterogeneous surface chemical composition of polymers down to sub-50 nm length scales.  相似文献   

16.
High Content Screening (HCS), a combination of fluorescence microscopic imaging and automated image analysis, has become a frequently applied tool to study test compound effects in cellular disease-modelling systems. In this work, we compared a confocal and a non-confocal cellular HCS system, the IN Cell Analyzers(1) 3,000 and 1,000, respectively. As a cellular model system we used the Transfluor technology in the 384-well microtiter plate (MTP) format. The Transfluor HCS assay for G-protein coupled receptor (GPCR) activation is based on the recruitment of a green fluorescent protein-labelled arrestin (ArrGFP) from the cytosol to the plasma membrane. We investigated two GPCRs, the wild-type (wt) beta2 adrenergic receptor (beta2AR) and the beta2AR-enhanced (E), a C-terminally mutated receptor with a higher affinity to arrestin. Upon agonist stimulation, the beta2AR-wt induced the redistribution of ArrGFP to coated pits, the beta2AR-E maintained the interaction with ArrGFP down to the formation of endocytic vesicles. Our findings reveal that the assay is feasible on both instruments, with sufficiently robust Z' statistics. Improved Z' statistics, though, are achieved with the confocal system, particularly in case of weak signals. Moreover, throughput is dramatically higher for the IN Cell Analyzer 3,000. We conclude that, depending on the needs for throughput and assay biology, either instrument may fulfil a successful role in the drug discovery process. Confocal optics, however, provide a better basis for the detection of smaller subcellular structures with lower fluorescence intensity.  相似文献   

17.
A novel strategy to evaluation of adulteration in alcoholic beverages based on the measurement of the Schlieren effect using an automated FIA system with photometric detection is proposed. The assay is based on the Schlieren effect produced when beverage samples are injected in a single-line FIA system that uses water as carrier stream and a light-emitting diode-phototransistor photometer controlled by microcomputer as detector. The flow system presents limited mixing conditions which make possible to create gradients of refractive index (Schlieren effect) in the injected sample zone. These gradients are reproducible, characteristic of each alcoholic beverage and undergo specific modifications when adulterations with water or ethanol are imposed. Schlieren effect data of brandies, cachaças, rums, whiskies and vodkas were treated by SIMCA to elaborate class models applied in the evaluation of alcoholic beverages adulteration. Samples of the original matrix of each sort of beverages were adulterated in laboratory by adding water, methanol and ethanol in levels of 5% and 10% (v/v). These samples were used as test set to validate SIMCA class models. The verification of authenticity using Schlieren effect measurements presented good results making possible to identify 100% of the beverages samples adulterated in laboratory and 93% of the actual adulterated alcoholic beverages with confidence levels of 95%. As principal advantage, the automated system does not use reagents to carry out the analysis.  相似文献   

18.
Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) still remains the most reliable and comprehensive analytical method for the evaluation of protein extracts. However, conventional SDS-PAGE is time-consuming and, thus, unpractical if several tens or hundreds of samples must be examined. We show that SDS-PAGE protein analysis can be automated using slab gel DNA sequencers and compare the instrument's performance with conventional SDS-PAGE in terms of resolution, sensitivity and sample capacity. Labeled protein bands are detected online by laser-induced fluorescence (LIF) and the acquired signals are electronically stored for further processing, avoiding gel staining and scanning. Appropriate software allows immediate display of recorded data and convenient evaluation. The method provides a higher sensitivity and dynamic range than conventional Coomassie-stained gels and the resolution of proteins with different masses is independent of the polyacrylamide concentration. Internal markers can also be used for direct quantification and assignment of the molecular masses. Additionally, we present a novel electrophoresis instrument for the simultaneous separation and online LIF detection of all samples of a microtiterplate in parallel lanes in a 3-D geometry gel cylinder. The specific gel thermostatting concept prevents irregular sample migration (smiling) and improves the reproducibility and comparability of individual separation patterns. In combination with the expected large capacity of 384 or 1,536 samples, this makes the instrument a valuable tool for high-throughput comparative screening applications.  相似文献   

19.
The phytochemical study of Duguetia moricandiana Mart. (Annonaceae) yielded the isolation of the alkaloid which was identified by spectral analysis as discretamine. The evaluation of antinociceptive activity carried out by the acetic acid-induced writhing, formalin and hot plate tests in mice, suggests a potent antinociceptive effect. Discretamine (5, 10 and 20?mg?kg?1, i.p.) significantly reduced the number of writhes similarly at all doses tested and the number of paw licks during the first phase of formalin test when compared to control. The effect of discretamine on hot plate response provides a confirmation of its central effect. These results indicate antinociceptive properties of this alkaloid.  相似文献   

20.
A totally automated and reliable high-performance liquid chromatographic method is described for the routine determination of free catecholamines (norepinephrine, epinephrine and dopamine) in urine. The catecholamines were isolated from urine samples using small alumina columns. A standard automated method for pH adjustment of urine before the extraction step has been developed. The extraction was performed on an ASPEC (Automatic Sample Preparation with Extraction Columns, Gilson). The eluate was collected in a separate tube and then automatically injected into the chromatographic column. The catecholamines were separated by reversed-phase ion-pair liquid chromatography and quantified by fluorescence detection. No manual intervention was required during the extraction and separation procedure. One sample may be run every 15 min, ca. 96 samples in 24 h. Analytical recoveries for all three catecholamines are 63-87%, and the detection limits are 0.01, 0.01, and 0.03 microM for norepinephrine, epinephrine and dopamine, respectively, which is highly satisfactory for urine. Day-to-day coefficients of variation were less than 10%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号