首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
An amperometric biosensor for hypoxanthine determination has been developed. The sensor uses a Nafion-paraquat chemically modified glassy-carbon electrode. It detects the oxygen consumed by the enzymatic reaction catalyzed by xanthine oxidase which is immobilized on the electrode surface. The sensor responds linearly to hypoxanthine over the concentration range of 1 × 10−6 M −2 × 10−4 M. The biosensor can be reused for more than 100 times without significant deterioration in performance. After 32 days storage at 3–5°C, the sensor response remains at 68% of the initial level. The high sensitivity, selectivity and stability of this biosensor demonstrates its practical applicability for a simple, rapid and economical determination of hypoxanthine in fish samples.  相似文献   

2.
An amperometric enzyme electrode for the determination of hypoxanthine in fish meat is described. The hypoxanthine sensor was prepared from xanthine oxidase immobilized by covalent binding to cellulose triacetate and a carbon paste electrode containing hydroxymethylferrocene. The xanthine oxidase membrane was retained behind a dialysis membrane at a carbon paste electrode. The sensor showed a current response to hypoxanthine due to the bioelectrocatalytic oxidation of hypoxanthine, in which hydroxymethyiferrocene served as an electron-transfer mediator. The limit of detection is 6 × 10?7 M, the relative standard deviation is 2.8% (n=28) and the response is linear up to 7 × 10?4 M. The sensor responded rapidly to a low hypoxanthine concentration (7 × 10?4 M), the steady-state current response being achieved in less than 1 min, and was stable for more than 30 days at 5 ° C. Results for tuna samples showed good agreement with the value determined by the conventional method.  相似文献   

3.
We have utilized a microbe, which can degrade caffeine to develop an Amperometric biosensor for determination of caffeine in solutions. Whole cells of Pseudomonas alcaligenes MTCC 5264 having the capability to degrade caffeine were immobilized on a cellophane membrane with a molecular weight cut off (MWCO) of 3000-6000 by covalent crosslinking method using glutaraledhyde as the bifunctional crosslinking agent and gelatin as the protein based stabilizing agent (PBSA). The biosensor system was able to detect caffeine in solution over a concentration range of 0.1 to 1 mg mL−1. With read-times as short as 3 min, this caffeine biosensor acts as a rapid analysis system for caffeine in solutions. Interestingly, successful isolation and immobilization of caffeine degrading bacteria for the analysis of caffeine described here was enabled by a novel selection strategy that incorporated isolation of caffeine degrading bacteria capable of utilizing caffeine as the sole source of carbon and nitrogen from soils and induction of caffeine degrading capacity in bacteria for the development of the biosensor. This biosensor is highly specific for caffeine and response to interfering compounds such as theophylline, theobromine, paraxanthine, other methyl xanthines and sugars was found to be negligible.Although a few biosensing methods for caffeine are reported, they have limitations in application for commercial samples. The development and application of new caffeine detection methods remains an active area of investigation, particularly in food and clinical chemistry. The optimum pH and temperature of measurement were 6.8 and 30 ± 2 °C, respectively. Interference in analysis of caffeine due to different substrates was observed but was not considerable. Caffeine content of commercial samples of instant tea and coffee was analyzed by the biosensor and the results compared well with HPLC analysis.  相似文献   

4.
A novel enzyme reactor was prepared using calcium alginate fiber (CAF) and amine-modified nanosized mesoporous silica (AMNMS) as a support. Combination of the adsorption of the enzyme on AMNMS with the cage effect of the polymer greatly increases the catalytic activity and the stability of the immobilized enzyme. It was shown that the lifetime, stability, and catalytic activity of the enzyme reactor were greatly improved by incorporating AMNMS into CAF to efficiently encapsulate the enzyme. Glucose oxidase was chosen as a model enzyme to explore the possibility of using CAF–AMNMS as a matrix for enzyme immobilization in the design of a chemiluminescence (CL) flow-through biosensor. The sensitivity of the flow-through biosensor combined with a novel luminol-diperiodatonickelate CL system was higher than for other reported CL biosensors. The proposed biosensor exhibits short response time, easy operation, long lifetime, high catalytic activity, high sensitivity, and simple assembly.  相似文献   

5.
Journal of Solid State Electrochemistry - A highly selective and stable amperometric biosensor for the determination of the hypoxanthine (Hx) molecule was designed in this study. For this purpose,...  相似文献   

6.
An amperometric diamine sensor is developed for clinical applications in diagnosis of bacterial vaginosis (BV). The sensor is based on crosslinked putrescine oxidase (PUO) which catalyzes the conversion of diamines (mainly putrescine and cadaverine) to products including hydrogen peroxide. The hydrogen peroxide is detected anodically at platinum electrode polarized at 0.5 V versus Ag/AgCl. Platinum-plated gold electrodes used as a substrate for the sensor construction, are batch-fabricated on a flexible polyimide foil (Kapton(R), DuPont). A three-electrode cell configuration is used in all amperometric measurements. The sensor construction is based on three layers: an inner layer to reject the interference effect of oxidizable molecules, an outer diffusion controlling layer, and in addition, an enzyme middle layer. The enzyme layer was immobilized by crosslinking PUO with bovine serum albumin (BSA) using glutaraldehyde (GA). An optimization study of the enzyme solution composition was carried out. With the optimized enzyme layer, the biosensor showed a very high sensitivity and fast response time of ca. 20 s. The sensor has a linear dynamic range from (0.5-300 muM) for putrescine that covers the expected biological levels of the analyte. Details on sensor fabrication and characterization are given in the present work.  相似文献   

7.
Sung-Rok Hong  Suhee Hong 《Talanta》2010,82(3):899-266
Viral haemorrhagic septicaemia (VHS) is one of the most serious viral diseases damaging both fresh and marine fish species. VHS caused by VHSV and diagnosis of VHSV has been dependent on the conventional methods, such as cell culture and RT-PCR, which takes a few days or several hours. This study demonstrates a rapid and sensitive QCM biosensor for diagnosis of VHSV infection in fish. The QCM biosensor was developed to detect a main viral RNA encoding G protein in VHSV using the specific DNA probe. To maximize the sensitivity of the biosensor, we prepared three different DNA probes which modified 3′ end of DNA by thiol, amine, or biotin and compared three different immobilisation methods on quartz surface coated with gold: immobilisation of thiol labelled probe DNA on naked gold surface, immobilisation of amino labelled probe DNA on gold surface prepared as carboxyl chip using MPA followed by EDC/NHS activation, and immobilisation of biotin labelled probe DNA on gold surface after immobilising avidin on carboxyl chip prior to biotin. As a result, immobilisation method using avidin-biotin interaction was most efficient to immobilise probe DNA and to detect target DNA. The QCM biosensor system using biotinylated probe DNA was stable enough to withstand 32 times of repeated regenerations and the detection limit was 0.0016 μM. Diagnosis using the QCM biosensor system was more sensitive and much faster than a conventional RT-PCR analysis in detecting the viral RNA.  相似文献   

8.
A superoxide dismutase (SOD) biosensor for determination of superoxide radicals has been developed by immobilization of superoxide dismutase within gelatin (G) on a Pt electrode surface. The properties of the biosensor have been investigated and optimum conditions–enzyme concentration, glutaraldehyde concentration, and pH–were determined. The response of the G-SOD biosensor was proportional to concentration and the detection limit was 0.01 mmol L−1 at a signal-to-noise ratio of 3. The biosensor retained 89% and 60% of its sensitivity after use for three and four weeks, respectively. Immobilization of SOD on gelatin provides a biocompatible microenvironment around the enzyme and stabilizes the activity of the enzyme very efficiently. The superoxide dismutase biosensor was used to determine the antioxidant properties of acetylsalicylic acid-based drugs and the anti-radical activity of healthy and cancerous human brain tissues.  相似文献   

9.
Journal of Solid State Electrochemistry - The exploitation of metal–organic frameworks as photoactive materials for photoelectrochemical (PEC) sensing is of great importance because of their...  相似文献   

10.
The development of a microfluidic biosensor module with fluorescence detection for the identification of pathogenic organisms and viruses is presented in this article. The microfluidic biosensor consists of a network of microchannels fabricated in polydimethylsiloxane (PDMS) substrate. The microchannels are sealed with a glass substrate and packed in a Plexiglas housing to provide connection to the macro-world and ensure leakage-free flow operation. Reversible sealing permits easy disassembly for cleaning and replacing the microfluidic channels. The fluidic flow is generated by an applied positive pressure gradient, and the module can be operated under continuous solution flow of up to 80 microL min(-1). The biosensor recognition principle is based on DNA/RNA hybridization and liposome signal amplification. Superparamagnetic beads are incorporated into the system as a mobile solid support and are an essential part of the analysis scheme. In this study, the design, fabrication and the optimization of concentrations and amounts of the different biosensor components are carried out. The total time required for an assay is only 15 min including sample incubation time. The biosensor module is designed so that it can be easily integrated with a micro total analysis system, which will combine sample preparation and detection steps onto a single chip.  相似文献   

11.
An enzymeless sensor based on a multi-walled carbon nanotubes-dicetyl phosphate (MWCNT-DCP) film modified vitreous carbon electrode was developed for the determination of hypoxanthine. The MWCNT-DCP film modified electrode showed a remarkable enhancement effect on the oxidation peak current of hypoxanthine. Under the optimized conditions, the oxidation peak current is proportional to the concentration of hypoxanthine over the range from 5.0 x 10(-7) to 2.0 x 10(-4) mol L(-1) with a detection limit (S/N = 3) of 2.0 x 10(-7) mol L(-1). The MWCNT-DCP film modified electrode has been successfully used to detect hypoxanthine in fish samples.  相似文献   

12.
NMR-based biosensors that utilize laser-polarized xenon offer potential advantages beyond current sensing technologies. These advantages include the capacity to simultaneously detect multiple analytes, the applicability to in vivo spectroscopy and imaging, and the possibility of "remote" amplified detection. Here, we present a detailed NMR characterization of the binding of a biotin-derivatized caged-xenon sensor to avidin. Binding of "functionalized" xenon to avidin leads to a change in the chemical shift of the encapsulated xenon in addition to a broadening of the resonance, both of which serve as NMR markers of ligand-target interaction. A control experiment in which the biotin-binding site of avidin was blocked with native biotin showed no such spectral changes, confirming that only specific binding, rather than nonspecific contact, between avidin and functionalized xenon leads to the effects on the xenon NMR spectrum. The exchange rate of xenon (between solution and cage) and the xenon spin-lattice relaxation rate were not changed significantly upon binding. We describe two methods for enhancing the signal from functionalized xenon by exploiting the laser-polarized xenon magnetization reservoir. We also show that the xenon chemical shifts are distinct for xenon encapsulated in different diastereomeric cage molecules. This demonstrates the potential for tuning the encapsulated xenon chemical shift, which is a key requirement for being able to multiplex the biosensor.  相似文献   

13.
Shi G  Liu M  Zhu M  Zhou T  Chen J  Jin L  Jin JY 《The Analyst》2002,127(3):396-400
A novel hypoxanthine (Hx) microsensor was constructed. In this work, Nafion xanthine oxidase (XOD) and Au colloid were immobilized onto the surface of a Pt microelectrode. The enzyme biosensor displayed a quick and sensitive response to Hx. Under physiological conditions, a low detection limit, with high selectivity and sensitivity for Hx determination were obtained. The oxidation current [investigated using current-time (I-t) plots] was linear with Hx concentration ranging from 2.0 x 10(-7) to 2.0 x 10(-5) mol L(-1) with a calculated detection limit of 1.0 x 10(-7) mol L(-1) (S/N of 3). The biosensor should be promising for in vivo measurement of Hx without interferences and fouling. The change of Hx concentration in cardiac myocytes stimulated by L-arginine (L-Arg) and acetylcholine (Ach) was also studied.  相似文献   

14.
A novel micromachined interface for airborne sample-to-liquid adsorption and droplet-to-liquid transfer was designed and fabricated. It enables a robust sheet liquid flow serving as an adsorption site. The interface was characterised for flow and pressure properties and tested successfully for the transfer/adsorption of different samples. A qualitative theoretical model of the device characteristics is presented. We also used the interface to introduce a novel method and system for fast detection of dust- and vapour-based narcotics and explosives traces. The microfluidic vapour-to-liquid adsorption interface was coupled to a set of downstream QCM sensors. The system was tested successfully, with 50 ng cocaine samples rendering 15 Hz frequency shifts and with 100 ng heroine samples rendering 50 Hz frequency shifts. Gravitation invariance of the open liquid interface was demonstrated successfully, with the interface mounted upside down as well as vertically. The detection time was reduced to half of the time needed in previous systems. Machine size, weight and cost were reduced.  相似文献   

15.
Akyilmaz E  Dinçkaya E 《Talanta》2003,61(2):113-118
An amperometric biosensor based on catalase enzyme for alcohol determination was developed. To construct the biosensor catalase was immobilized by using gelatin and glutaraldehyde on a Clark type dissolved oxygen (DO) probe covered with a teflon membrane which is sensitive for oxygen. The working principle of the biosensor depends on two reactions, which one is related to another, catalyzed by catalase enzyme. In the first reaction catalase catalyzes the degradation of hydrogen peroxide and oxygen is produced and also a steady-state DO concentration occurs in a few minutes. When ethanol added to the medium catalase catalyzes the degradation of both hydrogen peroxide and ethanol and this results in a new steady-state DO concentration. Difference for first and the last steady-state DO concentration occurred in the interval surface of DO probe membrane, which related to ethanol concentration, are detected by the biosensor. The biosensor response depends linearly on ethanol concentration between 0.05 and 1.0 mM with a detection limit of 0.05 mM and a response time of 3 min. In the optimization studies of the biosensor phosphate buffer (pH 7.0; 50 mM) and 35 °C were established as providing the optimum working conditions. In the characterization studies of the biosensor some parameters such as reproducibility, substrate specificity, operational and storage stability were carried out. Finally, by using the biosensor developed and enzimatic-spectrophotometric method alcohol concentration of some alcoholic drinks were determined and results were compared.  相似文献   

16.
A high sensitive portable biosensor system capable of determining the presence of neurotoxic agents in water has been developed. The system consists of (i) a screen-printed electrode with acetylcholinesterase (AChE) immobilized on it, (ii) a self-developed portable potentiostat with an analog to digital (A/D) converter and a serial interface for transferring data to a portable PC and (iii) an own designed software, developed with Lab-Windows CVI, used to record and process the measurements. The system has been developed to perform high precision amperometrical measurements with low drifts, low noise and a good reproducibility. In the configuration depicted, the percentage of AChE inhibition is proportional to the content of neurotoxic agents in a sample. This type of measurement is performed by the steady-state method from the first steady current (by a phosphate buffer solution) and the second steady current (by an enzymatic reaction produced by the addition of acetylthiocholine chloride to the solution). Validation was performed by analyzing spiked water samples containing pesticides. The design is specially suited for screening purposes, does not need sample preconcentration, is totally autonomous and suitable for the field detection of neurotoxic agents in water.  相似文献   

17.
We have developed a mediator-type biosensor to rapidly monitor blood glucose concentrations in fish, which are an indicator of stress. Glucose oxidase was used to detect glucose concentrations and ferrocene was used to limit the effect of oxygen. We also improved the sensitivity and durability of the sensor for better performance. Single-walled carbon nanotubes were used to enhance sensor sensitivity. Affixing the carbon nanotubes (30 mg ml-1) to the working electrode increased the sensor sensitivity to 61.9 mM nA-1 mm-2, twice the value for the sensor without single-walled carbon nanotubes. A fabricated mediator-type biosensor sensor was used to perform real-time in vivo measurements. The sensor was implanted into the interstitial fluid of a fish eyeball, and detection was transmitted to a personal computer by a wireless potentiostat. Continuous measurement of the glucose concentration was possible for 78 hours. Stress was artificially applied to the fish during the measurement, and the change of blood glucose concentrations were observed. Our proposed sensor is applicable for effectively monitoring stress in free-swimming fish.  相似文献   

18.
A nanomechanical transducer is developed to detect and screen endocrine disrupting chemicals (EDCs) combining fluidic sample injection and delivery with bioreceptor protein functionalized microcantilevers (MCs). The adverse affects of EDCs on the endocrine system of humans, livestock, and wildlife provides strong motivation for advances in analytical detection and monitoring techniques. The combination of protein receptors, which include estrogen receptor alpha (ER-alpha) and estrogen receptor beta (ER-beta), as well as monoclonal antibodies (Ab), with MC systems employing modified nanostructured surfaces provides for excellent nanomechanical response sensitivity and the inherent selectivity of biospecific receptor-EDC interactions. The observed ranking of binding interaction of the tested EDCs with ER-beta is diethylstilbestrol (DES) > 17-beta-estradiol > 17-alpha-estradiol > 2-OH-estrone > bisphenol A > p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) with measurements exhibiting intra-day RSDs of about 3%. A comparison of responses of three EDCs, which include 17-beta-estradiol, 17-alpha-estradiol, and 2-OH-estrone, with ER-beta and ER-alpha illustrates which estrogen receptor subtype provides the greatest sensitivity. Antibodies specific to a particular EDC can also be used for analyte specific screening. Calibration plots for a MC functionalized with anti-17-beta-estradiol Ab show responses in the range of 1 x 10(-11) through 1 x 10(-7) M for 17-beta-estradiol with a linear portion extending over two orders of magnitude in concentration.  相似文献   

19.
A new and simple-to-prepare hypoxanthine biosensor has been developed using xanthine oxidase (XOD) immobilised on carbon electrode surfaces. XOD was immobilised by glutaraldehyde cross-linking on carbon film (CF) electrodes and on carbon nanotube (CNT) modified CF (CNT/CF). A comparison of the performance of the two configurations was carried out by the current response using amperometry at fixed potential; the best characteristics being exhibited by XOD/CNT/CF modified electrodes. The effects of electrolyte pH and applied potential were evaluated, and a proposal is made for the enzyme mechanism of action involving competition between regeneration of flavin adenine dinucleotide and reduction of hydrogen peroxide. Under optimised conditions, the determination of hypoxanthine was carried out at ?0.2 V vs. a saturated calomel electrode (SCE) with a detection limit of 0.75 μM on electrodes with CNT and at ?0.3 V vs. SCE with a detection limit of 0.77 μM on electrodes without CNT. The applicability of the biosensor was verified by performing an interference study, reproducibility and stability were investigated, and hypoxanthine was successfully determined in sardine and shrimp samples.  相似文献   

20.
The aim of this study was to develop an optical biosensor inhibition immunoassay, based on the surface plasmon resonance (SPR) principle, for use as a screening test for 13 (fluoro)quinolones, including flumequine, used as veterinary drugs in food-producing animals. For this, we immobilised various quinolone derivatives on the sensor chip and tested binding of a range of different antibodies (polyclonal and one engineered antibody) in the presence and absence of free (fluoro)quinolones. The main challenge was to detect flumequine in an assay giving good results for the other compounds. One antigen–antibody combination proved satisfactory: polyclonal antibodies raised against a dual immunogen and, on the sensor chip, a fluoroquinolone derivative. It was the first time that this concept of the bi-active antibody was described in the literature.The assay, optimised for detection in three matrices (poultry muscle, fish, and egg), was tested on incurred samples prepared by liquid extraction followed by two washing steps. This rapid, simple method proved adequate for detecting at least 13 (fluoro)quinolones at concentrations below established maximum residue levels (MRLs). The reference molecule norfloxacin could be detected in the range of 0.1–10 μg kg−1 in extracts of egg and poultry meat and in the range of 0.1–100 μg kg−1 in extracts of fish. The determined midpoints of these calibration curves were about 1, 1.5 and 3 μg kg−1 in poultry meat, egg and fish, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号