首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Antimony(III) is determined by means of electrolysis at ?0.40 V vs. Ag/AgCl on a gold-coated gold fibre electrode for 0.5–10 min in a redox buffer containing 0.01 M iron(II) in 0.10 M hydrochloric acid, and subsequent stripping with a constant current of 0.50μA either in 2 M hydrochloric acid or in 4 M hydrochloric acid/4 M calcium chloride. Antimony(V) is determined by the same procedure in 4 M hydrochloric acid medium. Bismuth(III) is masked by the addition of iodide to the sample prior to electrolysis. Antimony(III) and antimony(V) are determined by standard addition methods; the whole procedure including digital and graphical evaluation of the results is fully automated. The antimony(V) concentrations in the river water reference sample SLRS-1 and the seawater reference sample NASS-1 were found to be 0.63 and 0.31 μg l?1 with standard deviations of 0.046 and 0.051 μg l?1, respectively (n=15). The certified value for SLRS- 1 is 0.63±0.05 μg l?1; no certified value is available for NASS-1.  相似文献   

2.
Arsenic(V) is reduced to elemental arsenic on a gold-coated platinum-fibre electrode at electrolysis potentials below ?1.60 V vs. Ag/AgCl and subsequently re-oxidized, either by means of a constant current, or chemically, with gold(III) as oxidant. Total arsenic in acidified seawater can be determined by means of electrolysis for 60 s at ?1.80 V vs. Ag/AgCl and subsequent stripping in 4 M hydrochloric acid containing 2.5 M calcium chloride. The detection limit obtained after 60 s of electrolysis (ca. 0.1 μg1?1) is about ten times lower than that obtained by the electrochemical stripping methods for arsenic(III) reported hitherto. Total arsenic in urine is determined after digestion with nitric acid and hydrogen peroxide.  相似文献   

3.
《Analytical letters》2012,45(2):283-302
Abstract

A method is described for the reliable determination of copper, lead, cadmium and zinc in natural waters by anodic stripping potentiometry with the use of a novel combined electrode. The method involves two stripping cycles during which copper is initially determined on its own, followed by simultaneous determination of lead, cadmium and zinc after addition of gallium (III) ions. The optimum conditions include 0.01 M HCl as supporting electrolyte, 10 mg/L Hg (II) as chemical oxidant; Edep(Cu) -700 mV vs Ag/AgCl; Edep(Pb,Cd,Zn) -1200 mV vs Ag/AgCl; tdep 10s; 150 μg/L Ga (III); sample rotation rate 5 and rest period 30s. Under these conditions, as low as 0.06 μg/L Cu (0.7% RSD); 0.2 μg/L Pb (13% RSD); 0.04 μg/L Cd (7.8% RSD) and 0.06 μg/L Zn (5.5% RSD) can be determined reliably. A linear concentration range of 0–110 μg/L was obtained for the four metals. The successful application of the method to reference fresh water, creek water and tap water is demonstrated.  相似文献   

4.
The behaviour of 2-mercaptoethanol at a hanging mercury drop electrode by cathodic stripping voltammetry (c.s.v.) is studied. The stripping curves are recorded by three scanning modes: rapid-scan direct-current, differential-pulse and fundamental harmonic alternating-current polarography. Under the recommended conditions, pre-electrolysis is done at a potential of 0.0 V vs. Ag/AgCl for 3 min in a medium of pH 6.7 or 8 (Britton-Robinson buffer). Then after 1 min, stripping is done at a scan rate of 6.6 mV s?1 preferably in the differential-pulse mode. The stripping peak at about ?0.4 V is used to determine 2-mercaptoethanol within the concentration range 3 × 10?8/2-8 × 10?7 mol l?1. Calibration functions are reported; the standard additions method is preferred near the limit of detection. The interferences of several organic compounds are described.  相似文献   

5.
The fluoroquinolone antibacterial agent ofloxacin was studied by adsorptive stripping voltammetry. Controlled interfecial accumulation of ofloxacin on a static mercury drop electrode in the hanging mercury drop mode provides high sensitivity. The linear concentration range was 0.079–197.5 μg ml?1 when using a 60-s preconcentration at ?1 V vs. Ag/AgCl in Britton-Robinson buffer of pH 6.00. The detection limit of ofloxacin was 1 ng ml?1. The precision is excellent with a relative standard deviation of ca. 0.75% at a concentration of 0.848 μg ml?1.  相似文献   

6.
《Electroanalysis》2004,16(18):1508-1513
A stripping voltammetric method for the determination of ethylenethiourea in water samples is described based on its adsorptive deposition at the hanging mercury drop electrode (HMDE). In a borate buffer (pH 9.0) as supporting electrolyte, ETU is deposited at +100 mV (vs. Ag/AgCl) and stripped during the cathodic scan. The linear range for the measurements was from 2.0 to 100 μg L?1, with a detection limit calculated as 1.4 μg L?1 after a deposition time of 300 s and a RSD of 1.9% (n=5) for 50 μg L?1 of ETU measured. The interferences of some organic compounds and metallic ions were tested. Recoveries between 93 and 110% were obtained using the standard addition method for spiked samples of natural and drinking waters. The method is rapid and applicable in the monitoring of ETU residues in water samples.  相似文献   

7.
Total arsenic in sea water is determined in a fully automated flow system, by means of potentiostatic deposition for 4 min at a 25-μm gold fibre electrode and subsequent constant-current stripping in 5 M hydrochloric acid. Previously the sample is acidified with hydrochloric and arsenic(V) is reduced to arsenic(III) with iodide. During stripping, the potential vs. time transient is recorded with a real-time measurement rate of 26.5 kHz and a potential resolution of 1 mV. Cleaning and regeneration of the gold electrode are fully automated. The total arsenic concentrations in two reference sea waters (NASS-1 and CASS-1) were evaluated by single-point standard addition and found to be 1.58 and 1.14 μg l?1 with standard deviations of 0.39 and 0.28 μg l?1, respectively; certified values are 1.65 ± 0.19 and 1.04 ± 0.07 μg l?1. The arsenic(III) content in these samples was below the detection limit (0.15 μg l?1).  相似文献   

8.
Sensitive cathodic stripping voltammetric methods have been developed for two quinolone antibacterial drugs, pipemidic acid (PIP) and ofloxacin (OFL) using hanging mercury drop electrode as working electrode vs. Ag/AgCl reference electrode. The methods were developed for the determination of drugs individually as well as simultaneously. 0.1 M and 0.01 M hydrochloric acid was used as medium for PIP and OFL, respectively, 0.1 M potassium chloride was used as base electrolyte. Reduction waves were observed for PIP within ?700 mV to ?800 mV and for OFL within ?1100 mV to ?1200 mV. Linear calibration ranges for PIP and OFL were observed within 10–100 μg ml?1 with detection limits of 50 ng ml?1 and 1 μg ml?1, respectively. Relative standard deviations (RSD) for the analysis of 10 gµg ml?1 of PIP and OFL (n = 6) were 0.5% and 1.4%, respectively. The presence of glucose, lactose, sorbitol, gum arabic, starch, magnesium stearate, methylparaben and propylparaben did not affect the determinations of both PIP and OFL. The methods were used for the analysis of pharmaceutical preparations and the results indicated relative deviation of 0.5–5.5% from labeled values with RSD within 0.49–2.5%. PIP and OFL could also be determined simultaneously, and were determined from spiked human urine.  相似文献   

9.
Molybdenum is determined by adsorptive cathodic stripping voltammetry in 0.15 M nitric acid solution containing 15 μM 2′,3,4′,5,7-pentahydroxyflavone (morin) as a ligand. In this medium, molybdenum is preconcentrated on a hanging mercury drop electrode and stripped cathodically in square-wave voltammetry mode, with a peak potential of -350 mV vs. Ag/AgCl (saturated KCl). The effect of various parameters (ligand concentration, supporting electrolyte composition, accumulation potential and collection time) on the sensitivity and linear range of the calibration curve are discussed. With controlled accumulation for 1 min, the detection limit (3σ) was 0.45 ng ml?1 molybdenum and the calibration curve is linear up to 70 ng ml?1. The procedure is applied to the determination of molybdenum in real samples with satisfactory results.  相似文献   

10.
Folic acid can be determined at nanomolar concentrations by controlled adsorptive accumulation of folic acid on a static mercury drop electrode held at ?0.3 V vs. Ag/AgCl followed by reduction of the surface species. In 0.1 M sulfuric acid, a cathodic scan gives peaks at ?0.47 v and ?0.75 V vs. Ag/Agcl; the latter peak provides greater sensitivity. Differential-pulse stripping is shown to be superior to normal-pulse and d.c. stripping. After a 5-min preconcentration, the detection limit is about 1 × 10?10 M folic acid. The adsorptive stripping response is evaluated with respect to concentration dependence, preconcentration time and potential, solution acidity and the presence of gelatin and bromide. The relative standard deviation at the 5 × 10?8 M level is 1.2%. This method is applied to the determination of folic acid in pharmaceutical tablets.  相似文献   

11.
Trichlorobiphenyl is determined in the concentration range 0.004–1 mg l?1 by adsorptive stripping voltammetry at a hanging mercury drop electrode. Preconcentration is achieved by adsorption at a potential of ?0.40 (V (vs. Ag/AgCl), and desorption at ?1.10 V. Biphenyl interferes with the determination only when present in 5-fold molar amounts compared to trichlorophenyl. The interference of DDT is eliminated by prior treatment of the sample solution with sulphuric acid. The method was applied for the analysis of waste and natural waters, the relative standard deviation being <5%.  相似文献   

12.
A hemoglobin‐titanate composite based biosensor was chosen for determination of H2O2 in an acidic medium. CV results of the Hb‐titanate modified pyrolytic graphite electrode showed a pair of well‐defined, quasi‐reversible redox peaks centered at ?246 mV (vs. Ag/AgCl) in a pH 5.0 HAc‐NaAc buffer solution. The modified electrode exhibited good electrocatalytic response for monitoring H2O2 and had a large linear detection range from 20 μM to 3.2 mM with a detection limit of 8 μM (S/N=3) and a sensitivity of 29.7 mA M?1 cm?2 in the pH 5.0 solution. The biosensor also possessed good long term storage stability.  相似文献   

13.
A method is described for the sequential determination of Sb(III) and Sb(V) using Osteryoung square wave cathodic stripping voltammetry. It employs an in-situ plated bismuth-film on an edge-plane graphite substrate as the working electrode. Selective electro-deposition of Sb(III)/Sb(V) is accomplished by applying a potential of ?500 mV vs. Ag/AgCl, followed by reduction to stibine at a more negative potential in the stripping step. Stripping was carried out by applying a square wave waveform between ?500 and ?1400 mV to the antimony deposited. The stripping peak current at ?1150 mV is directly proportional to the concentration of Sb( III)/Sb(V). The calibration plots for Sb (III) were linear up to 12.0?µg L?1 depending on the time of deposition. The calibration plots for Sb (V) were linear up to 7.0?µg L?1, also depending on the time of deposition. The relative standard deviation in the determination of 0.1?µg L?1 of Sb(III) is 4.0% (n?=?5), and the limit of detection is as low as 2 ng L?1. In case of 0.1?µg L?1 Sb(V), the relative standard deviation is 3.0% (n?=?5) and the detection limit also is 2 ng L?1. The method was applied to the analysis of river and sea water samples.  相似文献   

14.
《Electroanalysis》2004,16(11):949-954
The preparation and the electrochemical study of Disperse Blue 1‐chemically modified electrodes (DB1‐CME), as well as their efficiency for the electrocatalytic oxidation of NADH is described. The proposed mediator was immobilized by physical adsorption onto graphite electrodes. The electrochemical behavior of DB1‐CME was studied with cyclic voltammetry. The electrochemical redox reaction of DB1 was found to be reversible, revealing two well‐shaped pair of peaks with formal potentials 152 and ?42 mV, respectively, (vs. Ag/AgCl/3M KCl) at pH 6.5. The current Ip has a linear relationship with the scan rate up to 800 mV s?1, which is indicative for a fast electron transfer kinetics. The dissociation constants of the immobilized DB1 redox couple were calculated pK1=4 and pK2=5. The electrochemical rate constants of the immobilized DB1 were calculated k1°=18 s?1 and k2°=23 s?1 (Γ=2.36 nmol cm?2). The modified electrodes were mounted in a flow injection manifold, poised at +150 mV (vs. Ag/AgCl/3M KCl) and a catalytic current due to the oxidation of NADH was measured. The reproducibility was 1.4% RSD (n=11 for 30 μM NADH) The behavior of the sensor towards different reducing compounds was investigated. The sensor exhibited good operational and storage stability.  相似文献   

15.
A square wave cathodic stripping voltammetric (SWCSV) method has been developed for the determination of insecticide diafenthiuron. The procedure is based on controlled accumulation of the insecticide on a static hanging mercury drop electrode (SHMDE) at 0.00?mV (vs. Ag/AgCl) in Britton-Robinson buffer solution (pH 7.0). The insoluble mercury compound was reduced at ?510?mV during the cathodic potential scan. The peak currents were linearly related to insecticide concentration between 30.4 and 3200?µg?L?1 . The detection and quantification limit were 9.1?µg?L?1 and 30.4?µg?L?1, respectively. The proposed analytical procedure was applied to natural water and soil samples. The method was extended to direct determination of diafenthiuron in insecticide formulation Polo® 50 WP and average content of 50.3?±?1.7 (m/m) at 90% confidence level, in close agreement with the 50.0% quoted by the manufacturer. HPLC comparison method indicated that accuracy was in agreement with that obtained by the proposed method.  相似文献   

16.
The adsorptive stripping voltammetry of telmisartan was investigated with a hanging mercury drop electrode. This compound produced a catalytic hydrogen wave at ?1.5 V in Britton Robinson buffer of pH 10.38, and the peak current increased with adsorptive accumulation at the electrode. Adsorptive stripping voltammetry with the catalytic hydrogen wave could provide a sensitive novel method for the determination of telmisartan. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for telmisartan determination. Under these optimized conditions the square-wave adsorptive stripping voltammetric (SW-AdSV) peak current showed a linear dependence on drug concentration over the range 0.05–3.00 μg/mL (1 × 10?7?6 × 10?6 M) (r = 0.999) with accumulation for 120 s at ?1.0 V vs. Ag/AgCl. The proposed electrochemical procedure was successfully applied for the determination of telmisartan in pharmaceutical tablets and human plasma. The results of the developed SW-AdSV method were comparable with those obtained by reported analytical procedures.  相似文献   

17.
《Electroanalysis》2006,18(9):918-927
Uric acid (UA) sensor based on molecularly imprinted polymer‐modified hanging mercury drop electrode was developed for sensitive and selective analysis in aqueous and blood serum samples. The uric acid‐imprinted polymer was prepared from melamine and chloranil and coated directly onto the surface of a hanging mercury drop electrode, under charge‐transfer interactions at +0.4 V (vs. Ag/AgCl), in model 303A electrode system connected with a polarographic analyzer/stripping voltammeter (PAR model 264A). The binding event of uric acid was detected in the imprinted polymer layer through differential pulse, cathodic stripping voltammetry (DPCSV) at optimized operational conditions [accumulation potential +0.4 V (vs. Ag/AgCl), accumulation time 120 s, pH 7.0, scan rate 10 mV s?1, pulse amplitude 25 mV]. The limit of detection for UA was found to be 0.024 μg mL?1 (RSD=0.64%, S/N=3). Under the optimized operational conditions, the sensor was able to differentiate between uric acid and other closely structural‐related compounds and interfering substances. Ascorbic acid (AA), a major interferent in UA estimation, was not adsorbed on the surface of sensor electrode. The present sensor is, therefore, UA‐selective at all concentrations of AA present in human blood serum samples. The précised and accurate quantification of UA have been made in the dilute as well as concentrated regions varying within limits 0.1–4.0 and 9.8–137.0 μg mL?1, respectively.  相似文献   

18.
A sensitive and reliable method is described for the determination of total Sb(III,?V) at traces levels by Osteryoung square-wave anodic stripping voltammery (OSWASV). This method is based on the co-deposition of Sb(III,?V) with Bi(III) onto an edge-plane pyrolytic graphite substrate at an accumulation step. OSWASV studies indicated that the co-deposited antimony was oxidised with anodic scans to give an enhanced anodic peak at about 450?mV vs. Ag/AgCl (sat. KCl). The anodic stripping peak current was directly proportional to the total concentration of antimony in the ranges of 0.01–0.10?µg?L?1, 0.10–1.0?µg?L?1 and 1.0–18.0?µg?L?1 with correlation coefficient higher than 0.995 when 2.0?mol?L?1 hydrochloric acid was used. The detection limits calculated as S/N?=?3 was 5.0?ng?L?1 in 2.0?mol?L?1 hydrochloric acid at 180?s deposition time. The relative standard deviation was 5% (n?=?6) at 0.10?µg?L?1 level of antimony. The analytical results demonstrate that the proposed method is applicable to analyses of real water samples.  相似文献   

19.
A very sensitive electrochemical stripping procedure for aluminum is reported. Accumulation is achieved by controlled adsorption of the aluminum/solochrome violet RS complex on the static mercury drop electrode. Optimal experimental parameters include an accumulation potential of ?0.45 V, solochrome violet RS concentration of 1 × 10?6 M, and a linear-scan stripping mode. The detection limit is 0.15 μg l?1, the response is linear over the 0–30 μg l?1 concentration range, and the relative standard deviation (at the 10 μg l?1 level) is 2%. Most cations do not interfere in the determination of aluminum. The interference of iron(III) is eliminated by addition of ascorbic acid. Results are reported for snow samples.  相似文献   

20.
《Electroanalysis》2006,18(11):1081-1089
This paper describes the voltammetric behavior of As(III) at the hanging mercury drop electrode (HMDE) in the presence of sodium diethyl dithiocarbamate (SDDC) and a new voltammetric method for the determination of As(III) at trace levels. The method is based on the adsorptive deposition of a As(III) complex with SDDC at ?0.45 V (vs. Ag/AgCl) on the HMDE in acidic medium of 0.01 mol L?1 HCl (pH 2.0) and its cathodic stripping during the potential scan (100 mV s?1). The linear range for the determination of As(III) in the presence of SDDC (4 μmol L?1) in water samples was between 1 and 10 μg L?1 for a deposition time of 300 s (r=0.994) and between 10 and 100 μg L?1 for a deposition time of 60 s (r=0.999). For the determination of As(III) in dialysis concentrate samples, the linear range was between 5 and 25 μg L?1 for a deposition time of 180 s (r=0.992) and between 10 and 100 μg L?1 for a deposition time of 60 s (r=0.996). Detection limits of 0.3 and 2.2 μg L?1 in water and dialysis concentrate samples were calculated for the method using a deposition time of 300 and 180 s, respectively. Recovery values between 93.0 and 110.0% for As(III) added to deionized, mineral, seawater (synthetic and real) and dialysis concentrate samples prove the satisfactory accuracy and applicability of the procedure.  相似文献   