首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 34 毫秒
1.
A PVC (poly vinyl chloride) membrane electrode for lead ion based on 2-(((E)-2-((E)-1-(2-hydroxyphenyl)methyliden)hydrazono)metyl)phenol (HMHMP) as a membrane carrier was prepared. This electrode exhibited linear response with Nernstian slope of 29.2?±?0.2?mV per decade within the concentration range of 2.0?×?10?7–1.0?×?10?1?M lead ion. The limit of detection, as determined from the intersection of the extrapolated linear segments of the calibration plot, was 8.0?×?10?8 M. The electrode exhibited high selectivity for Pb (II). The response time of the electrode was about 5–10?s for different concentrations. The electrode is suitable for use in aqueous solutions in a pH range of 5.0–7.5. It was used as an indicator electrode in a titration of Pb (II) with chromate at constant pH. This electrode was used for the determination of lead in ore samples, and the results were in agreement with those obtained with an atomic absorption spectroscopy (AAS) method. Also lead selective electrode was used for monitoring of lead in spiked samples of the Zayanderud River and waste water by the potentiometry technique.  相似文献   

2.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on Co(III)-Schiff base [Co(5-NO2- Salen)(PBu3)]ClO4•H2O (where 5-NO2-SalenH=bis(5-nitrosalycilaldehyde)ethylenediamine) as a new carrier for construction of perchlorate-selective electrode by incorporating the membrane ingredients on the surface of a graphite electrodes has been reported. The proposed electrode possesses a very wide Nernestian potential linear range to perchlorate from 1.0×10-6 to 5.0×10-1 mol•L-1 with a slope of (59.4±0.9) mV per decade of perchlorate concentration with a low detection limit of 5.0×10-7 mol•L-1 and good perchlorate selectivity over the wide variety of other anions. The developed electrode has an especially fast response (<5 s) and a wide pH independent range (3.0—12.0) in comparison with recent reported electrodes and can be used for at least 2 months without any considerable divergence in their potential response. This electrode was used for the determination of perchlorate in river water, drinking water, sludgy water and human urine with satisfactory results without complicated and time consuming pretreatment.  相似文献   

3.
A new PVC-membrane electrode for Co2+ ions based on N,N′-di(thiazol-2-yl)formimidamide (TF) as membrane carrier has been developed. The electrode resulted in Nernstian response (29.5?±?0.4?mV decade?1) for Co2+ ion over a wide concentration range (2.5?×?10?7 ?1.0?×?10?1?M) with a detection limit of 6.1?×?10?8?M. The sensor has a response time of about 10?s, and can be used for at least 2 months without observing any deviation from the Nernstain response. The electrode revealed good selectivity towards cobalt(II) ion over a wide variety of alkali, alkaline earth, transition, and heavy metal ions and could be used in the pH range 2.0–7.0. The electrode was used for determination of Co2+ in real samples.  相似文献   

4.
The electrochemical response of a modified-carbon nanotubes paste electrode with p-aminophenol was investigated as an electrochemical sensor for sulfite determination. The electrochemical behaviour of sulfite was studied at the surface of the modified electrode in aqueous media using cyclic voltammetry and square wave voltammetry. It has been found that under the optimum condition (pH 7.0) in cyclic voltammetry, the oxidation of sulfite occurs at a potential about 680?mV less positive than that of an unmodified-carbon nanotubes paste electrode. Under the optimized conditions, the electrocatalytic peak current showed linear relationship with sulfite concentration in the range of 2.0?×?10?7–2.8?×?10?4?mol?L?1 with a detection limit of 9.0?×?10?8?mol?L?1 sulfite. The relative standard deviations for ten successive assays of 1.0 and 50.0?µmol?L?1 sulfite were 2.5% and 2.1%, respectively. Finally, the modified electrode was examined as a selective, simple and precise new electrochemical sensor for the determination of sulfite in water and wastewater samples.  相似文献   

5.
A new tin complex namely tetracyclohexyl tin(IV) (TCHT) was synthesized and used as the ion carrier for the construction of a highly selective salicylate sensor. This sensor shows a Nernstian response to salicylate ions over a very wide concentration (1.0 × 10?7–1.0 × 10?1 M) in a pH range of 5.5–10.5. The optimum selectivity and response could be obtained for a membrane incorporating 30% PVC, 61% BA, 3% of cationic additive (HTAB) and 6% of TCHT. The response time of the electrode is very short in the whole concentration range (15 s). The electrode also shows an excellent discriminating ability for salicylate ions with respect to the most common organic and inorganic anions including chloride, sulfate, nitrate, nitrite, cyanide, sulfite, iodide, thiocyanate, phosphate, acetate, oxalate, citrate, and tartarate ions. The detection limit of the proposed sensor is 8.0 × 10?8 M. The electrode was successfully used for determining the concentration of salicylate ion in synthetic serums.  相似文献   

6.
A dichromate‐selective PVC‐membrane electrode based on Quinaldine Red (an acridinium derivative) is described. The electrode exhibits rapid (< 30 s) and linear response to the activity of Cr(VI) anions in the range of 5.2 × 10?6 ?1.0 × 10?1 M dichromate with the limit of detection 2.5 × 10?6 Mof Cr2O72?. The sensor is used as an indicator electrode in potentiometric determination of Cr(VI) anions and is also suitable for end‐point indication in the titrations of proper metal ions with dichromate under laboratory conditions. The proposed electrode has been applied to the direct potentiometric determination of Cr(VI) anions in water samples with satisfactory results.  相似文献   

7.
《Analytical letters》2012,45(4):595-606
A highly sensitive polyvinyl chloride (PVC) membrane electrode, based on copper(II)-bis(N-4-methylphenyl-salicyldenaminato) complex, (CuL2), as a carrier was reported for the determination of chromate ion. The influence of membrane composition, pH, and possible interfering anions on the response of the ion selective electrode was investigated. The sensor exhibited a Nernstian slope of 29.7 mV per decade when the chromate concentration was varied between 2.0 × 10?7–1.50 × 10?2 M in a wide pH range (6.0 to 9.0). The detection limit of the ion selective electrode was 9.2 × 10?8 M. The proposed sensor was used for at least 4 months without any considerable divergence in potential. It was applied as indicator electrode in potentiometric titration of chromate ion with Pb2+ and Tl+.  相似文献   

8.
This study demonstrates the application of the composite of multi-walled carbon nanotube polyvinylchloride (MWCNT-PVC) based on Bismarck Brown R for gallium sensor. MWCNT has a role to enhance the hydrophobicity of the membrane, which leads to a more stable potential signal. In addition by applying polypyrrol on the surface of this sensor a reduction in the drift of potential occurred and equilibrium potential was achieved faster. Compared to previous studies, using a stainless steel disc instead of a wire electrode causes to obtain an easily and more homogeneous coated electrode. The sensor shows a good Nernstian slope of 19.70?±?0.37?mV?decade?1 in a wide linear range concentration of 1.0?×?10?7 to 1.0?×?10?2?M of Ga(NO3)3. The detection limit of this electrode was 7.7?×?10?8?M of Ga(NO3)3. This proposed sensor is applicable in a wide pH range of 2 to 8. It has a short response time of about 8?s and has a good selectivity over twenty four various metal ions. The practical analytical utility of this electrode is demonstrated by measurement of Ga(III) in rock and different water samples.  相似文献   

9.
《Electroanalysis》2004,16(16):1330-1335
A poly(vinyl chloride) membrane sensor based on oxalic acid bis (cyclohexylidene hydrazide) as membrane carrier was prepared and investigated as a Cr(III)‐selective electrode. The electrode reveals a Nernstian behavior (slope 19.8±0.4 mV decade?1) over a wide Cr(III) ion concentration range 1.0×10?7–1.0×10?2 mol dm?3 with a very low limit of detection (i.e., down to 6.3×10?8 mol dm?3). The potentiometric response of the sensor is independent of the pH of the test solution in the pH range 1.7–6.5. The electrode possesses advantage of very fast response, relatively long lifetime and especially good selectivity to wide variety of other cations. The sensor was used as an indicator electrode, in the potentiometric titration of chromium ion and in the determination of Cr(III) in waste water and alloy samples.  相似文献   

10.
The two podand chelates based on diethylsulfide, 1,5‐bis(2′‐hydroxy‐4′‐nitrophenoxy)‐3‐thiapentane (L1) and 1,5‐bis(8′‐oxybenzopyridine)‐3‐thia pentane (L2), have been synthesized and explored as neutral ionophores for preparing poly(vinyl chloride) based membrane electrodes selective to Pb2+. The addition of anionic additives and various plasticizers has been found to substantially improve the performance of the electrode. The best performance was obtained with the electrode No. 1 having a membrane of ionophore (L1) with the composition PVC:o‐NPOE:ionophore (L1):NaTFPB (%w/w) of 33 : 62 : 3 : 2. The electrode exhibits Nernstian response with a slope of 31.57±0.3 mV decade?1 of activity in the concentration range from 2.0×10?9 to 1.0×10?1 M Pb2+, performs satisfactorily over a wide pH range (1.6–7.0), with a fast response time (5 s).  相似文献   

11.
A chloride ion‐selective electrode (ISE) membrane was developed by using a copolymeric ion‐exchanger resin (trimethyl ethenyl quaternary ammonium chloride polystyrene‐divinylbenzene copolymer resin, TMEQAC PSDVB), the ionophore ({μ‐[4,5‐Dimethyl‐3,6‐bis(dodecyloxy)‐1,2‐phenylene]}bis(mercury chloride), ETH9033), the plasticizer (bis(2‐ethylhexyl) sebacate, DOS), and the membrane substrate (polyvinylchloride, PVC). At 25 °C, the electrode exhibited an ideal Nernstian response of 59.2 mV/decade with the linear calibration concentration range from 1.0 × 10?4‐1.0 × 10?2 M (r2 = 0.9930). The limit of detection was 2.45 ppm (6.9 × 10?2 mM) and the measurement response time was less than 10 seconds. The working temperature range of electrode was 10‐45 °C. The working pH range for chloride ion measurement was 2.0‐11.0. Among the various anions examined in this work, only I?, SCN?, and MnO4? ions show significant interference to the electrode measurement. The chloride ISE can be used at least 72 days. The determination of chloride ion content in three kinds of environmental water sample with the electrode method was accurate (92‐95%) and precise (RSD < 4.4%) and did not show significance difference from the high‐performance liquid chromatography method.  相似文献   

12.
《Electroanalysis》2006,18(12):1186-1192
A PVC membrane electrode using [Bzo2Me2Ph2(16)hexaeneN4] ( I ) as ionophore, oleic acid as lipophilic additive and o‐nitrophenyloctyl ether as plasticizer has been investigated as Zn(II)‐selective electrode. The membrane incorporating 34.9% (w/w) PVC, 2.3% I , 4.7% OA and 58.1% o‐NPOE gave linear response over the concentration range 2.82×10?6?1.0×10?1 M with a Nernstian slope of 28.5±0.2 mV/decade of concentration with a detection limit of 2.24×10?6 M (0.146 ppm) and showed a response time of less than 10 s and could be used in pH range 2.5–8.5. High selectivity was obtained over a wide variety of metal ions. The proposed electrode was successfully used as an indicator electrode in potentiometric titration of zinc ions with EDTA and for determination of zinc in real samples.  相似文献   

13.
《Electroanalysis》2004,16(11):922-927
A novel chloride PVC‐based membrane sensor based on a ruthenium(III) Schiff's base complex, as an excellent neutral carrier, has been developed. The ruthenium complex, in combination with a ketonic plasticizer and a cationic additive led to ISEs with fundamental characteristics, such as slope sensitivity, short response times and selectivity coefficients, which were sufficient for practical applications. The sensor with composition of 30% PVC, 62% benzyl acetate, 5% ruthenium(III) Schiff's base complex and 3% hexadecyltrimethyl ammonium bromide displays near‐Nernstian behavior in a wide concentration range (1.0×10?1–3.0×10?6 M with slope of ?54.5±0.5) with a detection limit of 2.0×10?6 M (71.0 ng per mL). The response of the electrode is independent on pH in the range of 4.0–10.0 and can it be used for at least ten weeks. The proposed electrode shows a very short response time (<20 s) in whole concentration range. The sensor displays high selectivity toward chloride ions over several organic and inorganic anions. It was successfully applied for the determination of chloride in serum samples. It was also used as an indicator electrode in the potentiometric titration of chloride ions with silver nitrate solution.  相似文献   

14.
A new electrode was developed by one-step potentiostatic electrodeposition (at ?2.0 V for 20 s) of Au/SiO2 nanoparticles on a glassy carbon electrode. The resulting electrode (nano-Au/SiO2/GCE) was characterized by scanning electronic microscopy, X-ray photoelectron spectroscopy and electrochemical techniques. The electrochemical behavior of dihydronicotinamide adenine dinucleotide (NADH) at the nano-Au/SiO2/GCE were thoroughly investigated. Compared to the unmodified electrode, the overpotential decreased by about 300 mV, and the current response significantly increased. These changes indicated that the modified electrode showed excellent catalytic activity in the oxidation of NADH. A linear relationship was obtained in the NADH concentration range from 1.0?×?10?6 to 1.0?×?10?4 mol?L?1. In addition, amperometric sensing of ethanol at the nano-Au/SiO2/GCE in combination with alcohol dehydrogenase and nicotinamide adenine dinucleotide was successfully demonstrated. A wide linear response was also found for ethanol in the range from 5.0?×?10?5 to 1.0?×?10?3 mol?L?1 and 1.0?×?10?3 to 1.0?×?10?2 mol?L?1, respectively. The method was successfully applied to determine ethanol in beer and biological samples.  相似文献   

15.
In this work, a highly selective membrane triiodide sensor based on a new charge‐transfer complex of bis(2,4‐dimethoxybenzaldehyde)butane‐2,3‐dihydrazone with iodine (Iodide Charge Transfer complex: ICT) as membrane carrier is introduced. The influences of five different solvent mediators on sensitivity and selectivity of the proposed sensor were considered. The best performance was obtained with the membrane composition containing 30% poly (vinyl chloride), 63% DBP, 5% ICT and 2% HTAB. The electrode shows a Nernstian behavior over a very wide triiodide ion concentration range (1.0 × 10?7‐1.0 × 10?2 M), and a detection limit value of 8.0 × 10?8 M. The effect of pH on the potentiometric response of the sensor was also studied, and it was found that the response of the electrode is independent of the pH of the solution in the pH range of 4.0–10. The proposed sensor has a very fast response time (< 12 s), and good selectivities relative to a wide variety of common inorganic and organic anions, including iodide, acetate, bromide, chloride, fluoride, nitrite, nitrate, sulfite, sulfate, cyanide and thiocyanate. In fact the selectivity behavior of the proposed triiodide ion‐selective electrode shows great improvements compared to the previously reported electrodes for triiodide ion. The proposed membrane sensor can be used for at least 6 months without any divergence in the potentials. The electrode was successfully applied as an indicator electrode in the titration of triiodide with thiosulfate ion.  相似文献   

16.
《Electroanalysis》2003,15(2):139-144
A highly selective and sensitive membrane electrode based on vanadyl salen complex (VS), which responds to monohydrogenphosphate (MHP) ions is described. The response of the sensor is Nernstian over the wide concentration range (1.0×10?1 ? 5.0×10?6 M) of MHP. The sensitivity of the electrode is high enough to permit the detection of as little as 0.6 μg/mL of MHP without any significant interference from high levels of other anions. The potentiometric selectivity coefficient data revealed negligible interference from 11 common anions. The electrode has a fast response time (<25 s), good slope stability at pH 8.2 for a period of at least eight weeks. It was successfully applied for the direct determination of monohydrogenphosphate in fertilizer and, as indicator electrode, in potentiometric titration of HPO42? ion with barium chloride.  相似文献   

17.
A potassium ion-selective electrode based on a cobalt(II)-hexacyanoferrate(III) (CHCF) film-modified glassy carbon electrode is proposed. The electroactive film is introduced onto the glassy carbon electrode surface by electrodeposition of cobalt, which forms a thin CHCF film on subsequent anodic scanning in KClHCl solution (pH 5.0–5.5) containing K3Fe(CN)6. The thickness of the film on the electrode surface can be controlled by changing the electrodeposition time and the concentrations of cobalt(II) and Fe(CN)3?6 ions. The modified electrode exhibits a linear response in the concentration range 1 × 10?1 ?3 × 10?5 M potassium ion activity, with a near-Nernstian slope (48–54 mV per decade) at 25 ± 1°C. The detection limit is 1 × 10?5 M. The stability, response time and selectivity were investigated. The electrode exhibits good selectivity for potassium ion with the twelve cations investigated. The relative standard deviation is 1.5% (n=10). The effects of the thickness of the electroactive film and the pH of the solution on the electrode response were also investigated.  相似文献   

18.
A highly selective polyvinylchloride (PVC) membrane electrode based on Schiff base complex i.e. [Cobalt (Salpen) (PBu3)] ClO4 · H2O (Salpen = bis(salycilaldehyde)propylene diamine) is reported as new carrier for thiocyanate selective electrode by incorporating the membrane ingredients on the surface of graphite electrodes. The proposed electrode possesses a very wide Nernestian linear range to thiocyanate from 1.0 × 10?6 to 1.0 × 10?1 M with slope of ?59.05 ± 0.91 mV per decade of thiocyanate concentration, very low detection limit (8.0 × 10?7 M) and good thiocyanate selectivity over the wide variety of other anions. Fast and stable response, good reproducibility, long-term stability, applicability over a wide pH range (2.8–9.8) are advantages of the reported electrode. The sensor has a response time of <5 s and can be used for at least 14 weeks without any considerable change in respective potential response. The proposed electrode was used for the determination of thiocyanate in saliva, wastewater and human urine with satisfactory results and good agreement with colorimetric as reference method.  相似文献   

19.
2,5-Dioxo-4-imidazolidinyl was used as an excellent sensing material in the preparation of a PVC membrane for a Ce(III)-selective sensor. The electrode shows a good selectivity for the Ce(III) ion with respect to most common cations including alkali, alkaline earth, transition, and heavy metal ions. The developed sensor exhibits a wide linear response with a slope of 19.6?±?0.3 mV per decade over the concentration range of 1.0?×?10?6 to 1.0?×?10?1 M, while the illustrated detection limit is 5.7?×?10?7 M of Ce(III) ions. Moreover, it is concluded that the sensor response is pH-independent in the range of 3.1–9.8. The applications of the recommended electrode include the determination of concentration of Ce(III) ions in soil and sediment samples, validation with CRM's, and the Ce(III) ion potentiometric titration with EDTA as an indicator electrode.  相似文献   

20.
《Analytical letters》2012,45(4):683-695
Abstract

A highly selective and sensitive triiodide sensor based on a 2‐(((2‐(((E)‐1‐(2‐hydroxy phenyl) methylidine) amino) phenyl) imino) methyl) phenol with iodine (CTC) as membrane carrier was developed. The electrode revealed a Nernstian behavior over a very wide triiodide‐ion concentration range (5.0×10?8–1.0×10?2 M), and relatively low detection limit (3.0×10?8 M). The potentiometric response is independent of the pH of solution in the pH range of 3.0–10.0. The electrodes manifest advantages of low resistance, very fast response (<12 s), and most importantly, good selectivities relative to a wide variety of inorganic and organic anions, including iodide, bromide, chloride, fluoride, sulfite, sulfate, cyanide, thiocyanate, and acetate. In fact, the selectivity behavior of the proposed triiodide ion‐selective electrode shows great improvements compared to the previously reported electrodes for the triiodide ion. The proposed membrane sensor can be used for at least 6 months without any significant divergences in the potential. The electrode was successfully applied as an indicator electrode in the titration of triiodide with thiosulfate ion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号