首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
A fast, sensitive, and centrifugeless ultrasound‐assisted emulsification microextraction followed by a high‐performance liquid chromatography method is developed for the determination of some phthalate esters in aqueous samples. In this method, a simple approach is followed to eliminate the centrifugation step in dispersive liquid–liquid microextraction using an organic solvent whose melting point is near the ambient temperature, consumption of the extracting solvent is efficiently reduced, and the overall extraction time was found to be only 7 min. The variables affecting the method are optimized. Under the optimal experimental conditions (75 μL of 1‐undecanol, a flow rate of 2.0 mL/min, and an ultrasound irradiation of 1 min), the proposed method exhibits good preconcentration factors (52–97), low limits of detection (1.0–5.0 ng/mL), and linearities in the range of 5–1500 ng/mL (r 2 ≥ 0.995). Finally, the method is successfully applied to the analysis of phthalate esters in the drinking and river water samples. To study the probable release of the phthalate esters from a polyethylene container into boiling water, the boiling water exposed to the polyethylene container was analyzed by the proposed method.  相似文献   

2.
A new method was developed for the trace determination of phthalic acid esters in plasma using dispersive liquid–liquid microextraction and gas chromatography with mass spectrometry analysis. Plasma proteins were efficiently precipitated by trichloroacetic acid and then a mixture of chlorobenzene (as extraction solvent) and acetonitrile (as dispersive solvent) rapidly injected to clear supernatant using a syringe. After centrifuging, chlorobenzene sedimented at the bottom of the test tube. 1 μL of this sedimented phase was injected into the gas chromatograph for phthalic acid esters analysis. Different factors affecting the extraction performance, such as the type of extraction and dispersive solvent, their volume, extraction time, and the effects of salt addition were investigated and optimized. Under the optimum conditions, the enrichment factors and extraction recoveries were satisfactory and ranged between 820–1020 and 91–97%, respectively. The linear range was wide (50–1000 ng/mL) and limit of detection was very low (1.5–2.5 ng/mL for all analytes). The relative standard deviations for analysis of 1 μg/mL of the analytes were between 3.2–6.1%. Salt addition showed no significant effect on extraction recovery. Finally, the proposed method was successfully utilized for the extraction and determination of the phthalic acid esters in human plasma samples and satisfactory results were obtained.  相似文献   

3.
A simple and sensitive method for the determination of organophosphate esters in water samples by mixed‐mode liquid chromatography with electrospray ionization tandem mass spectrometry coupled with solid‐phase extraction is developed. Using seven alkyl phosphates, three chlorinated alkyl phosphates, and four aryl phosphates as the targets, the developed method was systematically evaluated on the basis of the influence of the solid‐phase extraction cartridge, eluting solvent, sample‐loading volume, mobile phase condition, and the separation of reversed‐phase chromatography and mixed‐mode liquid chromatography. Under the optimal conditions, these organophosphate esters can be extracted by ENVI‐18 cartridge, eluted by 6 mL of 25% dichloromethane in acetonitrile, and then qualified and quantified by mixed‐mode liquid chromatography with tandem mass spectrometry in the multiple reaction‐monitoring mode. The application of mixed‐mode liquid chromatography endows the separation with reasonable retention for both hydrophilic and hydrophobic organophosphate esters regardless of their polarity, which is hardly achieved by reversed‐phase chromatography. Good linearity (from 0.9877 to 0.9969), low quantification limits (1–35 ng/L after extraction of 100 mL of river water), and acceptable recovery rates (58.6–116.2%, with the relative standard deviation <18.0%) were obtained. Finally, the established method was used for analyzing surface water samples, and the good applicability of this method was demonstrated.  相似文献   

4.
Contaminants of emerging concern (CECs) such as per- and polyfluoroalkyl substances (PFAS) have attracted significant interest from researchers, policymakers, and water treatment facilities. This is because PFAS are highly persistent in the environment and tend to be bio-accumulative thus causing adverse effects on terrestrial and aquatic life. Therefore, there is a need for simpler and fast methods for the determination of PFAS in water sources. This work aims at the application of dispersive magnetic solid-phase extraction (DMSPE) for the enrichment of PFAS in various surface water samples. Magnetic Fe3O4@MIL-101 (Cr) was used as an adsorbent in MSPE. Fe3O4@MIL-101(Cr) was used for the first time for the preconcentration and extraction of PFAS in various river water samples. The concentrations of target analytes in water samples were determined using high performance liquid chromatography-diode array detector and ultra-high performance liquid chromatography-tandem mass spectrometry analysis. The combination of optimized DMSPE with HPLC-DAD and UHPLC-MS/MS provided wide linear range (1–5000 ng/L and 0.05–2000 ng/L, low limits of detection (0.3–0.66 ng/L and 0.011–0.04 ng/L) and limits of quantification (1.0–2.2 ng/L and 0.04–0.12 ng/L). Moreover, acceptable intraday and interday precision based on the relative standard deviation (RSD) lower than 5% were obtained. The developed method showed remarkable practicability for the analysis of ultra-trace PFAS in water samples.  相似文献   

5.
A stir bar sorptive extraction method coupled with deep eutectic solvent based solidification of floating organic droplets–dispersive liquid–liquid microextraction has been used for the simultaneous derivatization and extraction of some acidic pesticides in tomato samples. In this method, initially the analytes are adsorbed on a coated stir bar from tomato juice filled in a narrow tube. After extraction, the stir bar is removed and a water–miscible deep eutectic solvent is used to elute the analytes. Afterward, a derivatization agent and a water–immiscible deep eutectic solvent (as an extraction solvent) with melting point near to room temperature are added to the obtained eluant at µL–levels and the obtained mixture is rapidly injected into deionized water. Under the optimum conditions, the introduced method indicated high enhancement (1543–3353) and enrichment (2530–2999) factors, low limits of detection (7–14 ng/L) and quantification (23–47 ng/L), good linearity (r2 ≥ 0.9982), and satisfactory repeatabilities (relative standard deviation ≤12% for intra– and inter–day precisions at a concentration of 100 ng/L of each analyte). Finally, the proposed method was applied in analysis of the analytes in tomato samples.  相似文献   

6.
Chitosan‐grafted polyaniline was synthesized and applied as a sorbent for the preconcentration of phthalate esters in dispersive solid‐phase extraction. By coupling dispersive solid‐phase extraction with high‐performance liquid chromatography and response surface methodology (central composite design), a reliable, sensitive, and cost‐effective method for simultaneous determination of phthalate esters including dimethyl phthalate, di‐n‐butyl phthalate, and di(2‐ethylhexyl)phthalate was developed. The morphology of sorbent had been studied by scanning electron microscopy and its chemical structure confirmed by Fourier transform infrared spectroscopy. Under optimum condition, good linearity was observed in the range of 5.0–5000.0 ng/mL. The limits of detection (S/N = 3) and limits of quantification (S/N = 10) were 0.1–0.3 and 0.3–1 ng/mL, respectively. The relative standard deviations were less than 8.8%. Finally, this procedure was employed for extraction of trace amounts of phthalic acid esters in milk samples, the relative recoveries ranged from 82 to 103%.  相似文献   

7.
This review includes one hundred and two peer reviewed papers that focus on metabolic residues of the two most used licit drugs globally, nicotine (nicotine, cotinine, trans-3’-hydroxycotinine – HCOT) and alcohol (ethyl sulphate and ethyl glucuronide), in waste- and environmental waters. Sampling strategies and analytical methods are also summarised and discussed. Although grab sampling is the most widely applied method for collecting environmental samples (74% cases), wastewater samples are typically composite samples collected automatically at the wastewater treatment plants (66% cases). Sample preparation and analysis usually include solid-phase extraction (SPE) followed by reverse-phased liquid chromatography with tandem mass spectrometry detection (RP-LC-MS/MS) for nicotine residues. In contrast, alcohol residues are commonly determined via direct injection onto the LC-MS/MS using an ion-pair reagent to improve retention, leaving room for method improvement, e.g., introducing a suitable extraction procedure to achieve lower detection limits and quantification. In comparison to alcohol residues, more studies look into nicotine residues (85% of the studies). Concentration ranges for nicotine, cotinine, HCOT and ethyl sulphate were < 424,000, < 42,300, 50–52,000 and 500–33,000 ng/L in wastewater influents and 15–32,000, < 18,000, 15–1,552 and < 500 ng/L in effluents, while nicotine (12.6–947 ng/L) and cotinine (17–62 ng/L) were detected in reclaimed waters. Among environmental waters, the highest concentrations of nicotine residues were measured in surface waters (nicotine: < 9,340 ng/L, cotinine: < 6,582 ng/L and HCOT: 14–777 ng/L), while their concentrations in groundwater and drinking water were generally in the low ng/L range. This review also reveals the discrepancy between the number of studies in developed countries (90%) compared to developing countries and the need for more studies in the former, where most wastewater flows untreated into the environment.  相似文献   

8.
In this study, ionic liquid (IL) supported magnetic dispersive solid‐phase microextraction was developed and a systematic investigation was conducted on imidazolium ILs for their extraction performance. This nano‐based pretreatment procedure was then applied for the determination of acaricides in fruit juice samples for the first time. A feature of this technique is that the commonly laborious chemical modification of magnetic nanoparticles (MNPs) was skillfully circumvented. Because of the combination of ILs, dispersive liquid–liquid microextraction, and dispersive MNP solid‐phase microextraction, the extraction efficiency can be significantly improved using commercial MNPs. Parameters of the extraction method were investigated by one‐factor‐at‐a‐time approach. The optimal experimental conditions were as follows: emulsification for 2 min by sonication with the addition of 50 μL [C6MIM][NTf2] in the dispersive liquid–liquid microextraction step and vortexing for 90 s after adding 40 mg spherical barium ferrite nanoparticles (20 nm). The desorption time was 2 min. Good linearity (0.5–500 ng/mL) and detection limits within the range of 0.05–0.53 ng/mL were achieved. The application of the proposed method was demonstrated by the analysis of real fruit juice samples, in which recoveries between 85.1 and 99.6% were obtained.  相似文献   

9.
Quick, easy, cheap, effective, rugged, and safe extraction strategies are becoming increasingly adopted in various analytical fields to determine drugs in biological specimens. In the present study, we developed two fully automated quick, easy, cheap, effective, rugged, and safe extraction methods based on acetonitrile salting-out assisted liquid-liquid extraction (method 1) and acetonitrile salting-out assisted liquid-liquid extraction followed by dispersive solid-phase extraction (method 2) using a commercially available automated liquid-liquid extraction system. We applied these methods to the extraction of 14 psychotropic drugs (11 benzodiazepines and carbamazepine, quetiapine, and zolpidem) from whole blood samples. Both methods prior to liquid chromatography–tandem mass spectrometry analysis exhibited high linearity of calibration curves (correlation coefficients, > 0.9997), ppt level detection sensitivities, and satisfactory precisions (< 8.6% relative standard deviation), accuracies (within ± 16% relative error), and matrix effects (81–111%). Method 1 provided higher recovery rates (80–91%) than method 2 (72–86%), whereas method 2 provided higher detection sensitivities (limits of detection, 0.003–0.094 ng/mL) than method 1 (0.025–0.47 ng/mL) owing to the effectiveness of its dispersive solid-phase extraction cleanup step. These fully automated extraction methods realize reliable, labor-saving, user-friendly, and hygienic extraction of target analytes from whole blood samples.  相似文献   

10.
The precise control of pesticide residues in foodstuffs depends significantly on the clean extraction of analytes using specifically designed separation methods. In this study, a one‐pot sol–gel process was used for the preparation of a magnetic hybrid silica gel tetraethylortho silicate‐cyanopropyltriethoxy silane nanocomposite. The prepared material was characterized using energy dispersive X‐ray spectroscopy, Fourier transform infrared spectroscopy, single‐point specific surface area, and scanning electron microcopy. The synthesized magnetic hybrid material was used as a solid phase extraction sorbent for the extraction and preconcentration of some organophosphorus pesticides before gas chromatography with a microelectron capture detector. The performance of the proposed magnetic solid‐phase extraction technique was validated by linearity (0.05–2 ng/mL), correlation coefficients (r= 0.9993–0.9997), limit of detection (0.02–0.06 ng/mL, S/N = 3, = 3), and intraday (RSD = 1.5–8.7%, = 3) and interday precision (RSD = 5.5–9.3%, = 12), while the recovery in real samples and equilibrium adsorption capacity was 72.02–103.84% and 8–20 mg/g, respectively. The magnetic solid‐phase extraction based on the hybrid nanocomposite revealed a high enrichment factor, an appropriate dynamic range, and great absorptive ability toward the selected organophosphorus pesticides spiked in real water samples.  相似文献   

11.
Organophosphate esters have been extensively used as flame retardants and plasticizers. The analysis of organophosphate esters in the environment is a hot topic because many of them are toxic and persistent. We developed a novel procedure for determining organophosphate esters in sediment. In this work, pressurized liquid extraction and solid‐phase microextraction are used for sample preparation to extract and concentrate the analytes, which are then analyzed by gas chromatography with flame photometric detection. The extraction parameters of pressurized liquid extraction were investigated and optimized by orthogonal design and then evaluated by range analysis and analysis of variance. Under the optimal conditions, the proposed procedure showed wide linear ranges (0.90–100 ng/g) with correlation coefficients ranging from 0.9921 to 0.9990. The detection limits of the method were in the range of 0.009–0.280 ng/g with standard deviations ranging from 2.2 to 9.5%. Recoveries of the proposed method ranged from 82.3 to 108.9% with relative standard deviations <8.4%. The obtained method was applied successfully to the determination of organophosphate esters in real sediments with recoveries varying from 79.8 to 107.3%. The proposed method was proved to be simple, easy, and sensitive for analyzing organophosphate esters in sediment samples.  相似文献   

12.
A novel and reliable method for determination of five triazole fungicide residues (triadimenol, tebuconazole, diniconazole, flutriafol, and hexaconazol) in traditional Chinese medicine samples was developed using dispersive solid‐phase extraction combined with ultrasound‐assisted dispersive liquid–liquid microextraction before ultra‐high performance liquid chromatography with tandem mass spectrometry. The clean up of the extract was conducted using dispersive solid‐phase extraction by directly adding sorbents into the extraction solution, followed by shaking and centrifugation. After that, a mixture of 400 μL trichloromethane (extraction solvent) and 0.5 mL of the above supernatant was injected rapidly into water for the dispersive liquid–liquid microextraction procedure. The factors affecting the extraction efficiency were optimized. Under the optimum conditions, the calibration curves showed good linearity in the range of 2.0–400 (tebuconazole, diniconazole, and hexaconazole) and 4.0–800 ng/g (triadimenol and flutriafol) with the regression coefficients higher than 0.9958. The limit of detection and limit of quantification for the present method were 0.5–1.1 and 1.8–4.0 ng/g, respectively. The recoveries of the target analytes ranged from 80.2 to 103.2%. The proposed method has been successfully applied to the analysis of five triazole fungicides in traditional Chinese medicine samples, and satisfactory results were obtained.  相似文献   

13.
The determination of 15 pyrethroids in soil and water samples was carried out by gas chromatography with mass spectrometry. Compounds were extracted from the soil samples (4 g) using solid–liquid extraction and then salting‐out assisted liquid–liquid extraction. The acetonitrile phase obtained (0.8 mL) was used as a dispersant solvent, to which 75 μL of chloroform was added as an extractant solvent, submitting the mixture to dispersive liquid–liquid microextraction. For the analysis of water samples (40 mL), magnetic solid‐phase extraction was performed using nanocomposites of magnetic nanoparticles and multiwalled carbon nanotubes as sorbent material (10 mg). The mixture was shaken for 45 min at room temperature before separation with a magnet and desorption with 3 mL of acetone using ultrasounds for 5 min. The solvent was evaporated and reconstituted with 100 μL acetonitrile before injection. Matrix‐matched calibration is recommended for quantification of soil samples, while water samples can be quantified by standards calibration. The limits of detection were in the range of 0.03–0.5 ng/g (soil) and 0.09–0.24 ng/mL (water), depending on the analyte. The analyzed environmental samples did not contain the studied pyrethroids, at least above the corresponding limits of detection.  相似文献   

14.
In the present work, a combination of microwave-assisted extraction with magnetic ionic liquid–based dispersive liquid–liquid microextraction was developed for the extraction of chloramine–T from fish samples. In this method, the sample was mixed with a hydrochloric acid solution and exposed to microwave irradiations. By doing so, chloramine–T was converted to p–toluenesulfonamide and extracted from the sample into an aqueous phase. Then, a mixture of acetonitrile (as a dispersive solvent) and magnetic ionic liquid (as an extraction solvent) was rapidly injected into the obtained solution. In the following, the magnetic solvent droplets including the extracted analytes were isolated from the aqueous solution in the presence of an external magnetic field and after diluting with acetonitrile injected into high-performance liquid chromatography equipped with a diode array detector. Under the optimum extraction conditions, high extraction recovery (78%), low limits of detection (7.2 ng/g) and quantification (23.9 ng/g), good repeatability (relative standard deviations ≤5.8 and 6.8% for intra– and inter-day precisions, respectively), and wide linear range (23.9–1000 ng/g) were obtained. Finally, various fish samples marketed in Tabriz city (East Azarbaijan, Iran) were analyzed with the suggested method.  相似文献   

15.
A three‐dimensional graphene was synthesized through a hydrothermal reaction of graphene oxide with phytic acid. The microstructure and morphology of the phytic acid induced three‐dimensional graphene were investigated by nitrogen adsorption–desorption isotherms, scanning electron microscopy, and transmission electron microscopy. With a large surface area and three‐dimensional structure, the graphene was used as the solid‐phase extraction adsorbent for the extraction of phthalate esters from bottled water and sports beverage samples before high‐performance liquid chromatographic analysis. The results indicated that the graphene was efficient for the solid‐phase extraction of phthalate esters. The limits of detection (S/N = 3) of the method for the analytes were 0.02–0.03 ng/mL for the water samples and 0.03–0.15 ng/mL for the sports beverage sample. The limits of quantitation (S/N = 9) for the analytes were 0.06–0.09 ng/mL for water samples and 0.09–0.45 ng/mL for sports beverage sample. The calibration curves for the phthalate esters by the method had a good linearity from 0.1 to 80.0 ng/mL with correlation coefficients larger than 0.9997. The recoveries of the analytes for the method fell in the range of 86.7–116.2% with the relative standard deviations between 1.5 and 6.8%.  相似文献   

16.
建立了C_(18)膜萃取/液相色谱-质谱联用技术测定极地水体中10种有机磷酸酯(OPEs)的方法。根据优化后的样品前处理及仪器方法,利用C_(18)膜富集4 L水体中的10种OPEs,经二氯甲烷超声提取,在电喷雾正离子模式下,采用选择反应监测(SRM)模式进行分析,线性相关系数为0.994 4~0.999 9。10种OPEs的加标回收率为64.1%~115%,方法检出限为0.08~0.55 ng/L。该方法适用于极地水体中10种OPEs的分析,利用该方法对北极水体样品中的10种OPEs进行检测,测得冰川融水中∑OPEs的质量浓度为0.64~6.64 ng/L,海水中∑OPEs的质量浓度为0.09~2.03 ng/L。  相似文献   

17.
A simple and sensitive method for the simultaneous determination of eight parabens in human plasma and urine samples was developed. The samples were preconcentrated using dispersive liquid–liquid microextraction based on the solidification of floating organic drops and determined by high‐performance liquid chromatography with ultraviolet detection. The influence of variables affecting the extraction efficiency was investigated and optimized using Placket–Burman design and Box–Behnken design. The optimized values were: 58 μL of 1‐decanol (as extraction solvent), 0.65 mL methanol (as disperser solvent), 1.5% w/v NaCl in 5.0 mL of sample solution, pH 10.6, and 4.0 min centrifugation at 4000 rpm. The extract was injected into the high‐performance liquid chromatography system for analysis. Under the optimum conditions, the linear ranges for eight parabens in plasma and urine were 1.0–1000 ng/mL, with correlation coefficients above 0.994. The limit of detection was 0.2–0.4 and 0.1–0.4 ng/mL for plasma and urine samples, respectively. Relative recoveries were between 80.3 and 110.7%, while relative standard deviations were less than 5.4%. Finally, the method was applied to analyze the parabens in 98 patients of primary breast cancer. Results showed that parabens existed widely, at least one paraben detected in 96.9% (95/98) of plasma samples and 98.0% (96/98) of urine samples.  相似文献   

18.
Magnetic spherical carbon was synthesized by a facile hydrothermal carbonization procedure with biomass glucose as the carbon precursor and nanoclusters iron colloid as magnetic precursor. The textures of the as‐prepared magnetic spherical carbon were characterized by nitrogen adsorption–desorption isotherms, X‐ray diffraction, transmission electron microscopy, scanning electron microscopy and vibration sample magnetometry. Results indicated that the magnetic spherical carbon possessed high surface area as well as strong magnetism, which endows the material with good adsorption capability and easy separation properties. To assess its absorption performance, the magnetic spherical carbon was employed as adsorbent for the extraction and preconcentration of phthalate esters from lake water and milk samples before high‐performance liquid chromatographic analysis. Some key parameters that could influence the enrichment efficiency were investigated. Under the optimum conditions, a good linearity was achieved with the linear correlation coefficients higher than 0.9973. The limits of detection (S/N = 3) were 0.05–0.08 ng/mL for lake water and 0.1–0.2 ng/mL for milk samples. The recoveries of the analytes for the method were in the range 80.1–112.6%.  相似文献   

19.
A simple, rapid, and novel method has been developed and validated for determination of seven indicator polychlorinated biphenyls in water samples by gas chromatography with electron capture detection. 1 L of water samples containing 30 g of anhydrous sodium sulfate was first liquid–liquid extracted with an automated Jipad‐6XB vertical oscillator using n‐hexane/dichloromethane (1:1, v/v). The concentrated extract was cleaned up by dispersive solid‐phase extraction with 100 mg of primary secondary amine as sorbent material. The linearity of this method ranged from 1.25 to 100 μg/L, with regression coefficients ranging between 0.9994 and 0.9999. The limits of detection were in the ng/L level, ranging between 0.2 and 0.3 ng/L. The recoveries of seven spiked polychlorinated biphenyls with external calibration method at different concentration levels in tap water, lake water, and sea water were in the ranges of 85–112, 76–116, and 72–108%, respectively, and with relative standard deviations of 3.3–4.5, 3.4–5.6, and 3.1–4.8% (n =  5), respectively. The performance of the proposed method was compared with traditional liquid–liquid extraction and solid‐phase extraction clean‐up methods, and comparable efficiencies were obtained. It is concluded that this method can be successfully applied for the determination of polychlorinated biphenyls in different water samples.  相似文献   

20.
Dispersive liquid–liquid microextraction method was developed for the determination of the amount of phthalate esters in bottled drinking water samples and dispersive liquid–liquid microextraction samples were analyzed by GC–MS. Various experimental conditions influencing the extraction were optimized. Under the optimized conditions, very good linearity was observed for all analytes in a range between 0.05 and 150 μg/L with coefficient of determination (R2) between 0.995 and 0.999. The LODs based on S/N = 3 were 0.005–0.22 μg/L. The reproducibility of dispersive liquid–liquid microextraction was evaluated. The RSDs were 1.3–5.2% (n = 3). The concentrations of phthalates were determined in bottled samples available in half shell. To understand the leaching profile of these phthalates from bottled water, bottles were exposed to direct sunlight during summer (temperature from 34–57°C) and sampled at different intervals. Result showed that the proposed dispersive liquid–liquid microextraction is suitable for rapid determination of phthalates in bottled water and di‐n‐butyl, butyl benzyl, and bis‐2‐ethylhexyl phthalate compounds leaching from bottles up to 36 h. Thereafter, degradation of phthalates was observed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号