首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
We present an environmentally friendly method for the analysis of three angiotensin‐converting enzyme inhibitors and hydrochlorothiazide simultaneously using a green micellar eluent for the first time. The chromatographic separation of enalapril maleate, lisinopril dihydrate, benazepril hydrochloride, and hydrochlorothiazide was implemented on an octadecyl silica column with a solution containing sodium dodecyl sulfate (0.12 M), 1‐propyl alcohol (10% v/v), triethylamine (0.3% v/v), and H3PO4 (0.02 M) at pH 3.6 as the mobile phase and UV detection at 210 nm. Validity of the method was confirmed and it exhibited good linearity within the ranges of 5.0–50.0 μg/mL for hydrochlorothiazide and 10.0–60.0 μg/mL for the three angiotensin‐converting enzyme inhibitors with a limit of detection of 0.39 to 1.15 μg/mL for all the studied drugs. The developed micellar high‐performance liquid chromatography method enables the quantification of the targeted angiotensin‐converting enzyme inhibitors in combined tablets with hydrochlorothiazide by isocratic elution. There is no need for special precautions to prevent broadening and splitting of their chromatographic peaks. The method fulfills the society rights for safe and green analytical methods. The retention behavior of the four studied drugs was fitted to Foley's model and their association equilibria to the micelles (K AM) and to the surface‐modified stationary phase (K AS) were calculated.  相似文献   

2.
A reversed‐phase high‐performance liquid chromatography method was developed for the simultaneous determination of the diuretic, hydrochlorothiazide, along with six drugs representing the most commonly prescribed antihypertensive pharmacological classes such as atenolol, a selective β1 blocker, amlodipine besylate, a calcium channel blocker, moexipril hydrochloride, an angiotensin‐converting‐enzyme inhibitor, valsartan and candesartan cilexetil, which are angiotensin II receptor blockers, and aliskiren hemifumarate, a renin inhibitor, using irbesartan as an internal standard. The chromatographic separation was achieved using acetonitrile/sodium phosphate dibasic buffer (0.02 M, pH 5.5) at a flow rate of 1 mL/min in gradient elution mode at ambient temperature on a stationary phase composed of an Eclipse XDB‐C18 (4.6 × 150 mm, 5 μm) column. UV detection was carried out at 220 nm. The method was validated according to ICH guidelines. Linearity, accuracy, and precision were satisfactory over the concentration ranges of 2–40 μg/mL for hydrochlorothiazide and candesartan cilexetil, 20–120, 10–160, 5–40, 20–250, and 5–50 μg/mL for atenolol, valsartan, moexipril hydrochloride, aliskiren hemifumarate, and amlodipine besylate, respectively. The method was successfully applied for the determination of each of the studied drugs in their combined formulations with hydrochlorothiazide. The developed method is suitable for the quality control and routine analysis of the cited drugs in their pharmaceutical dosage forms.  相似文献   

3.
A fast, green, sensitive, and accurate analytical method using high‐performance liquid chromatography couple with fluorescence detection was established and validated for the simultaneous determination of amlodipine besylate and celecoxib in their recently approved fixed‐dose combination tablets (1:20). Separation of the two drugs was achieved on C18 reversed‐phase column (Thermo ODS Hypersil, 4.6 × 250 mm, particle size 5 µm) using acetonitrile:potassium phosphate buffer (50 mM; pH 5.5, 60:40 v/v) as a mobile phase at 40°C, which eluted at a rate of 1 mL/min. Detection was carried out with excitation and emission wavelengths of 360 and 446 nm for amlodipine and 265 and 359 nm for celecoxib, respectively. The method was linear over a concentration range of 0.05‐2 and 0.05‐10 µg/mL and limit of detection reached to 0.017 and 0.0167 µg/mL for amlodipine and celecoxib, respectively. The developed method was successfully applied to assess the cited drugs in their newly FDA approved fixed‐dose combination tablet dosage form. Furthermore, the method was found to be sensitive and eco‐friendly green alternative to the reported methods as it was evaluated according to the green analytical procedure index tool guidelines and analytical Eco‐Scale.  相似文献   

4.
Determination of a widely used antihypertensive combination of atenolol and hydrochlorothiazide was achieved by rapid and eco-friendly high-performance liquid chromatography method combined with fluorescence detection. The response surface methodology is conducive to the complete separation of the two drugs in a shorter analysis time. The separation of the mixture was achieved using an Inertsil C18 analytical column (150 × 4.6 mm, 5 µ). The mobile phase used was ethanol: potassium dihydrogen phosphate at pH 3 (65:35 v/v) and the flow rate was 0.7 mL/min. The fluorescence detector operated at excitation and emission wavelengths of 230 and 310 nm (atenolol) and 270 and 375 nm (hydrochlorothiazide). The linearity of the developed method covered a concentration of atenolol of 0.05–5 µg/mL and a concentration of hydrochlorothiazide of 0.02–1 µg/mL. The greenness of the developed method was evaluated by analytical eco-scale and the recently reported evaluation method, that is, green analytical procedure index, and it was found to be an excellent, sensitive, and green alternative to the reported methods. The developed method was validated according to the ICH guidelines and compared with the reference method. No significant difference was found in terms of accuracy.  相似文献   

5.
A systematic Quality by Design approach was employed for developing an isocratic reversed‐phase liquid chromatographic technique for the estimation of ropinirole hydrochloride in bulk drug and pharmaceutical formulations. LiChrospher RP 18‐5 Endcapped column (25 cm × 4.6 mm id) at ambient temperature (25 ± 2°C) was used for the chromatographic separation of the drug. The screening of factors influencing chromatographic separation of the active pharmaceutical ingredient was performed employing fractional factorial design to identify the influential factors. Optimization of the selected factors was carried out using central composite design for selecting the optimum chomatographic conditions. The mobile phase employed was constituted of Solvent A/Solvent B (65:35 v/v) (Solvent A [methanol/0.05 M ammonium acetate buffer, pH 7, 80:20 v/v] and Solvent B [high performance liquid chromatography grade water]) and used at 0.6 mL/min flow rate, while UV detection was performed at 250 nm. Linearity was achieved in the drug concentration range 5–100 µg/mL (R= 0.9998) with limits of detection and quantification of 1.02 and 3.09 µg/mL, respectively. Method validation was performed as per ICH guidelines followed by forced degradation studies, which indicated good specificity of the developed method for detecting ropinirole hydrochloride and its possible degradation products in the bulk drug and pharmaceutical formulations.  相似文献   

6.
The performances of core–shell 2.7 μm and fully porous sub‐2 μm particles packed in narrow diameter columns were compared under the same chromatographic conditions. The stationary phases were compared for fast separation and determination of five new antiviral drugs; daclatasvir, sofosbuvir, velpatasvir, simeprevir, and ledipasvir. The gradient elution was done using ethanol as green organic modifier, which is more environmentally friendly. Although both columns provided very good resolution of the five drugs, core–shell particles had proven to be of better efficiency. Under gradient elution conditions, core–shell particles exhibited faster elution, better peak shape, and enhanced resolution adding to lower system backpressure. The column backpressure on sub‐2 μm particles was more than twice that on core–shell particles. This gives a chance to use conventional high‐performance liquid chromatography conditions without needing special instrumentation as that required for ultra‐high performance liquid chromatography. The method was validated for determination of the five drugs by gradient elution using mobile phase composed of organic modifier ethanol and aqueous part containing 0.75 g sodium octane sufonate and 3.0 g sodium dihydrogen phosphate per liter at pH of 6.15. Detection was done using UV‐detector set at 210 nm. The linearity, accuracy, and precision were found very good within the concentration range of 2–200 μg/mL.  相似文献   

7.
A simple and rapid ultra‐high‐performance liquid chromatographic (UHPLC) for the simultaneous determination of meropenem and ciprofloxacin in human plasma was developed and validated. All of the analytes were separated in <5 min. A solid‐phase extraction method was applied from sample preparation. Analytical separation was performed on a Poroshell SB C18 column (50 × 2.1 mm, 2.7 μm particle size) with photodiode array (PDA) detection. Meropenem and ciprofloxacin were determined at wavelengths of 300 and 277 nm, respectively. The mobile phase was a mixture of acetonitrile–10 mm ammonium acetate–methanol in gradient elution. The method has been validated for both drugs in gastric surgery for cancer patients. The method showed good linearity with correlation coefficients, r2 = 0.994 for the two drugs, as well as high precision (RSD < 10.5% in each case); accuracy ranged from ?5.8 to +6.0%. The limit of quantitation of the two drugs was established at 0.02 and 0.01 μg/mL, respectively. Meropenem, ciprofloxacin and the internal standard were extracted from human plasma with a mean recovery ranging from 92.5 to 98.6%. The method was applied to quantify the drugs dosage in complicated gastric surgery patients.  相似文献   

8.
Portable infusion pumps are an interesting solution to continue outpatient parenteral antimicrobial therapy (OPAT) at the patient's home. However, the use of ceftazidime for such applications is challenging in view of its relatively poor stability in solution. In this study, elastomeric infusion pumps with 6 or 7 g of ceftazidime were deflated over 24 h in an oven at 33°C while ceftazidime and its degradation product, pyridine, were regularly monitored. Hereto, a fast and sensitive liquid chromatographic (LC) method has been developed using a Kinetex® C18 (150 × 3 mm, 2.6 μm) column with gradient elution. Ammonium formate 20 mM and acetonitrile (ACN) were mixed in a ratio of 98:2 v/v for mobile phase A and 85:15 v/v for mobile phase B. Both were adjusted to pH 4.5 with formic acid. The flow rate was set at 0.4 mL/min. The solution with a starting dose of 6 g ceftazidime was found to be degraded 10% after an average of 19 h 11 min so that an administration of 6 g to the patient was not reached. For the solution with a starting dose of 7 g of ceftazidime, 10% degradation was observed after an average of 18 h 42 min. However, by starting from a higher dose, an average of 6.56 g of ceftazidime could be administered over 24 h. In addition, 1.0% of pyridine versus ceftazidime pentahydrate with sodium carbonate (=mixture for injection) was formed over 24 h.  相似文献   

9.
A simple and sensitive stability-indicating chiral HPLC method has been developed and validated per International Conference on Harmonization guidelines for the determination of enantiomeric purity of eluxadoline (Exdl). The impact of different mobile phase compositions and chiral stationary phases on the separation of Exdl enantiomer along with process- and degradation-related impurities has been studied. Homogeneity of Exdl and stable results of Exdl enantiomer in all degraded samples reveal the fact that the proposed method was specific (stability indicating). Amylose tris(3,5-dichlorophenyl carbamate) stationary phase column Chiralpak IE-3 (150 × 4.6 mm, 3 μm) provided better resolution with polar organic solvents than cellulose derivative, crown ether, and zwitterion stationary phases and nonpolar solvents. The mobile phase consisted of acetonitrile, tetrahydrofuran, methanol, butylamine, and acetic acid in the ratio of 500:500:20:2:1.5 (v/v/v/v/v). Isocratic elution was performed at a flow rate of 1.0 mL/min, column temperature of 35°C, injection volume of 10 μL, and UV detection of 240 nm. The United States Pharmacopeia (USP) resolution of the Exdl enantiomer was found to be more than 4.0 within a 65-min run time. Exdl enantiomer detector response linearity over the concentration range of 0.859–4.524 μg/mL was found to be R2 = 0.9985. The limit of detection, limit of quantification, and average percentage recovery values were established as 0.283 μg/mL, 0.859 μg/mL, and 96.0, respectively.  相似文献   

10.
Two specific, sensitive, and precise stability indicating chromatographic methods have been developed, optimized, and validated for Hydrochlorothiazide (HCT) and Spironolactone (SPR) determination in their mixtures and in presence of their impurities and degradation products. The first method was based on thin layer chromatographic (TLC) combined with densitometric determination of the separated spots. The separation was achieved using silica gel 60 F(254) TLC plates and ethyl acetate-chloroform-formic acid-triethyl amine (7:3:0.1:0.1, by volume) as a developing system. Good correlations were obtained between the integrated peak area of the studied drugs and their corresponding concentrations in different ranges. The second method was based on the high-performance liquid chromatography with ultraviolet detection, by which the proposed components were separated on a reversed phase C(18) analytical column using gradient elution system with deionized water-acetonitrile (97:3, v/v) for 8 min. Then acetonitrile was successively increased to 35% in the next 2 min, and kept constant in the following 10 min, finally 3% acetonitrile was regained again to stabilize the chromatographic system. The flow rate was maintained at 2 mL/min and the detection wavelength was at 230 nm. Linear regressions were obtained in the range of 4.0-50 μg/mL and 5.0-50 μg/mL for both HCT and SPR, respectively. Different parameters affecting the suggested methods were optimized for maximum separation of the cited components. System suitability parameters of the two developed methods were also tested. The suggested methods were validated in compliance with the ICH guidelines and were successfully applied for determination of HCT and SPR in their commercial tablets. Both methods were also statistically compared to each other and to the reported method with no significant difference in performance.  相似文献   

11.
A novel graphene/dodecanol floating solidification microextraction followed by HPLC with diode‐array detection has been developed to extract trace levels of four cinnamic acid derivatives in traditional Chinese medicines. Several parameters affecting the performance were investigated and optimized. Also, possible microextraction mechanism was analyzed and discussed. Under the optimum conditions (amount of graphene in dodecanol: 0.25 mg/mL; volume of extraction phase: 70 μL; pH of sample phase: 3; extraction time: 30 min; stirring rate: 1000 rpm; salt amount: 26.5% NaCl; volume of sample phase: 10 mL, and without dispersant addition), the enrichment factors of four cinnamic acid derivatives ranged from 26 to 112, the linear ranges were 1.0 × 10−2–10.0 μg/mL for caffeic acid, 1.3 × 10−3–1.9 μg/mL for p‐hydroxycinnamic acid, 2.8 × 10−3–4.1 μg/mL for ferulic acid, and 2.7 × 10−3–4.1 μg/mL for cinnamic acid, with r 2 ≥ 0.9993. The detection limits were found to be in the range of 0.1–1.0 ng/mL, and satisfactory recoveries (92.5–111.2%) and precisions (RSDs 1.1–9.5%) were also achieved. The results showed that the approach is simple, effective and sensitive for the preconcentration and determination of trace levels of cinnamic acid derivatives in Chinese medicines. The proposed method was compared with conventional dodecanol floating solidification microextraction and other extraction methods.  相似文献   

12.
In this study, a sensitive high‐performance liquid chromatography method was developed and validated for the simultaneous determination of seven angiotensin II receptor blockers, namely, hydrochlorothiazide, chlorthalidone, eprosartan mesylate, valsartan, losartan potassium, irbesartan, and candesartan cilexetil. Different chromatographic parameters were tested and fully optimized. Best chromatographic separation was accomplished on a reversed‐phase octadecylsilyl column (250 × 4.6 mm id; 5 μm) under gradient elution using methanol/sodium phosphate monobasic buffer (0.01 M, pH 6.5) as mobile phase. The detection of target analytes was obtained at 254 nm. The pH of the buffer has been selected according to Marvin® sketch software. The proposed method was validated according to ICH guidelines and showed good precision (relative standard deviation < 1), good linearity (square of correlation coefficient ≥ 0.999), and high accuracy (between 98 and 102%) with detection limit and quantitation limit (40 and 160 ng/mL, respectively) for all the detected analytes.  相似文献   

13.
A simple, rapid, and precise reversed-phase high-performance liquid chromatographic method for the simultaneous determination of lamivudine, tenofovir disoproxil fumarate and efavirenz in bulk and tablet dosage form has been developed and validated. Chromatography was performed on a 150 mm × 4.6 mm i.d., 5-μm particle, Phenomenex Luna C18 column with 30: 45: 25 (v/v/v) acetonitrile: methanol: water as mobile phase at a flow rate of 0.5 mL/min. UV detection was done at 258 nm; lamivudine, tenofovir disoproxil fumarate and efavirenz were eluted with retention times of 3.27, 4.58 and 10.90 min, respectively. The method was validated in accordance with ICH guidelines. Validation revealed the method is specific, rapid, accurate, precise, reliable and reproducible. Calibration plots were linear over the concentration ranges 1–6 μg/mL for lamivudine and tenofovir disoproxil fumarate and 2–12 μg/mL for efavirenz. Limits of detection were 0.05, 0.09 and 0.11 μg/mL and limits of quantification were 0.15, 0.28 and 0.34 μg/mL for lamivudine, tenofovir disoproxil fumarate and efavirenz, respectively. The high recovery and low coefficients of variation confirm the suitability of the method for the simultaneous determination of these three drugs in bulk and tablets.  相似文献   

14.
A green and robust reverse-phase liquid chromatographic method has been developed for the determination of fenoverine (FEN), by applying combined principles of green analytical chemistry and quality by design approaches on a Spherisorb C18 column (150?×?4.6?mm, 3?µm) with UV detection at 262?nm. A two level fractional factorial design (2^7-3) Res IV was used for screening of influential chromatographic factors. The critical method parameters actively affecting critical quality attributes (CQAs) were identified and further optimized using Box–Behnken design. The predicted optimum assay conditions comprised of methanol and ammonium acetate buffer 20?mM, in an extent of 81:19% v/v individually having a flow rate of 1.0?mL/min with a column oven temperature of 33°C. The drug was stressed in hydrolytic, oxidative, reductive, thermal, and photolytic conditions. The developed method was validated successfully. The detector response was linear in the concentration of 0.5–160?µg/mL with a limit of detection (LOD) and limit of quantitation (LOQ) as 0.1 and 0.3?µg/mL, respectively. The % recovery was found to be 99.7%. The analytical method volume intensity value for developed method was 45?mL and the environment assessment tool (EAT) score was 41.07. The method is simple, environmentally benign, rapid, and robust for the determination of FEN in bulk and in its dosage form.  相似文献   

15.
This paper describes a simple method for the simultaneous determination and confirmation of the indandione rodenticides in serum. After samples were extracted with 10% (v/v) methanol in acetonitrile and cleaned by solid‐phase extraction, chromatographic separation was performed on an IonPac® AS11 analytical column (250 × 4.0 mm) using gradient KOH eluent with 10% (v/v) methanol as organic modifier. Confirmation was depended on the extensive fragmentation of the indandione molecule under MS/MS conditions which provides sufficient structural information. Quantification was performed by negative electrospray ionization in multiple reaction monitoring mode. All the method parameters were validated. It was confirmed that this method could be used in clinical diagnosis and forensic toxicology. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
《印度化学会志》2023,100(9):101060
Monobenzone, a mono benzyl ether of hydroquinone, is used as a topical drug for skin depigmentation. It increases the excretion of melanin from melanocytes. A novel stability-indicating high performance liquid chromatographic approach has been established in the current study to identify related compounds and assay of Monobenzone. The Agilent 1260 system was used for the HPLC analysis, and a gradient method using 0.1% orthophosphoric acid in water and acetonitrile as the eluent was used to separate Monobenzone from known contaminants and degradation products on a Zorbax SB-phenyl (250 mm x 4.6 mm) 5 μm column. The flow rate was set at 0.8 mL/min, the column oven temperature was 30 °C, and the detector wavelength was maintained at 215 nm. The relative retention times for Hydroquinone and Monobenzone dimer were around 0.35 and 1.86 respectively, while the Monobenzone retention time was approximately 10.4 min. The total run time was 30 min. For all known analytes spanning the concentration range from LOQ to 200% of the specification level, the calibration plot revealed a linear relationship (minimum r=0.999). All known analytes' LOD and LOQ were found to be within 0.06–0.10 μg/mL and 0.15–0.24 μg/mL, respectively. A recovery study determined the accuracy of the proposed method. For Hydroquinone and Monobenzone dimer, mean recovery was found to be in the range of 95.86%–99.89% and 93.02%–99.84% respectively. The repeatability study showed that the method is precise enough within acceptable limits. Studies on solution stability and robustness produced results that fell within acceptable bounds. The proposed method shows excellent linearity, accuracy, precision, specificity, robustness, LOD, LOQ and system suitability findings. Additionally, the forced degradation study showed that the approach was stability indicating in nature.  相似文献   

17.
A simple high‐performance liquid chromatographic (HPLC) method with photometric detection is described for the determination of vardenafil hydrochloride, a phosphodiesterase V inhibitor, in human plasma. Chromatographic separation of the analyte and internal standard was achieved on an analytical 250 × 4.6 mm i.d. reversed‐phase Kromasil KR 100 C18 (5 µm particle size) column using a mobile phase of acetonitrile–potassium dihydrogen phosphate (30:70 v/v). The run time was less than 15 min. Column eluate was monitored at 230 nm. The linearity over the concentration range of 10–1500 ng/mL for vardenafil was obtained and the limit of quantification (LOQ) was 10 ng/mL. The method has been applied to analysis of the vardenafil concentrations for application in pharmacokinetic studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
Cyclohex-3-enyl(5-phenyl-4H-1,2,4-triazol-3-yl)methanol (MSDRT 12) is a novel triazole-based antitubercular compound with two chiral centres. Evaluation of the enantio-specific antitubercular activity has established that the stereoisomer 3 of MSDRT12 (Isomer 3) was the most potent isomer with a minimum inhibitory concentration of 0.78 μg/mL. The other stereoisomers show negligible or no activity. A sensitive, simple, specific, precise and accurate chiral chromatographic method for the direct analysis of the four stereoisomers of MSDRT 12 and the active Isomer 3 has been developed and validated. The method has also been validated for analysing the stereoisomeric impurities Isomer 1, Isomer 2 and Isomer 4 in the active Isomer 3. The separation of the four stereoisomers of MSDRT 12 was achieved using an immobilized polysaccharide-based column, Chiralpak ID with amylose tris(3-chlorophenylcarbamate) as the chiral selector. The separation was performed using a mixture of n-hexane, isopropyl alcohol, ethanol and diethylamine (60:35:5:0.1 v/v/v/v) at a flow rate of 1 mL/min. The method offers excellent separation of the four stereoisomers with resolution more than 1.5 and tailing factor <1.5. The standard curves were linear over the concentration range 5–500 μg/mL and 0.40–505 μg/mL for MSDRT 12 and Isomer 3, respectively. Excellent linearity in the range 0.4–5 μg/mL was obtained for Isomer 1, Isomer 2 and Isomer 4 and these stereoisomeric impurities could be accurately and precisely quantified at a level of 0.1 % of the active isomer.  相似文献   

19.
Gastrointestinal tract disorders constitute a heavy burden to healthcare providers. To eradicate Helicobacter pylori infection, different triple therapy protocols have been proposed. Among which are combinations of proton pump inhibitors (e.g., omeprazole), histamine-2 receptor antagonists (e.g., famotidine), along with antibiotics (e.g., amoxicillin). In this work, a sensitive and accurate high-performance thin-layer chromatographic method was developed for the simultaneous determination of amoxicillin, metronidazole, and famotidine in bulk powder and laboratory-prepared combined-tablet mixtures. Complete separation of the cited compounds was achieved using pre-coated silica gel plates with a mixture of methanol:chloroform:toluene:water:glacial acetic acid (5:2:1.5:0.5:0.1 v/v/v/v/v) as the mobile phase. The method was fully validated as per the international conference of harmonization guidelines. Good linearity, a correlation coefficient of 0.9991, was obtained in the concentration ranges 0.1–1.6 μg/band (amoxicillin), 0.1–0.9 μg/band (metronidazole), and 0.1–0.9 μg/band (famotidine). Since the method allowed the determination of the three compounds in combined tablets with a high degree of selectivity, accuracy, precision, with cost-effectiveness, it could be used for regular quality control. Moreover, the applicability of the proposed method was extended to the determination of the ternary mixture in simulated gastric juice. Method greenness was assessed using different green metrics.  相似文献   

20.
The present study describes the development and validation of a selective liquid chromatographic (LC) method for the analysis of tenofovir disoproxil fumarate (TDF) and its related substances. The gradient method uses a base deactivated C18 column (Hypersil BDS column; 25 cm×4.6 mm I.D.) maintained at a temperature of 30°C. The mobile phases consist of acetonitrile, tetrabutylammonium/phosphate buffer pH 6.0 and water: (A; 2:20:78 v/v/v) and (B; 65:20:15 v/v/v). The flow rate is 1.0 mL/min and UV detection is performed at 260 nm. Good separation of TDF and 21 impurities was achieved. A system suitability test (SST) to check the quality of separation is also specified. The developed method was further validated with respect to robustness, precision, sensitivity and linearity. The method is proved to be robust, precise, sensitive and linear between 0.1 μg/mL and 0.15 mg/mL. The limit of detection and limit of quantification are 0.03 and 0.1 μg/mL, respectively. The method was successfully applied to the quantification of related substances and assay of commercial TDF samples (bulk substances and tablets).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号