首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
Regadenoson, the first selective adenosine A2A receptor agonist, is used to perform exercise stress test during radionuclide myocardial perfusion imaging. To detect the concentration of regadenoson in human plasma, a simple, fast, and sensitive tandem mass spectrometry method was established herein. Acetonitrile was used as a protein precipitation agent. Chromatographic separation was completed in 6.5 min using a BEH HILIC column (50 × 2.1 mm, 1.7 μm). The mobile phase consisted of 10 mmol/L ammonium acetate/acetonitrile (gradient elution). To quantify regadenoson and regadenoson-d3, an API 4000 mass spectrometry in multiple reaction monitoring mode with transitions of 391.3→259.2 and 394.3→262.2, respectively, was utilized. The calibration curve was linear in the range of 0.100–50.0 μg/L, and the intrabatch and interbatch precisions were <9.7% and <13.0%, respectively, and the accuracy was 2.0–6.9%. There was no apparent matrix effect for regadenoson or regadenoson-d3. The developed method was used to study the pharmacokinetic characteristics of regadenoson in healthy Chinese subjects.  相似文献   

2.
A new method for the fast simultaneous quantification of fluticasone propionate and salmeterol from plasma samples by liquid chromatography–tandem mass spectrometry, with adequate sensitivity for pharmacokinetic applications, was developed and validated. The chromatographic separation and mass‐spectrometric parameters were optimized for the retention and detection of the two compounds, despite quite different structures and properties. Two columns connected in series were used, cation‐exchange (Zorbax 300‐SCX, 5 cm × 2.1 mm, 5 µm) and octadecyl (Discovery HSC18, 10 cm × 2.1 mm, 5 µm). The mass‐spectrometric interface was operated in negative electrospray ionization mode; high sensitivity and lesser matrix effects were obtained, permitting smaller consumption of plasma. The sample preparation was based on supported liquid–liquid extraction in 96‐well format plates that provided clean samples with a simplified procedure that was suitable for automation. The method was validated according to regulatory guidelines, by assessing lower limits of quantification, selectivity, linearity, accuracy, precision, extraction recoveries and matrix effects. A comparison with two other methods for the separate determination of fluticasone propionate and salmeterol in plasma samples, previously developed by our group, is presented. The statistical evaluation of the results obtained with the three methods on a set of unknown samples from treated patients demonstrated good correlation (R2 0.987 for fluticasone propionate and 0.967 for salmeterol). Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
The consumption of food and drugs adulterated with female sex hormones can have an extremely adverse effect on human health. Therefore, developing appropriate monitoring methods for the identification of various exogenous female sex hormones is crucial for minimizing and eliminating the related health risks. Herein, 17 female hormones categorized into two groups: estrogen and progestin, were analyzed using reversed-phase liquid chromatography coupled to Orbitrap or triple quadrupole mass spectrometry. The fragmentation patterns for all compounds were discovered, and fragmented structures were also derived from them through liquid chromatography–high-resolution mass spectrometry followed by qualitative sample analysis. In addition, a quantitative analysis of 67 samples of illicit drugs and dietary supplements was performed using the validated liquid chromatography-tandem mass spectrometry method. Female hormone components were detected in two samples of an unauthorized injectable solution and a tablet-type drug. Medroxyprogesterone was detected in the samples in the range of 96.4–206 ng/g. Notably, eight components similar in structure to steroids were simultaneously detected as male sex hormones by confirming their fragmentation ion patterns using liquid chromatography–high-resolution mass spectrometry. The developed methods thus offer a dependable and practically applicable approach for the screening and detection of exogenous female sex hormones in real food and drug samples to ensure public health.  相似文献   

4.
Liang Y  Wu C  Dai Z  Liang Z  Liang Z  Zhang L  Zhang Y 《色谱》2011,29(6):469-474
微流控芯片高效液相色谱-串联质谱系统具有高通量、高灵敏度等优点,已成为生物样品分析的热点领域之一。本文在玻璃芯片上以甲基丙烯酸十二酯(LMA)和三羟甲基丙烷三甲基丙烯酸酯(TMPTMA)为单体,制备了以聚丙烯酸酯整体材料为固定相的捕集柱和分离柱。通过在芯片通道末端连接细内径的毛细管作为芯片-质谱接口,并以常规的液相色谱泵和微阀控制流体,构建了芯片反相液相色谱-电喷雾串联质谱(RPLC-ESI-MS/MS)平台,并将其用于分析牛血清白蛋白(BSA)的酶解产物。经过3次平行分析,BSA的序列覆盖率分别为39.37%、37.89%和34.10%(相对标准偏差为7.3%)。采用不同批次制作的芯片构建RPLC-ESI-MS/MS平台,对BSA酶解产物进行分析,其序列覆盖率相当。上述结果表明,该平台具有灵敏度高和重现性好等优点,有望用于蛋白质样品的快速分离和高灵敏度鉴定。  相似文献   

5.
The three forms of enterostatin (Ala-Pro-Gly-Pro-Arg, Val-Pro-Gly-Pro-Arg, and Val-Pro-Asp-Pro-Arg), pentapeptides known to inhibit fat-intake, were resolved on a C18 reversed-phase column using a ternary mobile phase consisting of methanol, acetonitrile, and water. Coupled with MS/MS detection, the method has been applied to identify enterostatin sequences in human cerebrospinal fluid and rat brain tissue. Ala-Pro-Gly-Pro-Arg (APGPR) was found to be the predominant enterostatin sequence in both cases. The levels of APGPR were 98.3±16.3 ng/ml in human cerebrospinal fluid and 30.1±12.6 ng/g wet tissue in rat brain, respectively.  相似文献   

6.
Potential of ultra-performance liquid chromatography (UPLC) separation strategy coupled with tandem (in space) mass spectrometric detection (MS/MS) in multiresidue pesticide analysis was critically assessed. Performance parameters such as number of theoretical plates, height of theoretical plate, peak symmetry and peak capacity were measured/calculated on the basis of data generated by analysis of apple extracts containing 17 (semi)polar pesticides representing various classes of active ingredients of widely used crop protective preparations. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) procedure provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to common method employing conventional high-performance liquid chromatography (HPLC) separation.  相似文献   

7.
A rapid and sensitive analytical method based on liquid chromatography coupled to tandem mass spectrometry detection with positive ion electrospray ionization was developed for the determination of febuxostat in human plasma using d7‐febuxostat as the internal standard (IS). A simple protein precipitation was performed using acetonitrile. The analyte and IS were subjected to chromatographic analysis on a Capcell PAK C18 column (4.6 × 100 mm, 5 µm) using acetonitrile–5 mm ammonium acetate–formic acid (85:15:0.015, v/v/v) as the mobile phase at a flow rate of 0.6 mL/min. An Agilent 6460 electrospray tandem mass spectrometer was operated in the multiple reaction monitoring mode. The precursor‐to‐product ion transitions m/z 317 → m/z 261 (febuxsotat) and m/z 324 → m/z (261 + 262) (d7‐febuxostat, IS) were used for quantitation. The results were linear over the studied range (10.0–5000 ng/mL), and the total analysis time for each chromatograph was 3 min. The intra‐ and inter‐day precisions were less than 7.9 and 7.2%, respectively, and the accuracy was within ±4.2%. No evidence of analyte instability in human plasma was observed storage at ?20°C for 31 days. This method was successfully applied in the determination of febuxostat concentrations in plasma samples from healthy Chinese volunteers. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for determining tanshinone IIA in rat tissues. After a single step liquid-liquid extraction with diethyl ether, tanshinone IIA and loratadine (internal standard) was subjected to LC/MS/MS analysis using positive electro-spray ionization under selected reaction monitoring mode. Chromatographic separation of tanshinone IIA and loratadine was achieved on a Hypersil BDS C(18) column (i.d. 2.1 x 50 mm, 5 microm) with a mobile phase consisting of methanol-1% formic acid (90:10, v/v) at a flow rate of 300 microL/min. The intra-day and inter-day precision of the method were less than 10.2 and 12.4%, respectively. The intra-day and inter-day accuracies ranged from 99.7 to 109.7%. The lowest limit of quantification for tanshinone IIA was 1 ng/mL. The method was applied to a tanshinone IIA tissue distribution study after an oral dose of 60 mg/kg to rats. Tanshinone IIA tissue concentrations decreased in the order of stomach > small intestine > lung > liver > fat > muscle > kidneys > spleen > heart > plasma > brain > testes. Tanshinone IIA still could be detected in most of the tissues at 20 h post-dosing. These results indicate that the LC/MS/MS method was rapid and sensitive to quantify tanshinone IIA in different rat tissues.  相似文献   

9.
Saikosaponins (SSs) are a class of triterpene saponins with a wide spectrum of bioactivities. A sensitive liquid chromatography tandem mass spectrometry (LC‐MS/MS) method was developed for simultaneous determination of saikosaponin a, saikosaponin c, saikosaponin d and saikosaponin b2 in rat plasma. Plasma samples were prepared by liquid–liquid extraction. The analytes and the internal standard (IS) digoxin were well separated on an octadecyl column using gradient elution and analyzed by monitoring the fragmentation transition pair of anionic adducts to deprotonated molecules in negative‐mode electrospray. By neutral loss of HCOOH, the transition pairs of m/z 825 → 779 for SSa, SSd, SSb2 and the IS, and m/z 971 → 925 for SSc were sensitive for MS/MS detection with the lower limits of quantification in the range of 0.20–0.40 ng/mL. Method validation experiments were performed, including selectivity, precision, accuracy, linearity, matrix effect, recovery and stability. The validated method was further applied to determine the pharmacokinetics parameters of SSa, c and d in rats following a single oral administration of the extract of chaihu (the dried roots of Bupleurum chinense DC). Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
High-performance liquid chromatography-tandem mass spectrometry coupled with the quick, easy, cheap, effective, rugged and safe method was established for the qualitative and quantitative detections of 20 mycotoxins in milk. The linear range of this method was 0.01–10 μg/L and the correlation coefficients were all greater than or equal to 0.9933. At three levels of addition, the spiked recoveries ranged from 80.00 to 112.50%, relative standard deviations were 2.67–14.97%, limits of quantitation were 0.02–4.00 μg/kg, and limits of detection were 0.007–1.300 μg/kg. This developed procedure for the identification and quantitation of mycotoxins provided prospective support for quality regulation.  相似文献   

11.
建立了大鼠灌胃麻杏石甘汤后血浆中苦杏仁苷、野黑樱苷的定性及定量方法。样品经液液萃取净化处理,定性采用超高效液相色谱-串联四极杆飞行时间质谱仪(UPLC-QTOF-MS/MS),经Shim-pack XR-ODS Ⅲ色谱柱(75 mm×2.0 mm,1.6 μm)分离,定量采用超高效液相色谱-串联三重四极杆质谱仪(UPLC-Q-TRAP-MS),经Agilent C18色谱柱(50 mm×2.1 mm,1.7 μm)分离,电喷雾负离子化(ESI)及MRM模式测定,流动相均为乙腈-0.1%(v/v)甲酸水溶液。结果显示苦杏仁苷、野黑樱苷在相应浓度范围内线性关系良好(相关系数分别为0.9990、0.9970),精密度(RSD)小于9.20%,回收率为82.33%~95.25%,检出限(LOD)约为0.50 ng/mL。本方法快速简便,为血浆样品中苦杏仁苷、野黑樱苷的定性和定量分析提供良好参考。  相似文献   

12.
A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg−1, respectively. This validated method was successfully applied to the determination of melamine in real samples from market.  相似文献   

13.
范广宇  冯峰  张峰  高飞  李晓明  梁振纲 《色谱》2018,36(4):351-355
建立了亲水相互作用色谱-三重四极杆质谱(HILIC-MS/MS)同时测定液体食品中6种人工合成甜味剂和8种甜菊糖苷类天然甜味剂的分析方法。样品经Waters Xbridge Amide色谱柱(150 mm×5.0 mm,3.5 μm)分离,以乙腈-10 mmol/L甲酸铵溶液(65:35,v/v)为流动相,流速为0.4 mL/min,柱温为35℃,然后以电喷雾电离(ESI)源,在多反应监测(MRM)、负离子模式下进行三重四极杆质谱检测。14种甜味剂在各自的范围内线性关系良好,相关系数均大于0.995,检出限为0.03~0.7 mg/kg,定量限为0.1~2.2 mg/kg。在2、5和20 mg/kg添加水平下,14种甜味剂的平均回收率为80.8%~108.7%,相对标准偏差为1.5%~7.7%(n=6)。该方法样品前处理操作简单,准确度高,灵敏度高,可用于液体食品中14种甜味剂的同时测定。  相似文献   

14.
The development and validation of an assay for the determination of paclitaxel in human plasma, human brain tumor tissue, mouse plasma and mouse brain tumor tissue is described. Paclitaxel was extracted from the matrices using liquid-liquid extraction with tert-butyl methyl ether, followed by chromatographic analysis using an alkaline eluent. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicate that calibration standards in human plasma can be used to quantify paclitaxel in all tested matrices. In human samples, the validated range for paclitaxel was from 0.25-1000 ng ml(-1) using 200 microl plasma aliquots and from 5 to 5000 ng g(-1) using 50 microl tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma). In mice, the ranges were 1-1000 ng ml(-1) and 5-5000 ng g(-1) using 50 microl of mouse plasma and 50 microl of tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma), respectively. The method can be applied to studies generating only small sample volumes (e.g. mouse plasma and tumor tissue), but also to studies in human plasma requiring a lower limit of quantitation. The assay was applied successfully to several studies with both human and mouse samples.  相似文献   

15.
N,N–dimethylacetamide is an excipient used in intravenous busulfan formulations, a drug used in hematopoietic stem cell transplantation conditioning. The aim of this study was to develop and validate a liquid chromatography-tandem mass spectrometry method for simultaneous quantification of N,N-dimethylacetamide, and its metabolite N-monomethylacetamide in plasma from children receiving busulfan. A 4 μl aliquot of patient plasma was extracted using 196 μl 50% methanol solution and quantified against calibrators prepared in the extraction solvent given negligible matrix effects across three concentrations. 9[H2]-N,N-dimethylacetamide was used as an internal standard. Separation of N,N-dimethylacetamide and N-monomethylacetamide was achieved using a Kinetex EVO C18 stationary phase (100 mm × 2.1 mm × 2.6 μm) running an isocratic mobile phase of 30% methanol containing 0.1% formic acid at a flow of 0.2 ml/min over 3.0 min. The injection volume was 1 μl. Calibration curves for N,N-dimethylacetamide and N-monomethylacetamide were linear up to 1200 and 200 μg/L, respectively, with a lower limit of quantification 1 μg/L for both analytes. Calibrator accuracy and precision were within ± 10% of the test parameters across four concentration levels. Analytes were stable over 14 days at three different storage conditions. This method was successfully applied to measure N,N-dimethylacetamide and N-monomethylacetamide concentrations in a total of 1265 plasma samples from 77 children.  相似文献   

16.
A proteomics approach was used for the identification of protein binders in historical paints: the proteins were digested enzymatically into peptides using trypsin before being separated and detected by high performance liquid chromatography-electrospray ionisation tandem mass spectrometry (HPLC-ESI-MS/MS). Mascot (Matrix Science) was used to analyse the resulting data and for protein identification. In contrast to amino acid analysis, amino acid sequences could be studied that retain much more information about the proteins. The best extraction strategy was selected based on the number of peptides that were identified in the protein content of paint replicas using different methods. The influence of pigments on the extraction method was studied and the analytical characteristics of the selected method were determined. Finally this method was applied to historical paint microsamples on the anonymous early 15th century panel painting Crucifixion with St Catherine and St Barbara (Calvary of the Tanners), the St Catherine Altarpiece by Joes Beyaert (c. 1479) and two paintings by Pieter Brueghel the Younger (1617-1628).  相似文献   

17.
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid-liquid extraction, the analyte was separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 384 to m/z 221 for quetiapine and m/z 327 to m/z 270 for the internal standard. The assay exhibited a linear dynamic range of 0.25-500 ng/mL for quetiapine in rat plasma. The lower limit of quantification was 0.25 ng/mL with a relative standard deviation of less than 7%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated method was successfully used to analyze rat plasma samples for application in pre-clinical pharmacokinetic studies. This method in rodent plasma could be adapted for quetiapine assay in human plasma.  相似文献   

18.
Sparfloxacin, a fluoroquinolone antibiotic, is used for the treatment of bacterial infection. A quantification method using mass spectrometry was developed for the determination of sparfloxacin in rat plasma. After simple protein precipitation with acetonitrile, the analytes were chromatographed on a reversed‐phase C18 column and detected by liquid chromatography/tandem mass spectrometry with electrospray ionization. The accuracy and precision of the assay were in accordance with FDA regulations for validation of bioanalytical methods. This method was applied to measure the plasma sparfloxacin concentrations after a single oral administration of sparfloxacin in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
向平  沈敏  沈保华  严慧 《色谱》2008,26(4):469-472
采用液相色谱-串联质谱(LC-MS/MS)建立了毛发中司坦唑醇的分析方法,并将其应用于单次给药动物实验中的动物毛样品分析。将10 mg样品碱水解后加入戊烷提取,然后进行LC-MS/MS分析,采用正离子电喷雾电离、多反应监测模式测定,方法的最低定量限为25 pg/mg。剃去豚鼠背部中央的毛,以60 mg/kg的剂量于豚鼠腹腔注射司坦唑醇,然后隔天在同一部位剃取其毛,两周内该豚鼠毛中均能检出司坦唑醇;给药后豚鼠毛中司坦唑醇的含量在第1周内保持稳定,在给药后第10天达到峰值。所建立的方法毛发取样量少,特异性强,灵敏度高,适用于毛发中司坦唑醇的分析。  相似文献   

20.
A multiclass method for the analysis of residues, in egg matrices, of 41 antimicrobial agents belonging to seven families (sulfonamides, diaminopyridine derivates, quinolones, tetracyclines, macrolides, penicillins and lincosamides) was developed and validated according to the requirements of European Commission Decision 2002/657. Compounds were extracted with a pressurized liquid extraction (PLE) technique using a 1:1 mixture of acetonitrile and a succinic acid buffer (pH 6.0) at 70 °C. As this resulted in clear extracts, no further clean-up was necessary. Analytes were determined by ultra-high-pressure liquid chromatography–tandem mass spectrometry (UHPL–MS/MS) in a chromatographic run of 13 min. Calibration was carried out with spiked blank samples subjected to the entire analytical procedure. Five compounds, two of them isotopically labelled, were used as internal standards. Most analytes were quantified with errors below 10%. Precision in terms of reproducibility standard deviation was between 10% and 20% in most cases. CCα values were in the range 0.5–3.8 μg kg−1 for the non-authorized compounds. The proposed method would enable an experienced analyst to process about 25 samples per day.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号