首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Secondary ion emission has been investigated for Ti, V, Cr and for Co, Ni and Cu under 9 mPa of NO as reactant gas with dynamic SIMS conditions. Using pivoted targets the relative intensities of various positive secondary ions were measured for varied incidence angles of the primary Ar+ ions (2 keV; 32 A·cm–2). The axis of the PI beam and the axis of the SI detector were fixed rectangular to each other. The targets could be rotated about an axis perpendicular to both the PI and the detector axis. From the directional change of the emission of the metal ions Me+ a geometric shift parameter Ps could be deduced which proved to be related to the relative secondary ion yield and may therefore be used for surface characterization.  相似文献   

2.
Summary The high activity of the radionuclides 65Ni (t1/2=2.52 h) and 58Co (t1/2=70.8 d) imposes severe limitations on the performance of direct instrumental neutron activation analysis of nickel. The extent of the interference of the 58Co depends on the ratio of the fluxes of the fast and thermal neutrons. A method of selective removal of cobalt, based on extraction with -nitroso--naphthol has been developed for the purpose of radiochemical NAA. Separation yields have been determined for 36 elements. The detection limits obtainable with both the instrumental and the radiochemical method are <10–4 g/g for the elements Au, Eu, Ir, La, Sc and Sm, between 10–4 and 10–3 g/g for Cr, Cs, Hf, Hg, Lu, Re, Sb, Ta, Th, Tm and Yb, between 10–3 and 10–2 g/g for As, Ag, Br, Ce, Ga, Na, Ru, Se, W and Zn, and in the range 0.01–1 g/g for Ba, Cd, Co, Fe, In, K, Mo, Nd, Pd, Rb, Sn, U and Zr.  相似文献   

3.
The discharge of thin films of Li x V2O5 is described by a mathematical diffusion model. The chemical diffusion coefficient for lithium ions, estimated with the model, is equal to (1.01–2.5) × 10–11 cm2/s. As the film thickness increases, the discharge capacity at a current of 20 A/cm2 tends to the calculated limiting of 3.12 C/cm2. The optimum thickness of the film electrode calculated for a discharge current of 20 A/cm2 is 33.4 m and agrees satisfactorily with the experimental value.  相似文献   

4.
Summary Very few biological reference materials are certified for nickel below 1 mg · kg–1. Neutron activation analysis was only rarely considered as a possible approach; reported sensitivities were usually not very good, unless preconcentration was applied.In the present work, the relatively high fast neutron flux of our TRIGA reactor was used to induce the 58Ni(n, p)58Co reaction, and 58Co (E =811 keV) was radiochemically separated from other radionuclides by classical anion-exchange chromatography in hydrochloric acid. 57Co was added to the irradiated sample before decomposition as a radioisotopic yield monitor. By concentrating the final sample fraction and measurement in a well-type HP Ge detector, Ni concentrations down to the 10-g · kg–1 level could be determined for samples irradiated for 1 day. 60Co, produced by neutron capture on 59Co, is also coseparated and quantified from the gamma spectrum, so that both elements Ni and Co are determined. Results are reported for a series of NBS and other biological reference materials in the concentration range 10 g-10 mg · kg–1. Possibilities for further increases in sensitivity are discussed.
Spurenbestimmung von Nickel (und Cobalt) in biologischen Referenzmaterialien durch radiochemische Neutronenaktivierungsanalyse
  相似文献   

5.
Summary Investigations on the polarographic and voltammetric behaviour of organic halogen compounds were carried out in order to obtain information on the redox properties and how to develop determination and detection methods. In this second report the dp-polarographic behaviour of the halogen substituted C2-compounds has been studied in different supporting electrolytes and in various solvents. The electrode processes are discussed and the possibilities for the polarographic determination of the C2-halogen hydrocarbons. The detection limit is 0.25 g · ml–1 and the linear current-concentration relationship is observed up to 25 g · ml–1. A simple and rapid method is proposed for the dp-polarographic determination of 1,2-dibromoethane in gasoline; the relative standard deviation for 20 g · ml–1 is ±1.8%.  相似文献   

6.
Summary Use of HMPA in Co(II) thiocyanate colour system gives a simple, sensitive and selective method for the determination of Co(II). Maximum colour intensity is attained in the acidity range of 0.15–0.75M HCl and thiocyanate concentration of 0.5–1.0M. The colour is completely extractable into chloroform, when 2 to 4 ml HMPA is used. The colour system shows maximum absorption at 610 nm. The Beer's law range is 2 to 52g Co/ml with optimum concentration range of 6–48g Co/ml. The molar absorptivity and sensitivity are 1.24 x 103 l·mole–1·cm–1 and 0.047g Co/cm2 respectively. The method has been applied to the determination of cobalt in steel.
Flüssig-flüssig-Extraktion von Kobalt(II)thiocyanat mit Hexamethylpbos-phoramid (HMPA) und spektrophotometrische Bestimmung in der organischen Phase
Zusammenfassung Auf der Grundlage der Farbreaktion von Kobalt(II)thiocyanat mit HMPA wurde eine einfache, empfindliche und selektive Methode zur Bestimmung von Co(II) entwickelt. Das Farbmaximum erhält man in 0,15–0,75M salzsaurer Lösung bei 0,5–1,0M Thiocyanat-Konzentration. Die Färbung ist mit Chloroform vollständig extrahierbar, wenn 2—4 ml HMPA verwendet werden. Die maximale Absorption liegt bei 610 nm. Der optimale Konzentrationsbereich liegt zwischen 6 und 48g Co/ml. Die molare Absorption beträgt 1,24 x l03l·mole–1·cm–1, die Empfindlichkeit 0,047g Co/cm2. Die Methode wurde zur Bestimmung von Kobalt in Stahl verwendet.
  相似文献   

7.
Instrumental neutron activation analysis (INAA) technique has been employed viak 0 approximation method to determine elemental composition of five shaving powders commonly marketed in Nigeria. Fe displayed the highest concentrations in the range 1000–2000 g·g–1. Na and Zn concentrations were established in the range 200–400 g·g–1. Heavy elements like Ga, La, Cr, Co, Ag, Ce and Nd concentrations were noted in the lower range of 1–10 g·g–1 Br, As, Sb, Sm, Eu, W, Cs, Tb, Yb, Hf, Ta, Th and U concentrations were established in even lower traces in the <1 g·g–1 range. Results obtained for a certified reference material, CANMET BL-1 and CERT (in house) Kaolin standard compared favourably with the literature values thus establishing the results presented for the shaving powders.  相似文献   

8.
We have studied the feasibility of producing57Co (271.3 d) via the55Mn(, 2n)57Co reaction (55Mn–100%). The thick target yield of57Co in the 28 to 18 MeV energy region was measured as 3.87 Ci/Ah. However, the proximity and overlap of the excitation functions for (, n), (, 2n) and (, 3n) reactions on55Mn are such that the production of pure57Co in high yields free of58Co (70.8 d) and56Co (78.8 d) has not been feasible. We have also studied a new method for ancillary production of57Co via the reactions58Ni(, p)57Co and during the course of producing62Zn by60Ni(, 2n)62Zn reaction. In this case the yield of57Co of reasonable purity has been up to 1 Ci/Ah.  相似文献   

9.
Relatively longer liver technetium tracers such as95mTc (61 d) are useful for the development, evaluation and comparison of new technetium complexes for eventual development of99mTc radiopharmaceuticals. The feasibility of producing96Tc (4.35 d) and95mTc (61 d) was studied by the alpha bombardment of pure Nb targets (93Nb-100%).96Tc was obtained in a yield of 30 Ci/Ah using 16 MeV alphas, but it contained significant activity of95Tc (20 h) Relatively pure96Tc and95mTc was produced in yields of 18 Ci/Ah and about 1 Ci/Ah respectively with alphas of suitable energy and after allowing for suitable cooling periods after the end of bombardment (EOB).  相似文献   

10.
The determination of uranium in liquid samples using energy dispersive X-ray fluorescence was investigated. The organic phase di-(2-ethyl hexyl) phosphoric acid and trioctyl phosphine oxide (D2EHPA-TOPO)/kerosene, which resulted from first and second cycles of uranium extraction from commercial phosphoric acid, was directly analyzed using 109Cd as a primary excitation source. Copper was used as an internal standard, which led to a linear relation between relative intensity of uranium and its concentration. Three calibration curves, 0–100, 100–1000 and 1000–6500 g· ml–1, according to uranium concentration in the studied samples, were constructed. The effect of different molarities of D2EHPA and TOPO was considered. The detection limit, precision and accuracy were 1.1 g · ml–1, 3% and 1.4%, respectively. The obtained results were compared with other techniques such as -ray spectroscopy, UV spectrometry and volumetry.  相似文献   

11.
Packed-column supercritical-fluid chromatography (pSFC) is presented as a novel method for separating and analyzing gramicidin samples. By use of methanol-modified carbon dioxide as a mobile phase the pentadecapeptides gramicidin A (gA), gramicidin B (gB), and gramicidin C (gC) are readily separated and eluted from a PRP-1 poly(styrene–divinylbenzene) column. Although optimum separation conditions are typically achieved near a column temperature of 40°C, a column pressure of 11 MPa, and 30% methanol modifier, pressure and modifier gradients around these values are also found to improve the overall separation time. Measurements indicate that the mobile phase solubility of gramicidin under these conditions is 5.0±0.4 g mL–1. Collection of individual peaks during chromatography achieved analytical-scale isolation of 2 g refined gC from 20 g injected gramicidin D. Further, supercritical-fluid extraction of 200 g gramicidin D from a Chromosorb 102 support packed into the vessel produced 57 g gA in 90% purity. The results establish that carbon dioxide-based mobile phases can be successfully used for the separation of individual gramicidin species.  相似文献   

12.
In a long-term field study at two locations with different air pollution levels several soot-selective measurement techniques were compared with a thermochemical method which measures non-extractable carbon (NEC) detecting the evolved CO2 by means of coulometric titration. The attenuation measurement technique (aethalometer) and the aerosol photoemission method showed good correlations to NEC for concentrations ranging from 1.6g/m3 to 40.8g/m3. The specific mass absorption coefficient of black carbon with respect to NEC varied between 8.4m2/g and 13.7m2/g with respect to the measurement sites, but the value was found to remain constant at each site independent of seasonal or meteorological variations. The ratio of photoelectric signal to NEC varied between 16 fA·(g/m3)–1 and 33 fA·(g/m3)–1 depending on the age of the aerosol. The diurnal variations of that ratio showed strong similarities to the traffic patterns. Additionally a slight temperature dependence of this ratio was found for the aged aerosol with a proportionality factor of – 0.35 fA·(K·g/m3)–1. With the reflectance measurement technique (smoke shade method) reliable NEC determination was not possible for NEC concentrations 5 g/m3.  相似文献   

13.
Summary A gas chromatographic methodology with selective detection is presented for the analysis in wines and corks of pentachlorophenol residues, which are suspected to be the most likely precursors of some off-flavours described in several wine samples. After derivatisation, pentachlorophenol acetate residues were monitored by electrolytic conductivity detection and/or mass spectrometric detection in the selective ion mode at m/z 264 and 266. Recoveries varied from 80 to 96% for wine samples fortified with 5 to 100 g l–1 and from 83 to 91% for corks (fortified at 25 to 100 g kg–1). The proposed methodology allowed for a determination limit of g l–1 for wine and 10 g kg–1 for corks.  相似文献   

14.
Summary Chrome Azurol S permits a simple colorimetric determination of palladium with a sensitivity of 0.4g/cm2 (practical) or 0.04g/cm2 (Sandell), respectively. Conditions and interferences are described in detail.
Zusammenfassung Palladium läßt sich mit Hilfe von Chromazurol S auf einfache Weise kolorimetrisch bestimmen. Die praktische Empfindlichkeit der Methode beträgt 0,4g/cm2 bzw. 0,04g/cm2 nachSandell. Die Arbeitsbedingungen und die durch Fremdionen verursachten Störungen werden angegeben.

Résumé Le chromazurol S permet un dosage colorimétrique simple du palladium, avec une sensibilité de 0,4g/cm2 (en pratique) ou 0,04g/cm2 (Sandell) respectivement. On décrit en détail les conditions opératoires et les interférences.
  相似文献   

15.
The determination of the trace metals Cd, Pb and Cu in seawater by electrothermal atomic absorption spectrometry (ETA-AAS) has been investigated. A combination of the platform with mixed palladium nitrate-magnesium nitrate as matrix modifier and Zeeman background correction allows Cd an Pb to be determined by aqueous standard calibration in appropriately diluted seawater samples. Copper can be determined in undiluted seawater samples without chemical modification using a standard additions method. Detection limits (3) of 2.97,5.27 and 1.1 gl–1 are obtained for Cd, Pb and Cu respectively. A Kelex-100 impregnated silica C18 material (Kelex 100-C18) has been tried and has proved to be effective as a column packing for extraction/preconcentration of these metals from seawater. Using the column extraction method, the sensitivity of the graphite furnace technique is enhanced 50-fold using a 10 l injection volume. Thus, the determination of the studied three metals in seawater at the ng.l–1 level could be achieved.  相似文献   

16.
The optimum conditions for the extractive spectrophotometric determination of dioxouranium(VI) with hexamethyleneiminecarbodithioate(HMICdt) have been established. Dioxouranium(VI) reacts with this ligand at pH 4.5 to form a yellowish-orange uncharged 12 metal-ligand complex which can be extracted by chloroform. The calibration graph was linear in the range of 1–20 g ml–1 of dioxouranium(VI) at 335 nm. The molar absorptivity of the extracted species is 5.952×103 l mol–1 cm–1 with Sandell's sensitivity of 0.04 g cm–2. The average of 10 determinations of dioxouranium was 49.75 g for the samples containing 50 g of U(VI) and the variation from the mean at 95% confidence limit was 49.75±0.5955.  相似文献   

17.
Methods are described for the determination of trace and ultra trace amounts of Cd, Co, Cr, Cu, Fe, Mn, Ni and Pb in natural waters, alkali and alkaline earth salts. Separation and preconcentration of trace metals is achieved by a column solid phase extraction procedure using silica gel modified with derivatives of dithiocarbamates — Na-DDTC (sodium diethyldithio-carbamate and HMDTC (ammonium hexamethylene-dithiocarbamate) as column packing material. The influence of the sorbent preparation procedure on the degree of sorption of the trace analytes is examined for different pH values of the sample solution. Isobutylmethyl ketone (IBMK) is proposed as an effective eluent for quantitative elution of retained metal ions. Optimal instrumental parameters for ETAAS determination of preconcentrated elements in organic eluate are presented. Practical application of sorbents in analysis of natural waters and alkali and alkaline earth salts is demonstrated. Proposed preconcentration procedure combined with ETAAS determination of trace analytes allows the determination of 0.04 g l–1 Cd, 0.1 g l–1 Cr, Cu, and Mn and 0.3 g l–1 Co, Fe, Ni and Pb in natural waters and 1.10–7% Cd, 3.10–7% Cr and Mn, 7.10–7% Co, Ni and Pb and 2.10–6% Cu and Fe in alkali and alkaline earth salts.  相似文献   

18.
Summary A method for the isotope dilution mass spectrometric (IDMS) determination of boron in rye grass at the 5 g · g–1 level has been developed. The mass spectrometric measurements are performed using negative thermal ionization at masses 42 (10B16O16O) and 43 (11B16O16O). The 10B/11B ratios are corrected for the 10B16O17O contribution at mass 43 and for mass fractionation. The chemical blank is determined using the standard addition method. The numerical calculations are done with a least square fit computer program. The method has been applied for the certification of boron in BCR 281 (Rye Grass). The boron content of this reference material has been established as (5.64±0.56) g·g–1.
Bestimmung von Borspuren in Rye Grass BCR 281 durch Isotopenverdünnungs-Massenspektrometrie
  相似文献   

19.
Twenty-one ready-to-use hobby glazes, of which 18 were labeled safe for food containers (SFFC), were analyzed for Al, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, Gd, Hf, K, Mn, Na, Pb, Si, Sm, Sr, Ti, Zn, and Zr by neutron capture prompt -ray activation analysis (PGAA). Simultaneously, Pb was also determined by X-ray fluorescence spectrometry (XRFS) using Pb K X-rays induced by the -ray component of the neutron beam. The XRFS limits of detection were 200–400 g Pb·g–1 (dry weight), a factor of 100 better than those for PGAA. Pb concentrations (by dry weight; with weight losses ranging from 28 to 49% after air-drying) found were 0.16–27.2% in the SFFC glazes and 0.86–32% in the other glazes. The SFFC glazes contained from <0.6 to 202 g Cd·g–1, and Co, Cr, and Cu (elements which may enhance Pb leaching from fired glazes) were found in concentrations up to 1.2, 2.7, and 5.6%, respectively. Method accuracy was demonstrated with the analysis of soil, fly ash, and glass standard reference materials.  相似文献   

20.
Cyclic voltammetry and galvanostatic coulometry techniques were used to determine how the redox properties of osmium binuclear -oxocarboxylates [Os2 IV(-O)(-O2CR)2Cl4L2] (R = CH3, CCl3; L = PPh3 and R = CH3; L = AsPh3) are influenced by the nature of the bridging carboxylate ligand RCOO and ligand L. It was shown that all compounds in solution of dichloromethane undergo two single-electron reduction processes. The data obtained were compared with the DFT calculations of the electronic structure of the model complexes [Os2 IV(-O)(-O2CR)2Cl4L2] (R = CH3, CCl3; L = PH3 and R = CH3; L = AsH3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号