首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
To better represent fine structure cues in cochlear implants (CIs), recent research has proposed varying the stimulation rate based on slowly varying frequency modulation (FM) information. The present study investigated the abilities of CI users to detect FM with simultaneous amplitude modulation (AM). FM detection thresholds (FMDTs) for 10-Hz sinusoidal FM and upward frequency sweeps were measured as a function of standard frequency (75-1000 Hz). Three AM conditions were tested, including (1) No AM, (2) 20-Hz Sinusoidal AM (SAM) with modulation depths of 10%, 20%, or 30%, and (3) Noise AM (NAM), in which the amplitude was randomly and uniformly varied over a range of 1, 2, or 3 dB, relative to the reference amplitude. Results showed that FMDTs worsened with increasing standard frequencies, and were lower for sinusoidal FM than for upward frequency sweeps. Simultaneous AM significantly interfered with FM detection; FMDTs were significantly poorer with simultaneous NAM than with SAM. Besides, sinusoidal FMDTs significantly worsened when the starting phase of simultaneous SAM was randomized. These results suggest that FM and AM in CI partly share a common loudness-based coding mechanism and the feasibility of "FM+AM" strategies for CI speech processing may be limited.  相似文献   

2.
The goals of the present study were to measure acoustic temporal modulation transfer functions (TMTFs) in cochlear implant listeners and examine the relationship between modulation detection and speech recognition abilities. The effects of automatic gain control, presentation level and number of channels on modulation detection thresholds (MDTs) were examined using the listeners' clinical sound processor. The general form of the TMTF was low-pass, consistent with previous studies. The operation of automatic gain control had no effect on MDTs when the stimuli were presented at 65 dBA. MDTs were not dependent on the presentation levels (ranging from 50 to 75 dBA) nor on the number of channels. Significant correlations were found between MDTs and speech recognition scores. The rates of decay of the TMTFs were predictive of speech recognition abilities. Spectral-ripple discrimination was evaluated to examine the relationship between temporal and spectral envelope sensitivities. No correlations were found between the two measures, and 56% of the variance in speech recognition was predicted jointly by the two tasks. The present study suggests that temporal modulation detection measured with the sound processor can serve as a useful measure of the ability of clinical sound processing strategies to deliver clinically pertinent temporal information.  相似文献   

3.
The efficacy of cochlear implants is limited by spatial and temporal interactions among channels. This study explores the spatially restricted tripolar electrode configuration and compares it to bipolar and monopolar stimulation. Measures of threshold and channel interaction were obtained from nine subjects implanted with the Clarion HiFocus-I electrode array. Stimuli were biphasic pulses delivered at 1020 pulses/s. Threshold increased from monopolar to bipolar to tripolar stimulation and was most variable across channels with the tripolar configuration. Channel interaction, quantified by the shift in threshold between single- and two-channel stimulation, occurred for all three configurations but was largest for the monopolar and simultaneous conditions. The threshold shifts with simultaneous tripolar stimulation were slightly smaller than with bipolar and were not as strongly affected by the timing of the two channel stimulation as was monopolar. The subjects' performances on clinical speech tests were correlated with channel-to-channel variability in tripolar threshold, such that greater variability was related to poorer performance. The data suggest that tripolar channels with high thresholds may reveal cochlear regions of low neuron survival or poor electrode placement.  相似文献   

4.
Envelope detection and processing are very important for cochlear implant (CI) listeners, who must rely on obtaining significant amounts of acoustic information from the time-varying envelopes of stimuli. In previous work, Chatterjee and Robert [JARO 2(2), 159-171 (2001)] reported on a stochastic-resonance-type effect in modulation detection by CI listeners: optimum levels of noise in the envelope enhanced modulation detection under certain conditions, particularly when the carrier level was low. The results of that study suggested that a low carrier level was sufficient to evoke the observed stochastic resonance effect, but did not clarify whether a low carrier level was necessary to evoke the effect. Modulation thresholds in CI listeners generally decrease with increasing carrier level. The experiments in this study were designed to investigate whether the observed noise-induced enhancement is related to the low carrier level per se, or to the poor modulation sensitivity that accompanies it. This was done by keeping the carrier amplitude fixed at a moderate level and increasing modulation frequency so that modulation sensitivity could be reduced without lowering carrier level. The results suggest that modulation sensitivity, not carrier level, is the primary factor determining the effect of the noise.  相似文献   

5.
Loudness estimates were obtained in a group of four adult subjects implanted with the Nucleus-22 multielectrode cochlear implant device, for a range of pulse amplitudes and different fixed phase durations and electrode separations. The stimulus was a 200-ms long train of biphasic pulses presented at 500 pulses/s. Subjects estimated loudness as a number from 0 ("don't hear it") to 100 ("uncomfortably loud"). Loudness was found to grow exponentially with pulse amplitude, at a rate that was dependent upon the phase duration as well as the electrode separation. An equation of the form L = e(lambda + gamma M)(D theta)I, where L is the estimated loudness, M is the separation between electrodes of a stimulating pair, D is the phase duration, I is current amplitude, and lambda, gamma, and theta are constants, appears to describe the observed data adequately. The findings are remarkably consistent across subjects.  相似文献   

6.
This study examined within- and across-electrode-channel processing of temporal gaps in successful users of MED-EL COMBI 40+ cochlear implants. The first experiment tested across-ear gap duration discrimination (GDD) in four listeners with bilateral implants. The results demonstrated that across-ear GDD thresholds are elevated relative to monaural, within-electrode-channel thresholds; the size of the threshold shift was approximately the same as for monaural, across-electrode-channel configurations. Experiment 1 also demonstrated a decline in GDD performance for channel-asymmetric markers. The second experiment tested the effect of envelope fluctuation on gap detection (GD) for monaural markers carried on a single electrode channel. Results from five cochlear implant listeners indicated that envelopes associated with 50-Hz wide bands of noise resulted in poorer GD thresholds than envelopes associated with 300-Hz wide bands of noise. In both cases GD thresholds improved when envelope fluctuations were compressed by an exponent of 0.2. The results of both experiments parallel those found for acoustic hearing, therefore suggesting that temporal processing of gaps is largely limited by factors central to the cochlea.  相似文献   

7.
Most modern cochlear-implant speech processors convey speech-envelope information using amplitude-modulated pulse trains. The use of higher-rate carrier pulse trains allows more envelope detail in the signal. However, neural response properties could limit the efficacy of high-rate carriers. This study examined effects of carrier rate and stimulation site, on psychophysical modulation detection thresholds (MDTs). Both of these variables could affect the neural representation of the carrier and thus affect perception of the modulation. Twelve human subjects with cochlear implants were tested. Phase duration of symmetric biphasic pulses was modulated sinusoidally at 40 Hz. MDTs were determined for monopolar stimulation at two carrier rates [250 and 4000 pulses/s (pps)], three stimulation sites (basal, middle, and apical), and five stimulus levels (10%, 30%, 50%, 70%, and 90% of the dynamic range). MDTs were lower for 250 pps carriers than for 4000 pps carriers in 71% of the 180 cases studied. Effects of carrier rate were greatest at the apical stimulation site and effects of stimulation site on MDTs depended on carrier rate. The data suggest a distinct disadvantage to using carrier pulse rates as high as 4000 pps. Stimulation site should be considered in evaluating modulation detection ability.  相似文献   

8.
In a single interval task, multichannel cochlear implant patients were asked to identify the members of a set of seven electric stimuli differing in electric pulse rate or electrode position. The perceptual sensitivity index (d') between successive stimuli in a stimulus set was calculated from the confusions among the seven stimuli. The results showed that the pulse rate above which the identification task became difficult varied from 200 to 600 pps from patient to patient. For the identification of the positions of seven bipolar electrode pairs, d' measures for stimulus sets differing in spatial separation or spatial extent were compared. Spatial separation is defined as the fixed distance between the two basal (or apical) electrodes of two successive bipolar electrode pairs in a stimulus set, while spatial extent is defined as the fixed distance between the apical and basal electrodes of each bipolar electrode pair in a stimulus set. The results showed that perceptual performance improved in an orderly way with spatial separation, but was not significantly affected by spatial extent.  相似文献   

9.
In modern cochlear implants, much of the information required for recognition of important sounds is conveyed by temporal modulation of the charge per phase in interleaved trains of electrical pulses. In this study, modulation detection thresholds (MDTs) were used to assess listeners' abilities to detect sinusoidal modulation of charge per phase at each available stimulation site in their 22-electrode implants. Fourteen subjects were tested. MDTs were found to be highly variable across stimulation sites in most listeners. The across-site patterns of MDTs differed considerably from subject to subject. The subject-specific patterns of across-site variability of MDTs suggest that peripheral site-specific characteristics, such as electrode placement and the number and condition of surviving neurons, play a primary role in determining modulation sensitivity. Across-site patterns of detection thresholds (T levels), maximum comfortable loudness levels (C levels) and dynamic ranges (DRs) were not consistently correlated with across-site patterns of MDTs within subjects, indicating that the mechanisms underlying across-site variation in these measures differed from those underlying across-site variation in MDTs. MDTs sampled from multiple sites in a listener's electrode array might be useful for diagnosing across-subject differences in speech recognition with cochlear implants and for guiding strategies to improve the individual's perception.  相似文献   

10.
Cochlear implant (CI) users' speech understanding may be influenced by different speaking styles. In this study, speech recognition was measured in Mandarin-speaking CI and normal-hearing (NH) subjects for sentences produced according to four styles: slow, normal, fast, and whispered. CI subjects were tested using their clinical processors; NH subjects were tested while listening to a four-channel CI simulation. Performance gradually worsened with increasing speaking rate and was much poorer with whispered speech. CI performance was generally similar to NH performance with the four-channel simulation. Results suggest that some speaking styles, especially whispering, may negatively affect Mandarin-speaking CI users' speech understanding.  相似文献   

11.
Two experiments investigated the impact of reverberation and masking on speech understanding using cochlear implant (CI) simulations. Experiment 1 tested sentence recognition in quiet. Stimuli were processed with reverberation simulation (T=0.425, 0.266, 0.152, and 0.0 s) and then either processed with vocoding (6, 12, or 24 channels) or were subjected to no further processing. Reverberation alone had only a small impact on perception when as few as 12 channels of information were available. However, when the processing was limited to 6 channels, perception was extremely vulnerable to the effects of reverberation. In experiment 2, subjects listened to reverberated sentences, through 6- and 12-channel processors, in the presence of either speech-spectrum noise (SSN) or two-talker babble (TTB) at various target-to-masker ratios. The combined impact of reverberation and masking was profound, although there was no interaction between the two effects. This differs from results obtained in subjects listening to unprocessed speech where interactions between reverberation and masking have been shown to exist. A speech transmission index (STI) analysis indicated a reasonably good prediction of speech recognition performance. Unlike previous investigations, the SSN and TTB maskers produced equivalent results, raising questions about the role of informational masking in CI processed speech.  相似文献   

12.
The primary goal of this study was to examine the relation between electrophysiologic measures of channel interaction and the ability to discriminate pitch between electrodes in a psychophysical pitch-ranking task. It was hypothesized that cochlear implant recipients should perform better on an electrode pitch-ranking task when using electrodes with less channel interaction as measured with the electrically evoked compound action potential (ECAP). The width of the ECAP channel interaction function was compared with the slope of the pitch-ranking function for 10 adult Nucleus 24 recipients. Results showed no significant correlation between electrode pitch-ranking ability and width of the ECAP channel interaction function for individual subjects or for group data. Additionally, there was no significant correlation between speech perception performance and either pitch-ranking ability or width of the ECAP channel interaction function. These results suggest that the width of the ECAP interaction function may not be an accurate predictor of the ability to discriminate between electrodes on the basis of pitch.  相似文献   

13.
Behavioral and acoustic reflex thresholds were determined for five normal-hearing subjects in response to carrier signals of 500 and 2000 Hz which were unmodulated or modulated sinusoidally at rates of 2, 20, and 200 times per second with frequency deviations (delta f) of 30, 100, and 300 Hz. Behavioral (absolute and masked) thresholds were determined using an adaptive two-alternative forced-choice procedure. Acoustic reflex thresholds were determined by visual inspection of stored reflex waveforms. Frequency modulation was not found to exert a systematic effect at absolute threshold. Frequency modulation did affect threshold estimates systematically, but differentially, at masked threshold and acoustic reflex threshold. Increasing the frequency deviation of the modulation was associated with an increase in masked threshold and with a decrease in acoustic reflex threshold at both test frequencies. The findings are discussed in terms of critical band phenomena.  相似文献   

14.
Experiments were conducted with a single, bilateral cochlear implant user to examine interaural level and time-delay cues that putatively underlie the design and efficacy of bilateral implant systems. The subject's two implants were of different types but custom equipment allowed presentation of controlled bilateral stimuli, particularly those with specified interaural time difference (ITD) and interaural level difference (ILD) cues. A lateralization task was used to measure the effect of these cues on the perceived location of the sensations elicited. For trains of fixed-amplitude, biphasic current pulses at 100 pps, the subject demonstrated sensitivity to an ITD of 300 micros, providing evidence of access to binaural information. The choice of bilateral electrode pair greatly influenced ITD sensitivity, suggesting that electrode pairings are likely to be an important consideration in the effort to provide binaural advantages. The selection of bilateral electrode pairs showing sensitivity to ITD was partially aided by comparisons of the pitch elicited by individual electrodes in each ear (when stimulated alone with fixed-amplitude current pulses at 813 pps): specifically, interaural electrodes with similar pitches were more likely (but not certain) to show ITD sensitivity. Significant changes in lateral position occurred with specific electrode pairs. With five bilateral electrode pairs of 14 tested, ITDs of 300 and 600 micros moved an auditory image significantly from right to left. With these same pairs, ILD changes of approximately 11% of the dynamic range (in microApp) moved an auditory image from the far left to the far right-significantly farther than the nine pairs not showing significant ITD sensitivity. However, even these nine pairs did show response changes as a function of the interaural (or confounding monaural) level cue. Overall, insofar as the access to bilateral cues demonstrated herein generalizes to other subjects, it provides hope that the normal binaural advantages for speech recognition and sound localization can be made available to bilateral implant users.  相似文献   

15.
The primary goal of this study was to examine electrophysiologic measures of channel interaction, electrode pitch discrimination ability using a pitch-ranking task, and behavioral threshold levels in individuals implanted with a straight electrode array versus a perimodiolar array. It was hypothesized that perimodiolar arrays should yield lower thresholds, less channel interaction as measured with the electrically evoked compound action potential (ECAP), and better electrode pitch-ranking ability. Results from ten adult Nucleus 24 recipients (N=5 straight array, N=5 perimodiolar Contour array) showed no significant difference in threshold between the two electrode designs; however, there was significantly better electrode pitch-ranking ability and less channel interaction as measured with the ECAP for perimodiolar electrodes. Additionally, there was a significant positive correlation between behavioral threshold and width of the ECAP interaction function for Contour group data. There was no significant correlation between behavioral threshold and electrode pitch-ranking ability. These data suggest that electrode design and/or perimodiolar position may reduce physiologic channel interaction in the cochlea and improve electrode pitch discrimination ability; however, this positive finding did not translate into significantly better speech perception ability for Contour subjects.  相似文献   

16.
Gap detection as a measure of electrode interaction in cochlear implants.   总被引:1,自引:0,他引:1  
Gap detection thresholds were measured as an indication of the amount of interaction between electrodes in a cochlear implant. The hypothesis in this study was as follows: when the two stimuli that bound the gap stimulate the same electrode, and thus the same neural population, the gap detection threshold will be short. As two stimuli are presented to two electrodes that are more widely separated, the amount of neural overlap of the two stimuli decreases, the stimuli sound more dissimilar, and the gap thresholds increase. Gap detection thresholds can thus be used to infer the amount of overlap in neural populations stimulated by two electrodes. Three users of the Nucleus cochlear implant participated in this study. Gap detection thresholds were measured as a function of the distance between the two electrode pairs and as a function of the spacing between the two electrodes of a bipolar pair (i.e., using different modes of stimulation). The results indicate that measuring gap detection thresholds may provide an estimate of the amount of electrode interaction. Gap detection thresholds were a function of the physical separation of the electrode pairs used for the two stimuli that bound the gap. Lower gap thresholds were observed when the two electrode pairs were closely spaced, and gap thresholds increased as the separation increased, resulting in a "psychophysical tuning curve" as a function of electrode separation. The sharpness of tuning varied across subjects, and for the three subjects in this study, the tuning was generally sharper for the subjects with better speech recognition. The data also indicate that increasing the separation between active and reference electrodes has limited effect on spatial selectivity (or tuning) as measured perceptually.  相似文献   

17.
Speech perception studies were conducted on three cochlear implant patients to investigate the relative merits of six speech processing schemes for presenting speech information to these patients. Electrical stimuli, described in this article as synthetic vowels, were constructed using tabulated data of formant frequencies of natural vowels. The six schemes differed in the number of formant frequencies encoded on the electrical signal dimension of electrode position, and/or in the range of electrode position used for encoding each formant frequency. Eleven synthetic vowels (i, I, E, ae, a, c, U, u, v, E, D) were used and were presented in a single-interval procedure for absolute identification. Single-formant vowels were used in two of the six schemes, two-formant vowels in three schemes, and three-formant vowels in the remaining scheme. The confusion matrices were subjected to conditional information transmission analysis on the basis of previous psychophysiological findings. Comparisons among the schemes in terms of the analyzed results showed that training, experience, and adaptability to new speech processing schemes were major factors influencing the identification of synthetic vowels. For vowels containing more than one formant, the information about each formant affected the perception of the other formants. In addition, there appeared to be differences between the perceptual processes for vowels containing more than one formant and the processes for single-formant vowels. Taking into consideration the effects of training, experience, and adaptability, the three-formant speech processing scheme appeared, on the basis of perceptual performance comparisons among the six schemes, to be the logical choice for implementation in speech processors for cochlear implant patients.  相似文献   

18.
Speech perception in the presence of another competing voice is one of the most challenging tasks for cochlear implant users. Several studies have shown that (1) the fundamental frequency (F0) is a useful cue for segregating competing speech sounds and (2) the F0 is better represented by the temporal fine structure than by the temporal envelope. However, current cochlear implant speech processing algorithms emphasize temporal envelope information and discard the temporal fine structure. In this study, speech recognition was measured as a function of the F0 separation of the target and competing sentence in normal-hearing and cochlear implant listeners. For the normal-hearing listeners, the combined sentences were processed through either a standard implant simulation or a new algorithm which additionally extracts a slowed-down version of the temporal fine structure (called Frequency-Amplitude-Modulation-Encoding). The results showed no benefit of increasing F0 separation for the cochlear implant or simulation groups. In contrast, the new algorithm resulted in gradual improvements with increasing F0 separation, similar to that found with unprocessed sentences. These results emphasize the importance of temporal fine structure for speech perception and demonstrate a potential remedy for difficulty in the perceptual segregation of competing speech sounds.  相似文献   

19.
Speech production parameters of three postlingually deafened adults who use cochlear implants were measured: after 24 h of auditory deprivation (which was achieved by turning the subject's speech processor off); after turning the speech processor back on; and after turning the speech processor off again. The measured parameters included vowel acoustics [F1, F2, F0, sound-pressure level (SPL), duration and H1-H2, the amplitude difference between the first two spectral harmonics, a correlate of breathiness] while reading word lists, and average airflow during the reading of passages. Changes in speech processor state (on-to-off or vice versa) were accompanied by numerous changes in speech production parameters. Many changes were in the direction of normalcy, and most were consistent with long-term speech production changes in the same subjects following activation of the processors of their cochlear implants [Perkell et al., J. Acoust. Soc. Am. 91, 2961-2978 (1992)]. Changes in mean airflow were always accompanied by H1-H2 (breathiness) changes in the same direction, probably due to underlying changes in laryngeal posture. Some parameters (different combinations of SPL, F0, H1-H2 and formants for different subjects) showed very rapid changes when turning the speech processor on or off. Parameter changes were faster and more pronounced, however, when the speech processor was turned on than when it was turned off. The picture that emerges from the present study is consistent with a dual role for auditory feedback in speech production: long-term calibration of articulatory parameters as well as feedback mechanisms with relatively short time constants.  相似文献   

20.
Although cochlear implant (CI) users have enjoyed good speech recognition in quiet, they still have difficulties understanding speech in noise. We conducted three experiments to determine whether a directional microphone and an adaptive multichannel noise reduction algorithm could enhance CI performance in noise and whether Speech Transmission Index (STI) can be used to predict CI performance in various acoustic and signal processing conditions. In Experiment I, CI users listened to speech in noise processed by 4 hearing aid settings: omni-directional microphone, omni-directional microphone plus noise reduction, directional microphone, and directional microphone plus noise reduction. The directional microphone significantly improved speech recognition in noise. Both directional microphone and noise reduction algorithm improved overall preference. In Experiment II, normal hearing individuals listened to the recorded speech produced by 4- or 8-channel CI simulations. The 8-channel simulation yielded similar speech recognition results as in Experiment I, whereas the 4-channel simulation produced no significant difference among the 4 settings. In Experiment III, we examined the relationship between STIs and speech recognition. The results suggested that STI could predict actual and simulated CI speech intelligibility with acoustic degradation and the directional microphone, but not the noise reduction algorithm. Implications for intelligibility enhancement are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏