首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Surface-initiated atom-transfer radical polymerization (ATRP) of poly(ethylene glycol) monomethacrylate (PEGMA) was carried out on the hydrogen-terminated Si(100) substrates with surface-tethered alpha-bromoester initiator. Kinetic studies confirmed an approximately linear increase in polymer film thickness with reaction time, indicating that chain growth from the surface was a controlled "living" process. The "living" character of the surface-grafted PEGMA chains was further ascertained by the subsequent extension of these graft chains, and thus the graft layer. Well-defined polymer brushes of near 100 nm in thickness were grafted on the Si(100) surface in 8 h under ambient temperature in an aqueous medium. The hydroxyl end groups of the poly(ethylene glycol) (PEG) side chains of the grafted PEGMA polymer were derivatized into various functional groups, including chloride, amine, aldehyde, and carboxylic acid groups. The surface-functionalized silicon substrates were characterized by reflectance FT-IR spectroscopy and X-ray photoelectron spectroscopy (XPS). Covalent attachment and derivatization of the well-defined PEGMA polymer brushes can broaden considerably the functionality of single-crystal silicon surfaces.  相似文献   

2.
李新松 《高分子科学》2010,28(5):705-713
<正>Poly(vinylidenefluoride-hexafluoropropylene)(PVDF-HFP) nanofiber membranes with improved hydrophilicity and protein fouling resistance via surface graft copolymerization of hydrophilic monomers were prepared.The surface modification involves atmospheric pressure glow discharge plasma(APGDP) pretreatment followed by graft copolymerization of poly(ethylene glycol) methyl ether methacrylate(PEGMA).The success of the graft modification with PEGMA on the PVDF-HFP fibrous membrane is ascertained by X-ray photoelectron spectroscopy(XPS) and attenuated total reflectance Fourier transform infrared measurements(ATR-FTIR).The hydrophilic property of the nanofiber membranes is assessed by water contact angle measurements.The results show that the PEGMA grafted PVDF-HFP nanofiber membrane has a water contact angle of 0°compared with the pristine value of 132°.The protein adsorption was effectively reduced after PEGMA grafting on the PVDF-HFP nanofiber membrane surface.The PEGMA polymer grafting density on the PVDF-HFP membrane surface is measured by the gravimetric method,and the filtration performance is characterized by the measurement of water flux.The results indicate that the water flux of the grafted PVDF-HFP fibrous membrane increases significantly with the increase of the PEGMA grafting density.  相似文献   

3.
The ability to manipulate and control the surface properties of nylons is of crucial importance to their widespread applications. In this work, surface-initiated atom-transfer radical polymerization (ATRP) is employed to tailor the functionality of the nylon membrane and pore surfaces in a well-controlled manner. A simple two-step method, involving the activation of surface amide groups with formaldehyde and the reaction of the resulting N-methylol polyamide with 2-bromoisobutyryl bromide, was first developed for the covalent immobilization of ATRP initiators on the nylon membrane and its pore surfaces. Functional polymer brushes of 2-hydroxyethyl methacrylate (HEMA) and poly(ethylene glycol)monomethacrylate (PEGMA) were prepared via surface-initiated ATRP from the nylon membranes. A kinetics study revealed that the chain growth from the membranes was consistent with a "controlled" process. The dormant chain ends of the grafted HEMA polymer (P(HEMA)) and PEGMA polymer (P(PEGMA)) on the nylon membranes could be reactivated for the consecutive surface-initiated ATRP to produce the corresponding nylon membranes functionalized by P(HEMA)-b-P(PEGMA) and P(PEGMA)-b-P(HEMA) diblock copolymer brushes. In addition, membranes with grafted P(HEMA) and P(PEGMA) brushes exhibited good resistance to protein adsorption and fouling under continuous-flow conditions.  相似文献   

4.
A simple one-step method for the chloromethylation of polyimide (PI) under mild conditions was used to introduce benzyl chloride groups into PI film surface. Covalently tethered hydrophilic polymer brushes of poly(ethylene glycol) monomethacrylate (PEGMA) and glycidyl methacrylate (GMA) were prepared via surface initiated atom-transfer radical polymerization (ATRP) from the chloromethylated PI surfaces using benzyl chloride groups as the active ATRP initiators. A kinetics study indicated that the chain growth from the films was in agreement with a controlled process. The dormant chain ends of the grafted polymer on the PI films could reinitiate the consecutive surface-initiated ATRP to prepare surface-functionalized diblock copolymer brushes on the PI films. The modified surface was characterized by X-ray photoelectron spectroscopy (XPS) after each modification stage. Protein adsorption experiments indicated that the PI-P(PEGMA) membrane exhibited substantially improved anti-fouling properties compared to the pristine PI surface.  相似文献   

5.
Surface-initiated atom transfer radical polymerization (ATRP) was used to graft hydrophilic comb-like poly((poly(ethylene glycol) methyl ether methacrylate), or P(PEGMA), brushes from chloromethylated poly(phthalazinone ether sulfone ketone) (CMPPESK) membrane surfaces. Prior to ATRP, chloromethylation of PPESK was beforehand performed and the obtained CMPPESK was prepared into porous membranes by phase inversion process. It was demonstrated that the benzyl chloride groups on the CMPPESK membrane surface afforded effective macroinitiators to graft the well-defined polymer brushes. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS) confirmed the grafting of P(PEGMA) chains. Water contact angle measurements indicated that the introduction of P(PEGMA) graft chains promoted remarkably the surface hydrophilicity of PPESK membranes. The effects of P(PEGMA) immobilization on membrane morphology, permeability and fouling resistance were investigated. It was found that the comb-like P(PEGMA) grafts brought smaller pore diameters and higher solute rejections to PPESK membranes. The results of dynamic anti-fouling experiments showed the anti-fouling ability of the membranes was significantly improved after the grafting of P(PEGMA) brushes.  相似文献   

6.
The plastic material known as cyclic olefin copolymer (COC) is a useful substrate material for fabricating microfluidic devices due to its low cost, ease of fabrication, excellent optical properties, and resistance to many solvents. However, the hydrophobicity of native COC limits its use in bioanalytical applications. To increase surface hydrophilicity and reduce protein adsorption, COC surfaces were photografted with poly(ethylene glycol) methacrylate (PEGMA) using a two-step sequential approach: covalently-bound surface initiators were formed in the first step and graft polymerization of PEGMA was then carried out from these sites in the second step. Contact angle measurements were used to monitor and quantify the changes in surface hydrophilicity as a function of grafting conditions. As water droplet contact angles decreased from 88 degrees for native COC to 45 degrees for PEGMA-grafted surfaces, protein adsorption was also reduced by 78% for the PEGMA-modified COC microchannels as determined by a fluorescence assay. This photografting technique should enable the use of COC microdevices in a variety of bioanalytical applications that require minimal nonspecific adsorption of biomolecules.  相似文献   

7.
In general, it is a challenge to control the highly polar material grafting from the chemically inert Teflon-based membrane surface. This work describes the surface modification and characterization of expanded poly(tetrafluoroethylene) (ePTFE) membranes grafted with poly(ethylene glycol) methacrylate (PEGMA) macromonomer via surface-activated plasma treatment and thermally induced graft copolymerization. The chemical composition and microstructure of the surface-modified ePTFE membranes were characterized by Fourier transform infrared spectroscopy (FT-IR), contact angle, and bio-atomic force microscopy (bio-AFM) measurements. Biofouling property of the modified membranes was evaluated by the measurements of the plasma protein (γ-globulin, fibrinogen, or albumin) adsorption determined using an enzyme-linked immunosorbent assay (ELISA). In general, the hydrophilicity of the surface of ePTFE membranes increases with increasing the grafting degree of the copolymerized PEGMA. The highly hydrated PEGMA chain on the resulting ePTFE membranes was found to form a surface hydrogel-like layer with regulated coverage in aqueous state, which can be controlled by the content of PEGMA macromonomer in the reaction solution. The relative protein adsorption was effectively reduced with increasing capacity of the hydration for the PEGMA chain grafted on the ePTFE membrane surface. From both results of protein adsorption and platelet adhesion test in vitro, it is concluded that the PEGMA-grafted hydrophilic ePTFE membranes could provide good biofouling resistance to substantially reduce plasma protein and blood platelet fouling on the membrane surface in human body temperature.  相似文献   

8.
The direct preparation of grafting polymer brushes from commercial poly (vinylidene fluoride) (PVDF) films with surface‐initiated atom transfer radical polymerization (ATRP) is demonstrated. The direct initiation of the secondary fluorinated site of PVDF facilitated grafting of the hydrophilic monomers from the PVDF surface. Homopolymer brushes of 2‐(N,N‐dimethylamino)ethyl methacrylate (DMAEMA) and poly (ethylene glycol) monomethacrylate (PEGMA) were prepared by ATRP from the PVDF surface. The chemical composition and surface topography of the graft‐functionalized PVDF surfaces were characterized by X‐ray photoelectron spectroscopy, attenuated total reflectance/Fourier transform infrared spectroscopy, and atomic force microscopy. A kinetic study revealed a linear increase in the graft concentration of poly[2‐(N,N‐dimethylamino)ethyl methacrylate] (PDMAEMA) and poly[poly(ethylene glycol) monomethacrylate] (PPEGMA) with the reaction time, indicating that the chain growth from the surface was consistent with a controlled or living process. The living chain ends were used as macroinitiators for the synthesis of diblock copolymer brushes. The water contact angles on PVDF films were reduced by the surface grafting of DMAEMA and PEGMA. Protein adsorption experiments revealed a substantial antifouling property of PPEGMA‐grafted PVDF films and PDMAEMA‐grafted PVDF films in comparison with the pristine PVDF surface. © 2006 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 44: 3434–3443, 2006  相似文献   

9.
A reversible addition–fragmentation chain transfer (RAFT) polymerization technique was applied to graft polymerize brushes of poly(methyl methacrylate) (PMMA) and poly(poly(ethylene glycol) monomethacrylate) (PPEGMA) from poly(vinylidene fluoride) (PVDF) surfaces. PVDF surfaces were exposed to aqueous LiOH, followed by successive reductions with NaBH4 and DIBAL‐H to obtain hydroxyl functionality. Azo‐functionalities, as surface initiators for grafting, were immobilized on the PVDF surfaces by esterification of 4,4′‐azobis(4‐cyanopentanoic acid) and the surface hydroxyl groups. The chemical composition and surface topography of the graft‐functionalized PVDF surfaces were characterized by X‐ray photoelectron spectroscopy, attenuated total reflectance‐FTIR spectroscopy, and atomic force microscopy. Kinetics studies revealed a linear increase in the graft concentration of PMMA and PPEGMA with the reaction time, indicating that the chain growth from the surface was consistent with a “controlled” or “living” process. The living chain ends were used as the macroinitiator for the synthesis of diblock copolymer brushes. Water contact angles on PVDF films were reduced by surface grafting of PEGMA and MMA. © 2006 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 44: 3071–3082, 2006  相似文献   

10.
Epoxide and aldehyde end‐functionalized poly(ethylene glycol)s (PEGs) (Mw = 400, 1000, 3400, 5000, and 20,000) were grafted to poly(ethylene terephthalate) (PET) film substrates that contained amine or alcohol groups. PET‐PAH and PET‐PEI were prepared by reacting poly(allylamine) (PAH) and polyethylenimine (PEI) with PET substrates, respectively; PET‐PVOH was prepared by the adsorption of poly(vinyl alcohol) (PVOH) to PET substrates. Grafting was characterized and quantified by the increase of the intensity of the PEG carbon peak in the X‐ray photoelectron spectra. Grafting yield was optimized by controlling reaction parameters and was found to be substrate‐independent in general. Graft density consistently decreased as PEG chain length was increased. This is likely due to the higher steric requirement of higher molecular weight PEG molecules. Water contact angles of surfaces containing long PEG chains (3400, 5000, and 20,000) are much lower than those containing shorter PEG chains (400 and 1000). This indicates that longer PEG chains are more effective in rendering surfaces hydrophilic. Protein adsorption experiments were carried out on PET‐ and PEG‐modified derivatives using collagen, lysozyme, and albumin. After PEG grafting, the amount of protein adsorbed was reduced in all cases. Trends in surface requirements for protein resistance are: surfaces with longer PEG chains and higher chain density, especially the former, are more protein resistant; PEG grafted to surfaces containing branched or network polymers is not effective at covering the underlying substrate, and thus does not protect the entire surface from protein adsorption; and substrates containing surface charge are less protein‐resistant. © 2004 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 42: 5389–5400, 2004  相似文献   

11.
Poly(PEGMA) homopolymer brushes were developed by atom transfer radical polymerization (ATRP) on the initiator-modified silicon surface (Si-initiator). Through covalent binding, protein immobilization on the poly(PEGMA) films was enabled by further NHS-ester functionalization of the poly(PEGMA) chain ends. The formation of polymer brushes was confirmed by assessing the surface composition (XPS) and morphology (atomic force microscopy (AFM), scanning electronic microscopy (SEM)) of the modified silicon wafer. The binding performance of the NHS-ester functionalized surfaces with two proteins horseradish peroxidase (HRP) and chicken immunoglobulin (IgG) was monitored by direct observation. These results suggest that this method which incorporates the properties of polymer brush onto the binding surfaces may be a good strategy suitable for covalent protein immobilization.  相似文献   

12.
Zou  X. P.  Kang  E. T.  Neoh  K. G. 《Plasmas and Polymers》2002,7(2):151-170
Argon plasma-induced graft polymerization of a solution-coated macromonomer, poly(ethylene glycol) methyl ether methacrylate (PEGMA), on the Si(100) surface was carried out to impart anti-fouling properties to the Si(100) surface. The surface composition and microstructure of the PEGMA graft-polymerized Si(100) surfaces were characterized by X-ray photoelectron spectroscopy (XPS), Fourier-transform infrared spectroscopy (FTIR), and atomic force microscopy (AFM) measurements. The extent of crosslinking in the plasma-graft polymerized PEGMA (pp-PEGMA) was estimated by gel fraction determination. In general, an appropriate RF power of about 15 W and a PEGMA macromonomer concentration of about 1 wt% in the coating solution for plasma polymerization produced a high graft yield of pp-PEGMA on the Si(100) surface (the pp-PEGMA-g-Si surface). The Si(100) surface with a high concentration of the grafted pp-PEGMA was effective in preventing bovine serum albumin (BSA) adsorption and platelet adhesion.  相似文献   

13.
Combining hydrophobic materials such as polydimethylsiloxane (PDMS), a natural hydrophobic material with typical hydrophilic monomers without using organic solvent remains a big challenge due to their extreme different properties; hence, fabricating a class of silicone hydrogels with two extremes without use of organic solvents could bring us a novel class of silicone hydrogels. Herein, a range of PDMS‐HEMA‐PEGMA hydrogels was prepared from hydroxyl‐terminated PDMS, 2‐hydroxyethylmethacrylate (HEMA), poly (ethylene glycol) methacrylate (PEGMA), and isophorone diisocyanate via condensation and radical copolymerization reactions. The infrared results confirmed the PDMS‐HEMA‐PEGMA network formation, while the hydrophilicity of the as‐prepared block copolymer was dependent on (PDMS‐HEMA)/PEGMA ratio. Increasing the PEGMA content resulted in increased equilibrium water content, phase separation, surface roughness, and tensile strength, while the tensile modulus, elongation at break, optical transmittance, water contact angle, and oxygen permeability (Dk) were decreasing. At PEGMA content of 28.3%, the relative protein adsorption ratio decreased to 20% and 36% for bovine serum albumin and lysozyme, respectively, compared with that of the control (PDMS‐HEMA), suggesting antiprotein adsorption ability. In overall, the results showed that the PDMS‐HEMA‐PEGMA hydrogels not only exhibited remarkable hydrophilicity and suppressed protein adsorption but also maintained higher optical transparency and oxygen permeability (Dk).  相似文献   

14.
Surface-initiated polymerizations were carried out from polymeric surfaces of commercially important polyester films, poly(ethylene terephthalate) (PET) and poly(ethylene naphthalate) (PEN). These plastic films were modified prior to polymerization by plasma oxidation, exposing surface hydroxyl groups, in order to immobilise patterned self assembled monolayers (SAMs) of trichlorosilane initiator, through the soft lithographic method of microcontact printing (μCP). Subsequently, polymerizations were initiated from the surface via controlled atom transfer radical polymerization (ATRP), under aqueous conditions, to create patterned brushes of the thermo-responsive polymer poly(N-isopropyl acrylamide) (PNIPAM). By creating patterned, rather than homogeneous brushes characterization was made possible by atomic force microscopy (AFM).  相似文献   

15.
The possibility of using a novel comb polymer consisting of a chitosan backbone with grafted 44 units long poly(ethylene oxide) side chains for reducing nonspecific protein adsorption to gold surfaces functionalized by COOH-terminated thiols has been explored. The comb polymer was attached to the surface in three different ways: by solution adsorption, covalent coupling, and microcontact printing. The protein repellent properties were tested by monitoring the adsorption of bovine serum albumin and fibrinogen employing surface plasmon resonance and imaging null ellipsometry. It was found that a significant reduction in protein adsorption is achieved as the comb polymer layer is sufficiently dense. For solution adsorption this was achieved by adsorption from high pH solutions. On the other hand, the best performance of the microcontact printed surfaces was obtained when the stamp was inked either at low or at high pH. For a given comb polymer layer thickness/poly(ethylene oxide) density, significant differences in protein repellent properties were observed between the different preparation methods, and it is suggested that a reduction in the mobility of the comb polymer layer generated by covalent attachment favors a reduced protein adsorption.  相似文献   

16.
Block and random PEGylated copolymers of poly(ethylene glycol) methacrylate (PEGMA) and polystyrene (PS) were synthesized with a controlled polydispersity using an atom transfer radical polymerization method and varying molar mass ratios of PS/PEGMA. Two types of PEGylated copolymers were self-assembly coated onto the surface of poly(vinylidene fluoride) (PVDF) ultrafiltration membranes for enhancing biofouling resistance. It was found that the adsorption capacities of random copolymers on PVDF membranes were all higher than those of block copolymers. However, the specific and overall protein resistance of bovine serum albumin (BSA) on PVDF membranes coated with block copolymers was much higher than that with random copolymers. The increase in styrene content in copolymer increased the amount of polymer coating on the membrane, and the increase in PEGMA content enhanced the protein resistance of membranes. The optimum PS/PEGMA ratio was found to be close to 2 for the best resistance of protein adsorption and bacterial adhesion on the PEGylated diblock copolymer-coated membranes. The PVDF membrane coated with such a copolymer owned excellent biofouling resistance to BSA, humic acid, negatively surface charged bacteria E. coli, and positively surface charged bacteria S. maltophilia.  相似文献   

17.
This study investigates the role that surface functionalisation of silicone elastomer (SE) by atmospheric pressure plasma induced graft immobilisation of poly(ethylene glycol) methyl ether methacrylate (PEGMA) plays in the attendant biological response. SE is used in modern ophthalmic medical devices and samples of the material were initially plasma treated using a dielectric barrier discharge reactor (DBD) to introduce reactive oxygen functionalities, prior to in situ grafting of two molecular weights of PEGMA (MW 1000 Da: PEGMA(1000), MW 2000 Da: PEGMA(2000)). The variously processed surfaces were characterised by water contact angle analysis, X-ray photoelectron spectroscopy, time-of-flight secondary ion mass spectrometry and atomic force microscopy. Lens epithelial cells were then cultured on the PEGMA grafted SE surfaces. It was found that cells on the pristine surface were not well spread and had shrunken morphology. On the DBD pre-treated surfaces, the cells were well spread. On the PEGMA(1000) surface, the cells displayed evidence of shrinkage and were on the verge of detaching. Remarkably, on the PEGMA(2000) surface, no cell adhesion was detection. Bacterial adhesion to the surfaces was studied using Staphylococcus aureus NTC8325. There was no difference in the number of bacteria adhering to any of the surfaces studied.  相似文献   

18.
Surfaces coated with poly(ethylene oxide) containing nonionic polymers are of interest in medical applications due to, among other things, the low adsorption of proteins on such surfaces. In this paper we have studied the interfacial properties of surfaces coated with PEO by measuring the forces acting between two such surfaces in water and across a protein solution as well as between one such surface and a surface carrying adsorbed proteins. One type of surface coating was a graft copolymer of poly(ethylene imine) and poly(ethylene oxide) where the cationic poly(ethylene imine) group anchored the polymer to negatively charged mica surfaces. Three different ways to prepare this coating was used and compared. It was found that this coating was not stable in the presence of lysozyme, a small positively charged protein, when the PEO graft density was low. The other type of coating was obtained by adsorbing ethyl(hydroxyethyl)-cellulose onto hydrophobised mica surfaces. The driving force for adsorption is in this case the hydrophobic interaction between nonpolar segments of the polymer and the surface. The EHEC coating was stable in the presence of lysozyme and the interactions between adsorbed layers of lysozyme and EHEC coated surfaces are purely repulsive due to long-range steric forces.  相似文献   

19.
The uncontrolled accumulation of biological materials on the surface of medical devices through protein adsorption or cell adhesion causes adverse biological reactions in the living host system, leading to complications. In this study, poly(ethylene glycol) (PEG) is successfully grafted onto polyurethane (PU) surfaces by using a new strategy through a simple and efficient transurethanization reaction. The PEG hydroxyl group is deprotonated and then reacted with the PU surface to provide antiadhesive hydrophilic surfaces in a single step. Surface analysis techniques proved the grafting to be efficient and the formation of a hydrophilic polymeric layer at the surface of PU. Biological assays showed that the surface modification induced lower protein adsorption, cell, platelet, and bacterial adhesion than untreated surfaces, showing a potential for biomedical applications.  相似文献   

20.
PEGylated Nb2O5 surfaces were obtained by the adsorption of poly(L-lysine)-g-poly(ethylene glycol) (PLL-g-PEG) copolymers, allowing control of the PEG surface density, as well as the surface charge. PEG (MW 2 kDa) surface densities between 0 and 0.5 nm(-2) were obtained by changing the PEG to lysine-mer ratio in the PLL-g-PEG polymer, resulting in net positive, negative and neutral surfaces. Colloid probe atomic force microscopy (AFM) was used to characterize the interfacial forces associated with the different surfaces. The AFM force analysis revealed interplay between electrical double layer and steric interactions, thus providing information on the surface charge and on the PEG layer thickness as a function of copolymer architecture. Adsorption of the model proteins lysozyme, alpha-lactalbumin, and myoglobin onto the various PEGylated surfaces was performed to investigate the effect of protein charge. In addition, adsorption experiments were performed over a range of ionic strengths, to study the role of electrostatic forces between surface charges and proteins acting through the PEG layer. The adsorbed mass of protein, measured by optical waveguide lightmode spectroscopy (OWLS), was shown to depend on a combination of surface charge, protein charge, PEG thickness, and grafting density. At high grafting density and high ionic strength, the steric barrier properties of PEG determine the net interfacial force. At low ionic strength, however, the electrical double layer thickness exceeds the thickness of the PEG layer, and surface charges "shining through" the PEG layer contribute to protein interactions with PLL-g-PEG coated surfaces. The combination of AFM surface force measurements and protein adsorption experiments provides insights into the interfacial forces associated with various PEGylated surfaces and the mechanisms of protein resistance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号