共查询到20条相似文献,搜索用时 0 毫秒
1.
《Analytical letters》2012,45(10):1593-1603
This article reports a new simple and sensitive method for the determination of folic acid by adsorptive stripping voltammetry. The method is based on the accumulation of folic acid at a bismuth film plated in situ on a glassy carbon substrate. In order to stabilize bismuth ions, sodium potassium tartrate was added to the supporting electrolyte. The bismuth film formation and folic acid accumulation conditions were optimized and measurements were carried without solution deaeration. The calibration graph was linear from 5 × 10?10 to 2 × 10?8 mole per liter with an accumulation time of 180 seconds with a limit of detection of 2 × 10?10 mole per liter. The relative standard deviation for 5 × 10?9 mole per liter of folic acid was 3.1 percent (n = 5). The method was successfully applied for determination of folic acid in pharmaceutical preparations. 相似文献
2.
Bismuth Film Electrodes for Adsorptive Stripping Voltammetric Determination of Sunset Yellow FCF in Soft Drinks 下载免费PDF全文
Agnieszka Królicka Andrzej Bobrowski Jerzy Zarębski Iwona Tesarowicz 《Electroanalysis》2014,26(4):756-765
The bismuth film electrode was used to record well‐developed voltammograms of azo food coloring Sunset Yellow FCF (SY). The employed Bi(III)/HClO4 plating solutions produced very adhesive and mechanically stable films that were applied in both stationary and flow conditions. The influence of the dimensions of the glassy carbon support, plating solution concentration and potential was discussed. The sensitivity of SWV was sufficient to obtain a linear calibration curve for low concentration levels of SY (below 0.1 mg/L; LOD=1 µg/L, linear range 4.4–87 µg/L). The measurements in a flow system were considered as a tool for the determination of relatively high concentrations (>1 mg/L; LOD=300 µg/L, linear range 300–8800 µg/L) of SY. 相似文献
3.
《Electroanalysis》2006,18(8):823-829
Bismuth coated glassy carbon electrodes have been applied to the square‐wave anodic stripping voltammetry (SWASV) of trace concentrations of tin. Optimization of Bismuth Film Electrode (BFE) performance was conducted after initial comparison with the more traditional mercury electrode. Simultaneous deposition of tin and bismuth at ?1.3 V for 2 minutes in a supporting electrolyte of 2.5 M sodium bromide utilizing a square‐wave stripping step, allowed analysis of tin at the μg L?1 level. Parameters, such as deposition potential and time, bismuth concentration, square‐waveform settings including amplitude, step height and frequency were studied and optimized. The dependence of stripping current on deposition time indicates that using longer deposition time should facilitate sub μg L?1 analysis. Tin was analyzed simultaneously with cadmium and either indium or thallium; Where as lead and copper were not resolved from the stripping peaks of tin and bismuth respectively. Finally, the method was applied to the analysis of tin in fruit juice. 相似文献
4.
Adsorptive Cathodic Stripping Voltammetric Method for Determination of Gallium Using an In Situ Plated Lead Film Electrode 下载免费PDF全文
The in situ plated lead film electrode was proposed for the first time for adsorptive stripping voltammetric determination of gallium in water samples. The method was based on simultaneous lead film formation and Ga(III)‐cupferron complex preconcentration at ?0.7 V and its cathodic stripping during the potential scan. The composition of the supporting electrolyte, cupferron concentration, conditions of lead film formation, potential and time of accumulation were studied in detail. Under optimum conditions the limit of detection was 3.8×10?9 mol L?1. The proposed procedure was validated in the course of Ga(III) determination in waste water certified reference materials. 相似文献
5.
杯芳烃修饰玻碳电极吸附溶出伏安法测定微量铅 总被引:7,自引:0,他引:7
研究了以杯芳烃衍生物修饰玻碳电极,以其吸附溶出伏安法测定微量铅。对富集时间、铅的浓度、支持电解质、样品溶液pH值及部分离子干扰等进行了实验。实验发现以氢氧化钠溶液处理修饰电极可提高测定灵敏度,经过优化处理后,线性范围和检出限分别为5.0×10-7~1.0×10-5mol/L和1.0×10-8mol/L。应用本法对合成水样进行了测定,结果满意。本文还对吸附溶出机理进行了讨论。 相似文献
6.
Voltammetric Behavior of Testosterone on Bismuth Film Electrode: Highly Sensitive Determination in Pharmaceuticals and Human Urine by Square‐Wave Adsorptive Stripping Voltammetry 下载免费PDF全文
Abdulkadir Levent Ahmet Altun Süleyman Taş Yavuz Yardım Zühre Şentürk 《Electroanalysis》2015,27(5):1219-1228
In this paper, an electrochemical application of bismuth‐film electrode (BiFE) fabricated via ex‐situ electrodeposition onto a glassy carbon electrode for testosterone determination was investigated in aqueous and aqueous/surfactant solutions. In cyclic voltammetry, the compound showed one irreversible and adsorption‐controlled reduction peak. The BiFE revealed good linear response in the examined concentration range of 1 to 45 nmol L?1 testosterone in Britton? Robinson buffer, pH 5.0 containing 3 mmol L?1 cetyltrimethylammonium bromide. The limit of detection was 0.3 nmol L?1 (0.09 ng mL?1). Finally, the BiFE was satisfactorily applied for quantitation of testosterone in both pharmaceutical (oil‐based ampoule) and biological (human urine) samples. 相似文献
7.
《Electroanalysis》2006,18(3):223-230
This work reports the use of adsorptive stripping voltammetry (AdSV) for the determination of uranium on a preplated rotating‐disk bismuth‐film electrode (BiFE). The principle of the method relied on the complexation of U(VI) ions with cupferron and the subsequent adsorptive accumulation of the complex on the surface of the BiFE. The uranium in the accumulated complex was then reduced by means of a cathodic voltammetric scan while the analytically useful U(VI)→U(V) reduction signal was monitored. The experimental variables as well as potential interferences were investigated and the figures of merit of the method were established. Using the selected conditions, the 3σ limit of detection for uranium was 0.1 μg L?1 at a preconcentration time of 480 s and the relative standard deviation was 4.7% at the 5 μg L?1 level for a preconcentration time of 120 s (n=8). The accuracy of the method was established by analyzing a reference sea water sample. 相似文献
8.
研究了利用玻碳电极吸附伏安法测定痕量硫化物的新方法。在含高铁离子的酸性溶液中,硫化物与对-氨基苯二甲基盐酸盐(p-ADAD)反应生成亚甲基蓝,采用线性扫描伏安法亚甲基蓝于-0.30 V(vs.SCE)在玻碳电极上出现灵敏的还原峰,峰电流与S2-浓度在0~25μg/mL范围内呈良好的线性关系。优化了实验条件,研究了电极反应机理。该方法具有灵敏、简便、快速、避免汞污染等特点。已成功用于多种水样中痕量硫化物的测定,回收率为98.0%~104.6%,结果令人满意。 相似文献
9.
《Electroanalysis》2004,16(21):1745-1754
This works reports the use of adsorptive stripping voltammetry (AdSV) for the trace determination of chromium on a rotating‐disk bismuth‐film electrode (BFE). During the reductive accumulation step, all the chromium species in the sample were reduced to Cr(III) which was complexed with cupferron and the complex was accumulated by adsorption on the surface of a preplated BFE. The stripping step was carried out by using a square‐wave (SW) potential‐time voltammetric signal. Electrochemical cleaning of the bismuth film was employed, enabling the same bismuth film to be used for a series of measurements in the presence of dissolved oxygen. The experimental variables as well as potential interferences were investigated and the figures of merit of the method were established. Using the selected conditions, the 3σ limit of detection for chromium was 100 ng L?1 (for 120 s of preconcentration) and the relative standard deviation was 3.6% at the 2 μg L?1 level (n=8). Finally, the method was applied to the determination of chromium in real samples with satisfactory results. 相似文献
10.
本文建立了在铋膜修饰电极上采用方波吸附溶出伏安法同时测定纺织品中痕量Co2+和Ni2+的方法.以NH3-NH4Cl作为缓冲液,在丁二酮肟浓度为10 μmol/L的体系中,Co2和Ni2+的还原峰电位分别为-1.13 V和-1.03 V.当缓冲溶液pH为9.2,富集电位为-0.7V,富集时间为200 s时,C02 +和Ni2+在0.5~50 μg/L范围呈现良好的线性关系,相关系数R2>0.99,其检出限分别为0.79 μg/L和0.96 μg/L,其它金属离子的干扰较小.采用标准加入法测定纺织品中Co>和Ni2+,回收率在94.88%~104.14%之间. 相似文献
11.
以铋膜电极为工作电极,采用微分脉冲阳极溶出伏安法直接测定食品样品中痕量铅、镉和锌。在富集电位-1.4V,富集时间180s,铋膜质量浓度150μg·L-1的条件下,铋膜电极对铅、镉和锌的氧化溶出具有良好的电化学响应。铅(Ⅱ)、镉(Ⅱ)和锌(Ⅱ)的质量浓度在5.0~40μg·L-1的范围内与其阳极溶出峰电流呈线性关系,铅(Ⅱ)、镉(Ⅱ)和锌(Ⅱ)的检出限(3S/N)分别为0.80,0.65,0.58μg·L-1。对25μg·L-1铅(Ⅱ)、镉(Ⅱ)和锌(Ⅱ)溶液用铋膜电极连续测定15次,相对标准偏差分别为6.2%,5.1%,7.1%。方法应用于食品中痕量重金属的测定,测定结果与石墨炉原子吸收光谱法的测定值相符。 相似文献
12.
邻苯三酚红修饰碳糊电极吸附伏安法测定痕量铋 总被引:3,自引:0,他引:3
报道了采用邻苯三酚红修饰碳糊电极测定痕量铋的方法。在0.30mol/L的HCl溶液中,于-0.10V搅拌富集3min,然后在-0.35V静止还原60s,再进行阳极化扫描,在-0.10V左右获得灵敏的铋溶出峰,二次导数民流与铋浓度在1.0*10^-9-6.0*10^-7mol/L范围内呈线性关系,同限为5*10^-10mol/L。对电极反应机理进行了讨论。 相似文献
13.
《Electroanalysis》2017,29(7):1783-1793
Ricin, (Ricinus communis agglutinin, RCA) is one of the most poisonous of naturally occurring substances and has great potential for bioterrorism because no antidote exists. Fast detection at low concentrations is a challenge, and vital to the development of proper countermeasures. In this study, a square wave adsorptive stripping voltammetric (SWAdSV) method for determining RCA using a cathodically polarized boron‐doped diamond (BDD) electrode is presented. An irreversible electrochemical RCA oxidation peak was identified on the BDD electrode by different voltammetric techniques using both direct and adsorptive stripping modes. An adsorption‐controlled (slope log Ip vs log v of 0.80) pH‐dependent process was observed. For values of 1.0≤pH≤9.0, the numbers of protons and electrons associated with the oxidation reaction were estimated (ca. 1.0) by differential pulse voltammetry. The RCA oxidation step may correspond to the oxidation of tryptophan amino acid residues, and occurs in a complex mechanism. The excellent analytical performance of the cathodically polarized BDD electrode in combination with the stripping mode ramp was verified with RCA by using a short deposition time in an open circuit potential (120 s). Under optimized analysis conditions, a linear response in the range of (3.3–94.0)×10−9 mol L−1 (r2=0.9944) and a limit of detection of 6.2×10−10 mol L−1 were estimated. This LOD is lower than several methods found in the literature. For example, it is 168 times lower than that obtained by using square wave voltammetric with a glassy carbon electrode. Moreover, an even lower LOD might be achieved by using the SWAdSV method with a higher pre‐concentration time. In addition, trace levels of RCA were successfully determined in different castor seed cultivars with an overall average recovery from 99.2±1.6 % for the three different RCA‐A concentration levels. The high accuracy of the analytical data highlights the use of the proposed method for determining RCA in other samples. 相似文献
14.
《Electroanalysis》2002,14(23):1615-1620
Electrochemically modified glassy carbon electrode (GCE) was used to study the electrochemical oxidation and detection of denatured single‐stranded (ss) DNA by means of adsorptive stripping voltammetry. The modification of GCE, by electrochemical oxidation at +1.75 V (vs.SCE) for 10 min and cyclic sweep between +0.3 V and ?1.3 V for 20 cycles in pH 5.0 phosphate buffer, results in 100‐fold improvement in sensitivity for ssDNA detection. We speculated that the modified GCE has a high affinity to single‐stranded DNA through hydrogen bond (specific static adsorption). Single‐stranded DNA can accumulate at the GCE surface at open circuit and produce a well‐defined oxidation peak corresponding to the guanine residues at about +0.80 V in pH 5.0 phosphate buffer, while the native DNA gives no signal under the same condition. The peak currents are proportional to the ssDNA concentration in the range of 0–18.0 μg mL?1. The detection limit of denatured ssDNA is ca. 0.2 μg mL?1 when the accumulation time is 8 min at open circuit. The accumulation mechanism of ssDNA on the modified GCE was discussed. 相似文献
15.
Luiz Carlos S. Figueiredo‐Filho Déborah C. Azzi Bruno C. Janegitz Orlando Fatibello‐Filho 《Electroanalysis》2012,24(2):303-308
A new method using differential pulse adsorptive stripping voltammetry for the determination of atrazine (ATZ) in natural water samples using a bismuth film electrode (BiFE) is proposed. The calibration curve was linear in the atrazine concentration range from 6.7×10?7 to 2.0×10?5 mol L?1, with a limit of detection (LOD) of 1.4×10?7 mol L?1. The proposed electrode was applied for atrazine determination with satisfactory results compared with a high‐performance liquid chromatography method (HPLC). 相似文献
16.
修饰铋盘电极吸附伏安法测定痕量钴的研究 总被引:1,自引:0,他引:1
研究了利用丁二酮肟修饰铋电极测定钴的吸附伏安分析方法。在0.4 mol/L NH3.H2O-NH4Cl缓冲溶液(pH=9.0)中,Co(Ⅱ)与铋盘电极表面修饰的丁二酮肟形成螯合物。并于-1.20 V附近产生一个灵敏的还原峰。富集时间分别为60 s和280 s时,峰电流与钴的质量浓度在0.01~25μg/mL和0.002~2μg/mL范围内呈线性关系。该还原峰与采用汞电极时的峰形相似、电位相近、灵敏度相当。优化了实验条件,拟订了样品分析的步骤,利用该法测定了合金、维生素B12针剂样品中的微量钴。 相似文献
17.
《Electroanalysis》2006,18(24):2486-2489
This paper presents the enhanced analysis of copper on a bismuth electrode upon addition of gallium(III). The presence of gallium alleviates the problems of overlapping stripping signals usually observed between copper and bismuth when using the Bismuth Film Electrode. In addition, it has been found that the presence of gallium improves the reproducibility of the bismuth stripping signal. Simultaneous deposition of copper and bismuth at ?1500 mV for 2 minutes in a supporting electrolyte composed of 0.1 M pH 4.75 acetate buffer with 250 μg L?1 gallium yields well resolved copper and bismuth signals when analyzed with square‐wave anodic stripping voltammetry. Simultaneous analysis of copper and lead yielded linear calibration plots in the range 10 to 100 μg L?1 with regression coefficients of 0.997 and 0.994 respectively. The theoretical detection limit for copper was calculated to be 4.98 μg L?1 utilizing a 2 minutes deposition time. The relative standard deviation for a copper concentration of 50 μg L?1 was 1.6% (n=10). 相似文献
18.
《Analytical letters》2012,45(7):1000-1013
Abstract A Nafion/ionophore, 4-tert-butylcalix[4]arene-tetrakis(N,N-dimethylthioacetamide) composite coated and bismuth film modified glassy carbon electrode. (GC/NA-IONO/BiFE) was described to determine trace lead sensitively and selectively. The characteristics of such modified GC/NA-IONO/BiFE were studied by scanning electron microscopy and cyclic voltammetry. The influence of various experimental parameters upon the stripping lead signal at the GC/NA-IONO/BiFE was explored. Under the optimized conditions, the differential pulse voltammetric stripping response is highly linear over the 0.1–8.0 nM lead range examined (180 s preconcentration at ?1.2 V), with a detection limit of 0.044 nM and good precision (RSD = 5.4% at 0.5 nM). Also applicability to seawater samples was demonstrated at such modified electrode. The high selectivity of ionophore coupled with the excellent electrochemical characteristics of bismuth endow the GC/NA-IONO/BiFE a promising and robust tool for monitoring of trace lead rapidly and precisely. 相似文献
19.
Margarita Stoytcheva Roumen Zlatev Zdravka Velkova Velizar Gochev Alan Ayala Gisela Montero Benjamín Valdez 《Electroanalysis》2021,33(3):695-704
A laponite modified carbon paste electrode was prepared, characterized and applied for the 2,4-dichlorophenol (2,4-DCP) voltammetric determination. It takes advantage of the ability of laponite to adsorb phenols, as well as of its availability and very low cost. Kinetic and equilibrium data for 2,4-DCP adsorption by laponite in aqueous dispersions demonstrated that the adsorption process obeyed a pseudo first order kinetic model and was consistent with the formation of adsorbed multilayers on a surface with heterogeneous pore distribution. The composite paste electrode exhibited a heterogeneous surface with 65 % increased surface area and 27 % enhanced catalytic activity compared to the unmodified one. The adsorptive stripping voltammetric determination of 2,4-DCP at an electrode with an optimized graphite:laponite ratio of 55 : 15 w% using a 3 min accumulation time at pH 5.5 was found to be suitable for its quantification in the linear concentration range extended up to 50 μmol L−1 with a sensitivity of 0.56 μA L μmol−1 and a LOD of 0.2 μmol L−1 (S/N=3).The 2,4-DCP electrochemical response was not affected by the presence of some structurally similar phenols, like catechol and p-nitrophenol, while resorcinol, 2-chlorophenol, and 4-chlorophenol presented interferences. The results were validated by 2,4-DCP determination in spiked tap water. 相似文献