首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Deoxyribonucleic acid (DNA) was electrochemically deposited on a carbon ionic liquid electrode to give a biosensor with excellent redox activity towards paraquat as shown by cyclic voltammetry and differential pulse voltammetry. Experimental conditions were optimized with respect to sensing paraquat by varying the electrochemical parameters, solution pH, and accumulation time of DNA. Under the optimized conditions, a linear relation exists between the reduction peak current and the concentration of paraquat in the range from 5?×?10?8 mol L?1 to 7?×?10?5 mol L?1, with a detection limit of 3.6?×?10?9 mol L?1. The utility of the method is illustrated by successful analysis of paraquat in spiked real water samples.
Figure
The DNA was electrodeposited onto the CILE under +1.5?V for 1200?s. The electrochemical behaviors of paraquat on the modified electrode had been studied by cyclic voltammetry and differential pulse voltammetry. Five ml phosphate buffer (pH 7.0) solution was added into an electrochemical cell (10?ml) and then paraquat was successfully added into the cell. The differential pulse voltammograms were recorded when swept from ?0.8?V to ?0.3?V. The peak currents at about ?0.63?V for paraquat were measured.  相似文献   

2.
A sensitive and reliable method is described for the determination of total Sb(III,?V) at traces levels by Osteryoung square-wave anodic stripping voltammery (OSWASV). This method is based on the co-deposition of Sb(III,?V) with Bi(III) onto an edge-plane pyrolytic graphite substrate at an accumulation step. OSWASV studies indicated that the co-deposited antimony was oxidised with anodic scans to give an enhanced anodic peak at about 450?mV vs. Ag/AgCl (sat. KCl). The anodic stripping peak current was directly proportional to the total concentration of antimony in the ranges of 0.01–0.10?µg?L?1, 0.10–1.0?µg?L?1 and 1.0–18.0?µg?L?1 with correlation coefficient higher than 0.995 when 2.0?mol?L?1 hydrochloric acid was used. The detection limits calculated as S/N?=?3 was 5.0?ng?L?1 in 2.0?mol?L?1 hydrochloric acid at 180?s deposition time. The relative standard deviation was 5% (n?=?6) at 0.10?µg?L?1 level of antimony. The analytical results demonstrate that the proposed method is applicable to analyses of real water samples.  相似文献   

3.
The use of a thin thiol‐functionalized silica film modified glassy carbon electrode in the determination of Hg(II) ions in a natural water sample is described. A typical measurement involves two successive steps: a glassy carbon electrode coated with a thin mesoporous silica film containing 10% of mercaptopropyl groups, according to the MPTMS/TEOS ratio in the starting sol‐gel, was first immersed into the accumulation medium for 15 min, then removed, and finally transferred into a detection solution containing KCl 1.0 mol L?1 where detection was performed by anodic stripping voltammetry. In this medium the previously accumulated Hg2+ species complexed by the thiol groups in an open circuit preconcentration step is then directly reduced at ?0.6 V during 60 s prior to be quantified by a differential pulse anodic scan from ?0.6 to 0.3 V (vs. Ag/AgCl). A stripping peak appeared at about ?0.01 V, which is directly proportional to the quantity of the analyte previously accumulated into the film. The best results were obtained under the following conditions: 100 mV pulse amplitude and 10 mV s?1 scan rate in 1.0 mol L?1 KCl solution pH 2.0. Using such parameters a linear dynamic range from 1.00 to 10.0×10?8 mol L?1 Hg(II) was observed with a limit of detection of 4.3 nmol L?1 for an accumulation time of 15 min. Hg(II) spiked in a natural water sample was determined between 97.0 and 101.4% mean recovery at 10?8 mol L?1 level. The results indicate that this electrode is sensitive and selective for the Hg(II)determination.  相似文献   

4.
Chemical sensors relying on graphene-based materials have been widely used for electrochemical determination of metal ions and have demonstrated excellent signal amplification. This study reports an electrochemically reduced graphene oxide (ERGO)/mercury film (HgF) nanocomposite-modified pencil graphite electrode (PGE) prepared through successive electrochemical reduction of graphene oxide (GO) sheets and an in situ plated HgF. The ERGO-PG-HgFE, in combination with dimethylglyoxime (DMG) and square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV), was evaluated for the determination of Ni2+ in tap and natural river water samples. A single-step electrode pre-concentration approach was employed for the in situ Hg-film electroplating, metal-chelate complex formation, and non-electrolytic adsorption at –0.7 V. The current response due to nickel-dimethylglyoxime [Ni(II)-DMG2] complex reduction was studied as a function of experimental paratmeters including the accumulation potential, accumulation time, rotation speed, frequency and amplitude, and carefully optimized for the determination of Ni2+ at low concentration levels (μg?L?1) in pH 9.4 of 0.1 M NH3–NH4Cl buffer. The reduction peak currents were linear with the Ni2+ concentration between 2 and 16?μg?L?1. The limits of detection and quantitation were 0.120?±?0.002?µg?L?1 and 0.401?±?0.007?µg?L?1 respectively, for the determination of Ni2+ at an accumulation time of 120?s. The ERGO-PG-HgFE further demonstrated a highly selective stripping response toward Ni2+ determination compared to Co2+. The electrode was found to be sufficiently sensitive to determine metal ions in water samples at 0.1?µg?L?1, well below the World Health Organization standards.  相似文献   

5.
《Electroanalysis》2005,17(4):343-347
The adsorptive voltammetric behavior of the gallium‐alizarin red S (ARS) complex in NH4OAc‐HCl buffer at a carbon paste electrode(CPE) was investigated. The results showed that the complex can be adsorbed on the surface of the CPE, yielding one reduction peak at ?0.52 V(vs. SCE), corresponding to the irreversible reduction of the ligand, ARS, bonded in the complex. The optimal experimental conditions include the use of 0.10 mol L?1 ammonium acetate buffer(pH 4.5), 1.0×10?5 mol L?1 ARS, an accumulation potential of ?0.05 V, an accumulation time of 180 s ,a rest time of 10 s, a scan rate of 200 mV s?1and a second‐order derivative linear scan mode. The peak current is proportional to the concentration of gallium(III) over the range 0.02–6.0 μg L?1, with the detection limit of 0.01 μg L?1 for an accumulation time of 180 s. The method was applied to the determination of gallium in food samples with satisfactory results.  相似文献   

6.
《Electroanalysis》2006,18(15):1457-1462
This work describes an electroanalytical method for determining gold(I) thiomalate, aurothiomalate, widely used for treatment of reumatoid arthiritis, using a screen‐printed carbon electrode (SPCE). Aurothiomalate (AuTM) was determined indirectly at the same electrode by accumulating it first at ?1.5 V vs. printed carbon. At this potential in the adsorbed state, the AuTM is reduced to Au(0), which is then oxidized at two steps at ?0.22 V and +0.54 V on SPCE. Using optimized conditions of 60 s deposition time, ?1.5 V (vs. printed carbon) accumulation potential, 100 mV s?1 scan rate, linear calibration graphs can be obtained by monitoring the peak at +0.54 V for AuTM in HCl 0.1 mol L?1 from 1.43×10?6 to 1.55×10?4 mol L?1. A limit of detection obtained was 6.50×10?7 mol L?1, and the relative standard deviation from five measurements of 3.0×10?5 mol L?1 AuTM is 4.5%. The method was successfully applied for AuTM determination in human urine sample.  相似文献   

7.
A carbon paste electrode (CPE) was modified with multi-wall carbon nanotubes and successfully applied to the determination of silver ion by differential pulse anodic stripping voltammetry. Compared to a conventional CPE, a remarkably improved peak current response and sensitivity is observed. The analytical procedure consisted of an open circuit accumulation step for 2?min in ?0.4?V, this followed by an anodic potential scan between +0.2 and?+?0.6?V to obtain the voltammetric peak. The oxidation peak current is proportional to the concentration of silver ion in the range from 1.0?×?10?8 to 1.0?×?10?5?mol?L?1, with a detection limit of 1.8?×?10?9?mol?L?1 after an accumulation time of 120?s. The relative standard deviation for 7 successive determinations of Ag(I) at 0.1???M concentration is 1.99%. The procedure was validated by determining Ag(I) in natural waters.
Figure
Differential pulse voltammogram (DPV) of Ag+ solution at MCPE  相似文献   

8.
We are presenting an electrochemical immunosensor for the determination of the β-agonist and food additive ractopamine. A glassy carbon electrode (GCE) was modified with gold nanoparticles and a film of a composite made from poly(arginine) and multi-walled carbon nanotubes. Antibody against ractopamine was immobilized on the surface of the modified GCE which then was blocked with bovine serum albumin. The assembly of the immunosensor was followed by electrochemical impedance spectroscopy. Results demonstrated that the semicircle diameter increases, indicating that the film formed on the surface hinders electron transfer due to formation of the antibody-antigen complex on the modified electrode. Under optimal conditions, the peak current obtained by differential pulse voltammetry decreases linearly with increasing ractopamine concentrations in the 0.1 nmol?L?1 to 1 μmol?L?1 concentration range. The lower detection limit is 0.1 nmol?L?1. The sensor displays good stability and reproducibility. The method was applied to the analysis of spiked swine feed samples and gave satisfactory results. Figure
Immunoassay for ractopamine based on glassy carbon electrode modified with gold nanoparticles and a film of a composite made from poly (arginine) and multi-walled carbon nanotubes was proposed. Under optimal conditions, the peak currents obtained by differential pulse voltammetry decreases linearly with increasing ractopamine concentrations in the 0.1 nmol?L?1 to 1 μmol?L?1 concentration range. The detection limit is 0.1 nmol?L?1.  相似文献   

9.
Yan Wang  Ming Yin 《Mikrochimica acta》2009,166(3-4):243-249
Microfluidic chip capillary electrophoresis with laser-induced fluorescence detection is employed for direct determination of trace nitric oxide in human blood using diaminorhodamines as the fluorescence probe. Factors influencing the separation and detection processes were systematically studied. Complete and fast separation of the highly fluorescent triazole formed was achieved within 45 s, and the relative standard deviations values of migration time and peak area were less than 3%. The detection limit of NO was 3.0 nmol.L-1 (at a signal-to-noise ratio of 3) and the liner range was from 1.0?×?10-8?mol.L-1 to 3.0?×?10-6?mol.L-1. The method has been applied to the determination of NO in serum of healthy persons and patients suffering from diseases, with recoveries varying from 92.65 to 98.43%.  相似文献   

10.
In a thiocyanate solution containing iron (II), nitrite and ascorbic acid, a linear-sweep polarographic wave appears at ?0.42 V (vs. SCE). In anodic sweeps, the derivative peak current is directly proportional to the concentration of thiocyanate over the range 2×10?8?1×10?6 M; the detection limit is 1×10?8 M. The procedure is used for the determination of trace thiocyanate (10?3?10?4 M) in saliva. The mechanism of the electrode process is discussed; the polarographic wave is ascribed to catalytic reduction of dissolved oxygen in the presence of an adsorbed ternary Fe/SCN/NO complex.  相似文献   

11.
A simple flow injection amperometric system for fast and indirect quantification of dopamine (DA) in the presence of a large excess of ascorbic acid (AA) is reported. The method consists of the application of three sequential potential pulses to an unmodified glassy carbon‐working electrode positioned in a wall‐jet cell. DA is indirectly detected at +0.35 V through the reduction of the oxidation product (o‐dopaminoquinone) electrochemically generated at +0.80 V. The third potential pulse (0.00 V) is applied for the regeneration (cleaning) of the unmodified working electrode. The limits of detection (LOD) and quantification (LOQ) were calculated as 50 and 170 nmol L?1, respectively. Considering the LOQ value, the present methodology allows DA quantification in the presence up to 5000‐fold more of AA (1.0 mmol L?1).  相似文献   

12.
Flow injection analysis with amperometric detection (FIA‐AD) at screen‐printed carbon electrodes (SPCEs) in optimum medium of Britton‐Robinson buffer (0.04 mol ? L?1, pH 2.0) was used for the determination of three tumor biomarkers (homovanillic acid (HVA), vanillylmandelic acid (VMA), and 5‐hydroxyindole‐3‐acetic acid (5‐HIAA)). Dependences of the peak current on the concentration of biomarkers were linear in the whole tested concentration range from 0.05 to 100 μmol ? L?1, with limits of detection (LODs) of 0.065 μmol ? L?1 for HVA, 0.053 μmol ? L?1 for VMA, and 0.033 μmol ? L?1 for 5‐HIAA (calculated from peak heights), and 0.024 μmol ? L?1 for HVA, 0.020 μmol ? L?1 for VMA, and 0.012 μmol ? L?1 for 5‐HIAA (calculated from peak areas), respectively.  相似文献   

13.
A method is described for the sequential determination of Sb(III) and Sb(V) using Osteryoung square wave cathodic stripping voltammetry. It employs an in-situ plated bismuth-film on an edge-plane graphite substrate as the working electrode. Selective electro-deposition of Sb(III)/Sb(V) is accomplished by applying a potential of ?500 mV vs. Ag/AgCl, followed by reduction to stibine at a more negative potential in the stripping step. Stripping was carried out by applying a square wave waveform between ?500 and ?1400 mV to the antimony deposited. The stripping peak current at ?1150 mV is directly proportional to the concentration of Sb( III)/Sb(V). The calibration plots for Sb (III) were linear up to 12.0?µg L?1 depending on the time of deposition. The calibration plots for Sb (V) were linear up to 7.0?µg L?1, also depending on the time of deposition. The relative standard deviation in the determination of 0.1?µg L?1 of Sb(III) is 4.0% (n?=?5), and the limit of detection is as low as 2 ng L?1. In case of 0.1?µg L?1 Sb(V), the relative standard deviation is 3.0% (n?=?5) and the detection limit also is 2 ng L?1. The method was applied to the analysis of river and sea water samples.  相似文献   

14.
In this paper, an electrochemical application of bismuth‐film electrode (BiFE) fabricated via ex‐situ electrodeposition onto a glassy carbon electrode for testosterone determination was investigated in aqueous and aqueous/surfactant solutions. In cyclic voltammetry, the compound showed one irreversible and adsorption‐controlled reduction peak. The BiFE revealed good linear response in the examined concentration range of 1 to 45 nmol L?1 testosterone in Britton? Robinson buffer, pH 5.0 containing 3 mmol L?1 cetyltrimethylammonium bromide. The limit of detection was 0.3 nmol L?1 (0.09 ng mL?1). Finally, the BiFE was satisfactorily applied for quantitation of testosterone in both pharmaceutical (oil‐based ampoule) and biological (human urine) samples.  相似文献   

15.
A sequential AdSV method based on the accumulation of Zr(IV) and V(V) as cupferron‐oxalic acid‐1,3‐diphenylguanidine (COD) complexes at the HMDE was used to determine traces of these metals in samples with different ionic strengths. DP mode, Eads ?0.6 and ?0.2 V (vs. Ag/AgCl, 3 mol L?1 KCl), tads 400 and 20 s and 10 and 60 mV s?1 scan rates were used for Zr(IV) and V(V), respectively. Epeak were ?0.95 (Zr(IV)‐COD) and ?0.65 V(V(V)‐COD). The methodology was applied in samples of rivers, estuaries (in Germany and Brazil) and coastal and open seawater.  相似文献   

16.
Ultrasound-assisted dispersive liquid?Cliquid microextraction (USA-DLLME) with low solvent consumption was demonstrated for gas chromatography-mass spectrometry (GC?CMS) determination of 16 typical polycyclic aromatic hydrocarbons (PAHs) in seawater samples. Factors affecting the extraction process, such as extraction and dispersive solvent, phase ratio, temperature, extraction and centrifugation time, were investigated thoroughly and optimized. The linear range was 20?C2,000 ng L?1 except for acenaphthylene (Acy) at 10?C2,000 ng L?1 and phenanthrene (Phe), fluoranthene (Flu) and pyrene (Py) all at 5?C2,000 ng L?1. Enrichment factors (EFs) ranging from 722 to 8,133 were obtained, achieving limits of detection at 1.0?C10.0 ng L?1. The method attained good precision (relative standard deviation, RSD) from 3.4 to 14.2% for spiked 50 ng L?1 individual PAHs standards. Method recoveries were in the range 87?C124% and 70?C127% for spiked samples from simulated seawater and beach seawater, respectively. The proposed USA-DLLME helped to obtain about 1.1?C10 times higher EFs in a minimum amount of solvent and in less time than traditional DLLME.  相似文献   

17.
The complexes formed between copper and thiram and between mercury and thiram have been electrochemically (voltammetrically) investigated in the present work. Their structure was confirmed using electrospray ionization mass spectrometry. Due to formation of the complex between copper (from copper solid amalgam electrode) and thiram, the concentration of this pesticide can be determined. The voltammetric behavior of thiram was investigated at polished (p-CuSAE) and mercury meniscus modified (m-CuSAE) copper solid amalgam electrodes (inner diameter 1.5 mm) by differential pulse voltammetry (DPV) and by direct current voltammetry (DCV). Optimum conditions for DPV determination of thiram were found in Britton–Robinson buffer. The reaction mechanism was investigated using DCV and elimination voltammetry with linear scan. DPV with optimized parameters was applied for determination of thiram in analyzed solutions. The limits of detection were calculated as 16 nmol?L?1 (t acc?=?100 s) for m-CuSAE and 23 nmol?L?1 (t acc?=?60 s) for p-CuSAE. The proposed method was successfully applied for thiram determination in real sample solutions.  相似文献   

18.
A carbon screen‐printed electrode modified in‐situ with lead film (PbF‐SPCE) was applied for the adsorptive stripping voltammetric determination of Co(II) in the form of a complex with 1,2‐cyclohexanedione dioxime. Lead film was electrochemically deposited in situ on SPCE from a 0.2 M ammonia buffer solution (pH 8.7) containing 5 ? 10?5 M Pb(NO3)2 and 5 ? 10?5 M nioxime. Due to the very low LOD (0.003 µgL?1, i.e., 0.05 nmol L?1 Co(II); tacc=120s), the developed procedure could be rated among the most sensitive methods employing SPEs. The Ni(II) signal was significantly lower than the Co(II) one and the separation of Ni(II) and Co(II) peaks was even better at the PbF‐SPCE than at the hanging mercury drop electrode.  相似文献   

19.
Voltammetric procedures for trace metals analysis in polluted natural waters using homemade bare gold-disk microelectrodes of 25- and 125-μm diameters have been determined. In filtered seawater samples, square wave anodic stripping voltammetry (SWASV) with a frequency of 25 Hz is applied for analysis, whereas in unfiltered contaminated river samples, differential pulse anodic stripping voltammetry (DPASV) gave more reliable results. The peak potentials of the determined trace metals are shifted to more positive values compared to mercury drop or mercury-coated electrodes, with Zn always displaying 2 peaks, and Pb and Cd inversing their positions. For a deposition step of 120 s at ?1.1 V, without stirring, the 25-μm gold-disk microelectrode has a linear response for Cd, Cu, Mn, Pb and Zn from 0.2 μg L?1 (1 μg L?1 for Mn) to 20 μg L?1 (30 μg L?1 for Zn, Pb and 80 μg L?1 for Mn). Under the same analytical conditions, the 125-μm gold-disk microelectrode shows linear behaviour for Cd, Cu, Pb and Zn from 1 μg L?1 (5 μg L?1 for Cd) to 100 μg L?1 (200 μg L?1 for Pb). The sensitivity of the 25-μm electrode varied for different analytes from 0.23 (±0.5%, Mn) to 4.83 (±0.9%, Pb) nA L μmol?1, and sensitivity of the 125-μm electrode varied from 1.48 (±0.7%, Zn) to 58.53 (±1.1%, Pb  nA L μmol?1. These microelectrodes have been validated for natural sample analysis by use in an on-site system to monitor Cu, Pb and Zn labile concentrations in the Deûle River (France), polluted by industrial activities. First results obtained on sediment core issued from the same location have shown the ability of this type of microelectrode for in situ measurements of Pb and Mn concentrations in anoxic sediments.   相似文献   

20.
Molybdenum(VI) in seawater is determined by means of potentiostatic adsorption of the 8-quinolinol complex onto a mercury film electrode at ?0.2 V vs. SCE and subsequent reduction of the complex by means of constant-current stripping in 5 M calcium chloride medium with a fully automated stripping analyzer. A single stripping peak at –0.42 V vs. SCE was obtained. The molybdenum(VI) concentration in reference seawater NASS-1, with a certified value of 11.5 ± 1.9 μg 1?1, was found to be 8.9 ± 1.3 μg 1?1 (n = 10).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号