首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The effect of the SnO(2) nanoparticles (SNPs) on the behaviour of voltammetric carbon paste electrodes were studied for possible use of this material in biosensor development. The electrochemical behaviour of SNP modified carbon paste electrodes (CPE) was first investigated by using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. The performance of the SNP modified electrodes were compared to those of unmodified ones and the parameters affecting the response of the modified electrode were optimized. The SNP modified electrodes were then tested for the electrochemical sensing of DNA purine base adenine to explore their further development in biosensor applications.  相似文献   

2.
《Electroanalysis》2005,17(23):2182-2189
An electrochemical DNA biosensor was fabricated by immobilizing DNA probe on aluminum ion films that were electrodeposited on the surface of the stearic acid‐modified carbon paste electrode (CPE). DNA immobilization and hybridization were characterized with cyclic voltammetry (CV) by using methylene blue (MB) as indicator. MB has a couple of well‐defined voltammetric redox peaks at the CPE. The currents of redox peaks of MB decreased after depositing aluminum ion films on the CPE (Al(III)/CPE) and increased dramatically after immobilizing DNA probe (ssDNA/Al(III)/CPE). Hybridization of DNA probe led to a marked decrease of the peak currents of MB, which can be used to detect the target single‐stranded DNA. The conditions for the preparation of Al(III)/CPE, and DNA immobilization and hybridization were optimized. The specific sequences related to bar transgene in the transgenic corn and the PCR amplification of CP4 epsps gene from the sample of transgenic roundup ready soybean were detected by differential pulse voltammetry (DPV) with this new electrochemical DNA biosensor. The difference between the peak currents of MB at ssDNA/Al(III)/CPE and that at hybridization DNA modified electrode (dsDNA/Al(III)/CPE) was applied to determine the specific sequence related to the target bar gene with the dynamic range comprised between 1.0×10?7 mol/L to 1.0×10?4 mol/L. A detection limit of 2.25×10?8 mol/L of oligonucleotides can be estimated.  相似文献   

3.
Development of electrochemical DNA hybridization biosensors based on carbon paste electrode (CPE) and gold nanoparticle modified carbon paste electrode (NGMCPE) as transducers and ethyl green (EG) as a new electroactive label is described. Electrochemical impedance spectroscopy and cyclic voltammetry techniques were applied for the investigation and comparison of bare CPE and NGMCPE surfaces. Our voltammetric and spectroscopic studies showed gold nanoparticles are enable to facilitate electron transfer between the accumulated label on DNA probe modified electrode and electrode surface and enhance the electrical signals and lead to an improved detection limit. The immobilization of a 15‐mer single strand oligonucleotide probe on the working electrodes and hybridization event between the probe and its complementary sequence as a target were investigated by differential pulse voltammetry (DPV) responses of the EG accumulated on the electrodes. The effects of some experimental variables on the performance of the biosensors were investigated and optimum conditions were suggested. The selectivity of the biosensors was studied using some non‐complementary oligonucleotides. Finally the detection limits were calculated as 1.35×10?10 mol/L and 5.16×10?11 mol/L on the CPE and NEGCPE, respectively. In addition, the biosensors exhibited a good selectivity, reproducibility and stability for the determination of DNA sequences.  相似文献   

4.
A carbon paste electrode (CPE) modified with Nafion, Graphene oxide and zeolite has been prepared and characterized, and the resulting Nafion/Graphene oxide/Zeolite modified carbon paste electrode (N/G/Z/MCPE) has been applied to the electrochemical detection of Moxifloxacin hydrochloride (MOXI). It exhibited a good electrocatalytic activity in phosphate buffer (optimum at pH 7.4), as pointed out by cyclic voltammetry (CV), and N/G/Z/MCPE can be exploited for MOXI detection by chronoamperometry, electrochemical impedance spectroscopy and differential pulse voltammetry. This latter was the most sensitive one and gave rise to a linear calibration curve in the 0.04 to 250 μM concentration range, with limits of detection and qualification estimated at 1.0 nM and 3.3 nM, respectively. Contrary to previous electrochemical sensors for MOXI (e. g., CPE modified with metal nanoparticles), this new sensor can be used for multiple successive analyses without needing to refresh its surface.  相似文献   

5.
Zhang Y  Zeng GM  Tang L  Li YP  Chen LJ  Pang Y  Li Z  Feng CL  Huang GH 《The Analyst》2011,136(20):4204-4210
This work developed a relatively inexpensive and layers-film construction electrochemical sensor for DNA recognition and its performance was investigated. The Fe(3)O(4) magnetic nanoparticles-cysteine were immobilized on the carbon paste electrode (CPE) surface using magnetic force. Multiwalled carbon nanotubes (MWCNTs), gold nanoparticles (GNPs), and chitosan (Chi) were used successively to coat on the electrode surface. The thiolated capture probe was assembled and competitively hybridized with the target nucleic acid and biotinylated response probe. The electrochemical behavior was analyzed by cyclic voltammetry and electrochemical impedance spectroscopy. In addition, the sensor performance was also analyzed by introducing the notion of detection efficiency. The experimental results showed that although the electron transfer capability of the CPE is less strong than that of a metal electrode used in the DNA sensor, the materials modified on the CPE could significantly improve the performance. A detection limit of 1 nM of target DNA and a sensitivity of 2.707 × 10(3) mA M(-1) cm(-2) were obtained. Although the resulting detection limit was not remarkable, further experiments could improve it.  相似文献   

6.
运用一种新型的化学引发-电聚合方式将中性红膜固定到碳糊电极表面,制备出聚中性红薄膜修饰碳糊电极(PNR/CPE)。利用循环伏安法(CV)和交流阻抗谱(EIS)对修饰电极的电化学性能进行研究,借助于扫描电子显微镜(SEM)对修饰电极表面进行表征,并采用红外吸收光谱法(IR)和紫外可见吸收光谱法(UV-Vis)对PNR薄膜结构进行测试。结果表明,中性红成功地固定在碳糊电极表面,修饰电极的表面呈现特定的立体化结构,表面的电活性位点增多,电催化性能增大。在优化条件下,将该电极应用于鲱鱼精DNA(hs DNA)的检测,PNR电极上出现了1对较强的氧化还原峰,峰电流与其浓度在1.0×10~(-6)~8.0×10~(-5)mol/L范围内呈良好的线性关系,检出限为1.0×10~(-7)mol/L。  相似文献   

7.
以液体石蜡和硅油为混合粘合剂,与石墨粉混合制备了碳糊电极基底电极,将石墨烯/十二烷基硫酸钠复合物修饰在基底碳糊电极上,得到了基于石墨烯复合物的新型修饰碳糊电极。应用扫描电镜和循环伏安法分别研究了该电极的表面特性和电化学性质,结果表明,石墨烯和十二烷基硫酸钠修饰的碳糊电极增大了比表面积,有利于电子传递。在pH 3.0的HAc-NaAc缓冲溶液中,该修饰碳糊电极对氯霉素具有良好的电化学响应,氧化峰电位为0.194 V,氧化峰电流是基底碳糊电极的10倍。在最优实验条件下,该氧化峰电流与氯霉素的浓度在1.0×10~(-8)~5.0×10~(-4)mol/L范围内呈良好的线性关系,检出限为5.0×10~(-9)mol/L。该方法简便,重现性及选择性好,用于测定氯霉素滴眼液和虾中氯霉素残留,结果满意。  相似文献   

8.
In this study we report the development of an amperometric cholesterol biosensor based on cholesterol oxidase from Pseudomonas sp. and catalase immobilized in carbon paste electrode (CPE) modified with multiwall carbon nanotubes (MWCNT) and ionic liquid (IL). The working electrode (CPE/MWCNT-IL/Microorganism (MO)-Catalase) was characterized by impedance spectroscopy and cyclic voltammetry at different stages of its construction. This proposed cholesterol biosensor performed linear relationship in the range of 5–600 μM with a low detection limit of 1.52 μM. The biosensor showed good sensitivity and high selectivity and it was successfully applied for the measurement of cholesterol levels in lyophilized serum samples.  相似文献   

9.
In this paper, nano‐gold modified carbon paste electrode (NGMCPE) was employed to develop an electrochemical DNA hybridization biosensor. The proposed sensor was made up by immobilization of 15‐mer single stranded oligonucleotide probe for detection of target DNA. Hybridization detection relies on the alternation in guanine oxidation signal following hybridization of the probe with complementary genomic DNA. The guanine oxidation was monitored using differential pulse voltammetry (DPV). Different factors such as activation potential, activation time and probe immobilization conditions were optimized. The selectivity of the sensor was investigated by non‐complementary oligonucleotides. Diagnostic performance of the biosensor was described and the detection limit was found 1.9 × 10?13 M at the NGMCPE surface. All of the investigations were performed in both CPE and NGMCPE and finally their results were compared.  相似文献   

10.
研究了硫脲(Thiourea,Tu)在10-甲基吩噻嗪修饰碳糊电极(MPT/CPE)上的电催化氧化行为.结果表明,Tu在裸碳糊电极(CPE)上的直接电化学氧化过程十分迟缓,MPT/CPE对Tu的电化学氧化具有良好的催化作用.用计时电流法(CA)测定了Tu在MPT/CPE上的电极过程动力学参数,测得电荷传递系数α=0.61,电催化氧化反应的速率常数k=(1.96±0.10)×104(mol/L)-1·s-1.用方渡伏安法(SWV)测得催化氧化峰电流与Tu浓度在1.0×10-6~8.0×10-3mol/L范围内呈良好的线性关系,线性回归方程为,Ips(μA)=10.836c(10-3mol/L)+5.326,R=0.9984,检出限为2.2×10-7mol/L(S/N=3).方法可用于Tu的电化学法测定.  相似文献   

11.
This work describes the promising activity of silver nanoparticles on the surface of a poly(2-amino diphenylamine) modified carbon paste electrode (CPE) towards formaldehyde oxidation. Electrodeposition of the conducting polymer film on the CPE was carried out using consecutive cyclic voltammetry in an aqueous solution of 2-aminodiphenylamine and HCl. Nitrogen groups in the polymer backbone had a Ag ion accumulating effect, allowing Ag nanoparticles to be electrochemically deposited on the surface of the electrode. The electrochemical and morphological characteristics of the modified electrode were investigated. The electro-oxidation of formaldehyde on the surface of electrode was studied using cyclic voltammetry and chronoamperometry in aqueous solution of 0.1 mol/L NaOH. The electro-oxidation onset potential was found to be around -0.4 V, which is unique in the literature. The effect of different concentrations of formaldehyde on the electrocatalytic activity of the modified electrode was investigated. Finally, the diffusion coefficient of formaldehyde in alkaline media was calculated to be 0.47 × 10-6 cm2/s using chronoamperometry.  相似文献   

12.
Described here are the chronocoulometric and voltammetric parameters for methylene blue [3,7-bis(dimethylamino)phenothiazin-5-ium chloride, MB] on binding to DNA at carbon paste electrode (CPE) surface. MB, which interacts with the immobilized calf thymus DNA was detected by using single stranded DNA modified CPE (ssDNA modified CPE), bare CPE and double stranded DNA modified CPE (dsDNA modified CPE) in combination with chronocoulometry and differential pulse voltammetry (DPV) techniques. The effect of ionic strength to the behavior of MB with dsDNA and ssDNA was also studied by means of voltammetry. These results demonstrated that MB could be used as an effective electroactive hybridization indicator for DNA biosensors. Performance characteristics of the sensor are described, along with future prospects.  相似文献   

13.
DNA biosensors based on nucleic acid hybridization processes are rapidly being developed towards the goal of rapid and inexpensive diagnosis of genetic and infectious diseases. Electrochemical transducers are often being used for detecting the DNA hybridization event, due to their high sensitivity, small dimensions, low cost, and compatibility with microfabrication technology. In this study, an electrochemical biosensor for the voltammetric detection of DNA sequences related to the Hepatitis B virus (HBV) and TT virus (TTV) from polymerase chain reaction (PCR) amplified real samples is described for the first time. The biosensor relies on the immobilization of the 21- or 24-mer single stranded oligonucleotides (probe) related to the HBV and TTV sequences and hybridization of these oligonucleotides with their complementary sequences (target) at carbon paste electrode (CPE). The extent of hybridization between the probe and target sequences was determined by using square wave voltammetry (SWV) with moving average baseline correction and methylene blue (MB) as the hybridization indicator. As a result of the interaction between MB and the bound guanine bases of hybrid at CPE surface, the MB signal decreased, when it was compared with the MB signal, which was observed with probe modified CPE. The difference between the MB signals, obtained from the hybrid modified and the probe modified CPE is used to detect the DNA sequences of the infectious diseases from PCR amplified real samples. Numerous factors affecting the target hybridization and indicator binding reactions are optimized to maximize the sensitivity.  相似文献   

14.
将石墨粉、固体石蜡和硬脂酸按一定比例混合制得表面富含羧基的碳糊电极,然后在电极表面组装荷正电的铝离子膜。在硬脂酸铝离子膜上进行DNA探针的固定和与目标基因的杂交。以亚甲蓝为杂交指示剂,用循环伏安法优化了DNA的固定和杂交条件。应用该电化学生物传感器以微分脉冲伏安法对转基因玉米外源BAR基因片段进行了检测,结果令人满意。  相似文献   

15.
The homogeneous electrocatalytic oxidation of hydrazine(HZ) has been studied by indigocarmine(IND) as a mediator at the surface of TiO2 nanoparticles modified carbon paste electrode(TNMCPE).Cyclic voltammetry was used to study the electrochemical behavior of IND at different scan rates.The voltammetric response of the modified electrode was linear against the concentration of HZ in the ranges of 3.0×l0-8-7.0×106 mol/L with differential pulse voltammetry method.The detection limit(3σ) was determined as 27.3 nmol/L.To evaluate the applicability of the proposed method to real samples,the modified CPE was applied to the determination of HZ in water samples.  相似文献   

16.
In this study, we fabricated an effective and sensitive DNA biosensor based on flower-like Pt/NiCo2O4 modified carbon paste electrode (FL-Pt/NiCo2O4/CPE) for detection of pramipexole (PPX). Spectrophotometry, differential pulse voltammetry (DPV) and docking methods were employed to evaluate the interaction of DNA-PPX. Moreover, the DPV technique was chosen to monitor the electrochemical response of guanine on the DNA biosensor. The relationship between the concentration of PPX and the oxidation signal of guanine was linear in the range of 0.4 to 310.0 μM and a limit of detection (LOD) of 0.09 μM was calculated.  相似文献   

17.
《Analytical letters》2012,45(13):2402-2411
Abstract

Porous pseudo-carbon paste electrode (PPCPE) as a novel high-sensitive electrochemical biosensor was fabricated by mixing polymethyl methacrylate (PMMA) microspheres for use as the template, graphite powders for the filler, and pyrrole as the precursor of the polymer which acted as the paste. After the polymerization of pyrrole catalyzed by Fe3+, the PMMA microspheres were removed to form PPCPE. The pore size was determined by SEM observations, with diameters ranging from 2 to 5 µm. The anodic stripping voltammetry response of DNA indicated that the adsorption of oligonucleotide on PPCPE was enhanced. The PPCPE was easy to preserve and had a good reusability in comparison with that of a pure carbon paste electrode (CPE) and a carbon nanotube-modified carbon paste electrode (CNTPE). The detection limits of guanine and adenine were 20 nM and 8 nM, respectively.  相似文献   

18.
A carbon paste electrode (CPE) modified with ferrocene carboxylic acid (FcCA) and TiO2 nanoparticles was constructed by incorporating TiO2 nanoparticles and ferrocene carboxylic acid into the carbon paste matrix.The electrochemical behavior of captopril (CAP) at the surface of the modified electrode was investigated using electroanalytical methods.The modified electrode showed excellent electrocatalytic activity for the oxidation of CAP in aqueous solutions at physiological pH values.Cyclic voltammetric curves showed that the oxidation of CAP at the surface of the modified electrode reduced its overpotential by more than 290 mV.The modified electrode was used for detecting captopril using cyclic voltammetry and square wave voltammetry techniques.A calibration curve in the range of 0.03 to 2400μmol/L was obtained that had a detection limit of 0.0096 μmol/L (3σ) under the optimized conditions.The modified electrode was successfully used for the determination of captopril in pharmaceutical and biological samples.  相似文献   

19.
In this paper a molecular wire modified carbon paste electrode (MW‐CPE) was firstly prepared by mixing graphite powder with diphenylacetylene (DPA). Then a graphene (GR) and chitosan (CTS) composite film was further modified on the surface of MW‐CPE to receive the graphene functionalized electrode (CTS‐GR/MW‐CPE), which was used for the sensitive electrochemical detection of adenosine‐5′‐triphosphate (ATP). The CTS‐GR/MW‐CPE exhibited excellent electrochemical performance and the electrochemical behavior of ATP on the CTS‐GR/MW‐CPE was carefully studied by cyclic voltammetry with an irreversible oxidation peak appearing at 1.369 V (vs. SCE). The electrochemical parameters such as charge transfer coefficient (α) and electrode reaction standard rate constant (ks) were calculated with the results of 0.53 and 5.28×10?6 s?1, respectively. By using differential pulse voltammetry (DPV) as detection technique, the oxidation peak current showed good linear relationship with ATP concentration in the range from 1.0 nM to 700.0 µM with a detection limit of 0.342 nM (3σ). The common coexisting substances, such as uric acid, ascorbic acid and guanosine‐5′‐triphosphate (GTP), showed no interferences and the modified electrode was successfully applied to injection sample detection.  相似文献   

20.
A new selective carbon paste electrode (CPE), was applied as an electrochemical sensor for the detection of norepinephrine (NOE). The sensor was modified with 6‐amino‐4‐(3,4‐dihydroxyphenyl)‐3‐methyl‐1,4‐dihydropyrano[2,3‐c],pyrazole‐5‐carbonitrile (ADPC) assisted Fe2O3@CeO2 coreshell nanoparticles (CNs) synthesized by simple method. To identify the redox properties of the modified electrode, and to examine its electrochemical properties, cyclic voltammetry (CV), chronoamperometry and differential pulse voltammetry (DPV) were conducted. Through electrochemical investigations, the coefficient of electron transfer between ADPC and the CNs/CPE (i. e. carbon paste electrode which was modified with CNs), the apparent charge transfer rate constant (ks), and the diffusion coefficient (D) were calculated. The NOE oxidation occurred at the optimum pH of 7.0 and a potential that was about 235 mV less positive than that of the unmodified carbon paste electrode. The interaction between the two metals in the Fe2O3@CeO2 coreshell led to an increase in the surface area and, consequently a sharp increase in the current. The differential pulse voltammogram of NOE showed two linear dynamic ranges an excellent detection limit (3σ) of 40 nM. In addition, NOE, AC and Trp were simultaneously determined at the modified electrode. Finally, NOE was quantitated in a number of real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏