首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

New stationary phases for HPLC are obtained via layer-by-layer deposition of polyelectrolytes and studied: (1) silica gel modified layer-by-layer with 6,10-ionene and dextran sulfate (Sorbent 1); (2) silica gel twice subjected to the above modification (Sorbent 2); and (3) silica gel modified with 6,10-ionene, gold nanoparticles, and dextran sulfate (Sorbent 3). The effect the content of the organic solvent in the mobile phase and the concentration and pH of the buffer solution have on the chromatographic behavior of several pharmacologically active nitrogen-containing compounds is studied. The sorbents are stable during the process and allow the effective separation of beta-blockers, calcium channel blockers, alpha-agonists, and antihistamines. A mixture of caffeine, nadolol, tetrahydrozoline, pindolol, orphenadrine, doxylamine, carbinoxamine, and chlorphenamine is separated in 6.5 min on the silica gel modified with 6,10-ionene, gold nanoparticles, and dextran sulfate.

  相似文献   

2.
In this work, a CE method with bare gold nanorods (GNRs) based pseudostationary phase was developed and applied for the separation of chondroitin sulfate (CS) isomers, CS, and dermatan sulfate (DS). The separation efficiency was investigated by varying the experimental parameters such as concentration and pH of the BGE, separation voltage, internal diameter of capillary, different size, and morphology of gold nanomaterials. Results showed that different size and morphology of gold nanomaterials had different effects on the separation of CS and DS. The best separation of CS and DS was achieved in the BGE composed of aqueous 150 mmol/L (mM) ethylenediamine + 20 mM sodium dihydrogen phosphate + 30% v/v GNRs, pH 4.5, at the separation voltage of ?10 kV. Capillary was 59.2 cm in length (effective length 49 cm), 50 μm id capillary thermostated at 25°C. CE with bare GNRs used as pseudostationary phase was shown to be a suitable technique for the separation of CS and DS mixtures with wider peaks. RSD of migration time and peak area of CS and DS were 0.13, 0.14 and 0.86, 1.07%, respectively.  相似文献   

3.
Adsorbents for hydrophilic chromatography: silica layer-by-layer modified with 6,10-ionene and sodium lignosulfonate (Sorbent-1), and silica modified with chitosan and sodium lignosulfonate (Sorbent-2) have been investigated. The influence of the nature of polycation used for the synthesis of adsorbents and the composition of the mobile phase on the retention and separation of phenol carboxylic acids have been studied. It was found that the retention of organic acids and the selectivity of their separation are higher on Sorbent-1. The possibility of the isocratic separation of a mixture of caffeine, sorbic, benzoic, vanillic, gallic, salicylic, sinapic, ferulic, p-cumaric, and caffeic acids in 30 min on a column filled with Sorbent-1 was demonstrated.  相似文献   

4.
Recently, oversulfated chondroitin sulfate (OSCS) present in certain lots of heparin was identified as the toxic contaminant responsible for severe side effects following intravenous heparin administration. The United States Pharmacopeia (USP) and European Pharmacopeia (Eur.Ph.) announced an immediate revision of their monographs for heparin sodium by adding two US Food and Drugs Administration-recommended tests for OSCS based on nuclear magnetic resonance and capillary electrophoresis (CE). However, the proposed CE method provides only partial separation of the OSCS contaminant from heparin, thereby hindering appropriate impurity profiling. Here we present an improved CE method that is especially useful for the reliable quantification of OSCS in heparin samples, but also allows determination of the common impurity dermatan sulfate (DS). Parameters such as type and concentration of background electrolyte, capillary temperature, sample concentration and injection volume were investigated and optimized. Enhancement of the OSCS–heparin separation was achieved by using high concentrations of Tris phosphate (pH 3.0) as background electrolyte. High currents and excessive Joule heating were prevented by employing fused-silica capillaries with an internal diameter of 25 μm. Good separations of OSCS, heparin and DS are obtained within 17 min. The method permits injection of relatively high heparin concentrations (up to 50 mg/ml) and large sample volumes (up to 5% of the capillary volume) allowing OSCS and DS determination in heparin down to the 0.05% and 0.5% (w/w) level, respectively. The CE method is shown to be repeatable and linear (R2 > 0.99) for OSCS, heparin and DS. CE analyses of OSCS-contaminated heparin samples and different heparin standards further demonstrate the utility of the method.  相似文献   

5.
Kelly T  Doble P  Dawson M 《Electrophoresis》2007,28(19):3566-3569
The utilization of dynamic doubly coated capillaries for a fast separation of methadone and its two major metabolites, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and 2-ethyl-5-methyl-3,3-diphenyl-1-pyrroline (EMDP) was investigated. The coated capillaries were prepared using a polycation of poly(diallyldimethylammonium chloride) and a polyanion of dextran sulfate. A fast achiral separation was developed using the coated capillaries with a BGE of 100 mM phosphate buffer at pH 2.6. Complete achiral separation of methadone, EDDP and EMDP was achieved, with migration times of approximately 4 min. The method offers considerable advantages with respect to BGE simplicity and analysis time compared to previously published CE methods for methadone and its related analytes.  相似文献   

6.
The usefulness of a noncovalent, positively charged capillary coating for the efficient analysis of intact basic proteins with CE was studied. Capillaries were coated by subsequent flushing with solutions of 10% w/v Polybrene (PB), 3% w/v dextran sulfate (DS), and again 10% w/v PB. Coating characterization studies showed that stable coatings could be produced which exhibited a pH‐independent and highly reproducible EOF. The PB–DS–PB coating was evaluated with Tris phosphate BGEs of various pH using the four basic model proteins: α‐chymotrypsinogen A, ribonuclease A, cytochrome c, and lysozyme. Typical migration time RSDs for the proteins were less than 0.85%, and apparent plate numbers were above 125 000 using a capillary length of 40 cm. The high separation efficiency allowed detection of several minor impurities in the model proteins. Using a BGE of medium pH, the CE system with triple‐layer coating appeared to be useful for the repeatable profiling of recombinant humanized mouse monoclonal immunoglobulin G1 showing a characteristic pattern of glycoforms. The CE system was also applied to the characterization of two llama antibodies, which were produced in Saccharomyces cerevisiae, revealing the presence of a side product in one of the antibodies. The high migration time stability allowed the reliable determination of antibody–antigen binding by monitoring migration time shifts. Finally, the feasibility of using the PB–DS–PB coated capillaries for CE with mass spectrometric detection was shown by the characterization of the impure llama antibody sample.  相似文献   

7.
This paper demonstrates that capillary electrophoresis (CE) can be employed for characterizing the sizes of nanometer-scale gold particles. We characterized the gold nanoparticles by effecting CE separation using a buffer of SDS (70 mM) and 3-cyclohexylamino-1-propanesulfonic acid (CAPS; 10 mM) at pH 11.0 and an applied voltage of 18 kV and obtained a linear relationship (R2 > 0.99) between electrophoretic mobilities and size for nanoparticles whose diameters fall in the regime from 5.0 ± 0.5 to 41.2 ± 3.3 nm; the relative standard deviations of these electrophoretic mobilities are <0.8%. We evaluated the feasibility of employing these separation conditions for the size characterization by of gold nanoparticle samples that were synthesized by a rapid microwave heating method. We confirmed that this CE method is a valid one for size characterization by comparing the results obtained by CE with those provided by scanning electron microscopy (SEM); a good correlation exists between these two techniques. Our results demonstrate that CE can be employed to accelerate the analysis of the sizes of nanomaterials.  相似文献   

8.
Yu B  Cong H  Liu H  Li Y  Liu F 《Journal of separation science》2005,28(17):2390-2400
In this article, a series of ionene polymers were synthesized and used to coat fused-silica capillaries for the separation of recombinant and urinary human erythropoietin (rhEPO and uEPO) standards by CE. The influence of the charge density of coatings on the separation of rhEPO and uEPO glycoforms was investigated. Then, we further studied the method for fast separation and detection of rhEPO and uEPO standards by CE-ESI-MS. The influence of several CE and MS operating parameters, such as the concentration of CE running buffer, applied external pressure, and the composition and flow rate of sheath liquid on CE-ESI-MS was studied. The results demonstrated that when the capillary was permanently coated with 6,6-ionene and the pH value of acetic acid-ammonium acetate running buffer was 4.80 and 5.50, respectively, a significantly reproducible separation was achieved for rhEPO and uEPO glycoforms. In the online CE-ESI-MS experiments, we not only achieved the online MS signal of uEPO, but also obtained baseline separation of three major rhEPO glycoforms successfully and reproducibly on the 6,6-ionene-coated capillaries. Furthermore, the standard mixture of rhEPO and uEPO was separated, and two incompletely resolved peaks that were identified to be rhEPO and uEPO by the unique MS "fingerprint" were obtained. Additionally, the molecular weight of rhEPO and uEPO were verified and compared to the results by MALDI-TOF-MS. It can be concluded that, in contrast to other indirect methods, the online CE-ESI-MS technique with the combination of the advantages of both CE and MS shows great potential for the separation and detection of rhEPO doping directly in competitive sports.  相似文献   

9.
We report the separation of polycyclic aromatic hydrocarbons (PAHs) using 0.1% poly(ethylene oxide) (PEO) in micellar electrokinetic chromatography (MEKC). In the presence of PEO, adsorption of PAHs on the capillary wall was reduced, leading to better resolution and reproducibility. Effects of tetrapentylammonium iodide (TPAI), dextran sulfate (DS), methanol, and sodium lauryl sulfate (SDS) on the separation of PAHs were elucidated. In terms of resolution and speed, DS, compared to TPAI, is a better additive for separation of PAHs. When using 0.1% PEO solution containing 45% methanol, 50 mM SDS, and 0.02% DS, separation of 10 PAHs containing 2 to 5 benzene rings was accomplished in less than 12 min at 15 kV in a commercial CE system. The method has also been tested for separating seven PAHs with high quantum yields when excited at 325 nm using a He-Cd laser. Unfortunately, separation of the seven PAHs was not achieved and sensitivity diminished under the same conditions. To optimize sensitivity, resolution and speed, a stepwise technique in MEKC has been proposed. The seven PAHs were resolved in 35 min at 15 kV when separation was performed in 0.1% PEO solution containing 35 mM SDS, 40% methanol and 0.02% DS for 2 min, and subsequently in 0.1% PEO solution containing 20 mM SDS, 50% methanol, and 0.02% DS.  相似文献   

10.
This paper describes employing capillary electrophoresis (CE) for the separation of gold colloids in nanometer-size regimes. Adding sodium dodecylsulfate (SDS) surfactant to the running buffer enhances the capability of CE to separate gold nanoparticles. We found that the optimized separation conditions involved SDS (70 mM), 3-cyclohexylamoniuopropanesulfonic acid (CAPS) buffer (10 mM), pH 10.0, and an applied voltage of 20 kV. We propose that the charged surfactants associate onto the surface of the gold nanoparticles and cause a change in the charge-to-size ratio of gold nanoparticle, which is a function of the surface area of nanoparticle and the surfactant concentration of running electrolyte. At high concentrations of the surfactant in the running electrolyte—i.e., when the surface of the gold nanoparticles is fully occupied with SDS—a linear relationship exists between the electrophoretic mobility and nanoparticles having diameters ranging from 5.3 to 38 nm. Based on the results of separating the 5.3 and 19 nm nanoparticles, we estimate that the size resolution (Rs=1.0) is 5.0 nm. The relative standard deviations of the electrophoretic mobilities of the 5.3 and 19 nm gold nanoparticles are 0.97 and 0.54%, respectively.  相似文献   

11.
Nanoparticles combining a hydrophobically modified dextran core and a polysaccharide surface coverage were elaborated. Their suitability for applications like drug delivery was evaluated. The selected polysaccharide, dextran, was chemically modified by the covalent attachment of hydrocarbon groups (aliphatic or aromatic) via the formation of ether links. According to the extent of modification, either water-soluble or water-insoluble dextran derivatives were obtained. The latter exhibited solubility in organic solvents like tetrahydrofuran or dichloromethane saturated with water. Water-soluble dextran derivatives were used as polymeric surfactants for the control of nanoparticles surface characteristics. Nanoparticles were prepared either by o/w emulsion or solvent-diffusion methods. The size and surface properties of dextran nanoparticles were correlated to processing conditions. The stability of colloidal suspensions was examined as a function of ionic strength and related to the particle surface characteristics. The redispersability of freeze-dried suspensions without the addition of cryoprotectant was demonstrated. Finally, the degradability of modified dextrans was compared to that of starting dextran, after enzymatic hydrolysis in the presence of dextranase.  相似文献   

12.
Analyte–wall interaction is a significant problem in capillary electrophoresis (CE) as it may compromise separation efficiencies and migration time repeatability. In CE, self-assembled polyelectrolyte multilayer films of Polybrene (PB) and dextran sulfate (DS) or poly(vinylsulfonic acid) (PVS) have been used to coat the capillary inner wall and thereby prevent analyte adsorption. In this study, atomic force microscopy (AFM) was employed to investigate the layer thickness and surface morphology of monolayer (PB), bilayer, (PB-DS and PB-PVS), and trilayer (PB-DS-PB and PB-PVS-PB) coatings on glass surfaces. AFM nanoshaving experiments providing height distributions demonstrated that the coating procedures led to average layer thicknesses between 1 nm (PB) and 5 nm (PB-DS-PB), suggesting the individual polyelectrolytes adhere flat on the silica surface. Investigation of the surface morphology of the different coatings by AFM revealed that the PB coating does not completely cover the silica surface, whereas full coverage was observed for the trilayer coatings. The DS-containing coatings appeared on average 1 nm thicker than the corresponding PVS-containing coatings, which could be attributed to the molecular structure of the anionic polymers applied. Upon exposure to the basic protein cytochrome c, AFM measurements showed an increase of the layer thickness for bare (3.1 nm) and PB-DS-coated (4.6 nm) silica, indicating substantial protein adsorption. In contrast, a very small or no increase of the layer thickness was observed for the PB and PB-DS-PB coatings, demonstrating their effectiveness against protein adsorption. The AFM results are consistent with earlier obtained CE data obtained for proteins using the same polyelectrolyte coatings.  相似文献   

13.
Liu FK 《Analytica chimica acta》2011,694(1-2):167-173
In this study, gold nanoparticles (Au NPs) were separated using the reversed electrode polarity stacking mode (REPSM) of a capillary electrophoresis (CE) system for on-line enhancement prior to performing surfactant-modified CE separation. Under optimized conditions [running electrolyte buffer, sodium dodecyl sulfate (70 mM) and 3-cyclohexylamino-1-propanesulfonic acid (10 mM) at pH 10.0; applied voltage, 20 kV; operating temperature, 25°C; REPSM strategy for sample on-line concentration; REPSM applied prior to initializing separation], two parameters were varied to further enhance the concentration and separation of the Au NPs: (i) the rate of polarity switching (from -20 to +20 kV) between the REPSM and surfactant-modified CE separation modes and (ii) the length of the capillary column. At a polarity switching rate of 1333 kV min(-1) and a column length of ca. 83.5 cm, the resolution of the separation of a mixture of 5.3- and 40.1-nm Au NPs was greater than 19; in addition, the numbers of theoretical plates for the 5.3- and 40.1-nm-diameter Au NPs were greater than 15,000 and up to 1.15×10(7), respectively-the latter being extremely high. Thus, this CE-based method for separating Au NPs provided high performance in terms of separation resolution and the number of theoretical plates, both of which were improved by greater than fivefold relative to those published previously. Notably, the sensitivity enhancement factors for the 5.3- and 40.1-nm-diameter Au NPs were improved (by ca. 20- and 500-fold, respectively) relative to those obtained using conventional surfactant-modified CE separation.  相似文献   

14.
Hamer M  Yone A  Rezzano I 《Electrophoresis》2012,33(2):334-339
We report a new method of immobilization of gold nanoparticles (AuNPs) on a fused-silica capillary through covalent binding. The resulting modified capillary was applied to electrophoretic systems to improve the efficiency of separation and the selectivity of selected solutes. The immobilization of AuNPs on the capillary wall was performed in a very simple and fast way without requiring heating. The surface features of an AuNP-coated capillary column were determined using the scanning electron microscopy. The chromatographic properties of AuNP-coated capillaries were investigated through variation of the buffer pH and separation voltage. Effective separations of synthetic peptides mixture were obtained on the AuNP-coated capillaries. The method shows a remarkable stability since it was reused about 900 times. The capacity factor was duplicated. Therefore, this modification is stable and can be applied to different separation purposes. A complex mixture of tryptic peptide fragments of HSA was analyzed in both the bare- and the AuNP-coated capillaries. Better electrophoretic peptide profile was observed when using the AuNP-coated capillary.  相似文献   

15.
Zhang J  Horváth C 《Electrophoresis》2003,24(1-2):115-120
A simple coating technique by using uncross-linked dextran has been developed for fused-silica capillaries to be used in capillary electrophoresis of basic proteins. The capillaries were first silanized with a heterobifunctional silane (gamma-aminopropyltriethoxylsilane), which served as a coupling agent between the capillary inner wall and the polysaccharide coating. Dextran of high molecular mass (about 70 kDa) was activated with 1,1'-carbonyldiimidazole. Then the activated dextran was coupled to the primary amino groups that were anchored onto the inner wall of the silanized capillaries. The residual reactive groups on the dextran were further substituted by neutral functions in a coupling reaction with excess ethanolamine. By using dimethyl sulfoxide (DMSO) rather than aqueous buffer as the reaction medium, the extent of substitution was improved by minimizing the residual reactive groups at the surface. Since they are ionogenic, the electrosmotic flow in the system is relatively low. The chemically bound dextran coating showed good reproducibility and stability. In electrophoretic experiments basic proteins were separated with high efficiency by use of the dextran-coated fused-silica capillary columns. The main advantage of the method described here is that both polysaccharide activation and amine-coupling reactions were carried out under mild conditions at room temperature without catalysts. For this reason, the method is recommended to coat the inner wall of microfluidic separation channels which would not tolerate a harsh treatment.  相似文献   

16.
Rapid, precise, accurate, and reproducible methodology using capillary electrophoresis (CE) with dynamically coated capillaries for the analysis of heroin and its basic impurities and adulterants is presented. Highly selective determination of the above solutes is obtained by analyzing the same sample preparation by two CE methods. For the determination of heroin, its basic impurities and basic adulterants, dynamic coating of the capillary surface is accomplished using a commercially available reagent kit with an added cyclodextrin ((CD) polycation coating followed by polyanion coating with dimethyl-beta-cyclodextrin or hydroxypropyl-beta-cyclodextrin). The addition of a cyclodextrin to the run buffer significantly improves the separation of these solutes. Neutral, acidic, and weakly basic adulterants which migrate near or after t0 do not interfere with the more mobile basic solutes. The determination of neutral, acidic, and weakly basic adulterants in heroin is accomplished using a modification of the above commercially available reagent kit. After first coating with a polycation, a negative coating is obtained using a surfactant sodium dodecyl sulfate. Micellar electrokinetic chromatography (MEKC) with dynamically coated capillaries gives an excellent separation of the neutral, acidic, and weakly basic solutes, with considerably shorter run times compared to conventional MEKC. In addition for this system, most basic solutes in heroin have longer migration times than the uncharged and acidic compounds.  相似文献   

17.
An in-capillary electrode sheathless interface was applied to the capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) analysis of mixtures of small peptides, proteins, and tryptic digests of proteins. The effects of different experimental parameters on the performance of this CE/ESI-MS interface were studied. The distance of the in-capillary electrode from the CE outlet and the length of the electrode inside the capillary had no significant effects on the CE separation and ESI behavior under the experimental conditions used. However, significant enhancement of the sensitivity resulted from the use of narrower CE capillaries. Using a quadrupole mass spectrometer, an aminopropylsilane-coated capillary, and a wide scan mass-to-charge ratio range of 500–1400, detection limits of approximately 4, 1, and 0.6 fmol for cytochrome c and myoglobin were achieved for 75-, 50-, and 30-µm inner diameter capillaries, respectively. Approximately one order of magnitude lower detection limits were achieved under the multiple-ion monitoring mode. The application of the in-capillary electrode sheathless interface to real-world samples was demonstrated by CE/ESI-MS analysis of a human blood sample.  相似文献   

18.
A novel open-tubular capillary electrochromatography (OTCEC) column was prepared by immobilizing dodecanethiol gold nanoparticles on prederivatised fused-silica capillary columns with sol-gel technology. 3-Mercaptopropyl-trimethoxysilane (MPTMS) was selected as sol-gel precursor to develop a sol-gel layer on the inner wall of the capillary, prior to assembly of dodecanethiol gold nanoparticles onto the generated sol-gel layer through specific interaction between the gold nanoparticles and surface terminating thiol groups. The electrochromatographic behaviour of the sol-gel gold nanoparticle capillary was compared with a gold nanoparticle capillary prepared via MPTMS surface functionalisation, through variation of the percentage of the organic modifier, pH, and separation voltage. Efficient separation for a "reversed-phase" test mixture of thiourea, naphthalene, and biphenyl and for selected polycyclic aromatic hydrocarbons (PAHs) was obtained on the sol-gel based gold nanoparticle capillaries. OTCEC separations of three selected drug substances (propiophenone, benzoin, and warfarin) were also demonstrated. Scanning electron microscopy was used for the characterization of the sol-gel gold nanoparticle capillary surface. The results confirm that dodecanethiol gold nanoparticles, bound on the sol-gel-based inner layer of fused-silica capillary, can provide sufficient solute-bonded phase interactions for OTCEC with reproducible retention as well as characteristic reversed-phase behaviour.  相似文献   

19.
20.
The use of nanoparticles (NPs) in immunodiagnostics is a challenging task for many reasons, including the need for miniaturization. In view of the development of an assay dedicated to an original, miniaturized and fully automated immunodiagnostics which aims to mimic in vivo interactions, magnetic zwitterionic bifunctional amino/polyethyleneoxide maghemite core/silica shell NPs functionalized with allergenic α‐lactalbumin were characterized by CE. Proper analytical performances were obtained through semi‐permanent capillary coating with didodecyldimethylammonium bromide (DDAB) or permanent capillary wall modification by hydroxypropylcellulose. The influence of experimental conditions (e.g. buffer component nature, pH, ionic strength, and electric field strength) on sample stability, electrophoretic mobility, and dispersion was investigated using either DDAB‐ or hydroxypropylcellulose‐coated capillaries. Adsorption to the capillary wall and aggregation phenomena were evaluated according to the CE conditions. The proper choice of experimental conditions, i.e. separation under −10 kV in a 25 mM ionic strength MES/NaOH (pH 6.0) with a DDAB‐coated capillary, allowed the separation of the grafted and the non‐grafted NPs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号