首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Electrochemical sensors are essential for point‐of‐care testing (POCT) and wearable sensing devices. Establishing an efficient electron transfer route between redox enzymes and electrodes is key for converting enzyme‐catalyzed reactions into electrochemical signals, and for the development of robust, sensitive, and selective biosensors. We demonstrate that the site‐specific incorporation of a novel synthetic amino acid (2‐amino‐3‐(4‐mercaptophenyl)propanoic acid) into redox enzymes, followed by an S‐click reaction to wire the enzyme to the electrode, facilitates electron transfer. The fabricated biosensor demonstrated real‐time and selective monitoring of tryptophan (Trp) in blood and sweat samples, with a linear range of 0.02–0.8 mm . Further developments along this route may result in dramatic expansion of portable electrochemical sensors for diverse health‐determination molecules.  相似文献   

2.
A mesoporous zirconia modified carbon paste electrode was developed for electrochemical investigations of methyl parathion (MP, Phen‐NO2). The significant increase of the peak currents and the improvement of the redox peak potential indicate that mesoporous zirconia facilitates the electronic transfer of MP. The oxidation peak current was proportional to the MP concentration in the range from 1.0×10−8 to 1.0×10−5 mol L−1 with a detection limit of 4.6×10−9 mol L−1 (S/N=3) after accumulation under open‐circuit for 210 s. The proposed method was successfully applied to the determination of MP in apple samples.  相似文献   

3.
罗启枚  李振  王辉宪  刘登友 《应用化学》2013,30(9):1082-1088
制备了一种简单的聚谷氨酸修饰玻碳电极的用于检测甲基对硫磷的电化学传感器。 并应用循环伏安法研究了甲基对硫磷在该修饰电极上的氧化还原行为;甲基对硫磷的浓度检测采用差分脉冲伏安法,结果表明,甲基对硫磷在5.0×10-7~7.5×10-4 mol/L浓度范围与响应电流有良好的线性关系。 甲基对硫磷检测限(S/N=3)可达1.0×10-9 mol/L。 该法制备的传感器有望应用于实际样品中的甲基对硫磷的检测。  相似文献   

4.
The design and development of modern biosensors for sensitive and selective detection of various biomarkers is important in diversified arenas including healthcare, environment, and food industries etc. The requirement of more robust and reliant biosensors lead to the development of various sensing modules. The nanomaterials having specific optical, electrical, and mechanical strength can pave the way towards development of ultrafast, robust, and miniaturized modules for biosensors. It can provide not only the point‐of‐care applicability but also has tremendous commercial as well as industrial justification. In order to improve the performance of the sensor systems, various nanostructure materials have been readily studied and applied for development of novel biosensors. In the last few years, researchers are engaged on harnessing the unique atomic and molecular properties of advance‐engineered materials including carbon nanotubes, graphene nanosheets, metal nanoparticles, metal oxide nanoparticles, and their nano‐conjugates. In view of such recent developments in nanomaterial engineering, the current review has been formulated emphasizing the role of these materials in surface engineering, biomolecule conjugation, and signal amplification for development of various ultrasensitive and robust biosensors having commercial as well as industrial viability. Attention is given on the electrochemical biosensors incorporating various nanomaterials and their conjugates. Importance of nanomaterials in the analytical performance of the various biosensor has also been discussed. To put a perceptive insights on the importance of various nanomaterials, an extended table is incorporated, which includes probe design, analyte, LOD, and dynamic range of various electrochemical biosensors.  相似文献   

5.
We report a versatile platform for highly sensitive alkaline phosphatase (ALP)‐based electrochemical biosensors that uses an avidin‐modified indium tin oxide (ITO) electrode as a sensing electrode and 1‐naphthyl phosphate (NPP) as an ALP substrate. Almost no electrocatalytic activity of NPP and good electrocatalytic activity of 1‐naphthol (ALP product) on the ITO electrodes allow a high signal‐to‐background ratio. The effective surface covering of avidin on the ITO electrodes allows very low levels of nonspecific binding of proteins to the sensing electrodes. The platform technology is used to detect mouse IgG with a detection limit of 1.0 pg/mL.  相似文献   

6.
An electrochemical biosensor was developed using Pt‐nanoparticles (Pt‐NPs) dispersed graphene based on a boron‐doped diamond thin film electrode. To compare its performances with those of other biosensors, glucose was used as a target analyte. This biosensor exhibited a wide linear range, a low detection limit and a higher sensitivity compared to other amperometric biosensors using graphene‐based electrodes. In addition, the biosensor promotes a direct electron transfer between the redox enzymes and the electrode surface and detects low concentration analytes. The excellent performance of the biosensor is attributed to the synergistic effect of the Pt‐NPs, graphene sheet and the BDD thin film. Therefore, it can be a promising application for electrochemical detection of analytes.  相似文献   

7.
《Electroanalysis》2005,17(23):2147-2155
A laccase biosensor, in which the enzyme was immobilized on N‐succinimidyl‐3‐thiopropionate (NSTP)‐modified gold electrodes, is reported. Two different approaches for the preparation of N‐succinimidyl‐terminated monolayers were evaluated: a) activation of a preformed 3‐mercaptopropionic acid (MPA) SAM by reaction with 1‐(3‐dimethylaminopropyl)‐ 3‐ethylcarbodiimide (EDC) and N‐hydroxysulfosuccinimide (NHS); b) assembling of dithiobisuccinimidyl propionate (DTSP). NSTP‐modified electrodes were characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Biosensors prepared by covalent binding of the enzyme and by cross‐linking with glutaraldehyde atop NSTP‐modified electrodes were compared in terms of sensitivity and operational range for caffeic acid. A much better analytical performance was found using the latter approach. Variables affecting the amperometric detection (enzyme loading, pH and applied potential) were optimized. The operational stability and characteristics of functioning of the laccase biosensor in terms of repeatability of the amperometric measurements, reproducibility with different biosensors and useful lifetime, were evaluated. The kinetic parameters of the enzyme reactions and the analytical characteristics of the corresponding calibration plots were calculated for eight phenolic compounds. Limits of detection of 0.07 μM, 0.05 μM and 0.09 μM were obtained for caffeic acid, catechol and 3,4‐dihydroxyphenylacetic acid (DOPAC), respectively. The practical usefulness of the developed biosensor was evaluated by estimating the “pool” of phenolic compounds in olive oil mill wastewaters (OMW).  相似文献   

8.
A novel horseradish peroxidase (HRP) electrochemical biosensor based on a MgO nanoparticles (nano‐MgO)‐chitosan (chit) composite matrix was developed. The morphology of nano‐MgO‐chit nanocomposite was examined by scanning electron microscopy (SEM). The interaction between nano‐MgO‐chit nanocomposite matrix and enzyme was characterized with UV‐vis spectra. This proposed composite material combined the advantages of inorganic nanoparticles and organic polymer chit. The HRP immobilized in the nanocomposite matrix displayed excellent electrocatalytic activity to the reduction of H2O2 in the presence of hydroquinone as a mediator. The effects of the experimental variables such as solution pH and the working potential were investigated using steady‐state amperometry. The present biosensor (HRP‐modified electrode) had a fast response towards H2O2 (less than 10 s), and excellent linear relationships were obtained in the concentration range of 0.1–1300 μM, with a detection limit of 0.05 μM (S/N=3). Moreover, the stability and reproducibility of this biosensor were evaluated with satisfactory results.  相似文献   

9.
In this study, a new glucose biosensor was fabricated by immobilizing glucose oxidase (GOx) on platinum nanoparticles (Pt NPs) decorated reduced graphene oxide (rGO)/Zn‐MOF‐74 hybrid nanomaterial. Herein, the biosensor fused the advantages of rGO with those of porous Zn‐MOF and conductive Pt NPs. This has not only enlarged the surface area and porosity for the efficient GOx immobilization and faster mass transport, but also provided favorable electrochemical features such as high current density, remarkable electron mobility through metal nanoparticles, and improved electron transfer between the components. The GOx‐rGO/Pt NPs@Zn‐MOF‐74 coated electrode displayed a linear measurement range for glucose from 0.006 to 6 mM, with a detection limit of 1.8 μM (S/N: 3) and sensitivity of 64.51 μA mM?1 cm?2. The amperometric response of the enzyme biosensor demonstrated the typical behavior of Michaelis‐Menten kinetics. The obtained satisfying sensitivity and measurement range enabled fast and accurate glucose measurement in cherry juice using the fabricated biosensor. The water‐stable Zn‐MOF‐74 demonstrated higher enzyme loading capacity and can be potent supporting material for biosensor construction.  相似文献   

10.
Present work displays the preparation of an electrochemical biosensor using a conjugated polymer and laccase enzyme for catechol quantification in samples. The biosensing system is based on an enzyme immobilization on polymer modified graphite transducer surface. For that purpose, a random conjugated polymer, thienothiophene‐benzoxadiazole‐alt‐benzodithiophene (BOTT), was coated onto a graphite electrode surface via drop casting method followed by immobilization of a biomolecule (laccase) for sensing experiments. Herein, for the first time, we proposed a BOTT polymer as an inexpensive and effective way to fabricate highly sensitive and fast response biosensors. The proposed sensing system possessed superior properties with 0.38 μM limit of detection and 110.81 μA mM?1 sensitivity. Furthermore, cyclic voltammetry and scanning electron microscopy techniques were used to examine the surface modifications. The proposed system could be useful for many future studies for catechol quantification in environmental samples.© 2019 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2019, 57, 2333–2339  相似文献   

11.
A new nanocomposite material for enzyme immobilization and subsequent direct electrochemistry and electrocatalysis was developed by using 1,2‐dimyristoyl‐sn‐glycero‐3‐phospho‐(1‐rac‐glycerol)‐phospholipid‐monolayer‐membrane‐modified graphene (DMPG‐G). Microperoxidase‐11 (MP11) was chosen as a model enzyme to investigate the composite system. Owing to the improved conductivity and biocompatible microenvironment, MP11 that was immobilized in the matrix of the DMPG‐G nanocomposite (DMPG‐G‐MP11) effectively retained its native structure and bioactivity. DMPG‐G‐MP11‐modified glassy carbon electrode (DMPG‐G‐MP11/GCE) exhibited a pair of well‐defined quasi‐reversible redox peaks of MP11 and showed high electrocatalytic activity towards hydrogen peroxide (H2O2). The linear response of the developed biosensor for the determination of H2O2 ranged from 2.0×10?6 to 4.5×10?4 M with a detection limit of 7.2×10?7 M . This biosensor exhibited high reproducibility and long‐term storage stability. The promising features of this biosensor indicate that these lipid–graphene nanocomposites are ideal candidate materials for the direct electrochemistry of redox proteins and that they could serve as a versatile platform for the construction of a third‐generation biosensor.  相似文献   

12.
A simple, miniaturized microplate chemiluminescence assay for determination of methyl parathion (MP) was developed in 384-microwell plates. Zirconia (ZrO2) was added in microwell for adsorption of acetylcholinesterase (AChE). The developed assay is based on inhibition of AChE by MP. A good dynamic range 0.008–1,000 ng/mL was obtained for MP with limit of detection 0.008 ng/mL. Intrabatch and interbatch reproducibility for miniaturized assay was obtained with % RSD up to 3.07 and 5.66, respectively. In 384 well plate formats, 70 samples were simultaneously analyzed within 20 min with assay volume of 41.5 μL. The application of developed assay was extended for MP remediation. Column containing ZrO2 was utilized for remediation where MP was selectively adsorbed. Under optimized condition, adsorption of MP on ZrO2 was found to be 98–99% with 2-h contact time in real water samples. Adsorption of MP on ZrO2 column followed by quantification using developed bioassay provides a novel approach to monitor remediation. The applicability of assay was successfully extended for determination of MP in water samples after removal through ZrO2.  相似文献   

13.
This review describes principles and features of thermal biosensors and microbiosensors in flow injection analysis. Examples are given that illustrate the great versatility and excellent operational stability offered by thermal biosensors. The examples are mostly from work with the original type of enzyme thermistor operating with an enzyme column, but there will also be work described involving miniaturised devices including thermal lab-on-chip constructions and other types of sensing materials, such as MIPs (molecularly imprinted polymers) for both affinity and catalytic reactions. Several recently presented thermal biosensor concepts are reviewed including a thermal–electrochemical hybrid sensor for lactose based on immobilised cellobiose dehydrogenase. Another recent method is the determination of fructose using a fructose-6-phosphate kinase column. Operation with complex sample matrices such as blood, plasma and milk and how to avoid non-specific temperature effects are considered.  相似文献   

14.
《Electroanalysis》2018,30(2):250-258
An electrochemical DNA biosensor for DNA determination of genetically modified (GM) soybean (CaMV 35S target genes) was developed utilizing a new detection concept based on the adsoption of anthraquinone‐2‐sulphonic acid (AQMS) on the reduced graphene oxide nano‐particles (rGO) during DNA hybridization events. The aminated DNA probe for CaMV 35S was immobilized onto poly(n‐butyl acrylate) film modified with succinimide functional groups [poly(nBA‐NAS)] via peptide covalent bond. Nanosheets of rGO were entrapped in the poly(nBA‐NAS) film to form a conducting [poly(nBA‐NAS)‐rGO] film of the DNA biosensor. Besides facilitating the electron transfer reactions, the rGO also functioned as an adsorbent for AQMS. The sensing mechanism of the proposed DNA biosensor involved measuring the oxidation current of the AQMS adsorbed on the electrode surface at −0.50 V using differential pulse voltammetry (DPV) before and after a DNA hybridization event. Under optimum conditions, the DNA biosensor demonstrated a linear proportionality between AQMS oxidation signal and logarithm cDNA concentration from 1.0×10−15 M to 1.0×10−8 M target DNA with a detection limit of 6.3×10−16 M. The electrochemical DNA biosensor possessed good selectivity and a shelf life of about 40 days with relative standard deviation of reproducibility obtained in the range of 3.7–4.6% (n=5). Evaluation of the DNA biosensor using GM soybean DNA extracts showed excellent recovery percentages of 97.2–104.0.  相似文献   

15.
《Electroanalysis》2005,17(1):7-14
This review addresses recent advances in carbon‐nanotubes (CNT) based electrochemical biosensors. The unique chemical and physical properties of CNT have paved the way to new and improved sensing devices, in general, and electrochemical biosensors, in particular. CNT‐based electrochemical transducers offer substantial improvements in the performance of amperometric enzyme electrodes, immunosensors and nucleic‐acid sensing devices. The greatly enhanced electrochemical reactivity of hydrogen peroxide and NADH at CNT‐modified electrodes makes these nanomaterials extremely attractive for numerous oxidase‐ and dehydrogenase‐based amperometric biosensors. Aligned CNT “forests” can act as molecular wires to allow efficient electron transfer between the underlying electrode and the redox centers of enzymes. Bioaffinity devices utilizing enzyme tags can greatly benefit from the enhanced response of the biocatalytic‐reaction product at the CNT transducer and from CNT amplification platforms carrying multiple tags. Common designs of CNT‐based biosensors are discussed, along with practical examples of such devices. The successful realization of CNT‐based biosensors requires proper control of their chemical and physical properties, as well as their functionalization and surface immobilization.  相似文献   

16.
A number of very recently developed electrochemical biosensing strategies are promoting electrochemical biosensing systems into practical point‐of‐care applications. The focus of research endeavors has transferred from detection of a specific analyte to the development of general biosensing strategies that can be applied for a single category of analytes, such as nucleic acids, proteins, and cells. In this Minireview, recent cutting‐edge research on electrochemical biosensing strategies are described. These developments resolved critical challenges regarding the application of electrochemical biosensors to practical point‐of‐care systems, such as rapid readout, simple biosensor fabrication method, ultra‐high detection sensitivity, direct analysis in a complex biological matrix, and multiplexed target analysis. This Minireview provides general guidelines both for scientists in the biosensing research community and for the biosensor industry on development of point‐of‐care system, benefiting global healthcare.  相似文献   

17.
Multiwalled carbon nanotube (MWCNT) was developed as a new sorbent for solid-phase extraction (SPE) of organophosphate (OP) pesticides. A combination of SPE with square-wave voltammetric (SWV) analysis resulted in a fast, sensitive, and selective electrochemical method for determination of OP pesticide using methyl parathion (MP) as a representative. Because of the strong affinity of MWCNT for phosphoric group, nitroaromatic OP compounds can strongly bind to the MWCNT surface. The macroporosity and heterogeneity of MWCNT allow extracting a large amount of MP less than 5 min. The stripping response was highly linear over the MP range of 0.05–2.0 μg/mL, with a detection limit of 0.005 μg/mL. The determination of MP in garlic samples showed acceptable accuracy. The fast extraction ability of MWCNT makes it promising sorbent for various solid-phase extractions.  相似文献   

18.
Here in this paper, xanthine oxidase (XOD) was immobilized onto the chitosan (CHT) modified electrode by a simple way of cross‐linking with glutaraldehyde (GTD) and 3‐aminopropyltriethoxysilane (KH). The electrode displayed a sharp peak to the oxidation of xanthine at a potential about 0.67 V and the optimum of pH for determination was investigated. Under the optimum conditions, the biosensor fabricated on the KH/GTD/XOD/CHT modified electrode showed excellent response to the oxidation of xanthine within the range of 0.5 to 18 μmol/L with a low detection limit of 0.0215 µmol/L, a good stability and a high selectivity. The sensor can also be used for the determination of hypoxanthine. The electrochemical results indicated that the immobilized enzyme still retained its biological activity and this provided a new way for the construction of biosensors and determination of xanthine.  相似文献   

19.
A new electrochemical immunosensor for the detection of α‐1‐fetoprotien (AFP) was developed based on AFP antibody (anti‐AFP)‐functionalized organic/inorganic hybrid nanocomposite membrane. To fabricate such a hybrid composite membrane, 3,4,9,10‐perylenetetracarboxylic acid‐bound thionine molecules (PTCTH) were initially doped into titania colloids (TiO2), and then gold nanoparticles and anti‐AFP were immobilized onto the composite film in turn. Comparison with the electrode fabricated only with thionine not 3,4,9,10‐perylenetetracarboxylic acid, the immunosensor with PTCTH exhibited high sensitivity and fast electron transfer. The presence of gold nanoparticles provided a good microenvironment for the immobilization of biomolecules, enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The modified process was characterized by scanning electron microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The surface topography of the membrane was investigated by scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 2.5 to 200.0 ng/mL towards AFP with a detection limit of 0.5 ng/mL (S/N=3). The stability, reproducibility and precision of the immunosensor were acceptable. Comparison with the conventional enzyme‐linked immunosorbent assay (ELISA), the present method did not require more labeled procedures and washing steps. Significantly, the detection methodology provides a promising approach for other proteins or biosecurities.  相似文献   

20.
In this study, a turn‐on paper‐based optical analytical system with a rapid, sensitive and quantitative response for glucose was developed. The luminescence sensing material, crystalline iridium(III)‐Zn(II) coordination polymers, or Ir‐Zne, was grown electrochemically on stainless steel mesh and then deposited on filter paper. This sensing substrate was subsequently built up under glucose oxidase encapsulated in hydrogel and then immobilized on egg membrane with the layer‐by‐layer method. Once the glucose solution was dropped onto the paper, the oxygen content was depleted simultaneously with a concomitant increase in the phosphorescence of Ir‐Zne. The detection limit for glucose was 0.05 mM. The linear dynamic range for the determination of glucose was 0.05–8.0 mM with a correlation coefficient (R2) of 0.9956 (y=68.11 [glucose]?14.72). The response time was about 0.12 s, and the sample volume was less than 5 μL. The effects of mesh size, buffer concentration, pH, enzyme concentration, temperature, and interference, and the stability of the biosensor, have also been studied in detail. Finally, the biosensor was successfully applied to the determination of glucose in human serum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号