1.
制备了多壁碳纳米管-离子液体修饰碳糊电极(MWCNTs-ILs/CPE),并以对乙酰氨基酚(PA)为电催化媒介,研究了谷胱甘肽(GSH)在该修饰电极上的电化学行为。结果表明,GSH能明显增强PA在MWCNTs-ILs/CPE上的电化学响应,且示差脉冲伏安法(DPV)的氧化峰电流与其浓度在7.50×10-7~1.00×10-4 mol/L范围内呈良好线性关系,检测限(S/N=3)为1.65×10-7 mol/L。该方法简单、快速、灵敏,用于含GSH药物的测定,加标回收率为99.5%~101.8%。  相似文献   

2.
Composites of gold nanoparticles (Au) electrochemically deposited and different metal phthalocyanines (Co, Ni, Cu, and Fe) were chemically prepared. The composites were used as modifiers for carbon paste electrodes and were used for the determination of morphine in presence of ascorbic acid and uric acid. Central metal atoms of phthalocyanine moiety affected the rate of electron transfer. Thus, the electroactivity of different modifiers were evaluated towards morphine oxidation. Au‐CoPcM‐CPE possessed the highest rate for charge transfer rate in all studied pH electrolytes. Limit of detection was 5.48×10?9 mol L?1 in the range of 4.0×10?7 to 9.0×10?4 mol L?1.  相似文献   

3.
《Electroanalysis》2018,30(8):1855-1864
A new method has been described for carbaryl determination using a simple electrochemical sensor. The unique properties of poly‐pPhenylenediamine and ionic liquid were exploited to fabricate carbon paste electrode modified with composite based on conducting polymer/ionic liquid. Electrode surface characterization was performed by electrochemical methods (cyclic voltammetry and electrochemical impedance spectroscopy) and by scanning electron microscopy. Differential pulse voltammetry was employed for the detection of carbaryl in acetate buffer solution. Different parameters affecting the carbaryl response were optimized such as ionic liquid amounts, cycle number of polymerization and monomer concentration, pH, and accumulation time. Under the optimum experimental conditions, a linear response was obtained between 0.5 and 200 μmol/L, with detection limit of 0.09 μmol/L. The developed sensor offered satisfactory results for carbaryl detection in spring water and fruit samples.  相似文献   

4.
The study presents a novel paracetamol (PA) sensor based on Pd nanoparticles (PdNPs) deposited on carboxylated graphene oxide (GO?COOH) and nafion (Nf) modified glassy carbon electrode (GCE). The morphologies of the as prepared composites were characterized using high resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM), X‐ray diffraction (XRD), X‐ray photoelectron spectroscopy (XPS), and fourier transform infrared spectroscopy (FTIR). The experimental results demonstrated that Nf/GO?COOPd displayed excellent electrocatalytic response to the oxidation PA. The linear range was 0.04–800 μM for PA with limit of detection of 0.012 μM and excellent sensitivity of 232.89 μA mM?1 cm?2. By considering the excellent performance of Nf/GO?COOPd composite such as wider linear range, lower detection, better selectivity, repeatability, reproducibility, and storage stability, the prepared composite, especially GO?COOH support, with satisfactory electrocatalytic properties was a promising material for the modification of electrode material in electrochemical sensor and biosensor field.  相似文献   

5.
In this paper, the electrochemical behavior of a carbon paste electrode modified with CdO nanoparticles as a potential electrocatalyst for the reduction of trichloroacetic acid (TCAA) was investigated using cyclic voltammetry and double‐potential step chronoamperometry. The modified electrode showed a great enhancement in cathodic peak current with respect to reduction of TCAA in acidic aqueous solution. Using this increment, a quantitative method was developed for the determination of TCAA in aqueous solution. The detection limit and linear dynamic range of TCAA are 2.3×10?6 M and 2.3×10?4–3×10?6 M, respectively.  相似文献   

6.
In this paper, a survey has been undertaken to clarify the possible reasons for the electrocatalytic activity obtained by the presence of ionic liquid in carbon paste electrode (CPE). For this purpose, the effect of the addition of traces of ionic liquid to conventional CPE was investigated. Fe(CN)63?/4? was used as a probe and two ionic liquids, namely n‐octylpyridinum hexafluorophosphate and 1‐octyl‐3‐methylimidazolium hexaflourophosphate were tested for their electrocatalytic activity. The reasons for this electrocatalytic behavior were evaluated and it was found that different factors such as increase in the ionic conduction of the binder, decrease in the resistance of the modified electrode, increase in ion exchange properties of the electrode and the inherent catalytic activity of ionic liquids are responsible for the considerable improved electrochemical response obtained in the presence of traces of ionic liquid.  相似文献   

7.
In this research, we report the preparation of a high sensitive voltammetric sensor for electrocatalytic determination of hydroxylamine (HX) in the presence of thiosulfate (TS). We describe the synthesis and characterization of CdO nanoparticles (CdO/NPs) with transmission electron microscopy (TEM) and X‐ray diffraction (XRD) methods. At an optimum condition, the two peaks are separated ca. 0.58 and 0.92 V for HX and TS at the surface of the proposed sensor. Square wave voltammetry (SWV) of HX exhibited two linear dynamic ranges with a detection limit (3σ) of 0.06 µmol L?1. The propose sensor was used for determination of HX in water samples.  相似文献   

8.
Single‐walled carbon nanotube (SWNT) and room temperature ionic liquid (i.e., 1‐butyl‐3‐methylimidazolium hexaflourophosphate, BMIMPF6) were used to fabricate paste modified glassy electrode (GCE). It was found that the electrode showed sensitive voltammetric response to xanthine (Xt). The detection limit was 2.0×10?9 M and the linear range was 5.0×10?9 to 5.0×10?6 M. The electrode also displayed good selectivity and repeatability. In the presence of uric acid (UA) and hypoxanthine (Hx) the response of Xt kept almost unchanged. Thus this electrode could find application in the determination of Xt in some real samples. The analytical performance of the BMIMPF6‐SWNT/GCE was demonstrated for the determination of Xt in human serum and urine samples.  相似文献   

9.
Electroanalysis of benazepril HCl was successful using a carbon paste electrode modified with an ionic liquid crystal ( 1‐butyl‐1‐methylpiperidinium hexafluorophosphate) in presence of sodium dodecyl sulfate. The electrode performance was compared to ionic liquids (1‐n‐hexyl‐3‐methyl imidazolium tetrafluoroborate and 1‐butyl‐4‐methyl pyridinium tetrafluoroborate). Electrochemical determination of benazepril HCl was in the linear dynamic range of 8.89×10?7 to 1.77×10?5 mol L?1 (correlation coefficient 0.999) and LOD 7.17×10?9 mol L?1. benazepril HCl was determined using this sensor in presence of urine metabolites such as uric acid, ascorbic acid. Binary mixtures of dopamine/benazepril and amlodipine/benazepril were also determined successfully.  相似文献   

10.
A reliable and simple electrochemical method has been proposed for the simultaneous determination of paracetamol (PAR) and p‐aminophenol (PAP) in pharmaceutical formulations. The oxidation and reduction peak potentials in cyclic voltammetry (CV) for PAR on carbon ionic liquid electrode (CILE) were occurred at 370 and 225 mV vs. Ag/AgCl, respectively at pH 7.0, while those for PAP on CILE appeared at 128 mV and 68 mV, respectively at the scan rate of 0.05 V s?1. In comparison to the conventional carbon paste electrode, the apparent reversibility and kinetics of the electrochemical reactions of PAR and PAP were significantly improved on CILE. In differential pulse voltammetric technique, the peak potentials for PAR and PAP appeared at 345 and 130 mV, respectively, with the peak separation of 215 mV, sufficient for their simultaneous determination in samples containing these two species. The proposed method was used for simultaneous determination of PAR and PAP in tablets. PAR and PAP can be determined in the ranges of 2.0×10?6–2.2×10?3 M and 3.0×10?7–1.0×10?3 M, with the detection limits of 5.0×10?7 and 1.0×10?7 M (calculated by 3σ), respectively. The relative standard deviations for the determination of PAR and PAP were less than 2%.  相似文献   

11.
A new strategy to make the electrochemical sensor was presented, through combining gold nanoparticles (GNPs) with reduced graphene oxide (rGO) via L‐cysteine (L‐cys) as crosslinker. The resulting electrodes were characterized by scanning electron microscopy (SEM) and electrochemical methods. And it was applied to develop a high‐sensitive electrochemical sensor for determination of sophoridine. Compared with the bare GCE and reduced graphene oxide modified electrode, the resulting electrodes exhibited excellent response toward the oxidation of sophoridine by significantly enhancing the oxidation peak currents and decreasing the overpotential of sophoridine. Under the selected conditions, there exist the linear relation between the oxidation peak currents and sophoridine concentration in the range of 1.0 x 10‐6~1.0 x 10‐4 mol L‐1, with detection limit of 4.0 x 10‐7 mol L‐1. At the same time, the method can be successfully applied to the quantitative determination of sophoridine in injection samples and its result is satisfactory.  相似文献   

12.
《Analytical letters》2012,45(16):2445-2454
A novel voltammetric sensor using multi-wall carbon nanotubes (MWNTs) coupled with Nafion modified glassy carbon electrode (GCE) was developed for the detection of methylparaben (MP). The sensor exhibited good electrocatalytic activity toward the oxidation of MP in the phosphate buffer solution (PBS, pH 6.5). It displayed good sensitivity, repeatability, reproducibility, and long-term stability. Under the optimized conditions, the anodic peak current was linear with the concentration of MP in the range of 3 × 10?6 mol L?1 to 1 × 10?4 mol L?1. The detection limit was 1 × 10?6 mol L?1. The proposed method was successfully applied to determine MP in cosmetics with satisfactory results.  相似文献   

13.
《Electroanalysis》2018,30(9):1946-1955
In this paper, a rapid and sensitive modified electrode for the simultaneous determination of hydroquinone (HQ) and bisphenol A (BPA) is proposed. The simultaneous determination of these two compounds is extremely important since they can coexist in the same sample and are very harmful to plants, animals and the environment in general. A carbon paste electrode (CPE) was modified with silver nanoparticles (nAg) and polyvinylpyrrolidone (PVP). The PVP was used as a reducing and stabilizing agent of nAg from silver nitrate in aqueous media. The nAg‐PVP composite obtained was characterized by transmission electron microscopy and UV‐vis spectroscopy. The electrochemical behavior of HQ and BPA at the nAg‐PVP/CPE was investigated in 0.1 mol L−1 B−R buffer (pH 6.0) using cyclic voltammetry (CV) and square wave voltammetry (SWV). The results indicate that the electrochemical responses are improved significantly with the use of the modified electrode. The calibration curves obtained by SWV, under the optimized conditions, showed linear ranges of 0.09–2.00 μmol L−1 for HQ (limit of detection 0.088 μmol L−1) and 0.04–1.00 μmol L−1 for BPA (limit of detection 0.025 μmol L−1). The modified electrode was successfully applied in the analysis of water samples and the results were comparable to those obtained using UV‐vis spectroscopy.  相似文献   

14.
A glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNTs) and a hydrophobic ionic liquid (IL), was used for the simultaneous voltammetric determination of theophylline (TP) and guaifenesin (GF). The results showed that the oxidations of TP and GF were facilitated at modified electrode and peak‐to‐peak separation at MWCNT? IL/GCE (252 mV) was larger than that observed at unmodified GCE (165 mV). Voltammetric signals for TP and GF exhibited linear ranges of 0.5 to 98.0 µM (R2>0.99) and 1.5 to 480.0 µM (R2>0.99), respectively. The method was used to estimate TP and GF contents in some real samples.  相似文献   

15.
A multiwalled carbon nanotube/chitosan modified glassy carbon electrode (MWCNTs‐CHT/GCE) has been used for simultaneous determination of paracetamol (PAR) and uric acid (UA). The measurements were carried out using differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA). DPV measurements showed a linear relationship between oxidation peak current and concentration of PAR and UA in phosphate buffer (pH 7) over the concentration range 2 µM to 250 µM, and 10 µM to 400 µM, respectively. The analytical performance of this sensor has been evaluated for detection of PAR and UA in human serum and human urine with satisfactory results.  相似文献   

16.
A novel perylenediimide derivative, N,N′-bis(4-{2-[2-(2-methoxyethoxy ethoxy]ethoxy}phenyl)-3,4:9,10-perylene tetracarboxydiimide, was utilized for the modification of a carbon paste electrode to develop a practical and sensitive electrochemical sensor for dopamine detection. The effects of experimental parameters (modifier amount, pH, and scan rate) on the dopamine peak current were examined. The performance of the modified carbon paste electrode was evaluated under optimum conditions and 4.6-fold increase in the peak current was obtained compared to an unmodified carbon paste electrode. The linear range was between 1 and 100?µM dopamine and the limits of detection and quantification were 0.011 and 0.036?µM, respectively. The developed sensor was also applied for the quantitative determination of dopamine in injections and promising results were obtained.  相似文献   

17.
A carbon‐based electrode using multiwall carbon nanotube as a modifier and room temperature ionic liquid as a binder has been applied for the determination of diazepam (DZP) and oxazepam (OZP) in real samples including serum, urine and tablets. Square wave voltammetry as an appropriate electrochemical technique was applied to achieve improved limits of detection and higher sensitivities. The electrochemical studies were investigated under various experimental conditions such as pH, buffer concentration, ionic strength, deposition potential, deposition time and scan rate to achieve higher sensitivities. Linear concentration ranges for DZP and OZP were 0.02–0.76 mg L?1 and 0.05–1.90 mg L?1 with the detection limits of 4.1 µg L?1 and 5.8 µg L?1, respectively. The proposed method was successfully applied for the analysis of commercially available tablets as well as serum and urine samples and satisfactory results were obtained.  相似文献   

18.
A novel H2O2 amperometric biosensor based on the electrodeposition of gold nanoparticles (AuNPs) and CdS quantum dots (CdS QDs) onto a carbon paste electrode (CPE) and immobilizing hemoglobin (Hb) with ionic liquid (IL), is presented in this article. The modification process of the electrode was monitored by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Due to synergistic effects of AuNPs, CdS QDs and IL, the biosensor exhibited high stability and good bioelectrocatalytic ability to H2O2 with a linear concentration range from 10 to 750 µM and a detection limit of 4.35 µM (S/N=3).  相似文献   

19.
在0.01mol.L-1硼砂溶液(pH 9.18)中,用纳米二氧化铈修饰碳糊电极作为工作电极,线性扫描伏安法测定苯酚。伏安图上出现一灵敏的氧化峰,其峰电位为+0.56V(vs.SCE),峰电流与苯酚的浓度在1.0×10-7~2.0×10-4 mol.L-1范围内呈线性关系,检出限(3s/k)为5.0×10-8 mol.L-1。富集时间为30s,同时采用线性扫描伏安法研究苯酚在纳米二氧化铈修饰碳糊电极上的氧化还原反应,结果表明此电极反应为一不可逆的吸附过程。  相似文献   

20.
A novel CdTe quantum dots‐modified carbon paste electrode (QDMCPE) was fabricated and used to study the electrooxidation of dopamine and uric acid and their mixtures by electrochemical methods. Using square wave voltammetry (SWV), a highly sensitive and simultaneous determination of dopamine and uric acid was explored at the modified electrode. SWV peak currents of dopamine and uric acid increased linearly with their concentrations in the ranges of 7.5×10?8–6.0×10?4 M, and 7.5×10?6–1.4×10?3 M, respectively. Finally this new sensor was used for determination of dopamine and uric acid in some real samples.  相似文献   