首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《中国化学会会志》2018,65(5):603-612
In this work, the electrochemical oxidation of methanol was investigated by different electrochemical methods at a carbon paste electrode (CPE) modified with (N‐5‐methoxysalicylaldehyde, N´‐2‐hydroxyacetophenon‐1, 2 phenylenediimino nickel(II) complex (Ni(II)–MHP) and reduced graphene oxide (RGO), which is named Ni(II)‐MHP/RGO/CPE, in an alkaline solution. This modified electrode was found to be efficient for the oxidation of methanol. It was found that methanol was oxidized by the NiOOH groups generated by further electrochemical oxidation of nickel(II) hydroxide on the surface of the modified electrode. Under optimum conditions, some parameters of the analyte (MeOH), such as the electron transfer coefficient (α), the electron transfer rate constant) ks), and the diffusion coefficient of species in a 0.1 M solution (pH = 13), were determined. The designed sensor showed a linear dynamic range of 2.0–100.0 and 100.0–1000.0 μM and a detection limit of 0.68 μM for MeOH determination. The Ni(II)‐MHP/RGO/CPE sensor was used in the determination of MeOH in a real sample.  相似文献   

2.
In this work, the modified carbon paste electrode (CPE) with an imidazole derivative 2‐(2,3 dihydroxy phenyl) 4‐methyl benzimidazole (DHPMB) and reduced graphene oxide (RGO) was used as an electrochemical sensor for electrocatalytic oxidation of N‐acetyl‐L‐cysteine (NAC). The electrocatalytic oxidation of N‐acetyl‐L‐cysteine on the modified electrode surface was then investigated, indicating a reduction in oxidative over voltage and an intensive increase in the current of analyte. The scan rate potential, the percentages of DHPMB and RGO, and the pH solution were optimized. Under the optimum conditions, some parameters such as the electron transfer coefficient (α) between electrode and modifier, and the electron transfer rate constant) ks) in a 0.1 M phosphate buffer solution (pH=7.0) were obtained by cyclic voltammetry method. The diffusion coefficient of species (D) 3.96×10?5 cm2 s?1 was calculated by chronoamperometeric technique and the Tafel plot was used to calculate α (0.46) for N‐ acetyl‐L‐cysteine. Also, by using differential pulse voltammetric (DPV) technique, two linear dynamic ranges of 2–18 µM and 18–1000 µM with the detection limit of 61.0 nM for N‐acetyl‐L‐cysteine (NAC) were achieved. In the co‐existence system of N‐acetyl‐L‐cysteine (NAC), uric acid (UA) and dopamine (DA), the linear response ranges for NAC, UA, and DA are 6.0–400.0 µM, 5.0–50.0 µM and 2.0–20.0 µM, respectively and the detection limits based on (C=3sb/m) are 0.067 µM, 0.246 µM and 0.136 µM, respectively. The obtained results indicated that DHPMB/RGO/CPE is applicable to separate NAC, uric acid (UA) and dopamine (DA) oxidative peaks, simultaneously. For analytic performance, the mentioned modified electrode was used for determination of NAC in the drug samples with acceptable results, and the simultaneous determination of NAC, UA and DA oxidative peaks was investigated in the serum solutions, too.  相似文献   

3.
Phosphotungstic acid (PWA) was used for accumulation of nickel ions at the carbon paste electrode for preparation of PWA-modified CPE (PWA/CPE). The PWA was evenly mixed with graphite powder and paraffin oil. Then, for preparation of Ni/PWA/CPE, Ni ions were included onto the PWA/CPE surface through immersion method at open circuit condition. The scanning electron microscopy (SEM), energy-dispersive spectroscopy and electrochemical methods were used to verify the prepared electrodes. The SEM images reveal that morphology of the CPE was influenced by PWA addition. Application of the Ni/PWA/CPE for methanol oxidation was explored by various electrochemical techniques. Electrochemical response of methanol oxidation at the surface of Ni/PWA/CPE was 2.5 times higher than that Ni/CPE. The obtained results indicated that the modified electrode exhibited high electrocatalytic activity toward methanol oxidation. Then, catalytic rate constant was found to be 8.25 × 104 cm3 mol ?1 s?1 using chronoamperometry method. Furthermore, the effects of several parameters, such as PWA loading, NiSO4 concentration, accumulation time and methanol concentration toward methanol oxidation at the surface of this modified electrode as well as stability, have been investigated.  相似文献   

4.
In this paper a molecular wire modified carbon paste electrode (MW‐CPE) was firstly prepared by mixing graphite powder with diphenylacetylene (DPA). Then a graphene (GR) and chitosan (CTS) composite film was further modified on the surface of MW‐CPE to receive the graphene functionalized electrode (CTS‐GR/MW‐CPE), which was used for the sensitive electrochemical detection of adenosine‐5′‐triphosphate (ATP). The CTS‐GR/MW‐CPE exhibited excellent electrochemical performance and the electrochemical behavior of ATP on the CTS‐GR/MW‐CPE was carefully studied by cyclic voltammetry with an irreversible oxidation peak appearing at 1.369 V (vs. SCE). The electrochemical parameters such as charge transfer coefficient (α) and electrode reaction standard rate constant (ks) were calculated with the results of 0.53 and 5.28×10?6 s?1, respectively. By using differential pulse voltammetry (DPV) as detection technique, the oxidation peak current showed good linear relationship with ATP concentration in the range from 1.0 nM to 700.0 µM with a detection limit of 0.342 nM (3σ). The common coexisting substances, such as uric acid, ascorbic acid and guanosine‐5′‐triphosphate (GTP), showed no interferences and the modified electrode was successfully applied to injection sample detection.  相似文献   

5.
Pt‐nanoparticles were synthesized and introduced into a carbon paste electrode (CPE), and the resulting modified electrode was applied to the anodic stripping voltammetry of copper(II) ions. The synthesized Pt‐nanoparticles were characterized by cyclic voltammetry, scanning electron microscopy and X‐ray photoelectron spectroscopy techniques to confirm the purity and the size of the prepared Pt‐nanoparticles (ca. 20 nm). This incorporated material seems to act as catalysts with preconcentration sites for copper(II) species that enhances the sensitivity of Cu(II) ions to Cu(I) species at a deposition potential of ?0.6 V in an aqueous solution. The experimental conditions, such as, the electrode composition, pH of the solution, pre‐concentration time, were optimized for the determination of Cu(II) ion using as‐prepared electrode. The sensitivity changes on the different binder materials and the presence of surfactants in the test solution. The interference effect of the coexisted metals were also investigated. In the presence of surfactants, especially TritonX‐100, the Cu(II) detection limit was lowered to 3.9×10?9 M. However, the Pt‐nanoparticle modified CPE begins to degrade when the period of deposition exceeds to 10 min. Linear response for copper(II) was found in the concentration range between 3.9×10?8 M and 1.6×10?6 M, with an estimated detection limit of 1.6×10?8 M (1.0 ppb) and relative standard deviation was 4.2% (n=5).  相似文献   

6.
Poly(o‐aminophenol) (POAP) was formed by successive cyclic voltammetry in monomer solution in the presence of sodium dodecyl sulfate (SDS) on the surface of a carbon paste electrode (CPE). Ni(II) ions were incorporated into the electrode by immersion of the polymeric modified electrode having amine groups in 0.1 M Ni(II) ion solution. Electrochemical study of this modified electrode shows a good redox behavior of the Ni(III)/Ni(II) couple. The electrocatalytic oxidations of glucose and other carbohydrates at the surface of the Ni/SDS‐POAP/CPE were studied in a 0.1 M NaOH solution. Compared to POAP/CPE, the SDS‐POAP/CPE significantly enhanced the catalytic efficiency of Ni ions for carbohydrates oxidation. Finally, using chronoamperometric method, the catalytic rate constants (k) for carbohydrates were calculated.  相似文献   

7.
《Analytical letters》2012,45(13):2562-2573
Abstract

A sensing system for uracil was constituted by using lanthanum hydroxide nanowires (LNW) as a modifier to obtain LNW modified carbon paste electrode (LNW/CPE) and by introducing copper(II) ion into supporting electrolyte to transform electroinactive uracil to electroactive uracil‐Cu(II) complex. The voltammetric behaviors of uracil in the presence of Cu(II) ion at LNW/CPE were investigated. A reduction peak of the uracil‐Cu(II) complex at ?0.18 V was the two‐electron reduction of Cu(II) ion in the uracil‐Cu(II) complex; while a new oxidation peak at 0.22 V was the one‐electron oxidation of the uracil‐Cu(I) complex. Additionally, the voltammetric responses of all the complexes at LNW/CPE were more sensitive than that at carbon and multiwall carbon nanotube paste electrodes, which resulted from both the large surface effect of LNW and the chemical coordination of uracil with La(III) ion in LNW. With the sensitive oxidation peak of the uracil‐Cu(I) complex at LNW/CPE, a linear range of 4.0×10?9?3.0×10?8 mol/l for uracil was obtained along with a detection limit of 2.0×10?10 mol/l. The proposed system was evaluated by the determination of uracil derivatives, anticancer drug 5‐flurouracil, in pharmaceutical preparations.  相似文献   

8.
Nickel ions were incorporated in NaY zeolite according to cation exchange mechanism. Then NiY zeolite was used as modifier for preparation of modified carbon paste electrode. The electrochemical behavior of NiY-modified carbon paste electrode (NiY/CPE) was studied in alkaline solution using cyclic voltammetry method. Ability of different electrodes containing NiY/CPE, Ni-NiY/CPE, Ni-NaY/CPE, and Ni/CPE for electrocatalytic oxidation of methanol was compared (three last electrodes prepared by open circuit accumulation of Ni(II) ions on the surface of NiY/CPE, NaY/CPE, and bare CPE, respectively). Results show that Ni-NiY/CPE is best catalyst for the electrochemical oxidation of methanol in alkaline solution and both process of earlier Ni ion incorporation through cation exchange in NaY zeolite and open circuit accumulation of Ni ion on the surface of electrode are essential to have good catalyst. Effect of graphite–zeolite ratio on electrocatalytic current was studied and 3:1 ratio of graphite–zeolite was selected as optimum ratio for preparing electrode. Ni-NiY/CPE has very good stability toward the methanol oxidation in concentration range of 0.005 to 0.5 M. Finally, using chronoamperometric method, the catalytic rate constant (k) for methanol was found to be 1.56 × 104 cm3 mol−1 s−1.  相似文献   

9.
In this study, the electrocatalytic oxidation of methanol at nickel modified ionic liquid/carbon paste electrode (Ni/IL/CPE) in alkaline medium is presented. The ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, is incorporated into the electrode as a binder. Electrochemical impedance spectroscopy is employed to evaluate the electron transfer rate of this electrode. Ni(II) ions are incorporated into the electrode by immersion of this electrode in 1.0?M nickel sulfate solution. Cyclic voltammetry and chronoamperometry techniques are used for the electrochemical study of this modified electrode in the absence and the presence of methanol. The effect of methanol concentration on the anodic peak current shows an increase in the anodic peak current up to 1.25?M. Current density of Ni/IL/CPE for methanol oxidation in alkaline media is investigated by comparison with some of the previously reported electrodes. Results show that this electrode exhibits a high efficient electrocatalytic activity toward the oxidation of methanol with the current density of 17.6?mA?cm?2. The rate constant for chemical reaction between methanol and redox sites of electrode is calculated. This new proposed electrode is simple and efficient enough, and it can be widely used as anode in direct methanol fuel cell.  相似文献   

10.
The poly(m‐toluidine) film was prepared by using the repeated potential cycling technique in an acidic solution at the surface of carbon paste electrode. Then transition metal ions of Ni(II) were incorporated to the polymer by immersion of the modified electrode in a 0.2 M NiSO4, also the electrochemical characterization of this modified electrode exhibits stable redox behavior of the Ni(III)/Ni(II) couple. The electrocatalytic ability of Ni(II)/poly(m‐toluidine)/modified carbon paste electrode (Ni/PMT/MCPE) was demonstrated by electrocatalytic oxidation of hydrogen peroxide with cyclic voltammetry and chronoamperometry methods in the alkaline solution. The effects of scan rate and hydrogen peroxide concentration on the anodic peak height of hydrogen peroxide oxidation were also investigated. The catalytic oxidation peak current showed two linear ranges with different slopes dependent on the hydrogen peroxide concentration and the lower detection limit was 6.5 μM (S/N=3). The catalytic reaction rate constant, (kh), was calculated 5.5×102 M?1 s?1 by the data of chronoamperometry. This modified electrode has many advantages such as simple preparation procedure, good reproducibility and high catalytic activity toward the hydrogen peroxide oxidation. This method was also applied as a simple method for routine control and can be employed directly without any pretreatment or separation for analysis cosmetics products.  相似文献   

11.
Development of a novel modified electrode for electrocatalytic oxidation of methanol in order to decrease overvoltage is importance. In this paper, carbon paste electrode (CPE) was modified by ZSM-5 nanozeolite. The average diameter of used nanozeolite was 97 nm. Ni2+ ions were incorporated to the nanozeolite by immersion of the modified electrode in a 0.1 M nickel chloride solution. Then, electrochemical studies of this electrode were performed by using cyclic voltammetry(CV) in alkaline medium. This modified electrode was used as an anode for the electrocatalytic oxidation of methanol in 0.1 M of NaOH solution. The obtained data demonstrated that ZSM-5 nanozeolite at the surface of CPE improves catalytic efficiency of the dispersed nickel ions toward methanol oxidation. The values of electron transfer coefficient, charge-transfer rate constant, and the electrode surface coverage are obtained 0.61, 0.2342 s?1, and 4.33 × 10?8 mol cm?2, respectively. Also, the mean value of catalytic rate constant between the methanol and redox sites of electrode and diffusion coefficient were found to be 2.54 × 104 cm3 mol?1 s?1 and 1.85 × 10?8 cm2 s?1, respectively. Obtained results from both CV and chronoamperometric techniques indicated that the electrode reaction is a diffusion-controlled process.  相似文献   

12.
A sensitive hydrogen peroxide (H2O2) biosensor was developed based on a reduced graphene oxide|carbon ceramic electrode (RGO|CCE) modified with cadmium sulfide‐hemoglobin (CdS‐Hb). The electron transfer kinetics of Hb were promoted due to the synergetic function of RGO and CdS nanoparticles. The transfer coefficient (α) and the heterogeneous electron transfer rate constant (ks) were calculated to be 0.54 and 2.6 s?1, respectively, indicating a great facilitation achieved in the electron transfer between Hb and the electrode surface. The biosensor showed a good linear response to the reduction of H2O2 over the concentration range of 2–240 µM with a detection limit of 0.24 µM (S/N=3) and a sensitivity of 1.056 µA µM?1 cm?2. The high surface coverage of the CdS‐Hb modified RGO|CCE (1.04×10?8 mol cm?2) and a smaller value of the apparent Michaelis? Menten constant (0.24 mM) confirmed excellent loading of Hb and high affinity of the biosensor for hydrogen peroxide.  相似文献   

13.
This paper describes the development of a reduced graphene oxide (RGO), carbon nanotube (CNT) and Co(II) complex (cobalt(II) bis (benzoylacetone) ethylenediimino) (CBE) modified carbon paste electrode (CPE) for simultaneous determination of isoprenaline (IP), captopril (CAP) and tryptophan (Try). A pair of well‐defined redox peaks of Co(II) complex were obtained through a direct electron transfer between the Co(II) complex and the CPE. The proposed sensor showed very efficient electrocatalytic activity for anodic oxidation of IP in a 0.1 M phosphate buffer solution (pH 7.0). Square wave voltammetry (SWV) exhibited two linear dynamic ranges of 0.125–30.0 µM and 30.0–300.0 µM for IP. The detection limit for IP was found to be 50 nM. The proposed sensor was successfully applied for the determination of IP in real samples such as human blood serum, urine and IP ampoule.  相似文献   

14.
The behavior of a modified carbon paste electrode (CPE) for simultaneous determination of copper(II) and silver(I) by anodic adsorptive stripping voltammetry (ASV) was studied. The electrode was built incorporating the bis(2‐hydroxyacetophenone) butane‐2,3‐dihydrazone (BHAB) as a complexing agent to a Nujol‐graphite base paste. The resulting electrode demonstrated linear responses over the range of Cu(II) and Ag(I) concentrations 0.1–20 and 0.01–2.0 µM respectively. The relative standard deviation (RSD) for the determination of 5.0 µM of both metal ions were 2.9 and 3.1 % for Cu(II) and Ag(I), respectively. The method has been applied to the analysis of copper in wheat and barley seed samples and silver in developed radiological film.  相似文献   

15.
《Electroanalysis》2017,29(2):423-432
In the present paper, a stable and selective non‐enzymatic sensor is reported for determination of glucose (Glc) by using a carbon paste electrode modified with multiwall carbon nanotubes and Ni(II)‐SHP complex as modifier in an alkaline solution. This modified electrode showed impressive activity for oxidation of glucose in NaOH solution. Herein, Ni(II)‐SHP acts as a suitable platform for oxidation of glucose to glucolactone on the surface of the modified electrode by decreasing the overpotential and increasing in the current of analyte. Under the optimum conditions, the rate constant and electron transfer coefficient between electrode and modifier, were calculated to be 1.04 s−1 and 0.64, respectively. The anodic peak currents indicated a linear dependency with the square root of scan rate and this behavior is the characteristic of a diffusion controlled process. So, the diffusion coefficient of glucose was found to be 3.12×10−6 cm2 s−1 due to the used number of transferred electron of 1. The obtained results revealed two linear ranges (5 to 190.0 μM (R2=0.997), 210.0 to 700.0 μM (R2=0.999)) and the detection limit of 1.3 μM for glucose was calculated by using differential pulse voltammetry (DPV) method. Also, the designed sensor was used for determination of glucose in the blood serum and urine samples. Some other advantages of Ni(II)‐SHP/CNT/CPE sensor are remarkable reproducibility, stability and selectivity which can be related to using nanomaterial of carbon nanotubes due to enhancement of electrode surface area.  相似文献   

16.
This article reports the fabrication of Acid Violet 34 (AV34)/nickel hydroxide nanosheets ultrathin film on the glassy carbon electrode (GCE) via the electrostatic layer‐by‐layer (LBL) technique, and its electrocatalytic oxidation for glucose was demonstrated. UV‐vis absorption and electrochemical impedance spectra indicate the uniform deposition of the LBL film, with a continuous and smooth film surface observed by SEM and AFM. The electrochemical performance of the ultrathin film was studied by cyclic voltammetry and chronoamperometry. The (AV34/Ni(OH)2)5 ultrathin film modified electrode displays a fast direct electron transfer attributed to the Ni2+/Ni3+ redox couple as well as remarkable electrocatalytic activity towards the oxidation of glucose. The linear response was obtained in the range 0.5–13.5 mM (R=0.9994) with a low detection limit (14 µM), high sensitivity (25.9 µA mM?1 cm?2), rapid response (less than 1 s) and excellent anti‐interference properties to the species including ascorbic acid (AA), uric acid (UA), acetamidophenol (AP) and structurally related sugars. Therefore, the AV34/Ni(OH)2 ultrathin film can be potentially used as a feasible electrochemical sensor for the determination of glucose.  相似文献   

17.
Diphenylamine (DPA) monomers have been electropolymerized on the amino‐functionalized multiwalled carbon nanotube (AFCNT) composite film modified glassy carbon electrode (GCE) by cyclic voltammetry (CV). The surface morphology of PDPA‐AFCNT was studied using field‐emission scanning electron microscopy (FE‐SEM). The interfacial electron transfer phenomenon at the modified electrode was studied using electrochemical impedance spectroscopy (EIS). The PDPA‐AFCNT/GCE represented a multifunctional sensor and showed good electrocatalytic behavior towards the oxidation of catechol and the reduction of hydrogen peroxide. Rotating‐disk electrode technique was applied to detect catechol with a sensitivity of 1360 µA mM?1 cm?2 and a detection limit of 0.01 mM. Amperometric determination of hydrogen peroxide at the PDPA‐AFCNT film modified electrode results in a linear range from 10 to 800 µM, a sensitivity of 487.1 µA mM?1 cm?2 and detection limit of 1 µM. These results show that the nano‐composite film modified electrode can be utilized to develop a multifunctional sensor.  相似文献   

18.
β‐cyclodextrin (β‐CD) functionalized silver nanoparticles (AgNPs) and reduced graphene oxide (RGO) via one step electrochemical potentiodyanamic method has been prepared. Scanning electron microscopy, Energy‐Dispersive X‐ray spectroscopy, electrochemical impedance spectroscopy and cyclic voltammetry were used to study the role of β‐CD on preparation of AgNPs and RGO. RGO/β‐CD/AgNPs modified GCE showed good electrochemical activity towards electro‐oxidation of hydrazine in terms of decreasing the over potential and increasing the peak current. The kinetic parameters such as electron transfer coefficient (α) and diffusion coefficient (Do) of the modified electrode towards hydrazine were determined to be 0.66 and 0.97×10?6 cm2 s?1, respectively. The LOD of our sensor was many folds lower than that of recommended concentration of hydrazine in drinking water by United States Environmental Protection Agency and World Health Organization. The sensor exhibited a wide linear range from 0.08 to 1110 µM and a very low detection limit (LOD) of 1.4 nM. In addition, the sensor selectively determined hydrazine even in the presence of common interferents.  相似文献   

19.
A novel carbon paste electrode modified with carbon nanotubes and 5‐amino‐2′‐ethyl‐biphenyl‐2‐ol (5AEB) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for electrocatalytic oxidation of levodopa (LD) and carbidopa (CD), is described. Cyclic voltammetry (CV) was used to investigate the redox properties of this modified electrode at various scan rates. The apparent charge transfer rate constant, ks, and transfer coefficient, a, for electron transfer between 5AEB and CPE were calculated as 17.3 s?1 and 0.5, respectively. Square wave voltammetry (SWV) exhibits a linear dynamic range from 2.5×10?7 to 2.0×10?4 M and a detection limit of 9.0×10?8 M for LD.  相似文献   

20.
In this work, tetrakis(5‐hexyn‐oxy)Fe(II) phthalocyanine was synthesised in order to perform a click reaction between the terminal alkyne groups and an azide group on a glassy carbon electrode (GCE) surface. An azide group was formed on the electrode surface following electrografting using 4‐azidobenzene diazonium tetrafluoroborate by electrochemical reduction. The Cu(I) catalyzed alkyne‐azide Huisgen cycloaddition reaction was then employed in order to react the terminal alkyne groups on the phthalocyanine with the azide groups on the GCE surface. The modified electrode was employed to catalyse the oxidation of hydrazine. The electrode showed good electrocatalytic ability towards the detection of hydrazine with a sensitivity of 15.38 µA mM?1 and a limit of detection of 1.09 µM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号