首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
A novel non‐enzymatic glucose sensor based on nickel hydroxide and intercalated graphene with ionic liquid (G‐IL) nanocomposite modified glass carbon electrode was fabricated. Scanning electron microscope, Fourier transform infrared spectra and energy dispersive X‐ray spectroscopy of the nanocomposite confirmed the morphology and ingredient of Ni(OH)2 as well as G‐IL. Moreover, experimental results of cyclic voltammetry, electrochemical impedance spectroscopy and chronoamperometry indicated the sensing properties of Ni(OH)2 at Ni(OH)2/G‐IL modified electrode towards the typical electrocatalytic oxidation process of glucose at 0.43 V in 0.10 M NaOH. The current response was linearly related to glucose concentration in a range from 0.5 to 500 μM with a detection limit of 0.2 μM (S/N = 3) and sensitivity of 647.8 μA mM?1 cm?2. The response time of the sensor to glucose was less than 2 s. This work may be expected to develop an excellent electrochemical sensing platform of G‐IL as a catalysis carrier.  相似文献   

2.
A novel enzyme‐free glucose sensor was proposed by preparation of nanorods decorated nanopore arrays (NRs/NPAs) on 316L stainless steel simply by electrochemical treatments. The NRs/NPAs sensor displays two linear ranges towards glucose determination, one range from 1 μM to 1.2 mM with a sensitivity of 202.2 μA ? cm?2 ? mM?1, another range from 1.2 mM to 7.7 mM with a sensitivity of 59.18 μA?cm?2 ? mM?1. The detection limit is 0.5 μM. The NRs/NPAs electrode exhibits excellent stability, good selectivity and reproducibility, rendering it suitable for glucose monitoring.  相似文献   

3.
A sensitive electrochemical sensor for Cr(VI) detection based on N-doped carbon coated TiC nanofiber arrays (TiC@CNx NFAs) is reported. The abundant electrocatalytic active sites contained CNx shell, highly conducting TiC core, and good electrical contact between the TiC@CNx and underlying Ti alloy endow this electrode with the excellent electrochemical sensing properties. The developed electrochemical sensor shows remarkable determination activity towards Cr(VI) with a high sensitivity of 0.88 μA μM−1 cm−2, a low detection limit of 4.0 nM (S/N=3), a wide linear range from 0.2 to 24.1 μM, good selectivity and anti-interference property.  相似文献   

4.
PtRu nanoparticles were supported on multiwall carbon nanotubes (MWNTs), which were further fabricated as an electrode for nonenzymatic glucose sensing. Transmission electron microscope and X‐ray diffraction patterns were used for characterization of the PtRu nanoparticles on MWNTs. Cyclic voltammetry and chronopotentiometry were applied to investigate the performance of the PtRu/MWNTs nanocomposite electrode for nonenzymatic oxidation of glucose. The PtRu/MWNTs electrode shows high electrocatalytic activity towards the oxidation of glucose in 0.1 M NaOH solution and thus can be used to selectively detect glucose. Under the optimal potential (+0.55 V vs. Ag/AgCl), the biosensor effectively performs a selective electrochemical analysis of glucose in the presence of common interferents, such as ascorbic acid (AA), dopamine (DP) and uric acid (UA). Wide linear calibration ranging from 1 mM to 15 mM, high sensitivity of 28.26 μA cm?2 mM?1, low detection limit of 2.5×10?5 M, and fast response time of 10 s were achieved for the detection of glucose at the PtRu/MWNTs electrode.  相似文献   

5.
At present, a highly sensitive hydrogen peroxide (H2O2) sensor is fabricated by ferrocene based naphthaquinone derivatives as 2,3‐Diferrocenyl‐1,4‐naphthoquinone and 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone. These ferrocene based naphthaquinone derivatives are characterized by H‐NMR and C‐NMR. The electrochemical properties of these ferrocene based naphthaquinone are investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) on modified glassy carbon electrode (GCE). The modified electrode with ferrocene based naphthaquinone derivatives exhibits an improved voltammetric response to the H2O2 redox reaction. 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone show excellent non‐enzymatic sensing ability towards H2O2 response with a detection limitation of 2.7 μmol/L a wide detection range from 10 μM to 400 μM in H2O2 detection. The sensor also exhibits short response time (1 s) and good sensitivity of 71.4 μA mM?1 cm?2 and stability. Furthermore, the DPV method exhibited very high sensitivity (18999 μA mM?1 cm?2) and low detection limit (0.66 μM) compared to the CA method. Ferrocene based naphthaquinone derivative based sensors have a lower cost and high stability. Thus, this novel non‐enzyme sensor has potential application in H2O2 detection.  相似文献   

6.
We report on the fabrication of an enzyme–free electrochemical sensor for glucose based on a printed film consisting of multi–walled carbon nanotubes (MWCNTs). The MWCNT–based film can be produced by means of a flexographic printing process on a polycarbonate (PC) substrate. The electrochemical response of the MWCNT–based film (referred to as MWCNT–PC) towards the oxidation of glucose at pH 7 was studied by means of cyclic voltammetry and electrochemical impedance spectroscopy. The MWCNT–PC film exhibits substantial electrocatalytic activity towards the oxidation of glucose at an anodic potential of 0.30?V (vs. Ag/AgCl). The findings reveal that the MWCNT–PC film enables non–enzymatic sensing of glucose with a detection limit as low as 2.16?μM and a sensitivity of 1045?μA?mM?1?cm?2.
Figure
Enzyme–free electrochemical sensor for glucose consisting of multi–walled carbon nanotubes was fabricated by means of flexographic printing process on polycarbonate substrate. The sensor exhibits electrocatalytic activity for glucose oxidation at an anodic potential of 0.30?V (vs. Ag/AgCl) with detection limit of 2.16?μM and sensitivity of 1045?μA?mM?1?cm?2.  相似文献   

7.
A non-enzymatic sensor was developed for the determination of glucose in alkaline medium by anodisation of copper in sodium potassium tartrate solution. The morphology of the modified copper electrode was studied by scanning electron microscopy, and its electrochemical behavior by cyclic voltammetry and electrochemical impedance spectroscopy. The electrode enables direct electrocatalytic oxidation of glucose on a CuO/Cu electrode at 0.7 V in 0.1 M sodium hydroxide. At this potential, the sensor is highly selective to glucose even in the presence of ascorbic acid, uric acid, or dopamine which are common interfering species. The sensor displays a sensitivity of 761.9 μA mM?1 cm?2, a linear detection range from 2 μM to 20 mM, a response time of <1 s, and a detection limit of 1 μM (S/N = 3). It was tested for determination of glucose level in blood serum.  相似文献   

8.
A functional Ag-Fe3O4-grapheme oxide magnetic nanocomposite was synthesized and used to prepare a nitrite sensor. Morphology and composition of the nanocomposites were characterized by a transmission electron microscope, UV-VIS spectroscopy, X-ray diffraction, and Fourier transform infrared spectra. Electrochemical investigation indicated that the nanocomposites possess excellent electrochemical oxidation ability towards nitrites. The sensor exhibited two linear ranges: one from 0.5 µM to 0.72 mM with a correlation coefficient of 0.996 and sensitivity of 1996 µA mM?1 cm?2; the other from 0.72 mM to 8.15 mM with a correlation coefficient of 0.998 and sensitivity of 426 µAmM?1 cm?2. The limit of detection of this sensing system was 0.17 µM at the signal-to-noise ratio of 3. Additionally, the sensor exhibited long-term stability, good reproducibility, and anti-interference.  相似文献   

9.
This research, for the first time, demonstrates a direct electrochemical detection of bisphenol A (BPA) using silver oxide (Ag2O) nanocubes (NCs) modified platinum electrode. The Ag2O NCs, size ranging from 60 to 100 nm utilized in this research as a smart electro-active sensing platform were pure and synthesized using a cost-effective, affordable, and facile chemical route. The Ag2O NCs modified electrochemical sensor exhibited a low limit of detection (LOD) as 20 nmol dm?3, high sensitivity as 95 μA (μmol dm?3)?1 cm?2, and linear dynamic range (LDR) varies from 80 nmol dm?3- 4.8 μmol dm?3. This sensor also showed good selectivity, reproducibility, and reusability for BPA detection. The practical application of developed sensor was also tested using real water samples. The outcomes of this research suggested that Ag2O NCs based sensor can be useful for effective and efficient electrochemical BPA sensing in both real and lab samples.  相似文献   

10.
Nitrogen‐doped hollow cobalt oxide nanofibers (Co3O4 NFs) with both glucose catalytic activity and pH sensitivity were fabricated through core‐sheath electrospinning technique, followed by calcination. The as‐developed nitrogen‐doped hollow Co3O4 NFs were thoroughly characterized using various techniques, and then employed to fabricate a dual electrochemical sensor for both pH sensing and glucose sensing. The pH sensitivity of the developed nitrogen‐doped hollow Co3O4 NFs demonstrated a Nernst constant of 12.9–15.9 mV/pH in the pH range of 3.0~9.0 and 6.8–10.7 mV/pH in the pH range of 9.0~13.0, respectively. The developed hollow cobalt oxides nanofibers sensor also possesses glucose sensitivity of 87.67 μA mM?1 cm?2, the limit of detection of 0.38 μM (S/N=3), and an acceptable selectivity against several common interferents in non‐enzymatic glucose determination. High accuracy for monitoring glucose in human serum sample was also demonstrated. These features indicate that the as‐synthesized nitrogen‐doped hollow cobalt oxides nanofibers hold great potential in the development of a unique dual sensor for both solid‐state pH sensing and superior non‐enzymatic glucose sensing.  相似文献   

11.
An electrochemical l-tryptophan sensor based on tellurium nanorods modified glassy carbon electrode was proposed. The tellurium nanorods were synthesized by a chemical reduction method. The morphology and structures of the nanorods were characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). Owing to the special structure of the tellurium nanorods, the sensor exhibits excellent electrocatalytic ability towards the oxidation of l-tryptophan and shows linearity in the range from 0.02 to 11.48 μM with a sensitivity of 256 μA mM?1 cm?2 with a correlation coefficient of 0.9945. The detection limit was 0.01 μM with signal-to-noise ratio of 3, and the response time was found to be 2 s. Moreover, the sensor also exhibited long-term stability, good reproducibility and anti-interference, thus holding promise for sensing of l-tryptophan in practice.  相似文献   

12.
A slow reaction process has been successfully used to synthesize Prussian blue/single‐walled carbon nanotubes (PB/SWNTs) nanocomposites. Electrochemical and surface characterization by cyclic voltammetry (CV), scanning electron microscopy (SEM), transmission electron microscopy (TEM), UV‐vis absorption spectroscopy, Fourier transform infrared (FTIR) spectroscopy and X‐ray diffraction (XRD) confirmed the presence of PB nanocrystallites on SWNTs. PB/SWNTs modified glassy carbon electrode (GCE) exhibits efficient electron transfer ability and high electrochemical response towards hydrazine. The fabricated hydrazine sensor showed a wide linear range of 2.0×10?6–6.0×10?3 M with a response time less than 4 s and a detection limit of 0.5 μM. PB/SWNTs modified electrochemical sensors are promising candidates for cost‐effective in the hydrazine assays.  相似文献   

13.
In this work, the nanosheet‐assembled lindgrenite microflowers (chemical formula: Cu3Mo2O9) were synthesised through a simple process and low‐cost raw materials at room temperature in aqueous solution without using any surface‐active agent. The tightly interlaced nanosheets, like petals, can increase the specific surface area, which can bring about higher electrocatalytic activity and electroanalysis sensitivity. Thus, lindgrenite microflowers were prepared as an electrochemical sensor and successfully applied in the detection of paracetamol through the modified glass carbon electrode. Furthermore, this electrochemical reaction process was simulated at the ab‐initio level to reveal the catalytic mechanism, and the simulation results agreed well with electrochemical experiments. The electrochemical performance of the lindgrenite microflowers modified glassy carbon electrode (GCE) was studied by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The linearity of paracetamol ranged from 0.05 to 1200 μM (IT method) and 0.05 to 1000 μM (DPV method), low detection limit (0.01 μM) and high sensitivity (5.11 mA mM?1 cm?2) towards paracetamol. Moreover, this sensor was applied to detect paracetamol in human blood serum samples. The excellent results demonstrated that the prepared electrode not only showed a desirable linear range towards paracetamol but also exhibited practical applicability and reliability towards human serum samples detection.  相似文献   

14.
The graphene oxide (GO) nanosheets were produced by chemical conversion of graphite, and were characterized by transmission electron microscope (TEM), Fourier transform infrared spectroscopy (FT-IR). An electrochemical sensor based on Ni/graphene (GR) composite film was developed by incorporating Ni2+ into the graphene oxide film modified glassy carbon electrode (Ni/GO/GCE) through the electrostatic interactions with negatively charged graphene oxide. The Ni2+/graphene modified glassy carbon electrode (Ni/GR/GCE) was prepared by cyclic voltammetric scanning of Ni/GO/GCE in the potential range from ?1.5 to 0.2 V at 50 mV s?1 for 5 cycles. The electrochemical activity of Ni/GR/GCE was illustrated in 0.10 M NaOH using cyclic voltammetry. The Ni/GR/GCE exhibits the characteristic of improved reversibility and enhanced current responses of the Ni(III)/Ni(II) couple. The introduction of conductive graphene not only greatly facilitates the electron transfer of Ni2+, but also dramatically improves the long-term stability of the sensor by providing the electrostatic interactions. Ni/GR/GCE also shows good electrocatalytic activity toward the oxidation of glucose. The Ni/GR/GCE gives a good linear range over 10 to 2700 μM with a detection limit of 5 μM towards the determination of glucose by amperometry. This sensor keeps over 85% activity towards 0.1 mM glucose after being stored in air for a month, respectively. Furthermore, the modified sensor was successfully applied to the sensitive determination of glucose in blood samples.  相似文献   

15.
Nanostructured NiCu layered double hydroxides (NiCu LDHs) are synthesized in situ on polypyrrole nanotubes through convenient co-precipitation and hydrothermal synthesis. The nanostructured composite (NiCu LDHs/PPy) shows high electrocatalytic activities towards the glucose oxidation reaction in alkaline electrolyte so that a nonenzymatic glucose sensor is developed. It is demonstrated that the sensor offers a wide linear range from 1.5 μM to 1.0 mM with a high sensitivity of 525.8 μA mM−1 cm−2 and a low limit of detection of 66 nM (S/N = 3). The nonenzymatic sensor has been successfully applied to real blood samples for glucose monitoring with high accuracy.  相似文献   

16.
In this paper, self‐assembled Prussian blue nanoparticles (PBNPs) on carbon ceramic electrode (CCE) were developed as a high sensitive hydrogen peroxide (H2O2) electrochemical sensor. The PBNPs film was prepared by a simple dipping method. The morphology of the PBNPs‐modified CCE was characterized by scanning electron microscopy (SEM). The self‐assembled PB film exhibited sufficient mechanical, electrochemical stability and high sensitivity in compare with other PB based H2O2 sensors. The sensor showed a good linear response for H2O2 over the concentration range 1 μM–0.26 mM with a detection limit of ca. 0.7 μM (S/N=3), and sensitivity of 754.6 mA M?1 cm?2. This work demonstrates the feasibility of self‐assembled PBNPs‐modified CCE for practical sensing applications.  相似文献   

17.
Despite its excellent properties, the inherent unstable nature of black phosphorus (BP) in ambient atmosphere has severely restricted its use in electrochemical sensing applications. In this work, polyaniline (PANI) sheathed BP was prepared via the electrochemical polymerisation of aniline on BP coated screen printed carbon electrode (i. e., SPCE/BP) which resulted in an efficient, stable electrochemical platform (i. e., SPCE/BP@PANI) with improved properties which was evaluated for electrochemical detection of two model bioanalytes namely, ascorbic acid (AA) and Hydrazine (Hy). The formation of PANI on the SPCE/BP exhibited a pair of stable and well‐defined redox peaks indicating the better adsorption energy and fast electron transfer nature of BP as compared to other 2D materials like graphene and transitional metal dichalcogenides. FESEM and XPS studies revealed the formation and uniform growth of PANI on BP surface without any aggregation. Electrochemical impedance spectroscopy analyses revealed that SPCE/BP@PANI can act as a suitable electrocatalyst material for the sensing of AA and Hy. Thus, SPCE/BP@PANI electrode exhibited low limit of detection (DL; 1.69 μM), excellent reproducibility and better selectivity towards AA oxidation over glucose, sucrose, urea, citric acid, sodium, nitrate, nitrite and magnesium with a sensitivity of 3.38 A M?1 cm?2 (R2=0.98) in the dynamic range of 10–1100 μM. The excellent analytical performance of the BP@PANI is plausible due to better adsorption energy and fast electron transfer of BP. Further, SPCE/BP@PANI was also used for successful detection of AA in processed fruit juice with good recovery. Under the optimal DPV conditions, the modified electrode was extended for detection of Hy in a linear range of 100–1500 μM with sensitivity of 0.09 A M?1 cm?2 (R2=0.99) and DL=89 μM validating the potential of BP based composites in wide range of electrochemical applications.  相似文献   

18.
In this work, rapid, sensitive, practical, and economical strategy for non-enzymatic glucose sensor has been reported based on a modification of copper nanoparticles upon conducting polymer with high surface area (Cu@PCR). Firstly, PCR conducting polymer electrode (PCR) has been successfully fabricated by electrochemical polymerization of a specially synthesized and characterized star-shaped carbazole derivative. Then copper nanoparticles have been successfully electrodeposited on the PCR as a practical method with cyclic voltammetry. The morphologies of the synthesized materials have been characterized by scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) measurements. The Cu@PCR sensor platform has been displayed a synergistic effect of high catalytical properties of copper nanoparticles and high electroactive properties of PCR towards the glucose oxidation in alkaline medium. The Cu@PCR sensor platform has shown high sensitivity of 847 μAmM−1cm−2, good stability (10 weeks), a low detection limit of 0.043 μM, and a fast response of 3 s for the non-enzymatic electrochemical detection of glucose. This organic−inorganic hybrid composite sensor is a promising candidate for the fabrication of a highly sensitive and rapid glucose-sensing with the simple preparation procedure and use of a low-cost precursor.  相似文献   

19.
The number of studies conducted about nonenzymatic electrochemical sensors has increased in recent years due to the development of more stable and robust electrodes using noble metals. One of the key aspects for achieving high sensing performance including detection limit and sensitivity is the design of electrode architecture. Herein, we report a new electrochemical sensing platform featuring ultrathin standing gold nanowires (AuNWs) for nonenzymatic detection of hydrogen peroxide (H2O2). The use of AuNWs resulted in an increased electron transfer efficiency due to the higher active surface area compared to traditional gold film electrodes. This sensor demonstrates good selectivity, reproducibility, a linear range up to 49.5 mM of H2O2 with a sensitivity of 0.185±0.003 mAmM?1cm?2 and a limit of detection of 111 μM. The biological relevance of this sensor was tested in cell culture media to illustrate the performance of the proposed sensing electrode in complex biological media.  相似文献   

20.
A novel electrochemical sensor on ZIF-8 nanocomposites (Ag/ZnO/ZIF-8) was developed to analyze the mercury ions (Hg2+). The ZIF-8 materials are one of the 3-dimensional porous metal-organic frameworks with highly accessible pores and great surface area. The ZIF-8 nanocomposites were prepared through simple sol-gel methods and their physio-chemical properties were characterized via different analytical analyses. As a result of cyclic voltammetry, Ag/ZnO/ZIF-8 exhibited a better electrocatalytic behavior towards the detection of mercury ions (Hg2+). Furthermore, the composite modified electrode was then inspected as a sensor for DPV detection of mercury ions. The nanocomposite sensor performed a wide linear range from 0.5 μM to 140 μM with a low detection limit of 40 nM, and high sensitivity of 56.06 μA μM−1 cm−2. Moreover, the ZIF-8 composite sensor showed a higher selectivity toward the detection of mercury ions (Hg2+). The real-time applications of the ZIF-8 composites sensor were inspected in various samples with good sensitivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号