The H-point standard addition method (HPSAM) for simultaneous determination of Fe(II) and Fe(III) is described. The method is based on the difference in the rate of complex formation of iron in two different oxidation states with Gallic acid (GA) at pH 5. Fe(II) and Fe(III) can be determined in the range of 0.02–4.50 μg ml−1 and 0.05–5.00 μg ml−1, respectively, with satisfactory accuracy and precision in the presence of other metal ions, which rapidly form complexes with GA under working conditions. The proposed method was successfully applied for simultaneous determination of Fe(II) and Fe(III) in several environmental and synthetic samples with different concentration ratios of Fe(II) and Fe(III).  相似文献   

2.
The H-point standard addition method (HPSAM) was applied to kinetic data for simultaneous determination of Fe(III) and Fe(II) or selective determination of Fe(III) in the presence of Fe(II). The method is based on the difference in the rate of two processes; reduction of Fe(III) with Co(II) and subsequent complex formation of resulted Fe(II) with 1,10-phenanthroline, and direct complex formation between Fe(II) and 1,10-phenanthroline in pH 3 and cetyl trimethyl ammonium bromide, CTAB, micellar media. Fe(III) can be determined in the range of 0.75-5.13 mug ml(-1)with satisfactory accuracy and precision in the presence of excess Fe(II) under working conditions. The proposed method was successfully applied to the simultaneous determination of Fe(III) and Fe(II) and also to the selective determination of Fe(III) in the presence of Fe(II) in several synthetic mixtures containing different concentration ratios of Fe(III) to Fe(II).  相似文献   

3.
A method for simultaneous analysis of V(IV) and Co(II) has been developed by using artificial neural network (ANN). This method is based on the difference of the chemical reaction rate of V(IV) and Co(II) with Fe(III) in the presence of chromogenic reagent, 1,10-phenanthroline. The reduced product of the reaction, Fe(II), can form a colored complex with 1,10-phenanthroline and make a visible spectrophotometric signal for indirect monitoring of the V(IV) and Co(II) concentrations. Feed forward neural networks have been trained to quantify considered metal ions in mixtures under optimum conditions. The networks were shown to be capable of correlating reduced spectral kinetic data using principal component analysis (PCA) of mixtures with individual metal ion. In this way an ANN containing three layers of nodes was trained. Sigmoidal and linear transfer functions were used in the hidden and output layers, respectively, to facilitate nonlinear calibration. Both V(IV) and Co(II) were analyzed in the concentration range of 0.1-4.0 μg ml−1. The proposed method was also applied satisfactorily to the determination of considered metal ions in several synthetic and water samples.  相似文献   

4.
The H-point standard addition method (HPSAM) was applied to the simultaneous determination of zinc(II) and cobalt(II). This method is based on the difference in the absorbance of methylthymol blue complexes of Zn(II) and Co(II) at pH 6 buffered solution in different wavelength pairs. The results showed that Zn(II) and Co(II) can be determined simultaneously with concentration ratios of 20:1 and 1:7.5. Under working conditions, the proposed method was successfully applied to the simultaneous determination of zinc and cobalt in synthetic and real samples.  相似文献   

5.
The H-point standard addition method (HPSAM) was applied to the simultaneous determination of zinc(II) and cobalt(II). This method is based on the difference in the absorbance of methylthymol blue complexes of Zn(II) and Co(II) at pH 6 using different wavelength pairs. The results showed that Zn(II) and Co(II) can be determined simultaneously with concentration ratios of 20:1 and 1:7.5. Under working conditions, the proposed method was successfully applied to the simultaneous determination of zinc and cobalt in synthetic, drinking water and vitamin samples.  相似文献   

6.
《Analytical letters》2012,45(6):1209-1226
Abstract

A sensitive method for the simultaneous spectrophotometric determination of Fe(II), Cu(II), Zn(II), and Mn(II) in mixtures has been developed with the aid of multivariate calibration methods, such as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS). The method is based on the spectral differences of the analytes in their complexation reaction with 4‐(2‐pyridylazo)‐resorcinol (PAR) and the use of full spectra with wavelengths in the range of 300–600 nm. It was found that both the spectral positive and negative bands obtained against the PAR blank, are proportional to the concentration for each metal complex. The obtained linear calibration concentration ranges are 0.025–0.6, 0.05–0.8, 0.025–0.8, and 0.05–0.8 µg ml?1 for Fe(II), Cu(II), Zn(II), and Mn(II), respectively, and the LODs for the four metal ions were found to be approximately 1–3×10?2 µg ml?1. The proposed method was applied to a verification set of synthetic mixtures of these four metal ions, with models built in three different wavelength ranges, i.e., 300–450, 450–600, and 300–600 nm, corresponding to the positive, negative bands and their combinations, respectively. It was shown that the PLS model for the 300–600 nm range gave the best results (RPET=6.9% and average recovery ~100%; cf. PCR: RPET=9.5% and average Recovery ~110%). This method was also successfully applied for the determination of the four metal ions in pharmaceutical preparations, chicken feedstuff, and water samples.  相似文献   

7.
Parkash R  Bansal R  Rehani SK  Dixit S 《Talanta》1998,46(6):1573-1576
A simple, rapid, sensitive and selective method for the microgram detection and spectrophotometric determination of EDTA in water, human urine and detergents, based on its reaction with Co(II) and phosphomolybdic acid at pH 0.5–2.0 is reported. Absorbance is measured against Co(II)–phosphomolybdic acid reference solution at 750 nm. The effect of time, temperature, pH and Co(II) or phosphomolybdic acid concentration is studied, and optimum operating conditions are established. Beer's law is applicable in the concentration range 0.3–1.9 μg ml−1 of 10−5M EDTA. Its detection limit is 0.14 μg in the solution phase and 0.03 μg in the resin phase. The relative standard deviation is ±0.13 μg. Ag(I), Zn(II), Cu(II), Ni(II), Pb(II), Cd(II), Ca(II), Mg(II), Fe(III), Cr(III), U(VI), chloride, nitrite, phosphate, oxalate, borate and amino acids do not interfere.  相似文献   

8.
A partial least squares (PLS-1) calibration model based on kinetic—spectrophotometric measurement, for the simultaneous determination of Cu(II), Ni(II) and Co(II) ions is described. The method was based on the difference in the rate of the reaction between Co(II), Ni(II) and Cu(II) ions with 1-(2-pyridylazo)2-naphthol in a pH 5.8 buffer solution and in micellar media at 25°C. The absorption kinetic profiles of the solutions were monitored by measuring the absorbance at 570 nm at 2 s intervals during the time range of 0–10 min after initiation of the reaction. The experimental calibration matrix for the partial least squares (PLS-1) model was designed with 30 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 0.1-2 μg mL−1 for each cation. The proposed method was successfully applied to the simultaneous determination of Cu(II), Ni(II) and Co(II) ions in water and in synthetic alloy samples.   相似文献   

9.
Norkus E 《Talanta》1998,47(5):759-1301
A potentiometric titration for cobalt(II) determination in the presence of Co(III) based on the oxidation of Co(II) with Na2CrO4 in ethylenediamine medium and back-titration of the oxidant excess with (NH4)2Fe(SO4)2 in acid medium is described. The titration is monitored with a Pt indicator electrode and carried out until the greatest jump of potential from one drop of titrant appears. A RSD smaller than 1.5% has been obtained for 50–300 μmol Co(II). The method proposed was applied in the analysis of a new type electroless copper plating solutions containing Co(II)-ethylenediamine complex compounds as reducing agents. Cu(II), Co(III) and Cr(III) do not interfere in the determination of Co(II).  相似文献   

10.
Sözgen K  Tütem E 《Talanta》2004,62(5):971-976
A simple, sensitive and rapid derivative spectrophotometric method using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) has been developed for simultaneous determination of Co(II), Ni(II) and Fe(II) which have very similar chemical behavior and appear together in many real samples. The complexes of all these metal ions with 5-Br-PADAP were formed immediately at pH 7.0 ammonium acetate buffered solution and were stable for at least 24 h. Second derivative spectra were selected for evaluation, because working wavelength determination was more precise and spectral overlap was less than in the ordinary and first derivative spectra. Three wavelengths at which the complexes exhibit extremum 2D values for Co(II), Ni(II) and Fe(II) were selected as analytical wavelengths, i.e., 640, 600 and 740 nm, respectively. Calibration curves drawn with zero-to-peak values at mentioned wavelengths were linear between 80 and 2000 ng ml−1 for each metal ion. Concentrations of Co(II) and Ni(II) were calculated from the total 2D values and the sum of the linear equations for these three cations at 640 and 600 nm, after Fe(II) assay by making use of the 2D value at 740 nm. Limits of detection (LOD) for Co(II), Ni(II) and Fe(II) were 2.7, 13.9 and 3.0 ng ml−1, respectively. The method has been applied to tool steel and heater resistance wire samples successfully.  相似文献   

11.
A very simple and selective spectrophotometric method for simultaneous determination of Co(II) and Ni(II) by 1-(2-pyridylazo) 2-naphthol (PAN), in micellar media, using H-point standard addition method (HPSAM) is described. The ligand and its metal complexes (Co(II)-PAN and Ni(II)-PAN) were made water-soluble by the neutral surfactant Triton X-100, and therefore, no extraction with organic solvents was required. Formation of both the complexes was complete within 10 min at pH 9 (adjusted by ammonia buffer). The linear range was 0.10-2.00 microg ml(-1) for Co(II) and 0.05-1.50 microg ml(-1) for Ni(II). The relative standard deviation (R.S.D.) for the simultaneous determination of 0.50 microg ml(-1) each of Co(II) and Ni(II) was 2.32 and 3.13%, respectively. Interference effects of common anions and cations were studied and the method was applied to simultaneous determination of Co(II) and Ni(II) in alloy samples. The method was compared with derivative spectrophotometric method.  相似文献   

12.
The applicability of H-point standard additions method (HPSAM) to the resolving of overlapping spectra corresponding to the sulfamethoxazole and trimethoprim is verified by UV-vis spectrophotometry. The results show that the H-point standard additions method with simultaneous addition of both analytes is suitable for the simultaneous determination of sulfamethoxazole and trimethoprim in aqueous media. The results of applying the H-point standard additions method showed that the two drugs could be determined simultaneously with the concentration ratios of sulfamethoxazole to trimethoprim varying from 1:18 to 16:1 in the mixed samples. Also, the limits of detections were 0.58 and 0.37 μmol L(-1) for sulfamethoxazole and trimethoprim, respectively. In addition the means of the calculated RSD (%) were 1.63 and 2.01 for SMX and TMP, respectively in synthetic mixtures. The proposed method has been successfully applied to the simultaneous determination of sulfamethoxazole and trimethoprim in some synthetic, pharmaceutical formulation and biological fluid samples.  相似文献   

13.
The H-point standard addition method was applied to kinetic data for simultaneous determination of Fe(II) and Fe(III) or selective determination of Fe(II) in the presence of Fe(III). The method is based on the difference in the rate of complex formation between iron in two different oxidation states and methylthymol blue (MTB) at pH 3.5 in mixed cetyltrimethylammonium bromide (CTAB) and Triton X-100 micellar medium. Fe(II) can be determined in the range 0.25-2.5 microg ml(-1) with satisfactory accuracy and precision in the presence of excess Fe(III) and other metal ions that rapidly form complexes with MTB under working condition. The proposed method was successfully applied to the simultaneous determination of Fe(II) and Fe(III) or selective determination of Fe(II) in the presence of Fe(III) in spiked real environmental and synthetic samples with complex composition.  相似文献   

14.
A cloud-point extraction (CPE) process using the nonionic surfactant Triton X-114 to simultaneous extraction and spectrophotometric determination of Zn(II), Co(II) and Ni(II) from aqueous solution using partial least squares (PLS) regression is investigated. The method is based on the color reaction of these cations with 1-(2-pyridylazo)2-naphthol and subsequent micelle-mediated extraction of products. The optimum extraction and reaction conditions such as pH, reagents concentration and effect of time have been studied. Linearity was obeyed in the range 2–150, 5–250 and 2–150 ng mL−1 of Zn(II), Co(II) and Ni(II) respectively. The relative standard error (RSE) for the simultaneous determination of 15 test samples of different concentrations of Zn(II), Co(II) and Ni(II) was 4.38%;, 1.18% and 2.42%, respectively. The total relative standard error (RSEt) for applying the PLS method to 15 synthetic samples in the linear ranges of these metals was 2.36%. The interference effect of some anions and cations was also tested. The method was applied to the simultaneous determination of Zn(II), Co(II) and Ni(II) in water and human urine samples.  相似文献   

15.
The method is based on spectrophotometric determination of Fe(II) and Fe(III) at a single wavelength (530 nm) with the use of a dedicated reversed-flow injection system. In the system, EDTA solution is injected into a carrier stream (HNO3) and then merged with a sample stream containing a mixture of sulfosalicylic acid and 1,10-phenanthroline as indicators. In an acid environment (pH ≅ 3) the indicators form complexes with both Fe(III) and Fe(II), but EDTA replaces sulfosalicylic acid, forming a more stable colourless complex with Fe(III), whereas Fe(II) remains in a complex with 1,10-phenenthroline. As a result, the area and minimum of the characteristic peak can be exploited as measures corresponding to the Fe(III) and Fe(II) concentrations, respectively. The analytes were not found to affect each other's signals, hence two analytical curves were constructed with the use of a set of standard solutions, each containing Fe(II) and Fe(III). Both analytes were determined in synthetic samples within the concentration ranges of 0.05–4.0 and 0.09–6.0 mg L−1, respectively, with precision less than 1.5 and 2.6% (RSD) and with accuracy less than 4.3 and 5.6% (RE). The method was applied to determination of the analytes in water samples collected from artesian wells and the results of the determination were consistent with those obtained using the ICP-OES technique.  相似文献   

16.
Khan MR  Khoo SB 《The Analyst》2001,126(12):2172-2177
An epoxy-graphite tube composite electrode bulk modified with 2-mercaptobenzothiazole was investigated for the simultaneous, batch determinations of Bi(III), Hg(II) and Cu(II) by differential-pulse anodic stripping voltammetry after open circuit preconcentration of the three metal ions. Systematic optimization was studied with respect to resolution and sensitivities of the differential-pulse peaks. The resolution between peaks was quantified and employed in a window diagram approach to choose the best conditions. The developed method gave detection limits of 4.2 x 10(-9), 3.6 x 10(-9) and 9.5 x 10(-8) M for Hg(II), Bi(III) and Cu(II), respectively (S/N = 3; 3 min preconcentration). The conditions whereby simultaneous determinations could be performed in the absence of cross-interferences of the analytes were also examined. Additional selected substances in the sample background were also studied for possible interferences. The developed method was applied to the simultaneous, batch determinations of Bi(III), Hg(II) and Cu(II) in a standard sample and a human hair sample.  相似文献   

17.
A new chelating matrix has been prepared by immobilising sulfanilamide (SA) on silica gel (SG) surface modified with 3-chloropropyltrimethoxysilane as a sorbent for the solid-phase extraction (SPE) Cu(II), Zn(II) and Ni(II). The determination of metal ions in aqueous solutions was carried out by inductively coupled plasma optical emission spectrometry (ICP-OES). Experimental conditions for effective sorption of trace levels of Cu(II), Zn(II) and Ni(II) were optimised with respect to different experimental parameters using the batch and column procedures. The presence of common coexisting ions does not affect the sorption capacities. The maximum sorption capacity of the sorbent at optimum conditions was found to be 34.91, 19.07 and 23.62 mg g?1 for Cu(II), Zn(II) and Ni(II), respectively. The detection limit of the method defined by IUPAC was found to be 1.60, 0.50 and 0.61 µg L?1 for Cu(II), Zn(II) and Ni(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 4.0% (n = 8). The method was applied to the recovery of Cu(II), Zn(II) and Ni(II) from the certified reference material (GBW 08301, river sediment) and to the simultaneous determination of these cations in different water samples with satisfactory results.  相似文献   

18.
Two spectrophotometric methods are described for the simultaneous determination of binary mixtures of Sn(II) and Sn(IV) in water samples and fruit juice samples, without prior separation steps, using the mean centering of ratio kinetic profiles and partial least squares (PLS) methods. The methods are based on the difference in the rate of the reactions of Sn(II) and Sn(IV) with pyrocatechol violet at pH 4.0. The methods allow rapid and accurate determination of Sn(II) and Sn(IV). The analytical characteristics of the methods for the simultaneous determination of binary mixtures of Sn(II) and Sn(IV) were calculated. The results showed that the methods were capable to simultaneous determination of 0.1–1.80 mg L−1 each of cations. The proposed methods were successfully applied to the simultaneous determination of Sn(II) and Sn(IV)in an orange juice sample.  相似文献   

19.
Li CY  Zhang XB  Jin Z  Han R  Shen GL  Yu RQ 《Analytica chimica acta》2006,580(2):143-148
An amide-linked 2,6-bis{[(2-hydroxy-5-tert-butylbenzyl)(pyridyl-2-methyl)-amino]-methyl}-4-methylphenol-ruthenium(II) tris(bipyridine) 2PF6 complex, 1, was first used to recognize Co(II) in EtOH/H2O (1:1, v/v) solution, with the ruthenium(II) tris(bipyridine) moiety selected as a fluorophore and the multi-substituted phenol unit chosen as a receptor. The fluorescence quenching of 1 was attributed to the formation of an inclusion complex between multi-substituted phenol unit and Co(II) by 1:1 complex ratio (K = 2.5 × 105), which has been utilized as the basis of the fabrication of the Co(II)-sensitive fluorescent chemosensor. The analytical performance characteristics of the proposed Co(II)-sensitive chemosensor were investigated. The sensor can be applied to the quantification of Co(II) with a linear range covering from 1.0 × 10−7 to 5.0 × 10−5 M and a detection limit of 5 × 10−8 M. The experiment results show that the response behavior of 1 to Co(II) is pH-independent in medium condition (pH 4.5–9.5) and show excellent selectivity for Co(II) over transition metal cations except Cu(II). The chemosensor has been used for determination of Co(II) in water samples.  相似文献   

20.
Ohne Zusammenfassung
Conduotometric determination of Ni(II), Co(II) and Cu(II) ions based on the formation of pyridine-rhodanide complexes