A methodology based on the coupling of a headspace autosampler with a GC and a MS detector operating in SIM mode has been developed for the determination of volatile organic compounds (THMs and BTEX) in soils. The GC device used is equipped with a programmable temperature vaporizer (PTV) packed with Tenax-TA® to introduce the samples (the injection mode used was solvent vent), and a modular accelerated column heater (MACH™) to control column temperature. The proposed measurement procedure reduces the sample pretreatment step to a minimum. Combined use of solvent vent injection mode and mass spectrometry detection allows a highly sensitive method to be proposed, with limits of detection of the order of ng/kg for all the target compounds. Furthermore, the capillary column used allows rapid separations of compounds in less than 4.60 min, affording a very short total analysis cycle time of 9 min.  相似文献   

2.
A sensitive method is presented for the fast screening and determination of residual class 1 solvents (1,1-dichloroethene, 1,2-dichloroethane, 1,1,1-trichloroethane, carbon tetrachloride and benzene) in pharmaceutical products. The applicability of a headspace (HS) autosampler in combination with GC equipped with a programmed temperature vaporizer (PTV) and a MS detector is explored. Different injection techniques were compared. The benefits of using solvent vent injection instead of split or splitless-hot injection for the measurement of volatile compounds are shown: better peak shapes, better signal-to-noise ratios, and hence better detection limits. The proposed method is extremely sensitive. The limits of detection ranged from 4.9 ppt (benzene) to 7.9 ppt (1,2-dichloroethane) and precision (measured as the relative standard deviation) was equal to or lower than 12% in all cases. The method was applied to the determination of residual solvents in nine different pharmaceutical products. The analytical performance of the method shows that it is appropriate for the determination of residual class 1 solvents and has much lower detection limits than the concentration limits proposed by the International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use. The proposed method achieves a clear improvement in sensitivity with respect to conventional headspace methods due to the use of the PTV.  相似文献   

3.
A sensitive method for the fast analysis of filbertone in spiked olive oil samples is presented. The applicability of a headspace (HS) autosampler in combination with a gas chromatograph (GC) equipped with a programmable temperature vaporizer (PTV) and a mass spectrometric (MS) detector is explored. A modular accelerated column heater (MACHTM) was used to control the temperature of the capillary gas chromatography column. This module can be heated and cooled very rapidly, shortening total analysis cycle times to a considerable extent. The proposed method does not require any previous analyte extraction, filtration and preconcentration step, as in most methods described to date. Sample preparation is reduced to placing the olive oil sample in the vial. This reduces the analysis time and the experimental errors associated with this step of the analytical process. By using headspace generation, the volatiles of the sample are analysed without interference by the non-volatile matrix, and by using injection in solvent-vent mode at the PTV inlet, most of the compounds that are more volatile than filbertone are purged and the matrix effect is minimised. Use of a liner packed with Tenax-TA? allowed the compound of interest to be retained during the venting process. The limits of detection and quantification were as low as 0.27 and 0.83 μg/L, respectively, and precision (measured as the relative standard deviation) was 5.7%. The method was applied to the determination of filbertone in spiked olive oil samples and the results revealed the good accuracy obtained with the method.  相似文献   

4.
A novel temperature-controlled headspace liquid-phase microextraction (TC-HS-LPME) device was established in which volatile solvents could be used as extractant. In this device, a PTFE vial cap with a cylindrical cavity was used as the holder of the extraction solvent. Up to 40 μl of extraction solvent could be suspended in the cavity over the headspace of aqueous sample in the vial. A cooling system based on thermoelectric cooler (TEC) was used to lower the temperature of extractant in PTFE vial cap to reduce the loss of volatile solvent during extraction process and increase the extraction efficiency. The selection of solvents for HS-LPME was then extended to volatile solvents, such as dichloromethane, ethyl acetate and acetone. The use of volatile extraction solvents instead of semi-volatile solvent reduced the interference of the large solvent peak to the analytes peaks, and enhanced the compatibility of HS-LPME with gas chromatograph (GC). Moreover, the use of larger volume of extractant solvent increases the extraction capacity and the injection volume of GC after extraction, thus improving detection limits. Several critical parameters of this technique were investigated by using chlorobenzenes (CBs) as the model analytes. High enrichment factors (498–915), low limits of detection (0.004–0.008 μg/L) and precision (3.93–5.27%) were obtained by using TC-HS-LPME/GC-FID. Relative recoveries for real samples were more than 83%.  相似文献   

5.
In-tube extraction (ITEX) is a novel solventless extraction technique in which a headspace syringe with a needle body filled with a sorbent (here: Tenax TA) is used. The analytes are extracted from sample headspace by dynamic extraction. The needle body is surrounded by a separate heater, which is used for thermal desorption of analytes into the injection port of a GC system. We report here for the first time the optimization and evaluation of a fully automated analytical method based on ITEX. As target analytes, 19 common groundwater contaminants such as halogenated volatiles and monoaromatic compounds have been chosen. Method related parameters such as extraction temperature, number of extraction cycles, extraction and desorption volume as well as extraction and desorption flow rates were investigated in detail. The linear dynamic range of the ITEX method ranged over six orders of magnitude between 0.028 microg/L and 1218 microg/L with linear correlation coefficients between 0.990 and 0.998 for the investigated compounds. Method detection limits for monoaromatic compounds were between 28 ng/L (ethylbenzene) and 68 ng/L (1,2,4-trimethylbenzene). For halogenated volatile organic compounds, method detection limits between 48 ng/L (chloroform) and 799 ng/L (dichloromethane) were obtained. The precision of the method with external calibration was between 3.1% (chloroform ethylbenzene) and 7.4% (1,2,3-trimethylbenzene).  相似文献   

6.
In the present work, a strategy for the qualitative and quantitative analysis of 24 volatile compounds listed as suspected allergens in cosmetics by the European Union is reported. The list includes benzyl alcohol, limonene, linalool, methyl 2-octynoate, β-citronellol, geraniol, citral (two isomers), 7-hydroxycitronellal, anisyl alcohol, cinnamal, cinnamyl alcohol, eugenol, isoeugenol (two isomers), coumarin, α-isomethyl ionone, lilial®, α-amylcinnamal, lyral®, α-amylcinnamyl alcohol, farnesol (three isomers), α-hexyl cinnamal, benzyl cinnamate, benzyl benzoate, and benzyl salicylate. The applicability of a headspace (HS) autosampler in combination with a gas chromatograph (GC) equipped with a programmable temperature vaporizer (PTV) and a quadrupole mass spectrometry (qMS) detector is explored. By using a headspace sampler, sample preparation is reduced to introducing the sample into the vial. This reduces the analysis time and the experimental errors associated with this step of the analytical process. Two different injection techniques were used: solvent-vent injection and hot-split injection. The first offers a way to improve sensitivity at the same time maintaining the simple headspace instrumentation and it is recommended for compounds at trace levels. The use of a liner packed with Tenax-TA® allowed the compounds of interest to be retained during the venting process. The signals obtained when hot-split injection was used allowed quantification of all the compounds according to the thresholds of the European Cosmetics Directive. Monodimensional gas chromatography coupled to a conventional quadrupole mass spectrometry detector was used and the 24 analytes were separated appropriately along a run time of about 12 min. Use of the standard addition procedure as a quantification technique overcame the matrix effect. It should be emphasized that the method showed good precision and accuracy. Furthermore, it is rapid, simple, and—in view of the results—highly suitable for the determination of suspected allergens in different cosmetic products.  相似文献   

7.
A rapid and simple large volume headspace (HS) sampling technique termed headspace solid-phase microcolumn extraction (HS-SPMCE) is described. HS gas above a liquid or solid sample is aspirated by attaching a gas-tight syringe onto a glass thermal desorption tube filled with Tenax sorbent. The trapped analytes are recovered by thermal desorption for gas chromatography–mass spectrometry (GC–MS) analysis. Benzene, toluene, ethylbenzene and the xylene isomers (BTEX) are used as model compounds to demonstrate the application of the extraction procedure for water samples. The results of the tests of the effect of agitation time and aspiration rate on recovery of the analytes show a good robustness of the method. BTEX are determined in the linear range from 0.5 to 50.0 μg L?1 with limits of detection (3 σ) ranging within 0.09–0.14 μg L?1 (MS was in scan mode). The method provides a good repeatability (RSD < 9%) and only a negligible carryover effect was observed ( ≤0.05%) when analysing BTEX at concentration 50.0 μg L?1.  相似文献   

8.
A system is described that allows the introduction of large volumes of water samples in capillary GC. Water elimination is carried out in the solvent split mode in a PTV injector with a packed liner. Two ways of separating water and analytes, i.e. evaporative and non-evaporative (solid-phase extraction), are compared. Sampling in the solid-phase extraction mode is favorable both in terms of recovery as well as with regard to sampling time. Quantitative recovery is obtained for priority pollutants ranging in volatility from dimethyl-phenol to phenanthrene. Losses occur for more volatile compounds, but even for these compounds the repeatability of the recoveries remains acceptable. With the system described here, water samples up to at least 1 ml of water can be directly analyzed. The detection limits are in the sub-ppb range.  相似文献   

9.
A method based on simplified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) extraction followed by large-injection volume-fast gas chromatography and mass spectrometry detection has been developed for the determination of trihalomethanes (chloroform, bromodichloromethane, dibromochloromethane and bromoform) and BTEX (benzene, toluene, ethylbenzene and xylenes) in soil samples.The simplified version of QuEChERS used meets the requirements of the “green chemistry” and provides reliable results with high sample throughput, low solvent consumption, little labour and the use of materials commonly employed in laboratories. The GC device used is equipped with a programmable temperature vaporizer (PTV), with a liner packed with Tenax-TA®. Using the solvent-vent mode, the PTV allows the injection of large volumes of sample, affording an improvement in the sensitivity of the method. The chromatographic conditions used here allowed the separation of the compounds in less than 5.50 min. Good linearity was obtained for all the target compounds, with highly satisfactory repeatability and reproducibility values. The limits of detection were in the 0.2 to 15 μg kg−1 range. The method was validated by the analysis of two certified reference materials.  相似文献   

10.
The combination of ionic liquid-based headspace single drop microextraction (IL-HS-SDME) and room-temperature gas chromatography/ion mobility spectrometry (RTGC-IMS) is presented for the first time using the direct determination of trihalomethanes in waters as model analytical problem. The ionic liquid allows the transference of the analytes from the sample to the analytical system, at the same time that it provides an increase of the sensitivity and selectivity of the determination. An injection unit has been designed to permit the efficient volatilization of the analytes at room temperature and to avoid the entering of IL in the system. The direct combination allows the determination of the halocompounds in a rapid and simple way taking advance of their characteristic IMS spectra. The limits of the detection range between 0.1 ng mL−1 (bromoform) and 0.9 ng mL−1 (chloroform), the reproducibility of the system being better than 7.1% (RSD). The proposed coupling opens up a new horizon in IMS-based applications.  相似文献   

11.
The analysis of samples contaminated by organic compounds is an important aspect of environmental monitoring. Because of the complex nature of these samples, isolating target organic compounds from their matrices is a major challenge. A new isolation technique, solid phase microextraction, or SPME, has recently been developed in our laboratory. This technique combines the extraction and concentration processes into one step; a fused silica fiber coated with a polymer is used to extract analytes and transfer them into a GC injector for thermal desorption and analysis. It is simple, rapid, inexpensive, completely solvent-free, and easily automated. To minimize matrix interferences in environmental samples, SPME can be used to extract analytes from the headspace above the sample. The combination of headspace sampling with SPME separates volatile and semi-volatile analytes from non-volatile compounds, thus greatly reducing the interferences from non-target compounds. This paper reports the use of headspace SPME to isolate volatile organic compounds from various matrices such as water, sand, clay, and sludge. By use of the technique, benzene, toluene, ethyl-benzene, and xylene isomers (commonly known as BTEX), and volatile chlorinated compounds can be efficiently isolated from various matrices with good precision and low limits of detection. This study has found that the sensitivity of the method can be greatly improved by the addition of salt to water samples, water to soil samples, or by heating. Headspace SPME can also be used to sample semi-volatile compounds, such as PAHs, from complex matrices.  相似文献   

12.
顶空气相色谱法测定化妆品中15种挥发性有机溶剂残留   总被引:1,自引:0,他引:1  
建立了化妆品中15种挥发性有机溶剂残留的顶空气相色谱测定方法。样品经60 ℃、30 min静态顶空后,采用气相色谱-氢火焰离子化检测器进行检测,外标法定量。加标回收试验结果表明: 15种挥发性有机溶剂残留平均回收率为62.8%~116%,相对标准偏差均小于5%。方法的检出限为0.09~0.68 mg/kg。该方法可有效克服基体干扰,一次进样可同时分离和测定化妆品中15种挥发性有机溶剂,准确灵敏,简单快速,适用于化妆品中挥发性有机溶剂残留的检测。  相似文献   

13.
A simple and rapid procedure for the determination of 22 organophosphorous pesticides (bromophos-ethyl, bromophos-methyl, chlorfenvinphos, chlorpyriphos, demethon-S-methylsulfon, diazinon, dichlorvos, dicrotophos, dimethoate, disulfoton, edifenphos, fenitrothion, fenthion, malathion, methidathion, mevinphos, monocrotophos, omethoate, parathion-ethyl, parathion-methyl, phosphamidon, and quinalphos) in human blood using headspace (HS) solid-phase microextraction (SPME) and gas chromatography (GC)-mass spectrometry (MS) is presented. The effects of various sample additions, incubation temperatures, absorption times, desorption times, and depths of fiber insertion into the injection port of the GC are optimized to enhance the sensitivity of the procedure. The recoveries of spiked blood samples are determined between 70% and 95% compared with samples prepared in water, and absolute recoveries are in the range between 0.1% and 19.6%. For quantitation in the single ion monitoring mode, linearity is established over concentration ranges from 0.025 to 5.0 microg/g with excellent coefficients of correlation (0.991-0.998). The detection limits are in the range between 0.01 and 0.3 microg/g. The time for analysis is 44 min per sample including extraction and GC-MS analysis. HS-SPME in combination with GC-MS is an effective method for the determination of organophosphorous pesticides in human blood and shows a great potential for use in rapid on-site analytical work, which is highly demanded in clinical and forensic toxicology.  相似文献   

14.
A sensitive method is presented for the fast analysis of seven fuel oxygenates (methanol, ethanol, tert-butyl alcohol (TBA), methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME) and diisopropyl ether (DIPE)) and benzene, toluene, ethylbenzene and p-xylene (BTEX) in water samples. The applicability of a headspace (HS) autosampler in combination with a GC device equipped with a programmable temperature vaporizer (PTV) and a MS detector is explored. The proposed method achieves a clear improvement in sensitivity with respect to conventional headspace methods due to the use of the PTV. Two different packed liners with materials of different trapping strengths (glass wool and Tenax-TA) were compared. The benefits of using Tenax-TA instead of glass wool as packed material for the measurement of the 11 compounds emerged as better signal-to-noise ratios and hence better detection limits. The proposed method is extremely sensitive. The limits of detection are of the order of ng/L for six of the compounds studied and of the order of microg/L for the rest, with the exception of the most polar and volatile compound: methanol. Precision (measured as the relative standard deviation for a level with an S/N ratio close to 3) was equal to or lower than 15% in all cases. The method was applied to the determination of the analytes in natural matrixes (tap, river and sea water) and the results obtained can be considered highly satisfactory. The methodology has much lower detection limits than the concentration limits proposed in drinking water by the US Environmental Protection Agency (EPA) and the European Union for compounds under regulation.  相似文献   

15.
蒋万枫  张宁  张凤艳  杨钊 《色谱》2017,35(7):760-765
建立了测定橄榄调和油中橄榄油含量的顶空气相色谱-质谱分析方法。对样品量、加热温度、加热时间、进样量、进样模式、色谱柱进行了优化。通过化学计量学方法发现了橄榄油的特征化合物。取1.0 g样品放置于20 m L顶空瓶中,在180℃加热振摇2 700 s,取1.0 m L顶空气体进样,通过HP-88色谱柱分离和质谱检测。结果表明,方法的线性范围为0~100%(橄榄油含量),线性相关系数(r2)大于0.995,检出限为1.26%~2.13%,模拟橄榄调和油中橄榄油含量测定的偏差为-0.65%~1.02%,相对偏差为-1.3%~6.8%,相对标准偏差为1.18%~4.26%(n=6)。该方法不使用任何溶剂,操作简单、快速、环保,灵敏度和准确度高,适用于橄榄调和油中橄榄油含量的测定。  相似文献   

16.
The primary standard test method used for the determination of gasoline diluent in used engine oils is method D 3525-93 of the American Society for Testing and Materials (ASTM), which involves direct injection of used oil onto a packed GC column and flame ionization detection. Recently, we have utilized a new headspace sampling method: headspace solvent microextraction (HSM), for GC and GC-MS analysis of gasoline diluent in used engine oils. High resolution capillary columns can be used without the necessity for the use of inlet cryogenic cooling or expensive sampling interfaces. This analytical method, which we generically refer to as headspace microdrop analysis yields results comparable to those obtained using the ASTM method, with the added benefit that it allows the quantification of individual volatile diluent components, including benzene, toluene, ethylbenzene and the xylenes.  相似文献   

17.
Quantification of trace concentrations of transformation products of rocket fuel unsymmetrical dimethylhydrazine (UDMH) in water requires complex analytical instrumentation and tedious sample preparation. The goal of this research was to develop a simple and automated method for sensitive quantification of UDMH transformation products in water using headspace (HS) solid-phase microextraction (SPME) in combination with GC-MS and GC-MS/MS. HS SPME is based on extraction of analytes from a gas phase above samples by a micro polymer coating followed by a thermal desorption of analytes in a GC inlet. Extraction by 85 µm Carboxen/polydimethylsiloxane fiber at 50 °C during 60 min provides the best combination of sensitivity and precision. Tandem mass spectrometric detection with positive chemical ionization improves method accuracy and selectivity. Detection limits of twelve analytes by GC-MS/MS with chemical ionization are about 10 ng L?1. GC-MS provides similar detection limits for five studied analytes; however, the list of analytes detected by this method can be further expanded. Accuracies determined by GC-MS were in the range of 75–125% for six analytes. Compared to other available methods based on non-SPME sample preparation approaches (e.g., liquid–liquid and solid-phase extraction), the developed method is simpler, automated and provides lower detection limits. It covers more UDMH transformation products than available SPME-based methods. The list of analytes could be further expanded if new standards become available. The developed method is recommended for assessing water quality in the territories affected by space activities and other related studies.  相似文献   

18.
Condensed phase membrane introduction mass spectrometry (CP‐MIMS) is an online analytical method that allows for the direct, trace level measurement of a wide range of analytes in complex samples. The technique employs a semi‐permeable membrane that transfers analytes from a sample into a flowing acceptor solvent, which is directly infused to an atmospheric pressure ionization source, such as electrospray or atmospheric pressure chemical ionization. While CP‐MIMS and variants of the technique have been in the literature for nearly a decade, much of the work has focused on instrument development. Few studies have thoroughly addressed quantitative methods related to detection limits, ionization suppression, or linear dynamic range. We examine ionization suppression in the direct rapid quantitation of analytes by CP‐MIMS and introduce several analytical strategies to mitigate these effects, including the novel implementation of a continuously infused internal standard in the acceptor phase solvent, and modulation of acceptor phase flow rate. Several representative analytes were used to evaluate this approach with spiked, complex sample matrices, including primary wastewater effluent and artificial urine. Also reported are improved measured detection limits in the low part‐per‐trillion range, using a ‘stopped‐flow’ acceptor mode. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
A fast method of analysis for 20 representative pesticides was developed using low-pressure gas chromatography-mass spectrometry (LP-GC-MS). No special techniques for injection or detection with a common quadrupole GC-MS instrument were required to use this approach. The LP-GC-MS approach used an analytical column of 10 m x 0.53 mm I.D., 1 microm film thickness coupled with a 3 m x 0.15 mm I.D. restriction capillary at the inlet end. Thus, the conditions at the injector were similar to conventional GC methods, but sub-atmospheric pressure conditions occurred throughout the analytical column (MS provided the vacuum source). Optimal LP-GC-MS conditions were determined which achieved the fastest separation with the highest signal/noise ratio in MS detection (selected ion monitoring mode). Due to faster flow-rate, thicker film, and low pressure in the analytical column, this distinctive approach provided several benefits in the analysis of the representative pesticides versus a conventional GC-MS method, which included: (i) threefold gain in the speed of chromatographic analysis; (ii) substantially increased injection volume capacity in toluene; (iii) heightened peaks with 2 s peak widths for normal MS operation; (iv) reduced thermal degradation of thermally labile analytes, such as carbamates; and (v) due to larger sample loadability lower detection limits for compounds not limited by matrix interferences. The optimized LP-GC-MS conditions were evaluated in ruggedness testing experiments involving repetitive analyses of the 20 diverse pesticides fortified in a representative food extract (carrot), and the results were compared with the conventional GC-MS approach. The matrix interferences for the quantitation ions were worse for a few pesticides (acephate, methiocarb, dimethoate, and thiabendazole) in LP-GC-MS, but similar or better results were achieved for the 16 other analytes, and sample throughput was more than doubled with the approach.  相似文献   

20.

Some aroma compounds found in alcoholic beverages are characteristic of a certain beverage (i.e. 2,4-decadienoic acid ethyl ester is characteristic of pear spirit and 5-butyltetrahydro-4-methylfuran-2-on “whiskey lactone” is characteristic of aged spirits like whiskey). These substances were detectable in beverages but not in blood samples. The aim of this investigation was to find a sensitive sampling technique for aroma compounds in whole blood samples. This technique may be used in forensic toxicology for examination of drinking claims. The method comprises dynamic headspace sampling using a purge and trap concentrator, followed by quantitative gas chromatography–mass spectrometry (dynamic HS–GC–MS). The influence of sample preparation, trap adsorbents and sample temperature as well as desorption time and purge time on the quality of the analytical results were investigated. The following optimal parameters were determined: stirred and diluted whole blood sample without salt addition, use of Carbotrap C as trap material, sample temperature at 80 °C, desorption time 20 min and purge time 30 min. These optimal parameters were used for the determination of detection limits (LOD). The LOD of aroma compounds by means of dynamic headspace sampling were compared with the results of conventional sampling: the static headspace technique. Limits of detection for the aroma compounds with conventional static headspace GC are in the range 400–10,000 μg L−1. Dynamic headspace–GC was found to be a more sensitive sampling technique for most of the aroma compounds investigated (e.g. C4–C8 ethyl esters, benzoic acid ethyl ester, linalool oxide and 4-ethylguaiacol) with detection limits between 1 and 50 μg L−1, but there were also limits to the sampling of substances with lower volatility like decanoic acid ethyl ester, 2,4-decadienoic acid ethyl ester, eugenol and whiskey lactone with detection limits of about 1,000 μg L−1.