首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A silica-based monolithic stationary phase prepared by the sol-gel process in a 100 microm I.D. fused-silica (FS) capillary has been modified chemically with 3-mercaptopropyl trimethoxysilane followed by immobilization of a strong cation-exchange (SCX) type chiral selector, (S)-N-(4-allyloxy-3,5-dichlorobenzoyl)-2-amino-3,3-dimethylbutane phosphonic acid, by radical addition reaction onto the reactive sulfhydryl surface. After a fine-tuning of the mobile phase composition, the enantioselective capillary column was evaluated for the separation of various chiral basic drugs by enantioselective non-aqueous capillary electrochromatography (CEC), in comparison to capillary column analogs packed with 3.5 microm silica particles having attached the same selector. The performance of the monolithic silica column was further compared to corresponding polymethacrylate-based organic polymer monoliths. The study indicated that strong counter-ions such as 2-aminobutanol or N,N,N',N'-tetramethylethylenediamine are needed, although they reduce the electroosmotic flow velocity and separation factors in comparison to less efficient counter-ions, in order to allow the elution of the oppositely charged solutes in the ion-exchange retention mode within reasonable run time and as sharp zones. In contrast, weak counter-ions such as N,N-diisopropylethylamine (Huenig base) provided stronger electroosmotic flow and much better separation factors, but relatively poor peak efficiencies. Overall, with the chemically functionalized monolithic silica column the high quality separations of packed column analogs could be approximated, with regards to both separation factors and peak performances. On the other hand, the monolithic capillary column certainly outperformed the packed column in terms of system robustness under capillary electrochromatography conditions and showed excellent column longevity. The enantioselective strong cation-exchange-type monolithic silica column performed also well in comparison to the organic polymer monolith.  相似文献   

2.
Enantiomer separation of chiral pharmaceuticals by capillary electrochromatography (CEC) is achieved with open-tubular capillaries (o-CEC), with packed capillaries (p-CEC) or with monolithic capillaries. In o-CEC, capillaries are coated with a thin film containing cyclodextrin derivatives, cellulose, proteins, poly-terguride or molecularly imprinted polymers as chiral selectors. In p-CEC, typical chiral HPLC stationary phases such as silica-bonded cyclodextrin or cellulose derivatives, proteins, glycoproteins, macrocyclic antibiotics, quinine-derived and 'Pirkle' selectors, polyacrylamides and molecularly imprinted polymers are used as chiral selectors. Chiral monolithic stationary phases prepared by in situ polymerization into the capillary were also developed for electrochromatographic enantiomer separation.  相似文献   

3.
Enantioseparations of chiral compounds with different structures were studied in non-aqueous capillary electrochromatography (NAQ CEC). Three different polysaccharide derivatives, cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD), amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD) and cellulose tris(4-methylbenzoate) (Chiralcel OJ) were used as chiral stationary phases (CSPs). Methanolic or ethanolic ammonium acetate solutions served as a mobile phase. The effect of the type of the CSP, the loading of the chiral selector on wide-pore aminopropyl derivatized silica gel and operational parameters such as apparent pH, applied voltage, etc. on the EOF and chromatographic characteristics (alpha, N, Rs) were studied. NAQ CEC represents a valuable alternative and an extension to chiral separations by HPLC with common-size columns as well as to capillary LC and CEC in aqueous buffers.  相似文献   

4.
The analysis of basic compounds by capillary electrochromatography (CEC) on silica-based materials using conventional HPLC stationary phases has failed to address the problem of severe peak tailing and non-reproducible chromatography. Several new generation stationary phases were evaluated using aqueous and non-aqueous mobile phases. The best results were obtained in the aqueous mode using Waters Symmetry Shield RP-8, a material in which the residual silanol groups were shielded by an octylcarbamate function. For comparison, experiments were carried out using unmodified silica.  相似文献   

5.
Enantiomeric separation of chiral pharmaceuticals is carried out in aqueous and non-aqueous packed capillary electrochromatography (CEC) using a teicoplanin chiral stationary phase (CSP). Capillaries were slurry packed with 5 microm 100-A porous silica particles modified with teicoplanin and initially evaluated using a non-aqueous polar organic mode system suitability test for the separation of metoprolol enantiomers (Rs = 2.3 and 53000 plates m(-1)). A number of pharmaceutical drugs were subsequently screened with enantioselectivity obtained for 25 racemic solutes including examples of neutral, acidic and basic molecules such as coumachlor (Rs = 3.0 and 86000 plates m(-1)) and alprenolol (Rs = 3.3 and 135000 plates m(-1)) in reversed-phase and polar organic mode, respectively. A statistical experimental design was used to investigate the effects of non-aqueous polar organic mobile phase parameters on the CEC electroosmotic flow, resolution and peak efficiency for two model solutes. Results primarily indicated that higher efficiency and resolution values could be attained at higher methanol contents which is similar to findings obtained on this phase in liquid chromatography.  相似文献   

6.
In completion of an earlier defined generic chiral screening approach, a generic separation strategy for basic, bifunctional, and neutral compounds was proposed and evaluated. This strategy adds to a previously defined strategy for acidic compounds. The screening experiment of the actual strategy used a mobile phase of 5 mM phosphate buffer pH 11.5/ACN (30/70 v/v), a temperature of 25 degrees C, and a voltage of 15 kV. The selected chiral stationary phases were Chiralpak AD-RH, Chiralcel OD-RH, Chiralcel OJ-RH, and Chiralpak AS-RH, all based on polysaccharide selectors. It was seen that 31 out of 48 test compounds were partially or baseline-resolved under screening conditions. After execution of the optimization steps of the strategy, this number increased to 41, with a total of 21 baseline-separated compounds. Combined with the results obtained from the acidic test set examined in the earlier defined strategy, of all tested compounds 82.5% showed enantioselectivity and 49.2% could be baseline-separated.  相似文献   

7.
Gübitz G  Schmid MG 《Electrophoresis》2004,25(23-24):3981-3996
This review summarizes recent developments in chiral separation in capillary zone electrophoresis (CZE), electrokinetic chromatography (EKC), and capillary electrochromatography (CEC) covering literature published since the year 2000. New chiral selectors and innovative approaches for CE and CEC are introduced. Recent progress in column technology for CEC is highlighted and the development of new chiral stationary phases is discussed. This review is not dedicated to list applications but will focus on new developments.  相似文献   

8.
Fused-silica capillaries (100 microm ID) were packed with the (3R, 4S)-Whelk-O chiral stationary phase (CSP) bonded on 3.0 microm silica particles. The enantiomers of 41 neutral analytes containing stereogenic centers, axes or planes were examined by packed capillary electrochromatography. More than 30 of these were cleanly resolved, owing to the selectivities and efficiencies afforded by this CSP. High reproducibility with no indication of diminished performance was observed using the same capillary for hundreds of runs (including intermediate change of the buffer system) over a period of several weeks. Acetate, 2-(N-morpholino)ethanesulfonic acid, or phosphate buffers, each modified with either acetonitrile or methanol, were used as mobile phases. The influence of buffer concentration, modifier amount, temperature, applied voltage, and pH on performance of the brush-type CSP was investigated.  相似文献   

9.
Lecnik O  Gübitz G  Schmid MG 《Electrophoresis》2003,24(17):2983-2985
This paper deals with the chiral separation of hydroxy acids using diallyl-dimethylammonium chloride as a positive charge-providing agent in the continuous bed. The chiral continuous bed was prepared by in situ copolymerization of monomers, including an L-4-hydroxyproline derivative as a chiral selector. This phase was applied to the chiral separation of hydroxy monocarboxylic acids and hydroxy dicarboxylic acids, respectively. The influence of both the selector concentration and the charge-providing agent on retention and separation was investigated.  相似文献   

10.
The aim of this work was to study the effects of both chemical and instrumental parameters on the separation of beta-agonists (clenbuterol (CLE), salbutamol (SAL) and terbutaline (TER)) by non-aqueous capillary electrophoresis (NACE) method. Due to the number of parameters involved and their interactions, factorial experimental designs (EDs) at two levels was applied to investigate the influence of experimental factors (ionic strength of the background electrolyte (BGE), organic solvent, injection time, voltage and temperature) in sets of several CE responses (resolution, (RS), number of theoretical plate (N), tailing factor (TF) and migration time (tm)). As a compromise between the four responses, the optimum condition was obtained in 18 mM ammonium acetate in methanol (MeOH):acetonitrile (ACN):glacial acetic acid (66:33:1%, v/v/v) using an injection time of 4 s, the voltage and the temperature of 28 kV and 24 degrees C, respectively. The proposed NACE permitted the baseline separation of the three beta-agonists within 10.5 min with good repeatability (%RSD < 3.5%) and linearity (r2 > 0.99). The developed method was applicable for the analysis of the beta-agonists in syrup and tablets and the NACE condition was compatible with a mass spectrometer detector.  相似文献   

11.
The separation of dansylated amino acids and underivatized amino acids in non-aqueous electrolytes was evaluated with direct and indirect UV detection. Different migration orders were achieved for dansylated amino acids in methanol compared to aqueous electrolyte systems. A reversed migration order was observed for some dansylated amino acids. Separation selectivity was different under acidic and basic conditions and was also a function of the solvation properties of the solvent. Underivatized amino acids were separated in basic and acidic electrolytes in methanol; different separation selectivities and, for some amino acids, a reversed migration order were also observed in these electrolyte systems. Analytical merits of the separation of both derivatized and underivatized amino acids were briefly evaluated; detection limits for dansylated amino acids were in the range of 2·10−7–4·10−7 mol/l and, for underivatized amino acids, were 2·10−6–4·10−5 mol/l.  相似文献   

12.
采用一步原位键合法制备了环糊精衍生物毛细管整体柱,在加压毛细管电色谱模式下,对盐酸地匹福林对映体进行了手性分离,并考察了以NaH2PO4作为流动相时电解质溶液pH值、柱温及分离电压等因素对分离的影响.在优化的实验条件下,地匹福林对映体达到了基线分离.  相似文献   

13.
Strong cation exchange (SCX)-type chiral stationary phases (CSPs) based on beta-amino sulfonic acid-terminated dipeptide derivatives as chiral selectors, immobilized on thiol-modified silica particles (3.5 microm), were synthesized and applied to enantiomer separations of chiral bases by nonaqueous capillary electrochromatography (CEC). The effect of structural variations of the sulfodipeptide selectors on the separation factors alpha was investigated. These studies included variation of the acid-terminal amino sulfonic acid residue, variation of the configurations, i.e., comparison of the diastereomeric (S,S)- and (R,S)-configurations of the sulfodipeptides, and finally comparison of sulfodipeptide selectors with corresponding beta-amino sulfonic acid analogs. In general, the capillary columns (100 microm ID) packed with the new SCX-type CSPs showed enantioselectivity for an elaborated set of chiral basic drugs in CEC acting by an enantioselective cation-exchange retention mechanism. N-[N-(4-Allyloxy-3,5-dichlorobenzoyl)-leucyl]-2-amino-3,3-dimethylbutane sulfonic acid, in particular with (R,S)-configuration, turned out to be a more effective SCX-type selector than a more rigid analog based on N-[N-(4-Allyloxy-3,5-dichlorobenzoyl)-leucyl]-2-pyrrolidinemethane sulfonic acid. Both of the former diastereomers were capable to baseline-resolve the enantiomers of ca. 40% of the tested basic chiral solutes including sympathomimetics and beta-blockers, while for the latter SCX-type CSPs only 10-20% of the selected solutes afforded resolutions > 1.5.  相似文献   

14.
Phospholipid-coated fused-silica capillaries with immobilized avidin were applied in the chiral separation of D,L-tryptophan, D,L-PTH-serine, and D,L-PTH-threonine at pH 7.4 by open-tubular CEC. Liposomes prepared from 1,2-dipalmitoyl-sn-glycero-3-phosphocholine, 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine-N-(Cap biotinyl), or 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine-N-(Biotinyl) with different amounts of phosphatidylserine were assessed as phospholipid coating materials. The stability of the coating and the success of the coating procedure were evaluated in terms of the repeatability of the enantiomer migration times and the resolution of enantiomers. The coating procedure itself significantly affected the migration times and resolution of the enantiomers. Reliable chiral separations with high separation efficiencies were achieved through careful choice of the coating method.  相似文献   

15.
A chiral ligand-exchange phase for capillary electrochromatography based on continuous bed technology was developed. The chiral stationary phase is prepared by a one-step in situ copolymerization procedure using methacrylamide, piperazine diacrylamide, vinylsulfonic acid and N-(2-hydroxy-3-allyloxypropyl)-L-4-hydroxyproline. These chiral continuous beds are inexpensive and easy to prepare. They also have several advantages over silica-based packed capillaries. Since the bed is covalently attached to the capillary wall, no frit is required. The applicability of this new approach to the chiral separation of underivatized amino acids is demonstrated.  相似文献   

16.
李振群  贾丽 《色谱》2020,38(9):1046-1056
手性药物通过与生物体内生物大分子之间的手性匹配与分子识别来发挥药理作用。两个对映体与体内手性环境相互作用的不同导致每个对映体表现出不同的药理活性、代谢过程、代谢速率及毒性等药代动力学特征。因此发展手性药物的拆分方法,对于手性药物的开发和生产过程的质量监控具有重要意义。分子印迹聚合物(MIPs)是以目标分子作为模板而制备的高分子聚合物,它具有特定的空间分子结构和官能团,对目标分子具有高度的特异性识别能力。基于该特点,MIPs非常适合于手性药物的拆分和纯化。毛细管电色谱(CEC)可同时基于毛细管电泳和液相色谱的分离机理对目标物进行分离,因此具有高分离效率和高选择性的特点。将MIPs材料作为CEC的固定相,可将这两种技术的优势结合,从而实现对手性药物的高效拆分。MIPs材料在1994年首次应用于CEC手性拆分,此后该研究领域开始获得关注和发展。MIPs材料主要通过4种模式在CEC中实现手性拆分,分别是作为开管柱、填充柱和整体柱的固定相以及分离介质中的准固定相。该综述以这4种模式作为分类基准,根据MIPs制备所需的材料和分离对象对其在CEC手性拆分中的应用进行了总结,揭示了MIPs在CEC手性...  相似文献   

17.
The application of the principle of ligand-exchange capillary electrophoresis to two substance classes is described. As chiral selector N-(2-hydroxyoctyl)-L-4-hydroxyproline-copper(II) complex was used. This principle was applied to the chiral separation of alpha-hydroxy acids and drugs containing amino alcohol structure such as beta-blockers. The enantioselectivity was found to be strongly dependent on pH corresponding to the optimal conditions for complex formation for each structure class.  相似文献   

18.
Some open tubular (OT) molecule imprinted polymer (MIP) silica capillary columns have been prepared using atenolol, sulpiride, methyl benzylamine (MBA) and (1-naphthyl)-ethylamine (NEA) as templates by the pre-established generalized preparation protocol. The four MIP thin layers of different templates showed quite different morphologies. The racemic selectivity of each MIP column for the template enantiomers was optimized by changing eluent composition and pH. The template structural effects on chiral separation performance have been examined. This work verifies the versatility of the generalized preparation protocol for OT-MIP silica capillary columns by extending its boundary toward templates with basic functional group moieties. This study is the very first report to demonstrate a generalized MIP preparation protocol that is valid for both acidic and basic templates. The chiral separation performances of atenolol and sulpiride by the MIPs of this study were found better than or comparable to those of atenolol and sulpiride obtained by non-MIP separation techniques and those of some basic template enantiomers obtained by MIP based techniques.  相似文献   

19.
The potential of tert.-butylcarbamoylquinine as chiral selector (SO) added to a non-aqueous background electrolyte for the capillary electrophoretic separation of the enantiomers of N-derivatized amino acids (selectands, SAs) is evaluated. Separation is based on different ion-pair formation equilibrium constants of (R) and (S) enantiomers of the negatively charged chiral analytes with the positively charged quinine-derived chiral SO and on mobility differences of free and complexed SAs, so that differences in the overall migration behavior of the SA enantiomers result. To suppress problems associated with the high UV absorption of the chiral SO and thus the high detector background in the 'total filling technique', the 'partial filling technique' has been adopted. Several parameters including filling time and length of SO zone, respectively, SO concentration, type of background electrolyte, have been evaluated. Using such an optimized method, for example, (R) and (S) enantiomers of 2,4-dinitrophenyl (DNP)-protected proline could be separated with alpha=1.08, R(S)=6.60, and N=130,000 theoretical plates within 15 min. Similar alpha values, resolution, and efficiencies were observed for other DNP-protected, as well as for diverse, N-derivatized amino acids like N-benzoyl, N-9-fluorenylmethoxycarbonyl, N-3,5-dinitrobenzyloxycarbonyl amino acids. A repeatability study clearly validated the robustness of the method and revealed its practical applicability.  相似文献   

20.
Scriba GK 《Electrophoresis》2003,24(15):2409-2421
Capillary electrophoresis is often considered an ideal method for the chiral analysis of compounds due to the high separation power of the technique and has therefore found widespread acceptance for the analysis of drugs and pharmaceuticals. In contrast, capillary electrochromatography is still more or less in an infancy state searching for its place among the analytical separation techniques although interesting applications have been published. The present review summarizes recent developments and applications of chiral pharmaceutical analysis by electromigration techniques published in 2002 and early 2003.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号