首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper presents the development and experimental analysis of a dielectrophoresis (DEP) system, which is used for the manipulation and separation of microparticles in liquid flow. The system is composed of arrays of microelectrodes integrated to a microchannel. Novel curved microelectrodes are symmetrically placed with respect to the centre of the microchannel with a minimum gap of 40 μm. Computational fluid dynamics method is utilised to characterise the DEP field and predict the dynamics of particles. The performance of the system is assessed with microspheres of 1, 5 and 12 μm diameters. When a high‐frequency potential is applied to microelectrodes a spatially varying electric field is induced in the microchannel, which creates the DEP force. Negative‐DEP behaviour is observed with particles being repelled from the microelectrodes. The particles of different dimensions experience different DEP forces and thus settle to separate equilibrium zones across the microchannel. Experiments demonstrate the capability of the system as a field flow fraction tool for sorting microparticles according to their dimensions and dielectric properties.  相似文献   

2.
Nam J  Lim H  Kim D  Shin S 《Lab on a chip》2011,11(19):3361-3364
Platelet separation from blood is essential for biochemical analyses and clinical diagnosis. In this article, we propose a method to separate platelets from undiluted whole blood using standing surface acoustic waves (SSAWs) in a microfluidic device. A polydimethylsiloxane (PDMS) microfluidic channel was fabricated and integrated with interdigitated transducer (IDT) electrodes patterned on a piezoelectric substrate. To avoid shear-induced activation of platelets, the blood sample flow was hydrodynamically focused by introducing sheath flow from two side-inlets and pressure nodes were designed to locate at side walls. By means of flow cytometric analysis, the RBC clearance ratio from whole blood was found to be over 99% and the purity of platelets was close to 98%. Conclusively, the present technique using SSAWs can directly separate platelets from undiluted whole blood with higher purity than other methods.  相似文献   

3.
A new scheme has been described for continuous particle separation using EOF in microfluidic devices. We have previously reported a method for particle separation, called "pinched flow fractionation (PFF)", in which size-dependent and continuous particle separation can be achieved by introducing pressure-driven flows with and without particles into a pinched microchannel. In this study, EOF was employed to transport fluid flows inside a microchannel. By controlling the applied voltage to electrodes inserted in each inlet/outlet port, the flow rates from both inlets, and flow rates distributed to each outlet could be accurately tuned, thus enabling more effective separation compared to the pressure-driven scheme. In the experiment, the particle behaviors were compared between EOF and pressure-driven flow schemes. In addition, micrometer- and submicrometer-sized particles were accurately separated and individually collected using a microchannel with multiple outlet branch channels, demonstrating the high efficiency of the presented scheme.  相似文献   

4.
The inertial microfluidic technique, as a powerful new tool for accurate cell/particle separation based on the hydrodynamic phenomenon, has drawn considerable interest in recent years. Despite numerous microfluidic techniques of particle separation, there are few articles in the literature on separation techniques addressing external outlet geometry to increase the throughput efficiency and purity. In this work, we report on a spiral inertial microfluidic device with high efficiency (>98%). Herein, we demonstrate how changing the outlet geometry can improve the particle separation throughput. We present a complete separation of 4 and 6 μm from 10 μm particles potentially applicable to separate microalgae (Tetraselmis suecica from Phaeodactylum tricornutum). Two spiral microchannels with the same cross section dimension but different outlet geometry were considered and tested to investigate the particle focusing behavior and separation efficiency. As compared with particle focusing observed in channels with a simple outlet, the particle focusing in a modified outlet geometry appears in a more successful focusing manner with complete separation. This simple approach of particle separation makes it attractive for lab-on-a-chip devices for continuous extraction and filtration of a wide range of cell/particle sizes.  相似文献   

5.
A method to continuously separate different particle types in a suspension is reported. Acoustic forces in a standing wave field were utilized to discriminate lipid particles from erythrocytes in whole blood. The presented technology proposes a new method of cleaning, i.e. removing lipid emboli from, shed blood recovered during cardiac surgery. Blood contaminated with lipid particles enter a laminar flow micro channel. Erythrocytes and lipid particles suspended in blood plasma are exposed to a half wavelength standing wave field orthogonal to the direction of flow as they pass through the channel. Because of differences in compressibility and density the two particle types move in different directions, the erythrocytes towards the centre of the channel and the lipid particles towards the side walls. The end of the channel is split into three outlet channels conducting the erythrocytes to the centre outlet and the lipid particles to the side outlets due to the laminar flow profile. The separation channel was evaluated in vitro using polyamide spheres suspended in water, showing separation efficiencies approaching 100%. The system was also evaluated on whole blood using tritium labelled lipid particles added to bovine blood. More than 80% of the lipid particles could be removed while approximately 70% of the erythrocytes were collected in one third of the original fluid volume. The study showed that the further reduced micro channel dimensions provided improved performance with respect to; (i) separation efficiency, (ii) actuation voltage, and (iii) volumetric throughput as compared to earlier work.  相似文献   

6.
Particle separation is a fundamental operation in the areas of biology and physical chemistry. A variety of force fields have been used to separate particles in microfluidic devices, among which electric field may be the most popular one due to its general applicability and adaptability. So far, however, electrophoresis‐based separations have been limited primarily to batchwise processes. Dielectrophoresis (DEP)‐based separations require in‐channel micro‐electrodes or micro‐insulators to produce electric field gradients. This article introduces a novel particle separation technique in DC electrokinetic flow through a planar double‐spiral microchannel. The continuous separation arises from the cross‐stream dielectrophoretic motion of particles induced by the non‐uniform electric field inherent to curved channels. Specifically, particles are focused by DEP to one sidewall of the first spiral, and then dielectrophoretically deflected toward the other sidewall of the second spiral at a particle‐dependent rate, leading to focused particle streams along different flow paths. This DEP‐based particle separation technique is demonstrated in an asymmetric double‐spiral microchannel by continuously separating a mixture of 5/10 μm particles and 3/5 μm particles.  相似文献   

7.
We report a contraction-expansion array (CEA) microchannel that allows inertial size separation by a force balance between inertial lift and Dean drag forces in fluid regimes in which inertial fluid effects become significant. An abrupt change of the cross-sectional area of the channel curves fluid streams and produces a similar effect compared to Dean flows in a curved microchannel of constant cross-section, thereby inducing Dean drag forces acting on particles. In addition, the particles are influenced by inertial lift forces throughout the contraction regions. These two forces act in opposite directions each other throughout the CEA microchannel, and their force balancing determines whether the particles cross the channel, following Dean flows. Here we describe the physics and design of the CEA microfluidic device, and demonstrate complete separation of microparticles (polystyrene beads of 4 and 10 μm in diameter) and efficient exchange of the carrier medium while retaining 10 μm beads.  相似文献   

8.
Lab-on-chip devices are widely being used for binary and ternary cell/particle separation applications. Among the lab-on-chip methods, dielectrophoresis (DEP) is a cost-effective and label-free method, with great capabilities for size-based separation of cells and particles, which is mostly performed in sheath-assisted forms. However, the elimination of the sheath flows offers advantages such as ease of operation and higher sample throughput. In this work, we present a comparison of sheath-assisted and sheathless DEP separation of three sizes of microparticles using tilted electrodes. The sheath-assisted design was capable of separating the 5, 10, and 15 μm particles with a separation efficiency as high as 98.0% for 15 μm particles. By adding a DEP focusing region, a sheathless DEP separator was proposed, which offered higher throughputs (up to 10 times) at the cost of lowering the separation efficiency (a reduction up to 10.3% for 15 μm) compared to the sheath-assisted design. To enhance the separation efficiency, a combination of the DEP focusing accompanied by weak sheath flows from both sides was proposed. This design achieved the highest sample separation yield in the outlets (as high as 98.7% for 15 μm) with a sample throughput of more than 4.2 μL/min. This study provides insights into the choice of an appropriate platform for any application in which the yield, purity, throughput, and portability must be considered.  相似文献   

9.
A novel scheme for particle separation with insulator‐based dielectrophoresis (iDEP) was developed. This technique offers the capability for an inverted order in particle elution, where larger particles leave the system before smaller particles. Asymmetrically shaped insulating posts, coupled with direct current (DC) biased low‐frequency alternating current (AC) electric potentials, were used to successfully separate a mixture of 500 nm and 1 μm polystyrene particles (size difference of 0.5 μm in diameter). In this separation, the 1 μm particles were eluted first, demonstrating the discriminatory potential of this methodology. To extend this technique to biological samples, a mixture containing Saccharomyces cerevisiae cells (6.3 μm) and 2 μm polystyrene particles was also separated, with the cells being eluted first. The asymmetric posts featured a shorter sharp half and a longer blunt half; this produced an asymmetry in the forces exerted on the particles. The negative DC offset produced a net displacement of the smaller particles toward the upstream direction, while the post asymmetry produced a net displacement of the larger particles toward the downstream direction. This new iDEP approach provides a setup where larger particles are quickly concentrated at the outlet of the post array and can be released first when in a mixture with smaller particles. This new scheme offers an extra set of parameters (alternating current amplitude, DC offset, post asymmetry, and shape) that can be manipulated to obtain a desired separation. This asymmetric post iDEP technique has potential for separations where it is important to quickly elute and enrich larger and more fragile cells in biological samples.  相似文献   

10.
We propose herein an improved microfluidic system for continuous and precise particle separation. We have previously proposed a method for particle separation called "pinched flow fractionation." Using the previously reported method, particles can be continuously separated according to differences in their diameters, simply by introducing liquid flows with and without particles into a specific microchannel structure. In this study, we incorporated PDMS membrane microvalves for flow rate control into the microfluidic device to improve the separation accuracy. By adjusting the flow rates distributed to each outlet, target particles could be precisely collected from the desired outlet. We succeeded in separating micron and submicron-size polymer particles. This method can be used widely for continuous and precise separation of various kinds of particles, and can function as an important part of microfluidic systems.  相似文献   

11.
A versatile system with a slurry-packed capillary column was developed for supercritical fluid chromatography, which is capable of programming both inlet and outlet pressure independently, as well as using a restrictor to apply back pressure. This system revealed the relationships between pressure drop, flow rate, and linear velocity in pressure-programmed supercritical fluid chromatography. In the restrictor system, both the pressure drop and the flow rate increased almost linearly with inlet pressure, while under conditions of constant pressure drop characteristic behavior was observed which depended on the density-viscosity relationships of supercritical fluid. Resolution in the separation of polysiloxane oligomers was found to be increased by increasing the ratio of pressure drop to pressure-programming rate, although the sensitivity decreased due to the increase in peak volume. The system controlling both inlet and outlet pressure has distinct advantages over the restrictor system controlling both inlet and outlet pressure has distinct advantages over the restrictor system in practical in practical operations.  相似文献   

12.
The split-flow thin cell fractionation (SF) is a useful tool for separating colloidal particles or macromolecules into two or more fractions in a preparative scale. In a conventional design, the SF channel is equipped with flow stream-splitters at the inlet and the outlet of the channel, which may cause deterioration of the resolution due to the disturbance in the flow stream by the imperfection of the splitter geometry. In this study, a new splitter-less SF channel was implemented, which was designed to operate only in the full-feed depletion (FFD) mode (FFD-SF). Without the splitters, it was possible to make the channel much larger than conventional ones (about 25 times larger in the channel volume), and thus obtain a much higher sample throughput (TP, amount of the sample that can be processed in a unit time period). The new splitter-less FFD-SF system was tested and optimized using polyurethane (PU) latex spheres, and then applied successfully to a large scale separation of sea sediment. A series of three steps of FFD-SF operations (with each step repeated, and there were 6 steps in total) yielded separation of the sea sediment into four fractions having diameter ranges of larger than 10 µm, between 5 and 10 µm, between 2 and 5 µm, and smaller than 2 µm. TP of the three FFD-SF operations were 37.3, 22.1, and 17.9 kg/h, and the fractionation efficiencies (FE) of the four size fractions were 80.5, 73.7, 79.1 and 86.1%. Results suggest the new splitter-less FFD-SF system could be a useful tool for large scale separation of complex particulates such as environmental particles.  相似文献   

13.
The separation of propylene-propane mixture is an energy intensive operation commercially practiced using cryogenic distillation. The separation by pressure swing adsorption has been studied as an alternative. A fixed-bed pressure swing adsorption yields the heavy component as a pure product. The product recovery and the productivity are not high. In a moving-bed process, because of the counter-current solid-gas contact, the separation achieved is similar to that of the fractionation by distillation. Although the moving-bed operation offers the upper limit for the performance of a cyclic adsorptive process, due to mechanical complexities in the handling of solids the 'simulated' moving-bed is preferred. By moving the inlet and outlet ports of streams located along the length of the bed, a moving-bed process can be realized in a fixed bed. We describe here a 'moving-port' system which permits injection or withdrawal of the fluid along the axial direction in a fixed bed. A fixed bed embedded with the moving-port systems emulates a simulated moving-bed adsorber. The proposed adsorber can fractionate a binary gas mixture into two product streams with high purities. It is similar to the Sorbex process of UOP but does not have the eluent as an additional separating agent. A parametric study indicates that high purity products and a higher productivity by an order of magnitude can be achieved with simulated moving-beds compared to the fixed beds.  相似文献   

14.
A loosely focused light beam is very useful for separating colloidal particles. For micron size colloidal particles suspended in a fluid and irradiated with a laser beam perpendicular to the direction of fluid flow, particles have a retention distance determined by their size and composition, the flow rate of fluid, and characteristics of the laser. An optical differential mobility analyzer for separating colloidal particles using a loosely focused beam is proposed theoretically and the concept of optical mobility is introduced. For the proposed optical differential mobility analyzer, particle trajectories and retention behavior are discussed and a transfer function described by operational parameters is derived. The possibility of separating particles of various sizes and different chemical compositions is discussed. It is proposed that the analyzer can be integrated into a microfluidic lab-on-a-chip system suitable for separating colloidal particles and biological cells at a very high resolution.  相似文献   

15.
流体在微流通道中形成剪切流场(低雷诺数).不同于宏观体系,由于剪切力和表面张力的竞争作用,产生的液滴在微尺度下的微流通道中形成特殊的排列现象---周期性类似“晶格”排列现象.设计了新型流动聚焦型微流控芯片,分析研究在微流体系中液滴周期性图案化排列和转变机理性,液滴排列模式受两方面因素影响:水油两相的流速比值和微通道尺寸.当微通道宽度为250或300 μm时,液滴形成单层分散,双层和单层挤压排列.当微通道宽度为350 μm 时,液滴会形成单层分散到三层排列到双层挤压最后到单层挤压排列.当出口通道宽度增加到400 μm时,甚至出现了液滴四层排列的现象.同时研究了各个液滴排列模式的“转变点”.  相似文献   

16.
Split‐flow thin fractionation is a continuous, flow‐assisted separation technique for sorting macromolecules and particulate matter on a preparative scale. On reducing the thickness of the sample inlet conduit of a gravitational split‐flow thin fractionation channel, size‐sorting performance is found to increase since particles that are continuously fed into the channel can be more rapidly compressed toward the upper wall of the channel. Experiments are carried out by measuring the number percentage of particles eluted at each outlet as a function of different thickness values of the sample inlet conduit. The effects that the total thickness of the gravitational split‐flow thin fractionation channel and the sample feed concentration have on the size‐fractionation performance are examined with the goal of determining the best pinched sample inlet, gravitational split‐flow thin fractionation channel design.  相似文献   

17.
Sintering stainless steel powders was initially used to prepare the inlet frit in fused silica capillaries. The use of such inlet frits and outlet frits sintered by the stationary phase itself in the capillary to retain C18 particles was demonstrated to withstand the long exposure, up to a high pressure of 60 MPa, for packing and the prepare column was stable and robust enough to do the continuous chromatographic operations. Characterization of the inlet and outlet frits by scanning electron micrography showed the fused metal particles formed a porous network in the capillary inlet and the homogenous separation beddings were obtained by slurry packing.  相似文献   

18.
Church C  Zhu J  Xuan X 《Electrophoresis》2011,32(5):527-531
Dielectrophoresis has been widely used to focus, trap, concentrate, and sort particles in microfluidic devices. This work demonstrates a continuous separation of particles by size in a serpentine microchannel using negative dielectrophoresis. Depending on the magnitude of the turn-induced dielectrophoretic force, particles travelling electrokinetically through a serpentine channel either migrate toward the centerline or bounce between the two sidewalls. These distinctive focusing and bouncing phenomena are utilized to implement a dielectrophoretic separation of 1 and 3 μm polystyrene particles under a DC-biased AC electric field of 880 V/cm on average. The particle separation process in the entire microchannel is simulated by a numerical model.  相似文献   

19.
The sensitivity of a microfluidic impedance flow cytometer is governed by the dimensions of the sample analysis volume. A small volume gives a high sensitivity, but this can lead to practical problems including fabrication and clogging of the device. We describe a microfluidic impedance cytometer which uses an insulating fluid to hydrodynamically focus a sample stream of particles suspended in electrolyte, through a large sensing volume. The detection region consists of two pairs of electrodes fabricated within a channel 200 μm wide and 30 μm high. The focussing technique increases the sensitivity of the system without reducing the dimensions of the microfluidic channel. We demonstrate detection and discrimination of 1 μm and 2 μm diameter polystyrene beads and also Escherichia coli. Impedance data from single particles are correlated with fluorescence emission measured simultaneously. Data are also compared with conventional flow cytometry and dynamic light scattering: the coefficient of variation (CV) of size is found to be comparable between the systems.  相似文献   

20.
The flow field-flow fractionation (FIFFF) technique is a promising method for separating and analysing particles and large size macromolecules from a few nanometers to approximately 50 μm. A new fractionation channel is described featuring well defined flow conditions even for low channel heights with convenient assembling and operations features. The application of the new flow field-flow fractionation channel is proved by the analysis of pigments and other small particles of technical interest in the submicrometer range. The experimental results including multimodal size distributions are presented and discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号