首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new family of matrices for DNA sequencing by capillary electrophoresis is presented. These matrices combine easy injection with high sieving performances, due to thermal switching between a low and a high viscosity state through a modest increase in temperature (approximately 20 degrees C). They are constructed from a hydrophilic polymer backbone with grafted lower critical solution temperature (LCST) side chains. The comb-like LCST copolymers are characterized in terms of size of the polymer backbone, the size of LCST side chains and the grafting densities. The dependance of rheological behavior and electrophoretic performance of these copolymers is correlated with their microstructure. Without complete optimization, a resolution of order 0.5, corresponding to a very reasonable limit for read length with current base calling softwares, could be achieved for segments around 800 bases differing by 1 base in less than one hour in a commercial ABI 310 apparatus.  相似文献   

2.
To elucidate the impact of matrix chemical and physical properties on DNA sequencing separations by capillary electrophoresis (CE), we have synthesized, characterized and tested a controlled set of different polymer formulations for this application. Homopolymers of acrylamide and N,N-dimethylacrylamide (DMA) and copolymers of DMA and N,N-diethylacrylamide (DEA) were synthesized by free radical polymerization and purified. Polymer molar mass distributions were characterized by tandem gel permeation chromatography - laser light scattering. Polymers with different chemical compositions and similar molar mass distributions were selected and employed at the same concentration so that the variables of comparison between them were hydrophobicity and average coil size in aqueous solution. We find that the low-shear viscosities of 7% w/v polymer solutions decrease by orders of magnitude with increasing polymer hydrophobicity, while hydrophilic polymers exhibit more pronounced reductions in viscosity with increased shear. The performance of the different matrices for DNA sequencing was compared with the same sample under identical CE conditions. The longest read length was produced with linear polyacrylamide (LPA) while linear poly-N,N-dimethylacrylamide (PDMA) gave approximately 100 fewer readable bases. Read lengths with DMA/DEA copolymers were lower, and decreased with increasing DEA content. This study highlights the importance of polymer hydrophilicity for high-performance DNA sequencing matrices, through the formation of robust, highly-entangled polymer networks and the minimization of hydrophobic interactions between polymers and fluorescently-labeled DNA molecules. However, the results also show that more hydrophobic matrices offer much lower viscosities, enabling easier microchannel loading at low applied pressures.  相似文献   

3.
Buchholz BA  Shi W  Barron AE 《Electrophoresis》2002,23(10):1398-1409
We review the variety of thermo-responsive and shear-responsive polymer solutions with "switchable" viscosities that have been proposed for application as DNA sequencing matrices for capillary and microfluidic chip electrophoresis. Generally, highly entangled polymer solutions of high-molar mass polymers are necessary for the attainment of long DNA sequencing read lengths (> 500 bases) with short analysis times (< 3 h). However, these entangled polymer matrices create practical difficulties for microchannel electrophoresis with their extremely high viscosities, necessitating high-pressure loading into capillaries or chips. Shear-responsive (shear-thinning) polymer matrices exhibit a rapid drop in viscosity as the applied shear force is increased, but still require a high initial pressure to initiate flow of the solution into a microchannel. Polymer matrices designed to have thermo-responsive properties display either a lowered (thermo-thinning) or raised (thermo-thickening) viscosity as the temperature of the solution is elevated. These properties are generally designed into the polymers by the incorporation of moderately hydrophobic groups in some part of the polymer structure, which either phase-separate or hydrophobically aggregate at higher temperatures. In their low-viscosity states, these matrices that allow rapid loading of capillary or chip microchannels under low applied pressure. The primary goal of work in this area is to design polymer matrices that exhibit this responsive behavior and hence easy microchannel loading, without a reduction in DNA separation performance compared to conventional matrices. While good progress has been made, thermo-responsive matrices have yet to offer sequencing performance as good as nonthermo-responsive networks. The challenge remains to accomplish this goal through the innovative design of novel polymer structures.  相似文献   

4.
In an earlier study we showed that a blend of thermoresponsive and nonthermoresponsive hydroxyalkylcelluloses could be used to create a thermally tunable polymer network for double-stranded (ds) DNA separation. Here, we show the generality of this approach using a family of polymers suited to a wider range of DNA separations: a blended mixture of N,N-dialkylacrylamide copolymers with different thermoresponsive behaviors. A mixture of 47% w/w N,N-diethylacrylamide (DEA)/53% w/w N,N-dimethylacrylamide (DMA) (DEA47; thermoresponsive, transition temperature = 55 degrees C in water) and 30% w/w DEA/70% w/w DMA (DEA30; nonthermoresponsive, transition temperature > 85 degrees C in water) copolymers in the ratio of 1:5 w/w DEA47:DEA30 was used to separate a dsDNA restriction digest (PhiX174-HaeIII). We investigated the effects of changing mesh size on dsDNA separation, as controlled by temperature. We observed good DNA separation performance with the copolymer blend at temperatures ranging from 25 degrees C to 48 degrees C. The separation selectivity was evaluated quantitatively for certain DNA fragment pairs as a function of temperature. The results were compared with those obtained with a control matrix consisting only of the nonthermoresponsive DEA30. Different DNA fragment pairs of various sizes show distinct temperature-dependent selectivities. Over the same temperature range, no significant temperature dependence of selectivity is observed for these DNA fragment pairs in the nonthermoresponsive control matrix. Overall, the results show similar trends in the temperature dependency of separation selectivity to what was previously observed in hydroxyalkylcellulose blends, for the same DNA fragment pairs. Finally, we showed that a ramped temperature scheme enables improved separation in the blended copolymer matrix for both small and large DNA fragments, simultaneously in a single capillary electrophoresis (CE) run.  相似文献   

5.
The novel polymer matrices reported here are low-viscosity sieving media for DNA capillary electrophoresis. This new family of matrices comprises copolymers of N,N-dimethylacrylamide with different monomers which increase polymer hydrophilicity. All these new copolymers self-coat on fused-silica capillaries. Resolution, peak spacing and peak width were the parameters taken into account to assess the influence of polymer structure on separation selectivity and efficiency. This work demonstrates that the performance of polydimethylacrylamide (PDMA) can be improved through copolymerization with hydrophilic monomers. The improvement is related to the efficiency parameter. The new copolymers, due to their low viscosity high sieving capacity and ability to suppress EOF, represent a better alternative to PDMA and are suitable replaceable matrices for capillary and microchip electrophoresis.  相似文献   

6.
Buchholz BA  Barron AE 《Electrophoresis》2001,22(19):4118-4128
The ability of a polymer matrix to separate DNA by capillary electrophoresis (CE) is strongly dependent upon polymer physical properties. In particular, recent results have shown that DNA sequencing performance is very sensitive to both the average molar mass and the average coil radius of the separation matrix polymers, which are affected by both polymer structure and polymer-solvent affinity. Large polymers with high average molar mass provide the best DNA sequencing separations for CE, but are also the most challenging to characterize with accuracy. The methods most commonly used for the characterization of water-soluble polymers with application in microchannel electrophoresis have been gel permeation chromatography (GPC) and intrinsic viscosity measurements, but the limitations and potential inaccuracies of these approaches, particularly for large or novel polymers and copolymers, press the need for a more universally accurate method of polymer molar mass profiling for advanced DNA separation matrices. Here, we show that multi-angle laser light scattering (MALLS) measurements, carried out either alone or in tandem with prior on-line sample fractionation by GPC, can provide accurate molar mass and coil radius information for polymer samples that are useful for DNA sequencing by CE. Wider employment of MALLS for characterization of novel polymers designed as DNA separation matrices for microchannel electrophoresis should enable more rapid optimization of matrix properties and formulation, and assist in the development of novel classes of polymer matrices.  相似文献   

7.
A thermo-responsive separation matrix, consisting of Pluronic F127 tri-block copolymers of poly(ethylene oxide) and poly(propylene oxide), was used to separate DNA fragments by microchip electrophoresis. At low temperature, the polymer matrix was low in viscosity and allowed rapid loading into a microchannel under low pressure. With increasing temperatures above 25°C, the Pluronic F127 solution forms a liquid crystalline phase consisting of spherical micelles with diameters of 17–19 nm. The solution can be used to separate DNA fragments from 100 bp to 1500 bp on poly(methyl methacrylate) (PMMA) chips. This temperature-sensitive and viscosity-tunable polymer provided excellent resolution over a wide range of DNA sizes. Separation is based on a different mechanism compared with conventional matrices such as methylcellulose. To illustrate the separation mechanism of DNA in a Pluronic F127 solution, DNA molecular imaging was performed by fluorescence microscopy with F127 polymer as the separation matrix in microchip electrophoresis. Figure Temperature dependence of the viscosity of 20% w/w Pluronic F127 solution in 1xTBE buffer. Dotted approximates resultant curve.  相似文献   

8.
Read length in DNA sequencing by capillary electrophoresis at elevated temperatures is shown to be greatly affected by the extent of hydrophobicity of the polymer separation matrix. At column temperatures of up to 80 degrees C, hydrophilic linear polyacrylamide (LPA) provides superior read length and separation speed compared to poly(N,N-dimethylacrylamide) (PDMA) and a 70:30 copolymer of N,N-dimethylacrylamide and N,N-diethylacrylamide (PDEA30). DNA-polymer and polymer intramolecular interactions are presumed to be a major cause of band broadening and the subsequent loss of separation efficiency with the more hydrophobic polymers at higher column temperatures. With LPA, these interactions were reduced, and a read length of 1000 bases at an optimum temperature of 70 degrees -75 degrees C was achieved in less than 59 min. By comparison, PDMA produced a read length of roughly 800 bases at 50 degrees C, which was close to the read length attained in LPA at the same temperature; however, the migration time was approximately 20% longer, mainly because of the higher polymer concentration required. At 60 degrees C, the maximum read length was 850 bases for PDMA, while at higher temperatures, read lengths for this polymer were substantially lower. With the copolymer DEA30, read length was 650 bases at the optimum temperature of 50 degrees C. Molecular masses of these polymers were determined by tandem gel permeation chromatography-multiangle laser light scattering method (GPC-MALLS). The results indicate that for long read, rapid DNA sequencing and analysis, hydrophilic polymers such as LPA provide the best overall performance.  相似文献   

9.
Song L  Liang D  Fang D  Chu B 《Electrophoresis》2001,22(10):1987-1996
Poly(N,N-dimethylacrylamide) (PDMA) with a molecular mass of 5.2 x 10(6) g/mol has been synthesized and used in DNA sequencing analysis by capillary electrophoresis (CE). A systematic investigation is presented on the effects of different separation conditions, such as injection amount, capillary inner diameter, polymer concentration, effective separation length, electric field and temperature, on the resolution. DNA sequencing up to 800 bases with a resolution (R) limit of 0.5 (and 1,000 bases with a resolution limit of 0.3) and a migration time of 96 min was achieved by using 2.5% w/v polymer, 150 V/cm separation electric field, and 60 cm effective separation length at room temperature on a DNA sample prepared with FAM-labeled--21M13 forward primer on pGEM3Zf(+) and terminated with ddCTP. Ultrafast and fast DNA sequencing up to 420 and 590 bases (R > or = 0.5) were also achieved by using 3% w/v polymer and 40 cm effective separation length with a separation electric field of 525 and 300 V/cm, and a migration time of 12.5 and 31.5 min, respectively. PDMA has low viscosity, long shelf life and dynamic coating ability to the glass surface. The unique properties of PDMA make it a very good candidate as a separation medium for large-scale DNA sequencing by capillary array electrophoresis (CAE).  相似文献   

10.
Copolymers of acrylamide (AM) and N,N-dimethylacrylamide (DMA) with AM to DMA molar ratios of 3:1, 2:1 and 1:1 and molecular weights of about 2.2 MDa were synthesized. The polymers were tested as separation media in DNA sequencing analysis by capillary electrophoresis (CE). The dynamic coating ability of polydimethylacrylamide (PDMA) and the hydrophilicity of polyacrylamide (PAM) have been successfully combined in these random copolymers. A separation efficiency of over 10 million theoretical plates per meter has been reached by using the bare capillaries without the additional polymer coating step. Under optimized separation conditions for longer read length DNA sequencing, the separation ability of the copolymers decreased with decreasing AM to DMA molar ratio from 3:1, 2:1 and 1:1. In comparison with PAM, the copolymer with a 3:1 AM:DMA ratio showed a higher separation efficiency. By using a 2.5% w/v copolymer with 3:1 AM:DMA ratio, one base resolution of 0.55 up to 699 bases and 0.30 up to 963 bases have been achieved in about 80 min at ambient temperatures.  相似文献   

11.
Ethylene-propylene copolymers and hydrogenated styrene-diene copolymers were used for a comparative study aiming at their application as viscosity index improvers in multigrade engine oils. The variation of viscosity with temperature has been evaluated as a function of the polymer concentrations. The thickening effect of different viscosity index improvers and the dependence of reduced viscosities on temperature were determined. At concentrations lower than 3% (w/w) the viscosity/temperature characteristic suggested the occurrence of polymer coil expansion with temperature for hydrogenated styrene-diene copolymer. The direct dependence of mechanical stability on the copolymer molecular weight was observed.  相似文献   

12.
Xu F  Baba Y 《Electrophoresis》2004,25(14):2332-2345
We give an overview of recent development of low-viscosity polymer solutions and entropic trapping networks for double-stranded DNA (dsDNA) separations by conventional capillary electrophoresis and microchip electrophoresis. Theoretical models for describing separation mechanisms, commonly used noncross-linked polymer solutions, thermoresponsive (viscosity-adjustable) polymer solutions, and novel entropic trapping networks are included. The thermoresponsive polymer solutions can be loaded at one temperature into microchannels at lower viscosities, and used in separation at another temperature at entanglement threshold concentrations and higher viscosities. The entropic-based separations use only arrays of regular obstacles acting as size-separations and do not need viscous polymer solutions. These progresses have potential in integration to automated capillary and microfluidic chip systems, enabling better reusability of separation microchannels, much shorter DNA separation times, and higher reproducibility due to less matrix degradation.  相似文献   

13.
Sparsely cross-linked "nanogels" for microchannel DNA sequencing   总被引:1,自引:0,他引:1  
Doherty EA  Kan CW  Barron AE 《Electrophoresis》2003,24(24):4170-4180
We have developed sparsely cross-linked "nanogels", sub-colloidal polymer structures composed of covalently linked, linear polyacrylamide chains, as novel DNA sequencing matrices for capillary electrophoresis. The presence of covalent cross-links affords nanogel matrices with enhanced network stability relative to standard, linear polyacrylamide (LPA), improving the separation of large DNA fragments. Nanogels were synthesized via inverse emulsion (water-in-oil) copolymerization of acrylamide and N,N-methylenebisacrylamide (Bis). In order to retain the fluidity necessary in a replaceable polymer matrix for capillary array electrophoresis (CAE), a low percentage of the Bis cross-linker (< 10(-4) mol%) was used. Nanogels were characterized by multiangle laser light scattering and rheometry, and were tested for DNA sequencing by CAE with four-color laser-induced fluorescence (LIF) detection. The properties and performance of nanogel matrices were compared to those of a commercially available LPA network, which was matched for both weight-average molar mass (Mw) and extent of interchain entanglements (c/c*). Nanogels presented in this work have an average radius of gyration of 226 nm and a weight-average molar mass of 8.8 x 10(6) g/mol. At concentrations above the overlap threshold, nanogels form a clear, viscous solution, similar to the LPA matrix (Mw approximately 8.9 x 10(6) g/mol). The two matrices have similar flow and viscosity characteristics. However, because of the physical network stability provided by the internally cross-linked structure of the nanogels, a substantially longer read length ( approximately 63 bases, a 10.4% improvement) is obtained with the nanogel matrix at 98.5% accuracy of base-calling. The nanogel network provides higher-selectivity separation of ssDNA sequencing fragments longer than 375 bases. Moreover, nanogel matrices require 30% less polymer per unit volume than LPA. This is the first report of a sequencing matrix that provides better performance than LPA, in a side-by-side comparison of polymer matrices matched for Mw and extent of interchain entanglements.  相似文献   

14.
In spite of the significant progresses in the field of replaceable sieving matrices for separating DNA in capillary electrophoresis (CE), an intense research activity is still going on to improve the separation of large size DNA sequencing fragments. There are evidences, both from experimental and theoretical sides that the resolution of these fragments, at the single base, requires the use of sieving matrices comprised of long chain linear polymers. In the separation of DNA fragments by CE are of upmost importance: (i) the complete solubility of the polymer, (ii) the linearity of the chain, (iii) the achievement of ultrahigh viscosity in dilute solutions. The aim of this work is the synthesis of ultrahigh-molecular-weight polymers which possess the three requirements mentioned above by employing a nonconventional method. We demonstrate that the sieving performance of polyacrylamide is directly correlated to its intrinsic viscosity.  相似文献   

15.
Kan CW  Barron AE 《Electrophoresis》2003,24(1-2):55-62
We present a "proof-of-concept" study showing that a blend of thermo-responsive and nonthermo-responsive polymers can be used to create a DNA sieving matrix with a thermally tunable mesh size, or "dynamic porosity". Various blends of two well-studied sieving polymers for CE, including hydroxypropylcellulose (HPC), a thermo-responsive polymer, and hydroxyethylcellulose (HEC), a nonthermo-responsive polymer, were used to separate a double-stranded DNA restriction digest (Phi X174-HaeIII). HPC exhibits a volume-phase transition in aqueous solution which results in a collapse in polymer coil volume at approximately 39 degrees C. Utilizing a blend of HPC and HEC in a ratio of 1:5 by weight, we investigated the effects of changing mesh size on DNA separation, as controlled by temperature. High-resolution DNA separations were obtained with the blended matrix at temperatures ranging from 25 degrees C to 38 degrees C. We evaluated changes in the selectivity of DNA separation with increasing temperature for certain pairs of small and large fragments. A pure HEC (nonthermo-responsive) matrix was used over the same temperature range as a negative control. In the blended matrix, we observe a maximum in selectivity at approximately 31 degrees C for small DNA, while a significant increase in the selectivity of large-DNA separation occurs at approximately 36 degrees C as the polymer mesh "opens". We also demonstrate, through a temperature ramping experiment, that this matrix can be utilized to obtain high-resolution separation of both small and large DNA fragments simultaneously in a single CE run. Blended polymer matrices with "dynamic porosity" have the potential to provide enhanced genomic analysis by capillary array or microchip electrophoresis in microfluidic devices with advanced temperature control.  相似文献   

16.
Cretich M  Chiari M  Pirri G  Crippa A 《Electrophoresis》2005,26(10):1913-1919
Adsorbed polymers are widely used to suppress electroosmotic flow (EOF) in capillary electrophoresis (CE). Polymeric coatings, physisorbed onto the surface of the capillary wall, are often unstable under harsh conditions. This can be attributed to the reversible nature of the coating which becomes apparent when the adsorbed layer competes with a second species in the electrophoresis buffer solution for attachment/interaction with the capillary surface. In an effort to overcome the problem of coating instability, trimethoxysilane-modified polydimethylacrylamide was synthesized. This copolymer rapidly adsorbs on the wall from ultradilute aqueous solutions. After incubation at a temperature of 60 degrees C silyl groups, which extend from the polymer backbone, form condensation bonds with the silanols on the capillary surface. This enables subsequent formation of strong covalent bonds between the copolymer and the capillary wall. In this research, we establish that physisorption of polymer chains to the surface is essential for close alignment of surface and polymer silane groups which facilitates the formation of covalent bonds.  相似文献   

17.
Block copolymers composed of hydrophilic poly(ethylene glycol) (PEG) and hydrophobic biodegradable polyesters have been reported as thermogelling polymers, because they feature temperature-dependent sol-to-gel or gel-to-sol transitions in aqueous solutions. In this study, a series of thermogelling poly(ethylene glycol methyl ether)-block–poly(cyclohexylenedimethylene adipate)-block–poly(ethylene glycol methyl ether) triblock copolymers and PEG-block–poly(cyclohexylenedimethylene adipate) multiblock copolymers was synthesized by reacting hydroxyl-terminated poly(cyclohexylenedimethylene adipate) (PCA) with poly(ethylene glycol methyl ether) and PEG, respectively, using 1,6-diisocyanatohexane as the coupling agent. Two hydroxyl-terminated PCAs, i.e., poly(1,4-cyclohexylenedimethylene adipate) and poly(1,3/1,4-cyclohexylenedimethylene adipate), were synthesized by the condensation reaction of adipic acid (AA) with 1,4-cyclohexanedimethanol (CHDM) and 1,3/1,4-CHDM, respectively, and used as the hydrophobic polyester blocks of these thermogelling copolymers to compare the effect of crystallinity on the sol-to-gel transition behavior.The polymers were characterized using proton nuclear magnetic resonance, Fourier transform infrared spectroscopy, gel permeation chromatography, differential scanning calorimetry, solubility testing, and rheological analysis. Experimental results revealed that the structure of the PCA block (crystalline vs. amorphous), the molecular weights of the hydrophobic PCA and hydrophilic PEG blocks, and the type of thermogelling polymer (triblock vs. multiblock) influenced the solubility, polymer micelle packing characteristics, maximum storage modulus, and sol-to-gel temperature of the polymers. Among all the samples at 40 wt.% aqueous solutions, triblock copolymer TB3 showed sol-to-gel temperature at 22 °C, and had the highest maximum storage modulus about 170 Pa.  相似文献   

18.
Kotler L  He H  Miller AW  Karger BL 《Electrophoresis》2002,23(17):3062-3070
The goal of this work was to reduce the capillary electrophoresis (CE) separation time of DNA sequencing fragments with linear polyacrylamide solutions while maintaining the previously achieved long read lengths of 1000 bases. Separation speed can be increased while maintaining long read lengths by reducing the separation matrix viscosity and/or raising the column temperature. As urea is a major contributor to the separation buffer viscosity, reducing its concentration is desirable both for increase in the separation speed and easier solution replacement from the capillary. However, at urea concentrations below 6 M, the denaturing capacity of the separation buffer is not sufficient for accurate base-calling. To restore the denaturing properties of the buffer, a small amount of an organic solvent was added to the formulation. We found that a mixture of 2 M urea with 5% v/w of dimethyl sulfoxide (DMSO) resulted in 975 bases being sequenced at 70 degrees C in 40 min with 98.5% accuracy. To achieve this result, the software was modified to perform base-calling at a peak resolution as low as 0.24. It is also demonstrated that the products of thermal decomposition of urea had a deleterious effect on the separation performance at temperatures above 70 degrees C. With total replacement of urea with DMSO, at a concentration of 5% v/w in the same linear polyacrylamide (LPA)-containing buffer, it was possible to increase the column temperature up to 90 degrees C. At this temperature, up to 951 bases with 98.5% accuracy could be read in only 32 min of separation. However, with DMSO alone, some groups of C-terminated peaks remained compressed, and column temperature at this level cannot at present be utilized with existing commercial instrumentation.  相似文献   

19.
New copolymers of acrylamide and β-D -glucopyranoside were synthesized and characterized. The different reactivity of the two monomers towards radical polymerization meant we could control the growth of the polymer chains whose length was inversely related to the number of glucose residues incorporated in the copolymers. The properties of these polymers were investigated in the separation of oligonucleotides and double-stranded DNA by capillary electrophoresis (CE) in coated and uncoated capillaries. The new copolymers were a suitable matrix for CE due to their high-resolving capacity and low viscosity. We also looked into the advantages of a new method of dynamic suppression of electroosmotic flow based on the addition of small amounts (0.03–0.05%) of dimethylacrylamide to the sieving and to the running buffer. A complete test was run on the reproducibility and efficiency of separations carried out in a permanently and dynamically coated capillary, and the advantages and disadvantages of the two methods were compared.  相似文献   

20.
We have synthesized two new sugar monomers, allylamine of gluconic and lactobionic acid, by opening the corresponding lactone ring with allylamine. These monomers were copolymerized with acrylamide leading to formation of copolymers with a relative molecular mass of 288000 and 180000 Da, respectively. Double-stranded DNA fragments were separated in entangled solutions of these linear polymers in capillary electrophoresis. Resolution, peak spacing and peak width were the parameters taken into account to evaluate the quality of the separation achieved with the new polymers. This work indicates that the copolymers of acrylamide and allyl gluconic acid have a high sieving capacity and provide a performance similar to that of hydroxyethylcellulose (HEC) of comparable viscosity. Unlike HEC, this copolymer selfcoats onto the capillary wall, allowing DNA fragments to be efficiently separated in an uncoated capillary.  相似文献   