A miniaturized capillary electrophoresis (CE) system with UV-Vis detection was coupled to a flow injection (FI) system for achieving high throughput continuous sample introduction. The cassette of a commercial CE instrument was modified to hold a 6.5 cm long silica capillary and a flow-through waste reservoir. The cassette was inserted into the flow-cell chamber of a commercial UV detector, with the light beam focused on the capillary and collected by two ball lenses on the cassette. The capillary inlet, left outside the cassette and detector, was positioned on the top of a vertical 3.5 mm diameter glass rod, in close contact with an electrode. Samples injected through the FI system dropped freely on top of the pillar, covering the capillary inlet and electrode. Continuous sample introduction was achieved for CE separations under non-interrupted separation voltage, which was isolated from the FI system through the discontinuity of droplets. The newly developed interface and UV detection system was used for fast separation of sulphamethoxazole (SMZ) and trimethoprim (TMP) in sulphatrim tablets, achieving a high throughput of over 48 h−1, and a low carryover of 2%. Separation efficiencies of 8 μm plate height and detection limits of 1.0 mg l−1 for SMZ and 0.5 mg l−1 (3σ) for TMP were obtained.  相似文献   

2.
A microchip-based capillary electrophoresis device supported by a microfluidic network made of poly(dimethylsiloxane), used for measuring target analytes from a continuous sample flow, is presented. The microsystem was fabricated by means of replica molding in combination with standard microfabrication technologies, resulting in microfluidic components and an electrochemical detector. A new hydrodynamic sample injection procedure is introduced, and the maximum number of consecutive measurements that can be made with a poly(dimethylsiloxane) capillary electrophoresis chip with amperometric detection is investigated with respect to reproducibility. The device features a high degree of functional integration, so the benefits associated with miniaturized analysis systems apply to it.  相似文献   

3.
Measurements by capillary flow injection analysis (CFIA) and capillary electrophoresis (CE) in conjunction with electrochemical detection are described. The detection is based on an end-column electrode arrangement. Several novel electrodes, such as a spherical gold electrode and a dual-microdisk electrode, are presented and characterized regarding their analytical utility. In order to improve the selectivity of CFIA, dual-electrode and multiple-pulse detection are studied using couples of cyanometallates or metallocenes. Capillary electrophoretic experiments with amperometric detection are performed using 50 m i.d. capillaries without any electrical-field decoupler. The practicality and analytical characteristics of this detection strategy are illustrated for the separation of serotonin and some biological precursors and metabolites of neurotransmitter substances.  相似文献   

4.
The performance of an integrated capillary electrophoresis system with a novel split-flow sample injection mechanism and special high sensitivity UV absorbance detector is described. Sample introduction into the capillary is accomplished with a standard HPLC-type microliter syringe. The injected sample is divided proportionally between the separation capillary and an adjustable splitvent. The volume of sample introduced into the capillary can be manipulated by varying the length or the i.d. of the splitvent tubing; or the volume of sample injected. Data are presented showing reproducibility of retention time, peak height, and peak area; minimum detectability; and operation at short UV wavelengths.  相似文献   

5.
In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis.  相似文献   

6.
The combined flow injection (FI)-capillary electrophoresis (CE) system was further exploited by coupling to an electrogenerated chemiluminescence (ECL) detection system. A low-cost miniaturized CE system was developed on a chip platform to provide easy interface both with FI sample introduction and with ECL detection. A falling-drop interface was employed to perform FI split-flow sample introduction while achieving electrical isolation from the CE high voltage. A plexiglas reservoir at the capillary outlet served as both the reaction and detection cell for the ECL reaction, with Ru(bpy)32+ reagent continuously flowing through the cell. An optical fiber was positioned within the reservoir close to the capillary outlet for transferring the ECL emission to the PMT. The relative positions of the capillary outlet, working electrode and optical fiber as well as reagent renewal flow-rate were optimized to achieve both good sensitivity and separation efficiency under non-interrupted sampling conditions, involving large numbers of samples. An on-column joint often used in other works for isolating the ECL detection system from the CE separation voltage was not found necessary. The performance of the system was illustrated by the baseline separation of proline, valine and phenylalanine with a high throughput of 50 h−1 and plate height of 14 μm for proline under 147 V cm−1 field strength. Detection limits (3σ) were 1.2, 50 and 25 μM and peak height precisions were 1.4, 5.4 and 4.3% R.S.D. (n=9) for proline, valine and phenylalanine, respectively.  相似文献   

7.
A sequential injection micro-sample introduction system was coupled to a microfluidic-chip based capillary electrophoresis system through a split–flow sampling interface integrated on the micro-chip. The microfluidic system measured 20×70×3 mm in dimension, and was produced using a non-lithographic approach with components readily available in the analytical laboratory. In the H-configuration channel design the horizontal separation channel was a 75 μm I.D.×60 mm quartz capillary, with two vertical side arms produced from plastic tubing. The conduits were embedded in silicon elastomer with a planar glass base. Sequential introduction of a series of samples with about 2.5% carryover was achieved at 48 h−1 throughput with samples containing a mixture of fluorescein isothiocyanate (FITC)-labeled amino acids using SI sample volumes of 3.3 μl and carrier flow-rate of 2.0 ml min−1. Baseline separation was achieved for FITC-labeled arginine, phenylalanine, glycine and FITC (laser induced fluorescence detection) in sodium tetraborate buffer (pH 9.2) within 8–80 s, at separation lengths of 25–35 mm and electrical field strengths of 250–1500 V cm−1, with plate heights in the 0.7–3 μm range.  相似文献   

8.
The ability to accurately inject small volumes of sample into microfluidic channels is of great importance in electrophoretic separations. While electrokinetic injection of nanoliter scale volumes is commonly utilized in microchip capillary electrophoresis (MCE), mobility and matrix bias makes quantitation difficult. Herein, we describe a new injection method based on the simple patterning of the crossing of channels that does not require sophisticated instrumentation. The sample volume injected into the separation channel is dependent on the ratio of the widths of the crossing channels. This injection method is capable of introducing, into a separation channel, multiple plugs of sample on a large scale. This injection technique is tested for zone electrophoresis in native and surface modified poly(dimethylsiloxane) (PDMS) chips.  相似文献   

9.
The emission produced by sulfite on oxidation by permanganate in acidic solution in the presence of riboflavin phosphate or brilliant sulfaflavine is used to determine 0.9–35 ng of sulfite. Only sulfide and thiosulfate also give emissions.  相似文献   

10.
A procedure for separation and quantitation of methylmercury by capillary electrophoresis using sample stacking as the injection technique is presented. The CE conditions have been optimized in order to separate the methylmercury from the excess cysteine peak and to concentrate large volumes of sample obtaining a low detection limit. Under the proposed operational conditions, the detection limit (S/N = 3) was 12 ng g and the limit of quantitation (S/N = 10) was 20 ng g−1 with a linear range of 20–100 ng g−1 (as methylmercury in samples). The method was tested using different reference materials with a certified methylmercury content.  相似文献   

11.
H C Tsai  C W Whang 《Electrophoresis》1999,20(12):2533-2538
A capillary electrophoresis (CE)/indirect chemiluminescence (CL) detection method is described for monoamines, viz., serotonin (5-HT), dopamine (DA), epinephrine (EP), and norepinephrine (NE) and for catechol (CA). Optimal separation and detection were obtained with an electrophoretic buffer of 10 mM sodium borate (pH 9.5) containing 5 mM luminol and 25 mM H2O2, and a catalyst solution of 30 microM CuSO4 in 30 mM borate buffer (pH 10.0). Complete separation of 5-HT, DA, EP, NE and CA was achieved in less than 5 min. The Cu(II)-catalyzed luminol CL reaction was employed to provide the high and constant background. Since monoamines and catechol can form stable complexes with Cu(II), inverted analyte peaks due to decreased catalytic activity of Cu(II) can be detected. The degree of CL suppression is proportional to the analyte concentrations. Linearity (r> or =20.99) over two orders of magnitude was generally obtained. The concentration limits of detection (CLODs) for the monoamines and catechol studied were between 0.5 and 3.1 uM. The relative standard deviation (RSD) values on peak size and migration time were in the ranges 3.2-4.4% and 0.4-0.5%, respectively. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

12.
Shen H  Fang Q  Fang ZL 《Lab on a chip》2006,6(10):1387-1389
A microfluidic chip-based sequential injection system with trapped droplet liquid-liquid extraction preconcentration and chemiluminescence detection was developed for achieving high sensitivity with low reagent and sample consumption. The microfabricated glass lab-chip had a 35 mm long extraction channel, with 134 shrunken opening rectangular recesses (L 100 microm x W 50 microm x D 25 microm) arrayed within a 1 mm length on both sides of the middle section of the channel. Ketonic peroxyoxalate ester solution was filled in the recesses forming organic droplets, and keeping the aqueous sample solution flowing continuously in the extraction channel; analytes were transferred from the aqueous phase into the droplets through molecular diffusion. After liquid-liquid extraction preconcentration, catalyst and hydrogen peroxide solutions were introduced into the channel, and mixed with analytes and peroxyoxalate ester to emit chemiluminescence light. The performance of the system was tested using butyl rhodamine B, yielding a precision of 4% RSD (n = 5) and a detection limit of 10(-9) M. Within a 17 min analytical cycle, the consumptions of sample and peroxyoxalate solutions were 2.7 microL and 160 nL, respectively.  相似文献   

13.
Liu YM  Cheng JK 《Electrophoresis》2002,23(4):556-558
Field-amplified sample injection of copper(II) was investigated using capillary electrophoresis with chemiluminescence detection. The sensitivity of copper(II) has been improved markedly by the field-amplified sample injection technique and the detection limit reaches 2 x 10(-11) M. By injection of a short plug of water before sample introduction, the sensitivity can be further improved 5-fold and the detection limit reaches 4 x 10(-12) M. The relative standard deviations (n = 6) of the migration time and the peak height are 0.61% and 4.7% at 1.0 x 10(-9) M Cu(II), respectively. Parameters affecting the field-amplified sample injection, such as separation voltage and concentration of electrophoretic buffer, have been investigated.  相似文献   

14.
15.
We developed a capillary electrophoresis with chemiluminescence detection system using 2-methyl-6-p-methoxyphenylethynylimidazopyrazinone as a chemiluminescence reagent for determination of antioxidants of superoxide anions. 2-Methyl-6-p-methoxyphenylethynylimidazopyrazinone reacted with superoxide anions generated through the reaction of hypoxanthine and xanthine oxidase, and then emitted chemiluminescence. Suppression of the chemiluminescence in the presence of antioxidants for superoxide anions was introduced as a detection principle for antioxidants into the capillary electrophoresis with chemiluminescence detection system. After optimizing the analytical conditions, various antioxidants, such as superoxide dismutase, nitroblue tetrazolium, ascorbic acid, and catechin, were subjected to the present system. They gave negative peaks due to the quenching effect; the detection limits of superoxide dismutase, nitroblue tetrazolium, ascorbic acid, and catechin were 1, 100, 100, and 10 μM, respectively (S/N = 2). A model sample consisting of superoxide dismutase and nitroblue tetrazolium was satisfactorily separated and detected within ca. 10 min. We also applied the present system to analysis of catechin in green tea as a real sample.  相似文献   

16.
Tetracycline hydrochloride (4 × 10?5?1 × 10?3M) in a 40-μl aqueous sample is determined in a flow system by measurement of the chemiluminescence emitted on reaction with bromine (9.3 × 10?3 M) at pH 10.4 (carbonate buffer). The limit of detection is 1.6 nmol per 40-μl injection.  相似文献   

17.
Suqin Han 《Analytical sciences》2005,21(11):1371-1374
A capillary electrophoresis with chemiluminescence method has been developed for the determination of rutin and chlorogenic acid based on its enhancing effect on the luminol-ferricyanide system. Under the optimum conditions, the analytes could be separated within 5 min, and the detection limits of the proposed method were 0.22 microg/ml for rutin and 0.50 microg/ml for chlorogenic acid, respectively. The method was successfully applied to the analysis of rutin and chlorogenic acid in real samples.  相似文献   

18.
Su R  Lin JM  Uchiyama K  Yamada M 《Talanta》2004,64(4):1024-1029
A glass electrophoresis microchip integrated a flow-type chemiluminescence (CL) detection cell has been developed and evaluated. The chip pattern is a double-T-type electrophoretic sample injection and separation combining with a Y-type chemiluminecent detector. The double-T geometry allows for high-efficiency sample injection and geometric definition of sample plug size. The branch of Y was used as CL reagent channel, and the CL reagent was delivered by a lab-made micropump. Bis[(2,4,6-trichlorophenyl)]oxalate-H2O2 CL system was employed to detect dansyl amino acids. On this microchip, dansyl-phenylalanine and -sarcosine were successfully separated by electrophoresis and detected within 250 s. The detection limits (S/N=3) of dansyl-phenylalanine and -sarcosine could reach to 2.8 and 3.2 μM, respectively, due to the vigorous dilution of sample with CL reagent and timely removal of the waste solution from reaction area.  相似文献   

19.
A flow injection analysis-capillary electrophoresis system has been used for on-line flow stacking of 11 US Environmental Protection Agency priority phenol pollutants. Samples containing low concentrations of phenols dissolved in deionised water are continuously delivered to the capillary opening by means of a peristaltic pump. The sample components stack at the boundary between the highly conductive separation electrolyte and the introduced sample. By selecting an appropriate electrolyte and stacking conditions the movement of the electrolyte solution inside the capillary can be reduced, thereby improving the stacking efficiency. The electrolyte used here contained 20 mM phosphate, 8% 2-butanol, and 0.001% hexamethonium bromide at pH 11.95, and the stacking was carried out at 2 kV for 240 s. These conditions allowed up to 2000-fold preconcentration of the selected phenols. No matrix removal was necessary.  相似文献   

20.
Jin W  Dong Q  Yu D  Ye X  Li W 《Electrophoresis》2000,21(8):1540-1544
A capillary electrophoresis (CE)/electrochemical detection system with on-line deoxygenation was developed, consisting of a deoxygenation injector, a deoxygenation protector, and an electrochemical detection cell. When the system was utilized for 60 min, the steady-state current of oxygen detected could be dropped to 3% of the original value for the gold/mercury amalgam electrode and to 8% of the original value for the gold electrode, and the limit of detection could be decreased two orders of magnitude for the reducible analytes such as TI+ (from 3.1 x 10-5 mol/L to 8.0 x 10-7 mol/L) and metronidazole (from 3.8 x 10-5 mol/L to 4.0 x 10-7 mol/L).  相似文献   