首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Under suitable conditions, a DNA molecule in solution will develop a strong electric dipole moment. This induced dipole allows the molecule to be manipulated with field gradients, in a phenomenon known as dielectrophoresis (DEP). Pure dielectrophoretic motion of DNA requires alternate current (AC) electric fields to suppress the electrophoretic effect of the molecules net charge. In this paper, we present two methods for measuring the efficiency of DEP for trapping DNA molecules as well as a set of quantitative measurements of the effects of strand length, buffer composition, and frequency of the applied electric field. A simple configuration of electrodes in combination with a microfluidic flow chamber is shown to increase the concentration of DNA in solution by at least 60-fold. These results should prove useful in designing practical microfluidic devices employing this phenomenon either for separation or concentration of DNA.  相似文献   

2.
Microfluidic mixing using contactless dielectrophoresis   总被引:1,自引:0,他引:1  
The first experimental evidence of mixing enhancement in a microfluidic system using contactless dielectrophoresis (cDEP) is presented in this work. Pressure-driven flow of deionized water containing 0.5?μm beads was mixed in various chamber geometries by imposing a dielectrophoresis (DEP) force on the beads. In cDEP the electrodes are not in direct contact with the fluid sample but are instead capacitively coupled to the mixing chamber through thin dielectric barriers, which eliminates many of the problems encountered with standard DEP. Four system designs with rectangular and circular mixing chambers were fabricated in PDMS. Mixing tests were conducted for flow rates from 0.005 to 1?mL/h subject to an alternating current signal range of 0-300?V at 100-600 kHz. When the time scales of the bulk fluid motion and the DEP motion were commensurate, rapid mixing was observed. The rectangular mixing chambers were found to be more efficient than the circular chambers. This approach shows potential for mixing low diffusivity biological samples, which is a very challenging problem in laminar flows at small scales.  相似文献   

3.
Electrically polarizable micro- and nanoparticles and droplets can be trapped using the gradient electric field of electrodes. But the spatial profile of the resultant dielectrophoretic force is fixed once the electrode structure is defined. To change the force profile, entire complex lab-on-a-chip systems must be re-fabricated with modified electrode structures. To overcome this problem, we propose an approach for the dynamic control of the spatial profile of the dielectrophoretic force by interfacing the trap electrodes with a resistor and an inductor to form a resonant resistor–inductor–capacitor (RLC) circuit. Using a dielectrophoretically trapped water droplet suspended in silicone oil, we show that the resonator amplitude, detuning, and linewidth can be continuously varied by changing the supply voltage, supply frequency, and the circuit resistance to obtain the desired trap depth, range, and stiffness. We show that by proper tuning of the resonator, the trap range can be extended without increasing the supply voltage, thus preventing sensitive samples from exposure to high electric fields at the stable trapping position. Such unprecedented dynamic control of dielectrophoretic forces opens avenues for the tunable active manipulation of sensitive biological and biochemical specimen in droplet microfluidic devices used for single-cell and biochemical reaction analysis.  相似文献   

4.
Dielectrophoresis is a technique whereby polarisable particles are manipulated by non-uniform alternating electric fields. A specific application of this technique is deducing the dielectric properties of cells from analysis of the dielectrophoretic spectrum of that particular cell population. We have developed a new microelectrode geometry consisting of two parallel electrode planes, one of which is patterned with arrays of circular apertures or 'dots'. The radial symmetry of the dots means that the polarisability of the particles within the dot can be directly related to change shifts in light transmission through the dot, and quantified from analysis of digital images. We have validated our system using well-characterised cell types and found a high degree of agreement to published data. Furthermore, we have observed that at high particle concentrations, electrostatic inter-particle repulsion causes spontaneous, rapid particle re-dispersion over the dot volume upon removal of an applied electric field. This allows the automated acquisition of a spectrum of 26 data points in approximately 15 min.  相似文献   

5.
Formation of artificial lipid bilayers using droplet dielectrophoresis   总被引:1,自引:0,他引:1  
We describe the formation of artificial bilayer lipid membranes (BLMs) by the controlled, electrical manipulation of aqueous droplets immersed in a lipid-alkane solution. Droplet movement was generated using dielectrophoresis on planar microelectrodes covered in a thin insulator. Droplets, surrounded by lipid monolayers, were brought into contact and spontaneously formed a BLM. The method produced BLMs suitable for single-channel recording of membrane protein activity and the technique can be extended to create programmable BLM arrays and networks.  相似文献   

6.
Aromatic polyamide particles were prepared by reacting p-phthalyl chloride and 4,4′-diaminodiphenyl ether in an acetone solution with a high water content, using a precipitation polymerization method with ultrasonic irradiation. The average particle diameter was ca. 712 nm, and the particles were porous and spherical with a narrow size distribution. They showed a high degree of crystallinity and excellent thermal stability. The morphology and the thermal decomposition temperature of the submicron particles were found to depend strongly on the volume of water added to the reaction system. In this polymerization method, the addition of water was essential for the formation of spherical particles. The simultaneous mixing process resulted in the formation of particles with a narrow size distribution, and the use of ultrasonic irradiation was effective in reducing particle size.  相似文献   

7.
Singh P  Aubry N 《Electrophoresis》2007,28(4):644-657
In microfluidic devices the fluid can be manipulated either as continuous streams or droplets. The latter is particularly attractive as individual droplets can not only move but also split and fuse, thus offering great flexibility for applications such as laboratory-on-a-chip. We consider the transport of liquid drops immersed in a surrounding liquid by means of the dielectrophoretic force generated by electrodes mounted at the bottom of a microdevice. The direct numerical simulation (DNS) approach is used to study the motion of droplets subjected to both hydrodynamic and electrostatic forces. Our technique is based on a finite element scheme using the fundamental equations of motion for both the droplets and surrounding fluid. The interface is tracked by the level set method and the electrostatic forces are computed using the Maxwell stress tensor. The DNS results show that the droplets move, and deform, under the action of nonuniform electric stresses on their surfaces. The deformation increases as the drop moves closer to the electrodes. The extent to which the isolated drops deform depends on the electric Weber number. When the electric Weber number is small, the drops remain spherical; otherwise, the drops stretch. Two droplets, however, that are sufficiently close to each other, can deform and coalesce, even if the electric Weber number is small. This phenomenon does not rely on the magnitude of the electric stresses generated by the bulk electric field, but instead is due to the attractive electrostatic drop-drop interaction overcoming the surface tension force. Experimental results are also presented and found to be in agreement with the DNS results.  相似文献   

8.
This work is the first to demonstrate the ability of contactless dielectrophoresis (cDEP) to isolate target cell species from a heterogeneous sample of live cells. Since all cell types have a unique molecular composition, it is expected that their dielectrophoretic (DEP) properties are also unique. cDEP is a technique developed to improve upon traditional and insulator-based DEP devices by replacing embedded metal electrodes with fluid electrode channels positioned alongside desired trapping locations. Through the placement of the fluid electrode channels and the removal of contact between the electrodes and the sample fluid, cDEP mitigates issues associated with sample/electrode contact. MCF10A, MCF7, and MDA-MB-231 human breast cells were used to represent early, intermediate, and late-staged breast cancer, respectively. Trapping frequency responses of each cell type were distinct, with the largest difference between the cells found at 20 and 30 V. MDA-MB-231 cells were successfully isolated from a population containing MCF10A and MCF7 cells at 30 V and 164 kHz. The ability to selectively concentrate cells is the key to development of biological applications using DEP. The isolation of these cells could provide a workbench for clinicians to detect transformed cells at their earliest stage, screen drug therapies prior to patient treatment, increasing the probability of success, and eliminate unsuccessful treatment options.  相似文献   

9.
Qiao W  Cho G  Lo YH 《Lab on a chip》2011,11(6):1074-1080
We report the first microfluidic device integrated with a printed RF circuit so the device can be wirelessly powered by a commercially available RFID reader. For conventional dielectrophoresis devices, electrical wires are needed to connect the electric components on the microchip to external equipment such as power supplies, amplifiers, function generators, etc. Such a procedure is unfamiliar to most clinicians and pathologists who are used to working with a microscope for examination of samples on microscope slides. The wirelessly powered device reported here eliminates the entire need for wire attachments and external instruments so the operators can use the device in essentially the same manner as they do with microscope slides. The integrated circuit can be fabricated on a flexible plastic substrate at very low cost using a roll-to-roll printing method. Electrical power at 13.56 MHz transmitted by a radio-frequency identification (RFID) reader is inductively coupled to the printed RFIC and converted into 10 V DC (direct current) output, which provides sufficient power to drive a microfluidic device to manipulate biological particles such as beads and proteins via the DC dielectrophoresis (DC-DEP) effect. To our best knowledge, this is the first wirelessly powered microfluidic dielectrophoresis device. Although the work is preliminary, the device concept, the architecture, and the core technology are expected to stimulate many efforts in the future and transform the technology to a wide range of clinical and point-of-care applications.  相似文献   

10.
The emergence of optofluidics has brought a high degree of tuneability and reconfigurability to optical devices. These possibilities are provided by characteristics of fluids including mobility, wide range of index modulation, and abrupt interfaces that can be easily reshaped. In this work, we created a new class of optofluidic waveguides, in which suspended mesoparticles were employed to greatly enhance the flexibility of the system. We demonstrated tuneable quasi single mode waveguides using spatially controllable mesoparticles in optofluidics. The coupling of waveguiding modes into the assembly of mesoparticles produces strong interactions and resonant conditions, which promote the transitions of the waveguiding modes. The modal response of the system depends on the distribution of packed particles above the polymeric rib waveguide which can be readily controlled under the appropriate combination of dielectrophoresis and hydrodynamic forces.  相似文献   

11.
We demonstrate dielectrophoretic (DEP) potential wells using pairs of insulating oil menisci to shape the DC electric field. These oil menisci are arranged in a configuration similar to the quadrupolar electrodes, typically used in DEP, and are shown to produce similar field gradients. While the one-pair well produces a focusing effect on particles in flow, the two-pair well results in creating spatial traps against crossflows. Uncharged polystyrene particles were used to map the DEP force fields and the experimental observations were compared against the field profiles obtained by numerically solving Maxwell's equations. We demonstrate trapping of a single particle due to negative DEP against a pressure-driven crossflow. This can be easily extended to trap and hold cells and other objects against flow for a longer time. We also show the results of particle trapping experiments performed to observe the effect of adjusting the oil menisci and the gap between two pairs of menisci in a four-menisci configuration on the nature of the DEP well formed at the center. A design parameter, Theta, capturing the dimensions of the DEP energy well, is defined and simulations exploring the effects of different geometric features on Theta are presented.  相似文献   

12.
Bacteria play a significant role in both human health and disease. An estimated 9.4 million cases of foodborne illness occur in the United States each year. As a result, rapid identification and characterization of microorganisms remains an important research objective. Despite limitations, selective culturing retains a central role among a cadre of identification strategies. For the past decade, separations-based approaches to rapid bacterial identification have been under investigation. Gradient insulator dielectrophoresis (g-iDEP) promises benefits in the form of rapid and specific separation of very similar bacteria, including serotypes of a single species. Furthermore, this approach allows simultaneous concentration of analyte, facilitating detection and downstream analysis. Differentiation of three serotypes or strains of Escherichia coli bacteria is demonstrated within a single g-iDEP microchannel, based on their characteristic electrokinetic properties. Whole cells were captured and concentrated using a range of applied potentials, which generated average electric fields between 160 and 470 V/cm. Bacteria remained viable after exposure to these fields, as determined by cellular motility. These results indicate the potential g-iDEP holds in terms of both separatory power and the possibility for diagnostic applications.  相似文献   

13.
Cancer is a highly heterogenous disease that requires precise detection tools and active surveillance methods. Liquid biopsy assays provide an agnostic way to follow the complex trajectory of cancer, providing better patient stratification tools for optimized treatment. Here, we present the development of a low-volume liquid biopsy assay called cyc-DEP (cyclic immunofluorescent imaging on dielectrophoretic chip) to profile biomarkers collected on a dielectrophoretic microfluidic chip platform. To enable on-chip cyclic imaging, we optimized a fluorophore quenching method and sequential rounds of on-chip staining with fluorescently conjugated primary antibodies. cyc-DEP allows for the quantification of a multiplex array of proteins using 25 µl of a patient plasma sample. We utilized nanoparticles from a prostate adenocarcinoma (LNCaP) cell line and a panel of six target proteins to develop our proof-of-concept technique. We then used cyc-DEP to quantify blood plasma levels of target proteins from healthy individuals, low-grade and high-grade prostate cancer patients (n = 3 each) in order to demonstrate that our platform is suitable for liquid biopsy analysis in its present form. To ensure accurate quantification of signal intensities and comparisons between different samples, we incorporated a signal intensity normalization method (fluorescent beads) and a custom signal intensity quantification algorithm that account for the distribution of signal across hundreds of collection regions on each chip. Our technique enabled a threefold improvement in multiplicity for detecting proteins associated with fluid samples, opening doors for early detection, and active surveillance through quantification of a multiplex array of biomarkers from low-volume liquid biopsies.  相似文献   

14.
Isomotive dielectrophoresis (isoDEP) is a unique DEP geometrical configuration where the gradient of the field-squared () is constant. IsoDEP analyzes polarizable particles based on their magnitude and direction of translation. Particle translation is a function of the polarizability of both the particles and suspending medium, the particles’ size and shape, and the frequency of the electric field. However, other electrokinetics act on the particles simultaneously, including electrothermal hydrodynamics. Hence, to maximize the DEP force relative to over electrokinetic forces, design parameters such as microchannel geometry, fabrication materials, and applied electric field must be properly tuned. In this work, scaling law analyses were developed to derive design rules, relative to particle diameter, to reduce unwanted electrothermal hydrodynamics relative to DEP-induced particle translation. For a particle suspended in 10 mS/m media, if the channel width and height are below ten particle diameters, the electrothermal-driven flow is reduced by ∼500 times compared to a channel that is 250 particles diameters in width and height. Replacing glass with silicon as the device's underlying substrate for an insulative-based isoDEP reduces the electrothermal induced flow approximately 20 times less.  相似文献   

15.
Dielectrophoresis is an electronic analogue1,2 of optical tweezers3 based on the same physical principle: an ac electric field induces a dipole moment on an object in solution, which then experiences a force proportional to the gradient of the field intensity. For both types of tweezers, this force must compete with thermal Brownian4 motion to be effective, which becomes increasingly difficult as the particle size approaches the nanometer scale. Here we show that this restriction can be overcome by using the large electric field gradient in the vicinity of a carbon nanotube to electronically manipulate nanoparticles down to 2 nm in diameter.  相似文献   

16.
Wirelessly powered dielectrophoresis (DEP) of metal oxide particles was performed using a spark-gap Tesla coil (TC). The main contribution of this work is the simplification of the conventional DEP setup that requires attaching wires directly to the electrodes. Wireless power from the TC generates a high output frequency and voltage, which corresponds to that used for the DEP. Therefore, a spark-gap TC was built and utilized to conduct the DEP process. Metal oxides (ZnO and Fe2O3) were used as targets for the assembly. The results showed that the wirelessly powered DEP technique via a TC was successful in assembling the metal oxide particles. Positive and negative DEP phenomena were observed. Positive DEP occurred during ZnO assembly, making particles chain grow 0.92 mm toward the sparks within 60 s. Negative DEP was observed during Fe2O3 assembly, where the repulsion of particles formed a void around the sparks with a 1.45 mm radius. The mechanism of this wireless DEP system is discussed.  相似文献   

17.
Soap-free emulsion polymerization of styrene using oil-soluble initiators and electrolytes was investigated to synthesize micron-sized polystyrene particles. It was clear that an oil-soluble initiator, such as AIBN, worked like a water-soluble initiator in soap-free emulsion polymerization of styrene to prepare monodispersed particles with negative charges, probably because of the polarization of the electron-attractive functional groups decomposed from the initiators and the pi electron cloud of benzene in a styrene monomer. The addition of an electrolyte enabled secondary particles to effectively promote hetero-coagulation for particle growth by reduction of an electrical double layer and prevention of self-growth. Changing the concentration and type of electrolyte enabled us to control the size up to 12 μm in soap-free emulsion polymerization of styrene using AIBN. Conventionally, organic solvents and surfactants have been used to prepare micron-sized polymeric particles, but this method enabled the synthesis of micron-sized polymeric particles in water using electrolytes without surfactants.  相似文献   

18.
We describe the design, microfabrication, and testing of a microfluidic device for the separation of cancer cells based on dielectrophoresis. Cancer cells, specifically green fluorescent protein‐labeled MDA‐MB‐231, are successfully separated from a heterogeneous mixture of the same and normal blood cells. MDA‐MB‐231 cancer cells are separated with an accuracy that enables precise detection and counting of circulating tumor cells present among normal blood cells. The separation is performed using a set of planar interdigitated transducer electrodes that are deposited on the surface of a glass wafer and slightly protrude into the separation microchannel at one side. The device includes two parts, namely, a glass wafer and polydimethylsiloxane element. The device is fabricated using standard microfabrication techniques. All experiments are conducted with low conductivity sucrose‐dextrose isotonic medium. The variation in response between MDA‐MB‐231 cancer cells and normal cells to a certain band of alternating‐current frequencies is used for continuous separation of cells. The fabrication of the microfluidic device, preparation of cells and medium, and flow conditions are detailed. The proposed microdevice can be used to detect and separate malignant cells from heterogeneous mixture of cells for the purpose of early screening for cancer.  相似文献   

19.
We theoretically investigate the separation of individualized metallic and semiconducting single-wall carbon nanotubes (SWNTs) in a dielectrophoretic (DEP) flow device. The SWNT motion is simulated by a Brownian dynamics (BD) algorithm, which includes the translational and rotational effects of hydrodynamic, Brownian, dielectrophoretic, and electrophoretic forces. The device geometry is chosen to be a coaxial cylinder because it yields effective flow throughput, the DEP and flow fields are orthogonal to each other, and all the fields can be described analytically everywhere. We construct a flow-DEP phase map showing different regimes, depending on the relative magnitudes of the forces in play. The BD code is combined with an optimization algorithm that searches for the conditions that maximize the separation performance. The optimization results show that a 99% sorting performance can be achieved with typical SWNT parameters by operating in a region of the phase map where the metallic SWNTs completely orient with the field, whereas the semiconducting SWNTs partially flow-align.  相似文献   

20.
Tsai SL  Hong JL  Chen MK  Jang LS 《Electrophoresis》2011,32(11):1337-1347
This work presents a microfluidic system that can transport, concentrate, and capture particles in a controllable droplet. Dielectrophoresis (DEP), a phenomenon in which a force is exerted on a dielectric particle when it is subjected to a non-uniform electric field, is used to manipulate particles. Liquid dielectrophoresis (LDEP), a phenomenon in which a liquid moves toward regions of high electric field strength under a non-uniform electric field, is used to manipulate the fluid. In this study, a mechanism of droplet creation presented in a previous work that uses DEP and LDEP is improved. A driving electrode with a DEP gap is used to prevent beads from getting stuck at the interface between air and liquid, which is actuated with an AC signal of 200 V(pp) at a frequency of 100 kHz. DEP theory is used to calculate the DEP force in the liquid, and LDEP theory is used to analyze the influence of the DEP gap. The increment of the actuation voltage due to the electrode with a DEP gap is calculated. A set of microwell electrodes is used to capture a bead using DEP force, which is actuated with an AC signal of 20 V(pp) at a frequency of 5 MHz. A simulation is carried out to investigate the dimensions of the DEP gap and microwell electrodes. Experiments are performed to demonstrate the creation of a 100-nL droplet and the capture of individual 10-μm polystyrene latex beads in the droplet.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏