首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive method has been developed for the detection and quantitative determination of thiodiglycol in blood, plasma and urine. Samples were extracted from Clin Elut columns and cleaned up on C18 Sep-Pak cartridges (blood, plasma) or Florisil Sep-Pak cartridges (urine). Tetradeuterothiodiglycol was added to the sample prior to extraction as internal standard. Thiodiglycol was converted to its bis-(pentafluorobenzoate) derivative and analysed by capillary gas chromatography-electron-capture negative-ion chemical ionisation mass spectrometry using selected ion monitoring. Levels of thiodiglycol down to 1 ng/ml (1 ppb) could be detected in 1-ml spiked blood and urine samples; calibration curves were linear over the range 5- or 10-100 ng/ml. Blood and urine samples from a number of control subjects were analysed for background levels of thiodiglycol. Concentrations up to 16 ng/ml were found in blood, but urine levels were below 1 ng/ml.  相似文献   

2.
A sensitive and specific capillary gas chromatographic method has been developed to measure trace amounts of 2,2'-dichlorodiethyl sulphide (sulphur mustard) in environmental or biological samples. Sulphur mustard was isolated from water or plasma by a solid-phase extraction procedure and from blood by liquid-liquid extraction. The accuracy and precision of the methods were demonstrated using replicate analyses of spiked water, plasma or blood: within-run and between-run variabilities were less than 20%. These analytical methods were used to evaluate the rate of sulphur mustard degradation in water or plasma. Good linear calibration curves, with a detection limit of 45 ng/ml, were obtained for quantitation and determination of sulphur mustard in blood following its intravenous administration to rats. Initial toxicokinetic data were obtained.  相似文献   

3.
A method for determining thiodiglycol (TDG), a mustard gas hydrolysis product in water, serum and urine samples using gas chromatography-mass spectrometry (GC-MS) after tert-butyldimethylsilylation (TBDMS) is described. Quantitation of TDG was performed by measuring the respective peak area on the extracted ion chromatogram of m/z 293, using an internal standard, the TDG homologue, thiodipropanol, peak area of which was measured as m/z 321. The presence of salts in the sample solution not only suppressed the loss of TDG by vaporization during the evaporation of water, but also facilitated the rate of production of di-silylated derivative, bis(tert-butyldimethylsilyoxylethyl)sulfide (TDG-(TBDMS)2). Under the pretreatment conditions used, in which 0.5 ml of water sample supplemented with 100 microM potassium chloride was evaporated to dryness under reduced pressure, followed by reaction with N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide at 60 degrees C for 1 h, TDG-(TBDMS)2 was reproducibly detected with about a 55% recovery and a limit of detection (LOD, scan mode, S/N = 3) of 5.4 ng/ml. TDG was also determined by GC-MS from a 0.5 ml serum sample (after perchloric acid deproteinization) and from a 0.1 ml urine sample, after TBDMS derivatization. The LOD was determined to be 7.0 and 110 ng/ml for serum and urine, respectively.  相似文献   

4.
Applied Biochemistry and Biotechnology - An environmentally benign method for the mineralization of sulfur mustard has been proposed involving chemical hydrolysis of sulfur mustard to thiodiglycol,...  相似文献   

5.
该研究基于暴露生物标记物溯源思路,应用于解决芥子气(SM)临床早期诊断、溯源确证难题。建立了芥子气中毒患者尿液中7种游离代谢产物的两步固相萃取/超高效液相色谱-串联质谱(SPE/UPLC-MS/MS)同时定量方法,检出限为5 pg/mL~1 ng/mL,定量下限为10pg/mL~5 ng/mL;结合前期建立的4种游离碱基加合物的同位素稀释-UPLC-MS/MS定量方法,对1例疑似芥子气中毒人员尿液中可能赋存的生物标记物进行了全筛查分析。尿液中共检出3类10种生物标记物,包括首次报道的游离代谢产物芥子亚砜,可确证患者为芥子气中毒;除硫二甘醇外,标记物含量均在暴露后3~4 d达到峰值,随后降低,至7 d仍可检出,其中谷胱甘肽加合物的β裂解产物含量相对较高,可作为芥子气中毒早期诊断与疗效评估的重要指标。  相似文献   

6.
Abstract

A simple, selective and sensitive HPLC method has been developed to measure R-831 levels in dogs and humans. It is an internal standard technique with a single step extraction and one wash. Samples are chromatographed on a reversed-phase system with ultraviolet detection. The lowest detectable concentration for plasma is 25 ng R-831/ml with a 1 ml sample and the linear range is 25–8000 ng R-831/ml. The lowest detectable concentration for urine is 250 ng R-831/ml with a 0.1 ml sample and the linear range is 250–8000 ng R-831/ml. This method has been used to quantitate levels of R-831 in bioavailability and toxicity studies in dogs, and in pharmacokinetic and efficacy studies in humans.  相似文献   

7.
A highly sensitive method for the determination of sulfur mustard (SM) metabolites thiodiglycol (TDG) and thiodiglycol sulfoxide (TDGO) in urine was established and validated using isotope-dilution negative-ion chemical ionization (NICI) gas chromatography–mass spectrometry (GC–MS). TDGO in the samples was reduced with TiCl3, and then determined together with TDG as a single analyte. The sample preparation procedures, including two solid-phase-extraction (SPE) clean-up steps, were optimized to improve the sensitivity of the method. The limits of detection (LOD) for both TDG and TDG plus TDGO (TDG + TDGO) were 0.1 ng mL?1, and the limits of quantitation (LOQ) for both were 0.3 ng mL?1. The method was used in a rabbit cutaneous SM exposure model. Domestic rabbits were exposed to neat liquid SM at three dosage levels (0.02, 0.05, and 0.15 LD50), and the urinary excretion of four species of hydrolysis metabolites, namely free TDG, free plus conjugated TDG (total TDG), free TDG + TDGO, and free plus conjugated TDG + TDGO (total TDG + TDGO), was evaluated to investigate the metabolic processes. The total urinary excretion profiles of the metabolites, including the peak time, time window, and dose–response and time–response relationships, were clarified. The results revealed that the concentrations of TDG and TDG + TDGO in the urine increased quickly and then decreased rapidly in the first two days after SM exposure. The cumulative amount of total TDG + TDGO excreted in urine during the first five days accounted for 0.5–1 % of the applied dose of SM. It is also concluded that TDG and TDGO in urine existed mainly in free form, the levels of glucuronide and of sulfate conjugates of TDG or TDGO were very low, and most hydrolysis metabolites were present in the oxidized form (TDGO). The study indicates that the abnormal increase of TDG and TDGO excretion levels can be used as a diagnostic indicator and establishes a reference time-window for retrospective analysis and sampling after SM exposure.  相似文献   

8.
An improved radioreceptor assay (RRA) is used for the screening of urine samples from cattle for the presence of exogenous oestrogenic anabolic compounds, e.g., stilbenes and zeranol. The method includes extraction of the hormones from urine samples with simultaneous purification using reversed-phase C18 cartridges. High-performance liquid chromatography is used to isolate the anabolics from the naturally occurring oestrogens. Fractions containing the stilbenes and zeranol are collected and subsequently analysed using the RRA with the oestrogen receptor, isolated from immature calf uteri, as a binder and tritiated 17 beta-oestradiol as a tracer. Urine samples from untreated calves and cows and samples from calves treated with zeranol-trenbolon acetate, dienoestrol or hexoestrol or samples containing diethylstilboestrol were analysed with this RRA method. Sensitivity, specificity and predictive values were calculated at different classification levels (0.4, 0.5, 0.6 and 1.0 ng/ml 'apparent' oestradiol in urine). An optimum sensitivity (89%) with a maximum specificity (95%) was reached at a classification level of 0.6 ng/ml. At this level the detection limits in urine samples are 0.5 ng/ml for hexoestrol, 0.6 ng/ml for diethylstilboestrol, 0.9 ng/ml for dienoestrol and 5.0 ng/ml for zeranol.  相似文献   

9.
A selective, direct and relatively rapid method has been developed for the determination of thiodiglycol (TDG) in aqueous samples. TDG is the main hydrolysis product of the chemical warfare agent sulfur mustard. The method of analysis is based on the on-line coupling of reversed-phase microcolumn liquid chromatography and sulfur-selective flame photometric detection. To improve sensitivity and efficiency, peak compression by displacement was used in combination with large-volume injections. A concentration of 1% n-propanol was added to the sample to obtain the best sensitivity and efficiency after a 10 microliters injection. Detection limits of 0.25 microgram/ml were achieved with efficiencies of 4.10(5) plates per meter. The method was successfully applied during the Fourth Official Proficiency Test organized by the Technical Secretariat of the Organization for Prohibition of Chemical Weapons for the determination of TDG in a soil sample.  相似文献   

10.
A method for trace determination of sulphur mustard (HD) and some of its cyclic decomposition compounds in water samples has been developed using headspace-trap in combination with gas chromatography–mass spectrometry (GC–MS). Factorial design was used for optimisation of the method. The trap technology allows enrichment and focusing of the analytes on an adsorbent, hence the technique offers better sensitivity compared to conventional static headspace. A detection limit of 1 ng/ml was achieved for HD, while the cyclic sulphur compounds 1,4-thioxane, 1,3-dithiolane and 1,4-dithiane could be detected at a level of 0.1 ng/ml. The method was validated for the stable cyclic compounds in the concentration range from the limit of quantification (LOQ: 0.2–0.4 ng/ml) to hundred times LOQ. The within and between assay precisions at hundred times LOQ were 1–2% and 7–8% relative standard deviation, respectively. This technique requires almost no sample handling, and the total time for sampling and analysis was less than 1 h. The method was successfully employed for muddy river water and sea water samples.  相似文献   

11.
A solid-phase microextraction (SPME) method has been developed to determine two methylated arsenic species in human urine samples by GC-MS. The direct extraction of the methyl arsenic compounds by SPME after thioglycol methylate derivatization was studied. Direct extraction with SPME was suitable for the determination of trace levels of dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) in urine samples. Four different commercial SPME fibers were tested for the extraction of methyl arsenic compounds, and the best results were obtained using the polydimethylsiloxane coating. The extraction and desorption time profiles of DMA and MMA were determined. The detection limits for DMA and MMA using the SPME-GC-MS method were 0.12 and 0.29 ng/ml, respectively. The method is linear in the 1 to 200 ng/ml range.  相似文献   

12.
In an effort to characterize the pharmacokinetic behavior of the antimitotic agent N-desacetylcolchicine a selective, sensitive high-performance liquid chromatographic method was developed for the determination of N-desacetylcolchicine, demecolcine and colchicine in serum or urine. To 0.5 ml of serum or 0.1 ml of urine diluted to 0.5 ml were added 50 microliters demecolcine (2 micrograms/ml) which serves as the internal standard. The sample was extracted using a C2 reversed-phase solid extraction column. N-Desacetyl-colchicine, colchicine and the internal standard were eluted from the column with methanol. The combined eluates were evaporated to dryness and the residue was reconstituted with water. The reconstituted sample was injected into a C18 reversed-phase column and eluted using a mobile phase consisting of 0.1 M potassium dihydrogenphosphate, 5 mM 1-pentanesulfonic acid in methanol and acetonitrile with a final pH of 6.0, at a flow rate of 1.5 ml/min. N-Desacetylcolchicine, colchicine and the internal standard were detected using a variable-wavelength ultraviolet detector at 254 nm. The limit of detection was 0.4 ng/ml for desacetylcolchicine and 4.0 ng/ml for colchicine. The method is linear over a concentration range of 1.0-200 ng/ml. The method has been shown to be a rapid, reliable method to monitor N-desacetylcolchicine levels in clinical trials in cancer patients.  相似文献   

13.
A new simple and sensitive assay has been developed for the simultaneous quantitative measurement of beclomethasone dipropionate and its hydrolysis products in human plasma and urine. Beclomethasone 17.21-dipropionate, beclomethasone 17-monopropionate, beclomethasone and the internal standard, dexamethasone 21-acetate, were measured by combined liquid chromatography and negative-ion chemical ionization mass spectrometry with methane as the reagent gas. A particle beam interface from Hewlett Packard was used. Under mild operating conditions, abundant and stable characteristic high-mass ions were generated in the ion source of the mass spectrometer by a resonance electron-capture mechanism. The fast extraction procedure requires 1 ml of plasma or urine, and the quantification limit of the method is 1 ng ml-1 for the three tested compounds.  相似文献   

14.
《Analytical letters》2012,45(12):941-949
Abstract

An HPLC method for analysis of atenolol in human plasma and urine is presented. Based on alkaline extraction, acid backextraction and reverse phase ion-pair chromatography this method is quite specific for atenolol. For a 0.5 ml plasma sample the sensitivity ranges from 20 ng/ml in fasted healthy volunteers to 50 ng/ml in various groups of patients. A sensitivity in urine of 1.0 mcg/ml was sufficient for all samples studied. As presented this method has been used in several clinical pharmacokinetic studies involving hundreds of samples.  相似文献   

15.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

16.
A sensitive and selective high-performance liquid chromatographic method has been developed for a new sulphonylurea, glimepiride, and its metabolites. The assay involves extraction with diethyl ether, thermolysis of the sulphonylureas at 100 degrees C and trapping of the resulting amines with 2,4-dinitrofluorobenzene. The derivatives were quantitated on a reversed-phase column by absorbance at 350 nm using a step gradient for the three compounds in serum and an isocratic run for the metabolites in urine. Analogous compounds were used as internal standards. The detection limit was 5 ng/ml for glimepiride and metabolite II and 10 ng/ml for metabolite I using 1 ml of serum. The method has been applied to the analysis of serum and urine samples from pharmacokinetic studies in humans.  相似文献   

17.
A sensitive and specific bioanalytical method for quantitation of a novel antiemetic (ADR-851) in plasma and urine has been developed and validated. The drug and internal standard (metoclopramide) are extracted from the plasma matrix by solid-phase extraction on cyanopropyl bonded-phase columns. After extraction, samples are separated by isocratic reversed-phase high-performance liquid chromatography. The parent drug, internal standard and a yet unidentified metabolite are detected by fluorescence. The method requires 1.0 ml of plasma or 0.1 ml of urine and has a lower limit of quantitation of 2 ng/ml with 10.9% relative standard deviation (R.S.D.). Method linearity has been established over a 2-800 ng/ml range when 1.0 ml of plasma is used. The intra- and inter-day imprecisions for the method are typically better than 6% and 11% R.S.D., respectively, in both plasma and urine over the entire dynamic range. The pooled estimate of bias is less than 5% and attests to the excellent accuracy.  相似文献   

18.
水中芥子气水解产物硫二甘醇的分析   总被引:1,自引:0,他引:1  
建立了水中芥子气水解产物硫二甘醇HLB-H104固相萃取法,应用GC-GC-MS分析鉴定,该法操作简便,灵敏度高,方法回收率可达74%,检出限为0.002mg/L。  相似文献   

19.
Dynamic liquid-phase microextraction (dLPME) using an ionic liquid as acceptor phase is proposed for the determination of six non-steroidal anti-inflammatory drugs (NSAIDs) in human urine samples for the first time. The extraction is carried out in a simple and automatic flow configuration. The chemical affinity between the extractant (1-butyl-3-methylimidazolium hexafluorophosphate) and the analytes permits a selective isolation of the drugs from the sample matrix allowing also their preconcentration. The whole analytical method has been optimized taking into account all the chemical, physical and hydrodynamic variables. The proposed method is a valuable alternative for the analysis of these drugs in urine within the concentration range 0.1-10 microg mL(-1), allowing their determination at therapeutic and toxic levels. Limits of detection were in the range from 38 ng mL(-1) (indomethacin) to 70 ng mL(-1) (naproxen). The repeatability of the proposed method expressed as RSD (n=5) varied between 2.1% (flurbiprofen) and 3.8% (tolmetin).  相似文献   

20.
A simple, sensitive method for the determination of the prifinium ion, a quaternary ammonium ion, in human serum and urine is described. The method is based on extraction of the test solution with chloroform in the presence of saturated potassium bromide solution and normal-phase high-performance liquid chromatography using aqueous methanol as the mobile phase at pH 10. To prevent the dissolution of silica from the analytical column, the mobile phase is pre-saturated with silica by using a silica saturation column. Quantitation is possible down to 0.5 ng/ml of prifinium ion using 2 ml of serum and down to 5 ng/ml using a 1 ml of urine. The coefficients of variation of the method are less than 1.3% in both serum and urine. Serum levels and urinary excretion data obtained with this method are given for three healthy volunteers who had received a 60-mg oral dose of prifinium bromide.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号