共查询到20条相似文献,搜索用时 15 毫秒
1.
A solid ion-pair material produced from ammonium tetraphenylborate on naphthalene (ATPB-naphthalene) provides a simple, rapid, economical and selective technique for preconcentrating iron from approximately 500 ml of aqueous solution of standard alloys and biological samples. Iron reacts with 2-(5-bromo-2-pryidlazo)-5-diethylaminophenol (5-Br-PADAP) to form a water-soluble cationic complex. When the aqueous solution of this cationic species in the pH range 3.2-8.5 is passed over the adsorbent ATPB-naphthalene at a flow rate of 1 ml min(-1), it is quantitatively retained on naphthalene as an uncharged ion-associated complex. The solid mass from the column was dissolved out with 5 ml of dimethylformamide (DMF) and iron is determined by third derivative spectrophotometry by measuring the signal d(3)A/ dlambda(3) between lambda(2)(773 nm) and lambda(3)(737 nm). The calibration curve is linear over the concentration range 0.10-25.0 mug of iron in 5 ml of DMF solution. Eight replicate determinations of 5 mug of iron gave a mean intensity (peak-to-peak signal between lambda(2) and lambda(3)) of 1.534 with a relative standard deviation of 0.90%. The sensitivity of the method is 0.307 (d(3)A/dnm(3) )/mug found from the slope of the calibration curve. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of iron in various standard alloys and biological samples. 相似文献
2.
A simple, sensitive and rapid derivative spectrophotometric method using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) has been developed for simultaneous determination of Co(II), Ni(II) and Fe(II) which have very similar chemical behavior and appear together in many real samples. The complexes of all these metal ions with 5-Br-PADAP were formed immediately at pH 7.0 ammonium acetate buffered solution and were stable for at least 24 h. Second derivative spectra were selected for evaluation, because working wavelength determination was more precise and spectral overlap was less than in the ordinary and first derivative spectra. Three wavelengths at which the complexes exhibit extremum 2D values for Co(II), Ni(II) and Fe(II) were selected as analytical wavelengths, i.e., 640, 600 and 740 nm, respectively. Calibration curves drawn with zero-to-peak values at mentioned wavelengths were linear between 80 and 2000 ng ml−1 for each metal ion. Concentrations of Co(II) and Ni(II) were calculated from the total 2D values and the sum of the linear equations for these three cations at 640 and 600 nm, after Fe(II) assay by making use of the 2D value at 740 nm. Limits of detection (LOD) for Co(II), Ni(II) and Fe(II) were 2.7, 13.9 and 3.0 ng ml−1, respectively. The method has been applied to tool steel and heater resistance wire samples successfully. 相似文献
3.
IntroductionVanadiumisoneofthemostimportantelementwhichaffectsthephysicalpropertiesofsteel,alloysandhighpuritymetals .Itiswidelydistributedintheearth’scrust,anditscompoundscanbehighlytoxictomanandanimalsandcauseenvironmentaldiseaseswhenreleasedintheatm… 相似文献
4.
M. A. Taher 《Analytical and bioanalytical chemistry》2000,368(4):421-423
Chromium can be quantitatively retained as 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-tetraphenylborate(TPB) complex onto microcrystalline naphthalene in the pH range 4.8–5.9 from a large volume of aqueous solutions of various standard samples. After filtration, the solid mass consisting of the chromium complex and naphthalene was dissolved with 5 mL of dimethylformamide and the metal was determined by air-acetylene FAAS. A detection limit of ¶4 ng/mL for chromium was established. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of chromium in various standard alloys and biological samples. 相似文献
5.
Taher MA 《Fresenius' Journal of Analytical Chemistry》2000,368(4):421-423
Chromium can be quantitatively retained as 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-tetra-phenylborate(TPB) complex onto microcrystalline naphthalene in the pH range 4.8-5.9 from a large volume of aqueous solutions of various standard samples. After filtration, the solid mass consisting of the chromium complex and naphthalene was dissolved with 5 mL of dimethylformamide and the metal was determined by air-acetylene FAAS. A detection limit of 4 ng/mL for chromium was established. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of chromium in various standard alloys and biological samples. 相似文献
6.
A new sensitive and highly selective method is described for the spectrophotometric determination of microgram amounts of vanadium(V). First, vanadium is isolated by extraction withN-benzoyl-N-phenylhydroxylamine (BPHA) in chloroform from about 4M hydrochloric acid medium. Then, chloroform is evaporated and the residue mineralized with mixture of cone. perchloric and nitric acid. Finally, a colour reaction of vanadium(V) separated with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) in an acetate buffer (pH 4.5) gives a molar absorptivity of 5.48×104l·mol–1·cm–1 at 585 nm. The proposed method was applied for the determination of traces of vanadium in aluminium samples. The results obtained show a good precision and accuracy of the method. 相似文献
7.
A highly selective and sensitive anodic stripping differential pulse polarographic method has been developed for the determination of trace amount of bismuth in various samples after adsorption of its 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex on amberlite XAD-2 resin in the pH range of 2.0-3.0. The retained analyte on the resin recovered with 10.0 ml of 2 M hydrochloric acid and bismuth is determined by anodic stripping differential pulse polarography. In this case, 0.15 μg of bismuth can be concentrated in the column from 1100 ml of aqueous sample, where its concentration is as low as 0.14 ng ml−1 and the linearity is maintained in the concentration range 0.05-160 μg ml−1 in final solution with a correlation coefficient of 0.999 and relative standard deviation of ±1.2%. Various parameters such as the effect of pH, flow rate, and interference of number of metal ions on the determination of bismuth have been studied in detail to optimize the conditions for determination of bismuth in standard alloys: Nippon Keikinzoku Kogyo (NKK CRM No. 916 aluminum alloy); (NKK CRM No. 1021 Al, Si, Cu, Zn alloy); and (NKK CRM No. 920 aluminum alloy), biological samples: National Institute for Environmental Studies (NIES, No. 5 human hair; NIES, No. 7 tea leaves) and water samples: (spring water, river water; Kerman water; and Shiraz water). 相似文献
8.
9.
10.
The direct determination of uranium(VI) by a flow-injection procedure is based on spectrophotometric measurement with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol in the present of fluoride. The interfering effects of many commonly occuring elements were studied. The calibration curve was linear over the range 0.5–20 mg 1?1 uranium(VI). The relative standard deviation obtained on a leach liquor containing 10 mg 1?1 uranium(VI) was 1.9%. The procedure is rapid and convenient, and up to 40 samples can be analysed per hour. 相似文献
11.
Narinder K Agnihotri Sonia Ratnani Vinay K Singh Har B Singh 《Analytical sciences》2003,19(9):1297-1301
A new derivative spectrophotometric method for rapid and selective trace analysis of Ga3+ and In3+ and for their simultaneous determination using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol in a cationic micellar medium is reported. Molar absorptivity and Sandell's sensitivity of 1:1 Ga+ and In3+ complexes at their lambda(max) 553 nm and 558 nm are: 7.22 x 10(4) l mol(-1) cm(-1) and 5.85 x 10(4) l mol(-1) cm(-1), and 0.96 ng cm(-2) and 1.96 ng cm(-2), respectively. Linearity is observed in the concentration range 0.023-0.700 microg ml(-1) for gallium and 0.076-1.52 microg ml(-1) for indium; IUPAC detection limit is 0.012 and 0.035 ng ml(-1), respectively. These metal ions interfere with the determination of each other. However, 0.07-0.70 microg ml(-1) Ga3+ and 0.115-1.150 microg ml(-1) In3+ could be determined simultaneously when present together by the derivative method without any prior separation. The proposed procedures have been successfully applied for the individual and simultaneous determination of gallium and indium in synthetic binary mixtures, standard reference materials and environmental samples. 相似文献
12.
Enass M. Ghoneim 《Talanta》2010,82(2):646-652
A simple and precise square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV) method has been described for simultaneous determination of Mn(II), Cu(II) and Fe(III) in water samples using a carbon paste electrode. In 0.1 mol L−1 acetate buffer (pH 5) containing 50 μmol L−1 of 2-(5′-bromo-2′-pyridylazo)-5-diethylaminophenol (5-Br-PADAP), Mn(II), Cu(II) and Fe(III) were simultaneously determined as metal-complexes with 5-Br-PADAP following preconcentration onto the carbon paste electrode by adsorptive accumulation at +1.0 V (vs. Ag/AgCl/3 M KCl). Insignificant interference from various cations (K+, Na+, Mg2+, Ca2+, Al3+, Bi3+, Sb3+, Se4+, Zn2+, Ni2+, Co2+, Cd2+, Pb2+, V5+, Ti4+ and NH4+), anions (HCO3−, Cl−, NO3−, SO42− and PO43−) and ascorbic acid was noticed. Limits of detection of 0.066, 0.108 and 0.093 μg L−1 and limits of quantitation of 0.22, 0.36 and 0.31 μg L−1 Mn(II), Cu(II) and Fe(III), respectively, were achieved by the described method. The described stripping voltammetry method was successfully applied for simultaneous determination of Mn(II), Cu(II) and Fe(III) in ground, tap and bottled natural water samples. 相似文献
13.
A simple method for the determination of uranium in process- and waste-stream samples at a nuclear fuel reprocessing facility that can be applied entirely in a remote environment is described. The method is both sensitive and selective enough to be applicable for almost any uranium determination. Uranium in aqueous samples is extracted as a nitrate complex into 4-methylpentan-2-one (hexone) from an acid-deficient aluminium nitrate salting solution. An aliquot of the hexone extract is then mixed with a solution containing methanol, pyridine and 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Br-PADAP). The absorbance of the U(VI)-Br- PADAP complex is measured at 580 nm. The detection limit for uranium is 0.8 μg with the linear range extending to 80 μg. Interference studies, modifications for organic samples and solid-containing samples and process laboratory data are presented. 相似文献
14.
Spectrophotometric studies on a uranium(VI) ternary complex and its analytical application are described. Uranium(VI) reacts with 5-Br-PADAP to form an unstable chelate, which precipitates on standing in 48% ethanolic aqueous solution. The colour stability of uranium(VI) complex is greatly improved by the presence of aromatic carboxylic acids. For the present purpose, o-hydroxybenzoic acid and its derivatives are best suited. The calibration graph is linear up to 2.6 g·ml–1 of uranium(VI) at 578 nm. The role of carboxylic acid as an auxiliary ligand is discussed. 相似文献
15.
应用2-(5-硝基-2-吡啶偶氮)-5-二甲氨基苯胺同时测定铑与钯 总被引:3,自引:0,他引:3
提出了以 2 - ( 5-硝基 - 2 -吡啶偶氮 ) - 5-二甲氨基苯胺 ( 5- NO2 - PADMA)作为铑、钯同时测定的新光度试剂。钯与试剂可在 0 .3~ 3.9mol/L 的高氨酸介质中形成稳定的配合物 ,其最大吸收位于 62 1 nm处 ;而铑与试剂则在 p H=5.2 5~ 6.75的近中性介质中定量配合 ,配合物一旦形成则很稳定 ,向其中加入强酸酸化该配合物不仅不被分解反而吸收红移、吸光度增大 ,同时二者的吸光度具有良好的加和性。基于二者显色酸度的差异 ,建立了铑、钯同时测定的新方法。方法的灵敏度为 εRh62 0 =1 .39× 1 0 5L·mol-1·cm-1;εPd62 0 =9.4× 1 0 4 L· mol-1·cm-1。铑浓度在 0~ 0 .56、钯浓度在 0~ 1 .4μg·m L-1范围内服从比耳定律。可用于工业样品中微量铑、钯的测定。 相似文献
16.
A solid co-precipitated material obtained from an ion-pair of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) and tetraphenylborate (TPB), and microcrystals of naphthalene has been tried as an adsorbent for the column preconcentration of copper(I), iron(II), nickel(II) and Zn(II). The retention of the metal ions was found to be maximum and constant in the pH range 3.0-8.0 for Cu, 3.8-7.5 for Fe, 4.5-7.5 for Ni and 8.5-11.0 for Zn. The elements were determined by FAAS after dissolving the metal along with the adsorbent in an organic solvent (10 mL of DMF). The characteristic concentration for 1% absorption was found to be 0.0332, 0.0536, 0.0537 and 0.0142 (aqueous medium 0.0512, 0.0638, 0.1294 and 0.0216) microg mL(-1) for Cu, Fe, Ni and Zn, respectively. The calibration plot was linear in the range 1.5-20.0, 2.0-38.0, 2.5-25.0 and 0.5-15.0 micro g in the final 10 mL of DMF solution for Cu, Fe, Ni and Zn, respectively. Various parameters such as pH, volume of buffer, amount of adsorbent, flow rate, preconcentration factor and effect of diverse salts and cations were studied. The optimised conditions were utilized for the determination of Cu, Fe, Ni and Zn in various water, beverage and human hair samples. 相似文献
17.
Silaned glass beads are applied for the preconcentration and spectrophotometric determination of cobalt with 2-(2-pyridylazo)-5-diethylaminophenol (PADAP). Traces of cobalt are collected as the coloured PADAP complex on a column of the beads, and the complex is then eluted with a small volume of ethanol-hydrochloric acid mixture and the absorbance of the eluate is measured at 575 nm. The cobalt can easily be concentrated by a factor of 50-500 in this way, and 0.1-2 mug of cobalt in 100 ml of sample solution can be determined reproducibly. High concentrations of Fe(III), Cr(III), Pb, Zn, Cu(II), Mn(II), Cd, Al, Ca and Mg can be tolerated but Pd(II) interferes. 相似文献
18.
在pH 1.8~3.0的Britton-Robinson (BR)缓冲溶液中, 钴(II)与2-(5-溴-2-吡啶偶氮)-5-二乙氨基酚(5-Br-PADAP)(HL)反应形成紫红色螯合阳离子, 此时仅能引起吸收光谱的变化, 不能导致共振瑞利散射(RRS)的增强. 当钴(II)-5-Br-PADAP螯合阳离子与阴离子表面活性剂十二烷基苯磺酸钠(SDBS)、十二烷基磺酸钠(SLS)和十二烷基硫酸钠(SDS)作用时, 仅能与SDBS进一步反应形成三元离子缔合物并引起RRS的显著增强, 而不与SDS和SLS产生类似反应. 离子缔合物的RRS峰分别位于306, 370和650 nm处, 在一定范围内RRS增强(ΔI)与SDBS浓度成正比, 当用650 nm处测量时, 其检出限为0.043 μg8226;mL-1, 线性范围为0.14~6.0 μg8226;mL-1. 文中研究了反应产物的RRS光谱特征, 适宜的反应条件及分析化学性质, 据此发展了一种在一定量SDS和SLS等阴离子表面活性剂存在下选择性测定SDBS的新方法, 方法灵敏、简便、快速,用于天然水和污水中SDBS的测定, 获得满意结果. 文中还对反应机理进行了讨论. 相似文献
19.
Nickel is a moderately toxic element compared with other transition metals. However, inhalation of nickel and its compounds leads to serious problems, including cancer of the respiratory system and a skin disorder, nickel-eczema. Thus, attention has focused on the toxicity of nickel at low concentrations, and the development of reliable, analytical approaches for the determination of trace amounts of nickel is needed. This paper describes a simple, rapid, and sensitive flame atomic absorption spectrometric method for the determination of trace amounts of nickel in various samples after adsorption of its 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex on a modified Analcime column in the pH range of 7.5-10.5. The retained analyte on the Analcime is recovered with 5.0 mL 2 M nitric acid and determined by flame atomic absorption spectrometry. The detection limit is 20 ng/mL, and the calibration curve is linear for analyte concentrations in the range of 0.1-8 microg/mL final solution, with a correlation coefficient of 0.9993. Eight replicate determinations of nickel at 2 microg/mL in the final solution gave an absorbance of 0.1222, with a relative standard deviation (RSD) of +/-1.2%. The interference of a large number of anions and cations was studied, and the proposed method was used for the determination of nickel in various standard reference samples. The accuracy of the proposed method was evaluated by analyzing standard reference samples, and the results were satisfactory (recoveries of >96%; RSD of <3.5%). 相似文献
20.
Cobalt-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-tetraphenylborate ion associated complex is quantitatively adsorbed on microcrystalline naphthalene in the pH range 3.5-9.5 from a fairly large volume of the aqueous samples (preconcentration factor ~30). After filtration, the solid mass consisting of the cobalt complex and naphthalene was dissolved with 5 ml of dimethylformamide (DMF) and the metal determined by first-derivative spectrophotometry. The cobalt-5-Br-PADAP complex can alternatively be quantitatively retained on ammonium tetraphenylborate-naphthalene adsorbent filled in a column (preconcentration factor 120) in the same pH range and determined similarly. The detection limit is 30 ppb (signal-to-noise ratio=2) and the calibration curve is linear over 0.3-8.0 mug of cobalt in 5 ml of the final DMF solution. Eight replicate determinations of 1.0 mug of cobalt gave a mean peak height of 0.208 (at 611.5 nm) with a relative standard deviation of 1.2%. The sensitivity of the method is 1.04 (dA/dnm) ml mug(-1) found from the slope of the calibration curve. The interference of a large number of anions and cations on the determination of cobalt has been studied and the optimized conditions developed were utilized for its trace determination in various standard alloys and biological samples. 相似文献