首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Four As compounds were successfully separated and detected by single-column ion chromatography with inductively coupled plasma (ICP) mass spectrometric detection. The mass spectral interferent ArCl+ was reduced by chromatographically resolving chloride from the negatively charged arsenic species. Determination of four As species was investigated in urine, club soda and wine. Detection limits of 0.16 ng of As(III), 0.26 ng of As(v), 0.073 ng of dimethylarsinic acid (DMA) and 0.18 ng of methylarsonic acid (MMA) in wine were obtained. Sensitivity was further improved by using an He-Ar mixed gas ICP as the ionization source. However, the intensity of the ArCl+ interference was also increased using this plasma. Detection limits of 0.063 ng of As(III), 0.037 ng of As(v), 0.032 ng of DMA and 0.080 ng of MMA in club soda were achieved using the He-Ar plasma source. Similar limits of detection were found in urine and wine.  相似文献   

2.
A rapid and sensitive liquid chromatography–tandem mass spectrometric (LC‐MS/MS) assay method has been developed and fully validated for simultaneous quantification of donepezil and its active metabolite, 6‐o‐desmethyl donepezil in human plasma. Analytes and the internal standard were extracted from human plasma by liquid–liquid extraction technique using a 30:70 v/v mixture of ethyl acetate and n‐hexane. The reconstituted samples were chromatographed on a C18 column by using a 70:30 v/v mixture of acetonitrile and ammonium formate (5 mm , pH 5.0) as the mobile phase at a flow rate of 0.6 mL/min. The calibration curve obtained was linear (r ≥ 0.99) over the concentration range of 0.09–24.2 ng/mL for donepezil and 0.03–8.13 ng/mL for 6‐o‐desmethyl donepezil. The results of the intra‐day and inter‐day precision and accuracy studies were well within the acceptable limits. The proposed method was successfully applied for the estimation of the drug in real time plasma samples for pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
A highly sensitive and simple high-performance liquid chromatographic-tandem mass spectrometric (LC-MS-MS) assay is developed and validated for the quantification of sulforaphane and its metabolites in rat plasma. Sulforaphane (SFN) and its metabolites, sulforaphane glutathione (SFN-GSH) and sulforaphane N-acetyl cysteine (SFN-NAC) conjugates, are extracted from rat plasma by methanol-formic acid (100:0.1, v/v) and analyzed using a reversed-phase gradient elution on a Develosil 3 μm RP-Aqueous C(30) 140? column. A 15-min linear gradient with acetonitrile-water (5:95, v/v), containing 10 mM ammonium acetate and 0.2% formic acid, as mobile phase A, and acetonitrile-water (95:5, v/v), containing 10 mM ammonium acetate and 0.2% formic acid as mobile phase B, is used. Sulforaphane and its metabolites are well separated. Sulforaphene is used as the internal standard. The lower limits of quantification are 1 ng/mL for SFN and 10 ng/mL for both SFN-NAC and SFN-GSH. The calibration curves are linear over the concentration range of 25-20,000 ng/mL of plasma for each analyte. This novel LC-MS-MS method shows satisfactory accuracy and precision and is sufficiently sensitive for the performance of pharmacokinetic studies in rats.  相似文献   

4.
A new screening procedure for 18 narcotics in urine for anti-doping purposes has been developed using liquid chromatography/triple quadrupole mass spectrometry (LC/MS). Electrospray ionization (ESI) was used as interface. Infusion experiments were performed for all substances to investigate their mass spectrometric behaviour in terms of selecting product specific ions. These product ions were then used to develop a tandem mass spectrometric method using selected reaction monitoring (SRM). For the LC/MS analysis, chromatography was performed on an octadecylsilane column. The total run time of the chromatographic method was 5.5 min. For the sample preparation prior to LC/MS analysis, the urine samples were liquid-liquid extracted at pH 9.5 after overnight enzymatic hydrolysis. Two extraction solvents were evaluated: dichloromethane/methanol 9/1 (v/v), which is currently used for the extraction of narcotics, and diethyl ether, used for the extraction of steroids. With diethyl ether the detection limits for all compounds ranged between 0.5 and 20 ng/mL and with the mixture containing dichloromethane the detection limits ranged between 0.5 and 10 ng/mL. Taking into account the minimum required performance limits of the World Anti-Doping Agency of 200 ng/mL for narcotics, diethyl ether can also be considered as extraction solvent for narcotics. Finally, the described method was applied to the analysis of urine samples previously found to contain narcotics by our routine gas chromatography/mass spectrometry (GC/MS) method.  相似文献   

5.
A high-performance liquid chromatographic-tandem mass spectrometric (HPLC/MS/MS) method for the determination of 19-nortestosterone and its esters (cyclopentanepropionate, phenylpropionate, and decanoate) in equine plasma is achieved using an atmospheric pressure chemical ionization (APCI) interface in selected reaction monitoring (SRM) mode. The two internal standards used were 16,16, 17-(2)H(3)-19-nortestosterone for 19-nortestosterone and methenolone acetate for its esters. The steroids studied were extracted from plasma samples with a mixture of diethyl ether/n-hexane (9:1, v/v). The quantification limits for 19-nortestosterone, 19-nortestosterone cyclopentanepropionate, 19-nortestosterone phenylpropionate, and 19-nortestosterone decanoate were 0.16, 5.0, 0.1, and 2.0 ng/mL, respectively, when 2 mL of plasma were used. The recoveries of most of the steroids were 71.6-101.0% except for the decanoate, which could be recovered to about 39.8%. The responses were linear, with correlation coefficients varying from 0.9897 to 0.9999 in the concentration range of 0.1 to 50.0 ng/mL for the steroids studied. When applied to equine (mare) plasma samples, the present method allowed detection of 19-nortestosterone up to 23 days after an intra-muscular injection of 400 mg as the decanoate.  相似文献   

6.
This paper describes highly sensitive HPLC methods for the determination of amphetamine (AP) and methamphetamine (MP) in abusers' plasma and hair samples. AP and MP were derivatized with the fluorescent reagent, DIB-Cl, to yield a highly fluorescent DIB-derivatives of AP and MP, which were then analyzed by HPLC with fluorescence detection at excitation and emission wavelengths of 325 and 430 nm, respectively. The separation was achieved on an ODS column with isocratic mobile phases composed of acetoniltrile and citrate buffer (55:45, v/v) for plasma samples and of acetonitrile-methanol-citrate buffer (45:20:37.5, v/v/v) for hair samples. The limits of detection were less than 0.87 ng/mL and 0.12 ng/mg in plasma and hair samples, respectively, for both AP and MP. The methods were then applied to the determination of MP and its metabolite AP in plasma obtained from two cases of illegally ingested MP and in one of the cases' hair received later. Case I was treated with dialysis; samples before and after dialysis were analyzed by the described method. After dialysis for 5 h, the total plasma levels of AP and MP decreased from 720 to 190 ng/mL. For case II, MP and AP levels were monitored for 3 days after digestion. Total plasma levels decreased from 57 ng/mL in the day of digestion to 11 ng/mL after 3 days. In hair samples, AP and MP could also be detected in very low concentrations.  相似文献   

7.
建立了液相色谱–原子荧光光谱联用测定水产品中无机汞和甲基汞含量的方法。对影响测定结果的分析条件,如流动相组成、载流、还原剂、氧化剂、载气和屏蔽气进行了研究和优化,同时考察了该方法的有效性。结果表明:无机汞和甲基汞在质量浓度1~20 ng/m L范围内线性关系良好,相关系数分别为0.999 4,0.999 1;检出限分别为0.19,0.17 ng/m L;色谱峰面积的相对标准偏差分别为3.16%,2.16%(n=7);加标回收率分别为74%~100%,71%~91%。该方法可用于水产品中汞元素的形态分析。  相似文献   

8.
An improved liquid chromatographic tandem mass spectrometric method for the determination of glimepiride in human plasma has been developed and fully validated. The article describes in detail the bioanalytical procedure and summarizes the validation results obtained. The samples were extracted using liquid--liquid extraction with a mixture of 1-chlorobutane-isopropanol-ethyl acetate (88:2:10, v/v/v). The chromatographic separation was performed on a reversed-phase Hypersil ODScolumn (250 x 4.6 mm i.d.; 5 microm particle size) using a mobile phase consisting of formic acid 0.05 M-acetonitrile (28:72, v/v), pumped at a flow rate of 0.3 ml min(-1) heated to 25 degrees C. The analytes were detected using an API 3000 triple quadrupole mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. Tandem mass spectrometric detection enabled the quantitation of glimepiride down to 0.50 ng mL(-1). Calibration graphs were linear (r better than 0.998, n=1), in concentration range 0.50--1000 ng mL(-1), and the intra- and inter- day RSD values were less than 10.37 and 11.55% for glimepiride. The method was successfully applied to a kinetic study in order to assess the main pharmacokinetic parameters of glimepiride.  相似文献   

9.
A gas chromatography method with mass spectrometric detection is described for the determination of Salvinorin A, the main active ingredient of the hallucinogenic mint Salvia divinorum. The method was validated in plasma, urine, saliva and sweat using 17-alpha-methyltestosterone as internal standard. The analytes were extracted from biological matrices with chloroform/isopropanol (9:1, v/v). Chromatography was performed on a 5% phenyl methyl silicone capillary column and analytes were determined in the selected ion monitoring mode. The method was validated over the concentration range 0.015-5 microg/mL plasma, urine and saliva and 0.01-5 microg/patch in the case of sweat. Mean recoveries ranged between 77.1 and 92.7% for Salvinorin A in different biological matrices, with precision and accuracy always better than 15%. The method was applied to the analysis of urine, saliva and sweat from two consumers after smoking 75 mg plant leaves to verify the presence of the active ingredient of S. divinorum in human biological fluids as a biomarker of plant consumption. Salvinorin A was detected in urine (2.4 and 10.9 ng/mL) and saliva (11.1 and 25.0 ng/mL), but not in sweat patches from consumers.  相似文献   

10.
A rapid, simple, and highly sensitive second-derivative synchronous fluorometric method has been developed for the simultaneous analysis of binary mixtures of cinnarizine (CN) and nicergoline (NIC). The method is based upon measurement of the native fluorescence of these drugs at constant wavelength difference (Deltalambda) = 80 nm in aqueous methanol (50%, v/v). The different experimental parameters affecting the native fluorescence of the studied drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the range of 0.025-1.5 and 0.25-5.5 microg/mL for CN and NIC, respectively, with lower detection limits of 0.58 and 0.82 ng/mL and quantitation limits of 1.93 and 2.73 ng/mL for CN and NIC, respectively. The proposed method was successfully applied for the determination of the studied compounds in synthetic mixtures and in commercial tablets. The results obtained were in good agreement with those obtained with reference methods. The high sensitivity attained by the proposed method allowed the determination of CN in real and spiked human plasma. The mean recovery in the case of spiked human plasma [number of trials (n) = 3] was 102.82 +/- 2.17%, while that in real human plasma (n = 3) was 105.25 +/- 2.05.  相似文献   

11.
A highly sensitive liquid chromatographic-tandem mass spectrometric method (LC-MS-MS) is developed to quantitate ranolazine in human plasma. The analyte and internal standard tramadol are extracted from plasma by liquid-liquid extraction using diethyl ether-dichloromethane (60:40 v/v), and separated on a Zorbax extend C(18) column using methanol-10mM ammonium acetate (60:40 v/v, pH 4.0) at a flow of 1.0 mL/min. Detection is carried out by multiple reaction monitoring on a QtrapTM LC-MS-MS system with an electrospray ionization interface. The assay is linear over the range 10-5000 ng/mL with a limit of quantitation of 10 ng/mL and a lower limit of detection (S/N > 3) of 1 ng/mL. Intra- and inter-day precision are < 3.1% and < 2.8%, respectively, and the accuracy is in the range 96.7-101.6%. The validated method is successfully used to analyze the drug in samples of human plasma for pharmacokinetic studies.  相似文献   

12.
A sensitive, rapid and specific method for the simultaneous quantification of oxysophocarpine (OSC) and its active metabolite sophocarpine (SC) in rat plasma was developed and validated, using a liquid-liquid extraction procedure followed by liquid chromatography/electrospray ionization mass spectrometric (LC/ESI-MS) analysis. The separation was performed on a Zorbax Extend-C(18) column (2.1 mm i.d. x 50 mm, 5 microm) with a C(18) guard column using methanol-water containing 5 mm ammonium acetate (15:85, v/v) as mobile phase. Analysis was performed in selected ion monitoring (SIM) mode with an electrospray ionization (ESI) interface. [M + H](+) at m/z 263 for OSC, [M + H](+) at m/z 247 for SC and [M + H](+) at m/z 249 for matrine (internal standard) were selected as detecting ions, respectively. The method was linear in the concentration ranges 10-1000 ng/mL for OSC and 5-500 ng/mL for SC. The intra- and inter-day precisions (coefficient of variation) were within 7% for both analytes. Their accuracy (relative error) ranged from -6.4 to 1.5%. The limits of detection for OSC and SC were 3 and 1.5 ng/mL, respectively. The limits of quantitation for OSC and SC were 10 and 5 ng/mL, respectively. Recoveries of both analytes were greater than 85% at the low, medium and high concentrations. Both analytes were stable during all sample storage, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of OSC to rats with a dose of 15 mg/kg.  相似文献   

13.
The development of a liquid chromatography/tandem mass spectrometric assay for the quantitative analysis of the novel tubulin inhibitor D-24851 in human plasma and urine is described. D-24851 and the deuterated internal standard were extracted from 250 microL of plasma or urine using hexane/ether (1:1, v/v). Subsequently, 10-microL aliquots of reconstituted extracts were injected onto an Inertsil ODS analytical column (50 x 2.0 mm i.d., 5 microm particle size). An eluent consisting of methanol/5 mM ammonium acetate, 0.004% formic acid in water (80:20, v/v) was pumped at a flow rate of 0.2 mL/min. An API 365 triple quadrupole mass spectrometer was used in the multiple reaction monitoring mode for sensitive detection. For human plasma a dynamic range of 1-1000 ng/mL was validated, and for human urine a range of 0.25-50 ng/mL. Validation was performed according to the most recent FDA guidelines and all results were within requirements. The assay has been successfully applied to support a phase I clinical trial with orally administered D-24851.  相似文献   

14.
A UPLC/MS/MS method with simple protein precipitation has been validated for the fast simultaneous analysis of agomelatine, asenapine, amisulpride, iloperidone, zotepine, melperone, ziprasidone, vilazodone, aripiprazole and its metabolite dehydro‐aripiprazole in human serum. Alprenolol was applied as an internal standard. A BEH C18 (2.1 × 50 mm, 1.7 µm) column provided chromatographic separation of analytes using a binary mobile phase gradient (A, 2 mmol/L ammonium acetate, 0.1% formic acid in 5% acetonitrile, v/v/v; B, 2 mmol/L ammonium acetate, 0.1% formic acid in 95% acetonitrile, v/v/v). Mass spectrometric detection was performed in the positive electrospray ionization mode and ion suppression owing to matrix effects was evaluated. The validation criteria were determined: linearity, precision, accuracy, recovery, limit of detection, limit of quantification, reproducibility and matrix effect. The concentration range was as follows: 0.25–1000 ng/mL for agomelatine; 0.25–100 ng/mL for asenapine and iloperidone; 2.5–1000 ng/mL for amisulpride, aripiprazole, vilazodone and zotepine; 2.3–924.6 ng/mL for dehydroaripiprazole; 2.2–878.4 ng/mL for melperone; and 2.2–883.5 ng/mL for ziprasidone. Limits of quantitation below a therapeutic reference range were achieved for all analytes. Intra‐run precision of 0.4–5.5 %, inter‐run precision of 0.6–8.2% and overall recovery of 87.9–114.1% were obtained. The validated method was successfully implemented into routine practice for therapeutic drug monitoring in our hospital. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
Steroid determination by immunoassays results in significant interferences and inaccurate results. This study describes the development and validation of a new gas chromatographic-mass spectrometric method for the simultaneous quantification of 17alpha-hydroxyprogesterone (17alphaOHP), testosterone (T), dehydroepiandrosterone (DHEA), androstenedione (Delta4-A), cortisol (F) and pregnenolone (Preg) in serum of neonates. Steroids were extracted and purified from 0.5 mL serum using diethyl ether and Extrelut mini NT1 column. The extracts were derivatized with N-methyl-N-trimethylsilyl-trifluoroacetamide (MSTFA)/trimethylsilyl iodide (TMSI)/dithioerythritol (DTE) and the resulting trimethylsilyl derivatives were quantified by gas chromatography-selected ion monitoring-mass spectrometry (GC-SIM-MS). The detection limit for all steroids was lower than 0.1 ng/mL. The limit of quantification was 0.1 ng/mL for all steroids except cortisol which was at 0.25 ng/mL. d3-Testosterone and methyltestosterone served as internal standards. Precision for all compounds at the concentrations of 0.5, 1, 5 and 10 ng/mL (n = 10) in fortified steroid-free serum samples ranged from 0.8% to 16.6%. Accuracy was calculated at the concentrations of 0.5, 1, 5 and 10 ng/mL and ranged from -9.2% to 10.6% (n = 10). Linear calibration equations were obtained for all five steroids (0.125-31.25 ng/mL) and for cortisol (0.125-200 ng/mL). Relative recoveries at concentrations 1.0 and 12.5 ng/mL ranged from 70.5% to 97.5%. Absolute recoveries at the same concentrations ranged from 73.2% to 96.6%. Reference intervals were estimated for infants aged from 9 to 40 days. The proposed steroid profile is suitable for routine analysis and provides meaningful data for samples within normal range as well as those with elevated levels.  相似文献   

16.
A novel pre-column derivatization reversed-phase high-performance liquid chromatography with fluorescence detection is described for the determination of bupropion in pharmaceutical preparation, human plasma and human urine using mexiletine as internal standard. The proposed method is based on the reaction of 4-chloro-7-nitrobenzofurazan (NBD-Cl) with bupropion to produce a fluorescent derivative. The derivative formed is monitored on a C18 (150 mm × 4.6 mm i.d., 5 μm) column using a mobile phase consisting of methanol-water 75:25 (v/v), at a flow-rate of 1.2 mL/min and detected fluorimetrically at λ(ex) = 458 and λ(em) = 533 nm. The assay was linear over the concentration ranges of 5-500 and 10-500 ng/mL for plasma and urine, respectively. The limits of detection and quantification were calculated to be 0.24 and 0.72 ng/mL for plasma and urine, respectively (inter-day results). The recoveries obtained for plasma and urine were 97.12% ± 0.45 and 96.00% ± 0.45, respectively. The method presents good performance in terms of precision, accuracy, specificity, linearity, detection and quantification limits and robustness. The proposed method is applied to determine bupropion in commercially available tablets. The results were compared with an ultraviolet spectrophotometry method using t- and F-tests.  相似文献   

17.
An efficient and fast microwave-assisted extraction (MAE) method followed by gas chromatographic separation with mass spectrometric detection (GC–MS) was developed for the extraction of 18 organochlorine pesticides (OCPs) from sediment. Parameters affecting the MAE procedure such as the type and volume of the extraction solvent, irradiation power, temperature and irradiation time were successfully optimised. Under the optimal conditions, extraction efficiencies in the range of 73.4–119% were obtained with THF–HEX (9:1, v/v) for all OCPs studied. The method was linear over the range of 2.9–5000 ng g?1 with determination coefficients (r2) higher than 0.992 for all analytes. The limits of detection, LODs (S/N = 3), obtained varied from 1.0 to 2.2 ng g?1 and limits of quantification, LOQs (S/N = 10) were between 2.9 and 6.8 ng g?1. The proposed method was successfully applied to the analysis of real sediment samples and acceptable recoveries from 70.1 to 124% with RSDs ≤14.8% were obtained. 10 OCPs were determined below their LOQ and 8 OCPs in the range of 124–2830 ng g?1. The MAE method was compared with Soxhlet, shake flask and ultrasonic solvent extraction techniques. Thus, the MAE–GC–MS method could efficiently be used for selective extraction and quantification of the target analytes from the complex sediment matrices.  相似文献   

18.
利用超声波提取、固相萃取净化对样品进行前处理,然后采用气相色谱/质谱-选择离子检测模式对大米中的25种持久性有机污染物进行了分析。色谱条件:DB-35MS毛细管色谱柱(30 m×0.25 mm i.d.×0.25 μm);载气为氦气,流速1 mL/min;进样口温度300 ℃;不分流进样,进样量1 μL;柱温为程序升温模式。质谱条件:电子轰击电离源,70 eV;采集方式为选择离子方式,扫描质量范围50~450 u。实验采用保留时间以及定性、定量特征离子的丰度比定性,采用峰面积外标法定量,制作了25种持久性有机污染物的标准工作曲线。不同浓度水平的添加回收率试验表明,25种持久性有机污染物的添加回收率为81.99%~100.60%,相对标准偏差为2.37%~18.48%,除异狄氏剂、反式氯丹和顺式氯丹的检测限分别为20,30和20 ng/g外,其他有机污染物的检测限为0.1~5 ng/g。该方法的灵敏度、准确度和精密度均符合农药多残留测定技术的要求。  相似文献   

19.
A rapid and simple method for the simultaneous detection and quantitation of amphetamine, methamphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA) and methylenedioxyethylamphetamine (MDEA) in human serum was developed and fully validated. Serum samples were extracted with cyclohexane, derivatised with perfluorooctanoyl chloride without prior evaporation of the solvent and analysed with gas chromatography-mass spectrometry (GC-MS) in the selected ion monitoring mode (SIM). For quantitation, deuterated analogues were used as the internal standards. The limit of detection (LOD) and lower limit of quantitation (LLOQ), bias and within-day and between-day precision were determined. LODs calculated as the average of the six calibration curves were below 5 ng/mL for all of the measured compounds; LLOQs obtained in the same manner were below 20 ng/mL, with the exception of MDA (24.1 ng/mL). The coefficients of variation were below 7% within series, 10% or less between series and the bias was below 8% for all compounds. The calibration curves were linear between the lower limits of quantitation and 800 ng/mL. Presented in part at 12. Jahrestagung, Deutsche Gesellschaft für Rechtsmedizin, May 2003, Kiel, Germany.  相似文献   

20.
A simple and sensitive method was developed for the simultaneous quantification of harpagoside and cinnamic acid in rat plasma using high-performance liquid chromatography system coupled to a negative ion electrospray mass spectrometric analysis. The plasma sample preparation was a simple deproteinization by the addition of two volumes of acetonitrile. The analytes were separated on an Intersil C8-3 column (2.1 mm i.d.x250 mm, 5 microm) with acetonitrile-5 mm ammonium formate aqueous solution (60:40, v/v) as mobile phase at a flow-rate of 0.2 mL/min. Detection was performed on a quadrupole mass spectrometer equipped with electrospray ionization (ESI) source operated under selected ion monitoring (SIM) mode. [M+HCOO]- at m/z 539 for harpagoside, [M-H]- at m/z 147 for cinnamic acid and [M-H]- at m/z 137 for salylic acid (internal standard) were selected as detecting ions, respectively. The method was validated over the concentration range 7-250 ng/mL for harpagoside and 5-500 ng/mL for cinnamic acid. The lower limits of quantitation for harpagoside and cinnamic acid were 7 and 5 ng/mL, respectively. The intra- and inter-day precisions (RSD%) were within 9.5% and the assay accuracies (RE%) ranged from -5.3 to 3.0% for both analytes. Their average recoveries were greater than 86%. Both analytes were proved to be stable during all sample storage, preparation and analysis procedures. The method was successfully applied to the pharmacokinetic study of harpagoside and cinnamic acid following oral administration of Radix Scrophulariae extract to rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号